22 resultados para signal noise


Relevância:

20.00% 20.00%

Publicador:

Resumo:

By detecting leading protons produced in the Central Exclusive Diffractive process, p+p → p+X+p, one can measure the missing mass, and scan for possible new particle states such as the Higgs boson. This process augments - in a model independent way - the standard methods for new particle searches at the Large Hadron Collider (LHC) and will allow detailed analyses of the produced central system, such as the spin-parity properties of the Higgs boson. The exclusive central diffractive process makes possible precision studies of gluons at the LHC and complements the physics scenarios foreseen at the next e+e− linear collider. This thesis first presents the conclusions of the first systematic analysis of the expected precision measurement of the leading proton momentum and the accuracy of the reconstructed missing mass. In this initial analysis, the scattered protons are tracked along the LHC beam line and the uncertainties expected in beam transport and detection of the scattered leading protons are accounted for. The main focus of the thesis is in developing the necessary radiation hard precision detector technology for coping with the extremely demanding experimental environment of the LHC. This will be achieved by using a 3D silicon detector design, which in addition to the radiation hardness of up to 5×10^15 neutrons/cm2, offers properties such as a high signal-to- noise ratio, fast signal response to radiation and sensitivity close to the very edge of the detector. This work reports on the development of a novel semi-3D detector design that simplifies the 3D fabrication process, but conserves the necessary properties of the 3D detector design required in the LHC and in other imaging applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differentiation of various types of soft tissues is of high importance in medical imaging, because changes in soft tissue structure are often associated with pathologies, such as cancer. However, the densities of different soft tissues may be very similar, making it difficult to distinguish them in absorption images. This is especially true when the consideration of patient dose limits the available signal-to-noise ratio. Refraction is more sensitive than absorption to changes in the density, and small angle x-ray scattering on the other hand contains information about the macromolecular structure of the tissues. Both of these can be used as potential sources of contrast when soft tissues are imaged, but little is known about the visibility of the signals in realistic imaging situations. In this work the visibility of small-angle scattering and refraction in the context of medical imaging has been studied using computational methods. The work focuses on the study of analyzer based imaging, where the information about the sample is recorded in the rocking curve of the analyzer crystal. Computational phantoms based on simple geometrical shapes with differing material properties are used. The objects have realistic dimensions and attenuation properties that could be encountered in real imaging situations. The scattering properties mimic various features of measured small-angle scattering curves. Ray-tracing methods are used to calculate the refraction and attenuation of the beam, and a scattering halo is accumulated, including the effect of multiple scattering. The changes in the shape of the rocking curve are analyzed with different methods, including diffraction enhanced imaging (DEI), extended DEI (E-DEI) and multiple image radiography (MIR). A wide angle DEI, called W-DEI, is introduced and its performance is compared with that of the established methods. The results indicate that the differences in scattered intensities from healthy and malignant breast tissues are distinguishable to some extent with reasonable dose. Especially the fraction of total scattering has large enough differences that it can serve as a useful source of contrast. The peaks related to the macromolecular structure come to angles that are rather large, and have intensities that are only a small fraction of the total scattered intensity. It is found that such peaks seem to have only limited usefulness in medical imaging. It is also found that W-DEI performs rather well when most of the intensity remains in the direct beam, indicating that dark field imaging methods may produce the best results when scattering is weak. Altogether, it is found that the analysis of scattered intensity is a viable option even in medical imaging where the patient dose is the limiting factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular machinery on the micro-scale, believed to be the fundamental building blocks of life, involve forces of 1-100 pN and movements of nanometers to micrometers. Micromechanical single-molecule experiments seek to understand the physics of nucleic acids, molecular motors, and other biological systems through direct measurement of forces and displacements. Optical tweezers are a popular choice among several complementary techniques for sensitive force-spectroscopy in the field of single molecule biology. The main objective of this thesis was to design and construct an optical tweezers instrument capable of investigating the physics of molecular motors and mechanisms of protein/nucleic-acid interactions on the single-molecule level. A double-trap optical tweezers instrument incorporating acousto-optic trap-steering, two independent detection channels, and a real-time digital controller was built. A numerical simulation and a theoretical study was performed to assess the signal-to-noise ratio in a constant-force molecular motor stepping experiment. Real-time feedback control of optical tweezers was explored in three studies. Position-clamping was implemented and compared to theoretical models using both proportional and predictive control. A force-clamp was implemented and tested with a DNA-tether in presence of the enzyme lambda exonuclease. The results of the study indicate that the presented models describing signal-to-noise ratio in constant-force experiments and feedback control experiments in optical tweezers agree well with experimental data. The effective trap stiffness can be increased by an order of magnitude using the presented position-clamping method. The force-clamp can be used for constant-force experiments, and the results from a proof-of-principle experiment, in which the enzyme lambda exonuclease converts double-stranded DNA to single-stranded DNA, agree with previous research. The main objective of the thesis was thus achieved. The developed instrument and presented results on feedback control serve as a stepping stone for future contributions to the growing field of single molecule biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tinnitus is a frequent consequence of noise trauma. Usually, however, the main focus regarding the consequences of noise trauma is placed on hearing loss, instead of tinnitus. The objectives of the present study were to assess various aspects of noise-related tinnitus in Finland, such as to determine the main causes of conscript acute acoustic traumas (AAT) in the military, assess tinnitus prevalence after noise trauma, characterize long-term AAT-related tinnitus prevalence and characteristics, assess occupational tinnitus, and evaluate the efficacy of hearing protection regulations in preventing hearing loss and tinnitus. The study comprised several independent noise-exposed groups: conscripts performing their military duty, former conscripts who suffered an AAT over a decade earlier, bomb explosion victims, and retired army personnel. Tinnitus questionnaires were used to assess tinnitus prevalence and characteristics. For occupational tinnitus, occupational noise-induced hearing loss (NIHL) reports to the Finnish Institute of Occupational Health were reviewed. Tinnitus is a common result of AAT, blast exposure and long-term noise exposure. Despite hearing protection regulations, up to hundreds of AATs occur annually among conscripts in the Finnish Defence Forces (FDF). The most common cause is an accidental shot, accounting for approximately half of the cases. Conscript AATs are mainly due to accidental shots, while the ear is unprotected. Only seldom is an AAT due to negligence. The most common causative weapon of conscript AATs is the assault rifle, accounting for 81% of conscript AATs. After AAT, the majority of tinnitus cases resolve during military service and become asymptomatic. However, in one-fifth of the cases, tinnitus persists, causing problems such as sleeping and concentration difficulties in many. In Finland, occupational tinnitus often remains unreported in conjunction with NIHL reports. In a survey of occupational NIHL cases, tinnitus was mentioned in only four per cent. However, a subsequent inquiry revealed that almost 90% in fact had tinnitus, indicating that most cases remained undetected and unreported. The best way to prevent noise-related tinnitus is prevention of noise trauma. In the military, hearing protection guidelines have been revised several times over the years. These regulations have been effective in reducing hearing loss of professional soldiers. There has also been a reduction in cases with tinnitus, but the decrease was not significant. However, with improved hearing protection regulations, a significant reduction in the risk of more serious, disturbing tinnitus was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tasaikäisen metsän alle muodostuvilla alikasvoksilla on merkitystä puunkorjuun, metsänuudistamisen, näkemä-ja maisema-analyysien sekä biodiversiteetin ja hiilitaseen arvioinnin kannalta. Ilma-aluksista tehtävä laserkeilaus on osoittautunut tehokkaaksi kaukokartoitusmenetelmäksi varttuneiden puustojen mittauksessa. Laserkeilauksen käyttöönotto operatiivisessa metsäsuunnittelussa mahdollistaa aiempaa tarkemman tiedon tuottamisen alikasvoksista, mikäli alikasvoksen ominaisuuksia voidaan tulkita laseraineistoista. Tässä työssä käytettiin tarkasti mitattuja maastokoealoja ja kaikulaserkeilausaineistoja (discrete return LiDAR) usealta vuodelta (1–2 km lentokorkeus, 0,9–9,7 pulssia m-2). Laserkeilausaineistot oli hankittu Optech ALTM3100 ja Leica ALS50-II sensoreilla. Koealat edustavat suomalaisia tasaikäisiä männiköitä eri kehitysvaiheissa. Tutkimuskysymykset olivat: 1) Minkälainen on alikasvoksesta saatu lasersignaali yksittäisen pulssin tasolla ja mitkä tekijät signaaliin vaikuttavat? 2) Mikä on käytännön sovelluksissa hyödynnettävien aluepohjaisten laserpiirteiden selitysvoima alikasvospuuston ominaisuuksien ennustamisessa? Erityisesti haluttiin selvittää, miten laserpulssin energiahäviöt ylempiin latvuskerroksiin vaikuttavat saatuun signaaliin, ja voidaanko laserkaikujen intensiteetille tehdä energiahäviöiden korjaus. Puulajien väliset erot laserkaiun intensiteetissä olivat pieniä ja vaihtelivat keilauksesta toiseen. Intensiteetin käyttömahdollisuudet alikasvoksen puulajin tulkinnassa ovat siten hyvin rajoittuneet. Energiahäviöt ylempiin latvuskerroksiin aiheuttivat alikasvoksesta saatuun lasersignaaliin kohinaa. Energiahäviöiden korjaus tehtiin alikasvoksesta saaduille laserpulssin 2. ja 3. kaiuille. Korjauksen avulla pystyttiin pienentämään kohteen sisäistä intensiteetin hajontaa ja parantamaan kohteiden luokittelutarkkuutta alikasvoskerroksessa. Käytettäessä 2. kaikuja oikeinluokitusprosentti luokituksessa maan ja yleisimmän puulajin välillä oli ennen korjausta 49,2–54,9 % ja korjauksen jälkeen 57,3–62,0 %. Vastaavat kappa-arvot olivat 0,03–0,13 ja 0,10–0,22. Tärkein energiahäviöitä selittävä tekijä oli pulssista saatujen aikaisempien kaikujen intensiteetti, mutta hieman merkitystä oli myös pulssin leikkausgeometrialla ylemmän latvuskerroksen puiden kanssa. Myös 3. kaiuilla luokitustarkkuus parani. Puulajien välillä havaittiin eroja siinä, kuinka herkästi ne tuottavat kaiun laserpulssin osuessa puuhun. Kuusi tuotti kaiun suuremmalla todennäköisyydellä kuin lehtipuut. Erityisen selvä tämä ero oli pulsseilla, joissa oli energiahäviöitä. Laserkaikujen korkeusjakaumapiirteet voivat siten olla riippuvaisia puulajista. Sensorien välillä havaittiin selviä eroja intensiteettijakaumissa, mikä vaikeuttaa eri sensoreilla hankittujen aineistojen yhdistämistä. Myös kaiun todennäköisyydet erosivat jonkin verran sensorien välillä, mikä aiheutti pieniä eroavaisuuksia kaikujen korkeusjakaumiin. Aluepohjaisista laserpiirteistä löydettiin alikasvoksen runkolukua ja keskipituutta hyvin selittäviä piirteitä, kun rajoitettiin tarkastelu yli 1 m pituisiin puihin. Piirteiden selitysvoima oli parempi runkoluvulle kuin keskipituudelle. Selitysvoima ei merkittävästi alentunut pulssitiheyden pienentyessä, mikä on hyvä asia käytännön sovelluksia ajatellen. Lehtipuun osuutta ei pystytty selittämään. Tulosten perusteella kaikulaserkeilausta voi olla mahdollista hyödyntää esimerkiksi ennakkoraivaustarpeen arvioinnissa. Sen sijaan alikasvoksen tarkempi luokittelu (esim. puulajitulkinta) voi olla vaikeaa. Kaikkein pienimpiä alikasvospuita ei pystytä havaitsemaan. Lisää tutkimuksia tarvitaan tulosten yleistämiseksi erilaisiin metsiköihin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microbes in natural and artificial environments as well as in the human body are a key part of the functional properties of these complex systems. The presence or absence of certain microbial taxa is a correlate of functional status like risk of disease or course of metabolic processes of a microbial community. As microbes are highly diverse and mostly notcultivable, molecular markers like gene sequences are a potential basis for detection and identification of key types. The goal of this thesis was to study molecular methods for identification of microbial DNA in order to develop a tool for analysis of environmental and clinical DNA samples. Particular emphasis was placed on specificity of detection which is a major challenge when analyzing complex microbial communities. The approach taken in this study was the application and optimization of enzymatic ligation of DNA probes coupled with microarray read-out for high-throughput microbial profiling. The results show that fungal phylotypes and human papillomavirus genotypes could be accurately identified from pools of PCR amplicons generated from purified sample DNA. Approximately 1 ng/μl of sample DNA was needed for representative PCR amplification as measured by comparisons between clone sequencing and microarray. A minimum of 0,25 amol/μl of PCR amplicons was detectable from amongst 5 ng/μl of background DNA, suggesting that the detection limit of the test comprising of ligation reaction followed by microarray read-out was approximately 0,04%. Detection from sample DNA directly was shown to be feasible with probes forming a circular molecule upon ligation followed by PCR amplification of the probe. In this approach, the minimum detectable relative amount of target genome was found to be 1% of all genomes in the sample as estimated from 454 deep sequencing results. Signal-to-noise of contact printed microarrays could be improved by using an internal microarray hybridization control oligonucleotide probe together with a computational algorithm. The algorithm was based on identification of a bias in the microarray data and correction of the bias as shown by simulated and real data. The results further suggest semiquantitative detection to be possible by ligation detection, allowing estimation of target abundance in a sample. However, in practise, comprehensive sequence information of full length rRNA genes is needed to support probe design with complex samples. This study shows that DNA microarray has the potential for an accurate microbial diagnostic platform to take advantage of increasing sequence data and to replace traditional, less efficient methods that still dominate routine testing in laboratories. The data suggests that ligation reaction based microarray assay can be optimized to a degree that allows good signal-tonoise and semiquantitative detection.