Detection and Characterization of Long-Pulse Low-Velocity Impact Damage in Plastic Bonded Explosives
Resumo:
Damage not only degrades the mechanical properties of explosives, but also influences the shock sensitivity, combustion and even detonation behavior of explosives. The study of impact damage is crucial in the vulnerability evaluation of explosives. A long-pulse low-velocity gas gun with a gas buffer was developed and used to induce impact damage in a hot pressed plastic bonded explosive. Various methods were used to detect and characterize the impact damage of the explosive. The microstructure was examined by use of polarized light microscopy. Fractal analysis of the micrographs was conducted by use of box counting method. The correlation between the fractal dimensions and microstructures was analyzed. Ultrasonic testing was conducted using a pulse through-transmission method to obtain the ultrasonic velocity and ultrasonic attenuation. Spectra analyses were carried out for recorded ultrasonic signals using fast Fourier transform. The correlations between the impact damage and ultrasonic parameters including ultrasonic velocities and attenuation coefficients were also analyzed. To quantitatively assess the impact induced explosive crystal fractures, particle size distribution analyses of explosive crystals were conducted by using a thorough etching technique, in which the explosives samples were soaked in a solution for enough time that the binder was totally removed. Impact induces a large extent of explosive crystal fractures and a large number of microcracks. The ultrasonic velocity decreases and attenuation coefficients increase with the presence of impact damage. Both ultrasonic parameters and fractal dimension can be used to quantitatively assess the impact damage of plastic bonded explosives.
Resumo:
UTT (Ultrasonic Tomography Tool) is widely used in the oil industry and can be used to inspect corrosion, casing wall damage, casing breakoff, and casing distortion in the well borehole with the maximum environment temperature being 125 °C, and the pressure being 60 MPa. UTT consists of tool head, upper centralization, electronic section, lower centralization, transmitters, and receivers. Its outer diameter is 4.6 cm and length is 320 cm. The measured casing diameter ranges from 60 mm to 254 mm. The tomography resolution is 512×512. The borehole measurement accuracy is 2 mm. It can supply 3D pipe tomography, including horizontal and vertical profile. This paper introduces its specification, measurement principle, and applications in oilfield.damage, casing breakoff, and casing distortion in the well borehole with the maximum environment temperature being 125 °C, and the pressure being 60 MPa. UTT consists of tool head, upper centralization, electronic section, lower centralization, transmitters, and receivers. Its outer diameter is 4.6 cm and length is 320 cm. The measured casing diameter ranges from 60 mm to 254 mm. The tomography resolution is 512×512. The borehole measurement accuracy is 2 mm. It can supply 3D pipe tomography, including horizontal and vertical profile. This paper introduces its specification, measurement principle, and applications in oilfield.
Resumo:
This paper explores an on-line experimental method to highlight the process of internal damage development in composites by taking advantage of ultrasonic inspection. A loading device, which can work together with an ultrasonic inspection system, was designed, and the interlaminar shear damage of a double-sided grooved specimen of composite was examined on-line with the system. A full view of the progressive internal interlaminar damage, seen only with difficulty by common inspection methods, was successfully achieved.
Resumo:
An ultrasonic pulse-echo method was used to measure the transit time of longitudinal and transverse (10 MHz) elastic waves in a Nd60Al10Fe20Co10 bulk metallic glass (BMG). The measurements were carried out under hydrostatic pressure up to 0.5 GPa at room temperature. On the basis of experimental data for the sound velocities and density, the elastic moduli and Debye temperature of the BMG were derived as a function of pressure. Murnaghan's equation of state is obtained. The normal behaviour of the positive pressure dependence of the ultrasonic velocities was observed for this glass. Moreover, the compression curve, the elastic constants, and the Debye temperature of the BMG are calculated on the basis of the similarity between their physical properties in the glassy state and those in corresponding crystalline state. These results confirm qualitatively the theoretical predictions concerning the features of the microstructure and interatomic bonding in the Nd60Al10Fe20Co10 BMG.
Resumo:
Experimental research on a 150 kW arc-heated plasma testing facility was conducted. Stable plasma jets with different gas compositions, temperatures and velocities were obtained at chamber pressure between 400 Pa – 100 kPa. Stagnation ablation experiments were conducted on samples of typical super alloys used for thermal protection systems. The microstructure and hardness of alloys before and after ablation were compared.
Resumo:
A new type of wave-front analysis method for the collimation testing of laser beams is proposed. A concept of wave-front height is defined, and, on this basis, the wave-front analysis method of circular aperture sampling is introduced. The wave-front height of the tested noncollimated wave can be estimated from the distance between two identical fiducial diffraction planes of the sampled wave, and then the divergence is determined. The design is detailed, and the experiment is demonstrated. The principle and experiment results of the method are presented. Owing to the simplicity of the method and its low cost, it is a promising method for checking the collimation of a laser beam with a large divergence. © 2005 Optical Society of America.
Resumo:
We proposed a new method of measuring the degree of collimation of laser beam using axial intensity information near paraxial focus. Preceding methods for collimation testing are mainly either based on self-imaging or interferometric techniques. The new method is to employ the diffraction behavior of noncollimated wave in circular aperture diaphragm. The principle of the proposed method and experiment results are presented. Due to simplicity of the method and its low cost, it is a promising method for checking the collimation of laser beam. (c) 2005 Published by Elsevier GmbH.
Resumo:
Horseflies are economically important blood-feeding arthropods and also a nuisance for humans and vectors for filariasis. They rely heavily on the pharmacological properties of their saliva to get a blood meal and suppress immune reactions of hosts. Little information is available on antihemostatic substances in horsefly salivary glands; especially no horsefly immune suppressants have been reported. By proteomics or peptidomics and coupling transcriptome analysis with pharmacological testing, several families of proteins or peptides, which act mainly on the hemostatic system or immune system of the host, were identified and characterized from 30,000 pairs salivary glands of the horsefly Tabanus yao (Diptera, Tabanidae). They are: (i) a novel family of inhibitors of platelet aggregation including two members, which possibly inhibit platelet aggregation by a novel mechanism and act on platelet membrane, (ii) a novel family of immunosuppressant peptides including 12 members, which can inhibit interferon-gamma production and increase interleukin-10 secretion, (iii) a serine protease inhibitor with 56 amino acid residues containing anticoagulant activity, (iv) a serine protease with anticoagulant activity, (v) a protease with fibrinogenolytic activity, (vi) three families of antimicrobial peptides including six members, (vii) a hyaluronidase, (viii) a vasodilator peptide, which is an isoform of vasotab identified from Hybomitra bimaculata, and interestingly (ix) two metallothioneins, which are the first metallothioneins reported from invertebrate salivary glands. The current work will facilitate the understanding of the molecular mechanisms of the ectoparasite-host relationship and help in identifying novel vaccine targets and novel leading pharmacological compounds.
Resumo:
The commercialization of 'big science' is in full swing, leading to situations in which the ethical principles of academia are beginning to be compromised. This is exemplified by the profitable business of genetic ancestry testing. The goals of this sort
Resumo:
Ultrasonic solvent extraction combined with solid-phase microextraction (SPME) with calix[4]arene/hydroxy-terminated silicone (C[4]/OHTSO) oil coated fiber was used to extract phthalate acid esters (PAEs) plasticizers in plastic, such as blood bags, transfusion tubing, food packaging bag, and mineral water bottle for analysis by gas chromatography (GC). Both extraction parameters (i.e. extraction time, extraction temperature, ionic strength) and conditions of the thermal desorption in a GC injector were optimized by analysis of eight phthalates. The fiber shows wonderful sensitivity and selectivity to the tested compounds. Owing to its high thermal stability (380 degreesC), the carryover effect that often encountered when using conventional fibers can be reduced by appropriately enhancing the injector temperature. The method showed linear response over two to four orders of magnitude with correlation coefficients (r) better than 0.996, and limits of detection (LOD) ranged between 0.006 and 0.084 mug l(-1). The relative standard deviation values obtained were less than or equal to 10%. bis-2-Ethylhexyl phthalate (DEHP) was the sole analyte detected in these plastics and recoveries were in the ranges 95.5-101.4% in all the samples. (C) 2004 Elsevier B.V. All rights reserved.