17 resultados para Rumble strips.

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

提出了一种能够测量高温的光纤布拉格光栅(FBG)传感器结构。利用线膨胀系数和长度均不同的两种金属细杆和光纤布拉格光栅设计而成的传感头,能够将被测温度转化为光栅的应变,解调由应变引起的光栅波长漂移,即可得知待测的温度。目前在实验室实现了500℃的动态范围和1℃的温度分辨率,实验结果与理论分析一致。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Phase locking of two fiber lasers is demonstrated experimentally by the use of a self-imaging resonator with a spatial filter. The high-contrast interference strips of the coherent beam profile are observed. The coherent output power of the fiber array exceeds 12W and the efficiency of coherent power combination is 88% with pump power of 60W. The whole system operates quite stably and, for the spatial filter, no thermal effects have been observed, which means that we can increase the coherent output power further by this method. (c) 2006 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Up-converting phosphor technology (UPT)-based lateral-flow immunoassay has been developed for quantitative detection of Yersinia pestis rapidly and specifically. In this assay, 400 nm up-converting phosphor particles were used as the reporter. A sandwich immumoassay was employed by using a polyclonal antibody against F1 antigen of Y. pestis immobilized on the nitrocellulose membrane and the same antibody conjugated to the UPT particles. The signal detection of the strips was performed by the UPT-based biosensor that could provide a 980 nm IR laser to excite the phosphor particles, then collect the visible luminescence emitted by the UPT particles and finally convert it to the voltage as a signal. V-T and V-c stand for the multiplied voltage units for the test and the control line, respectively, and the ratio V-T/V-C is directly proportional to the number of Y pestis in a sample. We observed a good linearity between the ratio and log CFU/ml of Y pestis above the detection limit, which was approximately 10(4) CFU/mI. The precision of the intra- and inter-assay was below 15% (coefficient of variation, CV). Cross-reactivity with related Gram-negative enteric bacteria was not found. The UPT-LF immunoassay system presented here takes less than 30 min to perform from the sample treatment to the data analysis. The current paper includes only preliminary data concerning the biomedical aspects of the assay, but is more concentrated on the technical details of establishing a rapid manual assay using a state-of-the-art label chemistry. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Amphibian skin is a rich resource of bioactive peptides like proline-rich bombesin from frog Bombina maxima. A novel cDNA clone encoding a precursor protein that comprises proline-rich bombesin and a novel peptide, designated as bombestatin, was isolated from a skin cDNA library of B. maxima. The predicted primary structure of the novel peptide is WEVLLNVALIRLELLSCRSSKDQDQKESCGMHSW, in which two cysteines form a disulfide bond. A BLAST search of databases did not detect sequences with significant similarity. Bombestatin possesses dose-dependent contractile activity on rat stomach strips. The differences between cDNAs encoding PR-bombesin plus bombestatin and PR-bombesin alone are due to fragment insertions located in 3'-coding region and 3'-untranslational region, respectively. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SiO2-TiO2 sol-gel films are deposited on SiO2/Si by dip-coating technique. The SiO2-TiO2 strips are fabricated by laser direct writing using all ytterbium fiber laser and followed by chemical etching. Surface structures, morphologies and roughness of the films and strips are characterized. The experimental results demonstrate that the SiO2-TiO2 sol-gel film is loose in Structure and a shrinkage concave groove forms if the film is irradiated by laser beam. The surface roughness of both non-irradiated and laser irradiated areas increases with the chemical etching time. But the roughness of laser irradiated area increases more than that of non-irradiated area under the same etching time. After being etched for 28 s, the surface roughness value of the laser irradiated area increases from 0.3 nm to 3.1 nm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The novel Si stripixel detector, developed at BNL (Brookhaven National Laboratory), has been applied in the development of a prototype Si strip detector system for the PHENIX Upgrade at RHIC. The Si stripixel detector can generate X-Y two-dimensional (2D) position sensitivity with single-sided processing and readout. Test stripixel detectors with pitches of 85 and 560 mu m have been subjected to the electron beam test in a SEM set-up, and to the laser beam test in a lab test fixture with an X-Y-Z table for laser scanning. Test results have shown that the X and Y strips are well isolated from each other, and 2D position sensitivity has been well demonstrated in the novel stripixel detectors. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surface roughness and its correlation with the polarity of internal hexagonal inclusions and cubic twins have been investigated by atomic force microscopy (AFM), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and X-ray diffraction (XRD). The surface roughness resulted from large amount of strips, which prolonged in [1 (1) over bar0] direction with small size in [110] or [110] direction. The sidestep of each strip is just the top of high density of hexagonal inclusions or cubic microtwins. Moreover, XRD shows that the amount of hexagonal inclusions and cubic microtwins measured in [110] direction are twice or more as much as in [110] direction. Therefore, it is hexagonal inclusions, cubic twins and their distributive polarity that is responsible to the surface characteristics of cubic GaN epilayers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a study on the facet damage profile of quantum cascade lasers (QCLs). Conspicuous cascade half-loop damage strips on front facet are observed when QCLs catastrophically failed. Due to the large difference on thermal conductivities between active region and the substrate, dominant heat is compulsively driven to the substrate. Abundant heat accumulation and dissipation on substrate build large temperature gradient and thermal lattice mismatch. Thermal-induced stress due to sequential mismatch leads to the occurrence of the multistep damages on front facet. Good agreement is achieved between the observed locations of damaged strips and the calculated results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the last years FOPI has developed a new ToF system as an upgrade of the existing detector based on Multi-strip Multi-gap Resistive Plate Chambers (MMRPCs). The intention is to increase the charged Kaon identification up to a laboratory momentum of 1 GeV/c and to enhance the azimuthal detector granularity. The new ToF barrel has an active area of 5 m(2) with 2400 individual strips (900 x 1.6 mm(2)) [A. Schuttauf, et al., Nucl. Phys. B 158 (2006) 52] which are read out on both sides by a custom designed electronics [M. Ciobanu, et al., IEEE Trans. Nucl. Sci. NS-54 (4) (2007) 1201; K. Koch, et al., IEEE Trans. Nucl. Sci. NS-52(3) (2005) 745]. To reach the envisaged goal a time resolution of 100 ps is needed, at a flight path of 1-1.3 m. Due to the rare production of the K- at SIS energies the efficiency of the MMRPCs has to be above 95%. We report on measurements with the detectors and electronics from the mass production line. For this purpose we used a proton beam at 2.0 and 1.25 GeV, at rates between 0.1 and 5 kHz/cm(2) to determine the timing, efficiency and rate capability of the MMRPCs

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the experiment of nuclear reaction, it is important to measure the mass, charge, energy and emitted direction of particles. For multiparameter measurement, we must use a detector or a group of detectors which can give the time, energy, and position information. The Large Area position sensitive Ionization Chamber(LAIC) is one of the eight experiment terminals of HIRFL. It is built for researching nuclear reactions from low energy to intermediate energy. It is an excellent equipment for energy measurements and atomic number identification of emitted fragments in this energy region. It is also designed to give the time and position information of the emitted fragments by itself. Obviously, an IC can not supply a good timing signal. Moreover, the mechanical installation is different from the original design by some other reasons. In this case, it is not enough to obtain the correct direction information of the emitted fragments. To obtain good timing signals and the correct direction information, some modifications must be made. It is well known that a PPAC can give us excellent timing signals. It also can be easily built as a position sensitive detector. For this reason, a specially designed PPAC is installed in the entrance of the LAIC. For the different purposes, two types of PPACs were designed and tested. Both are OCTPSACs (OCTunit one dimension Position Sensitive Avalanche Counter). In this paper, both OCTPSACs will be introduced. Based on the requirements of the LAIC, the OCTPSACs consist of eight position sensitive PPACs. Each PPAC has an anode and a cathode. In both cases, the sizes are same. But different type of cathodes are used. In one type of OCTPSAC, its cathode is made of wire plane. It consists of gold-plated tungsten wires with the diameter of 20μm, spaced 0.5 mm apart from each other. The anode is a mylar foil which was evaporated by gold layer with the thickness of 50μg/cm~2 mounted on a printed plate in the shape of rectangle. the thickness of mylar foil is 1.5μm. The gap between anode and cathode is 3mm. The performance of the OCTPSAC has been tested by using a ~(252)Cf source in flowing isobutylene gas at the pressure of 3.4mb. The intrinsic time resolution of 289ps and position resolution of 2 mm have been obtained. In another type of OCTPSAC, the cathode is made of mylar foil, which is composed of gold strip by vacuume evaporation method with a special mask on the mylar foil. The thickness and the width of the gold strip is 50μg/cm~2 and 1.7mm. The strips are spaced 0.3 mm apart from each other. The anode is the same as the former type. We have obtained the time resolution of 296ps and position resolution of 2mm by using ~(241)Am-a source when the gas pressure is 6 mb and high voltage is 600V. The working gas is heptane

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection amperometric immunoassay system based on the use of screen-printed carbon electrode for the detection of mouse IgG was developed. An immunoelectrode strip, on which an immunosorbent layer and screen-printed carbon electrode were integrated, and a proposed flow cell have been fabricated. The characterization of the flow immunoassay system and parameters affecting the performance of the immunoassay system were studied and optimized. Amperometric detection at 0.0 V (versus Ag/AgCl) resulted in a linear detection range of 30-700 ng ml(-1), with a detection limit of 3 ng ml(-1). The signal variation among electrode strips prepared from variant batch did not exceed 8.5% (n = 7) by measuring 0.5 mug ml(-1) antigen standard solution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The morphology of the beach backshore and foreshore at Huiquan Bay, Qingdao, China, is characterized by a single intertidal sandbar system with a spring tide range of 4.59 m. The beach was measured with a laser total station of Leica TPS402. Contours of the beach were generated using data collected in March and November 2005. The survey method provided 2 mm measuring accuracy and 4-10 m horizontal spacing. The net accretion volume of the foreshore was about 11, 215 m(3) from March to November. After sand sculpture activity, the axis of the sand trough migrated onshore from about 3.5 m to 17.5 m on the foreshore beach in November. At the same time, the axis of the sandbar crest migrated onshore no more than 42.25 m on the northwest foreshore; and it migrated offshore no more than 23.75 m on the southeast foreshore. On the northwest and southeast foreshore beach, two strips of erosion areas with a thickness of 0-0.2 m appeared on the sandbar crest. Accretion occurred at the bottom of the sand trough with a thickness of similar to 0.2-0.6 m. The sandbar height decreased after sand sculpture activity, and it was no more than 0.7 m in March and 0.6 m in November. Human activities, such as sand digging on the sandbar crest during sand sculpture activity, also can disturb the beach morphology of intertidal bar systems. This phenomenon also was validated by comparison of beach morphology, the results of a color artificial tracer experiment and a sediment transportation trend prediction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

对当前卷烟厂制丝线计划与调度管理中存在的不足进行了介绍,并在建立制丝生产线生产过程模型的基础上,提出了用于解决问题的计划仿真系统,对所采用的仿真策略进行了详细介绍。采用这一策略实现的仿真系统能够很方便的适应于其他行业类型的仿真。