24 resultados para Measurable Multifunctions

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

For the design of radio frequency micro-electro-mechanical systems (RF MEMS) switches, the reliability issue becomes increasingly important. This paper represents some failure phenomena of doubly supported capacitive RF MEMS switches that include observable destruction failure and directly measurable parameter degradation obtained from the actuating-voltage testing and scanning electron microscope (SEM) observation. The relevant failure modes as well as their failure mechanisms are identified.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Porous Zr-based bulk metallic glass (PMG) with unidirectional opening pores is prepared by electrochemical etching of tungsten wires of the W/bulk metallic glass (BMG) composites. The porosity and pore size can be controlled by adjusting the tungsten wires. The PMG showed no measurable loss in thermal stability as compared to the monolithic Zr-based BMG by water quenching and is more ductile and softer than the pore-free counterpart. The specific surface area of the PMGs is calculated to be 0.65, 3.96, and 10.54 m(2)/kg for 20, 60, and 80 vol % porosity, respectively. (c) 2007 The Electrochemical Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By employing pump-probe back longitudinal diffractometry, the electron density and decay dynamics of a weak plasma channel created by a 1-KHz fs laser in air has been investigated. With ultrashort laser pulses of 50 fs and low energy of 0.6 mJ, we observe weak plasma channels with a length similar to 2 cm in air. An analytical reconstruction method of electron density has been analyzed, which is sensitive to the phase shift and channel size. The electron density in the weak plasma channel is extracted to be about 4x10(16) cm(-3). The diameters of the plasma channel and the filament are about 50 and 150 mu m, respectively, and the measurable electron density can be extended to less than 10(15) cm(-3). Moreover, a different time-frequency technique called linearly chirped longitudinal diffractometry is proposed to time-resolved investigate ultrafast ionization dynamics of laser-irradiated gas, laser interaction with cluster beam, etc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

在分析和综合其他数据处理方案优缺点的基础上,提出了一种基于分区查表法的有效数据处理方案.该方案先确定待处理的电压商值在三段近似线性曲线上所属区域,再执行查表法将其和微应变量一一对应.这种处理方案不但解决了传统单匹配解调技术中的双值和可测试范围小的问题,而且提高了测试准确度.根据实验结果,采用普通的光纤光栅对,系统可传感的应变范围可达525 με,准确度可达±1 με.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The key issues of engineering application of the dual gratings parallel matched interrogation method are expanding the measurable range, improving the usability, and lowering the cost by adopting a compact and simple setup based on existing conditions and improving the precision of the data-processing scheme. A credible and effective data-processing scheme based on a novel divisional look-up table is proposed based on the advantages of other schemes. Any undetermined data is belonged to a certain section, which can be confirmed at first, then it can be looked up in the table to correspond to microstrain by the scheme. It not only solves inherent problems of the traditional one (double value and small measurable range) but also enhances the precision, which improves the performance of the system. From the experimental results, the measurable range of the system is 525 mu epsilon, and the precision is +/- 1 mu epsilon based on normal matched gratings. The system works in real time, which is competent for most engineering measurement requirements. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

根据激光多普勒测振技术进行声光通信的工作原理,设计一种新型、小型激光多普勒测振信号鉴频电路。该电路根据外差探测原理,本地振荡器输出信号与探测信号混频得到一路信号,经90°移相后的本地振荡器输出信号再与探测信号混频得到另一路信号,利用这两路信号得到了多普勒频移量和声源振动的频率。利用扬声器激发的水面模拟振源进行实验,表明该电路可有效测量的振动频率范围为300 Hz~10 kHz,证明可用于水下光声通信。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

现代制造业对双频激光干涉仪的最大可测量速度提出了越来越高的要求。最大可测量速度是双频激光干涉仪的一项重要指标,它主要受双频激光光源所输出的频差、干涉仪的光学结构以及电子带宽等因素的限制。本文从理论和实验两方面对干涉仪的最大可测量速度进行了研究,搭建了基于自由落体运动的实验装置。实验结果表明,实际最大可测量速度略低于其理论值。另外,文中还分析了上述三种因素对最大可测量速度的影响。实验装置和结果可供工业应用提供参考。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

巨松鼠(Ratufa bicolor)是东洋界的特有类群.中国仅有一种,分布于海南、广西西南部、云南南部、西南部、西部和西北部,关于其亚种的分化结论过去主要依据其皮毛的颜色特征.本研究共测取75个巨松鼠头骨,每号头骨标本测取23个变量,运用统计分析软件SPSS 11.0对巨松鼠的可测量变量进行主成分分析、判别分析及聚类分析,以探讨巨松鼠各亚种地位的有效性及其头骨形态的地理学变异.研究结果显示阿萨姆亚种R.b.gigantea和海南亚种R.b.hainana均为有效亚种,前者分布自广西西南部向西经云南南部、西南部、西部达西北部,后者分布于海南.同时,本研究结果不支持滇南亚种R.b.stigmosa作为一个有效的亚种.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper describes the rapid and label-free detection of the white spot syndrome virus (WSSV) using a surface plasmon resonance (SPR) device based on gold films prepared by electroless plating. The plating condition for obtaining films suitable for SPR measurements was optimized. Gold nanoparticles adsorbed on glass slides were characterized by transmission electron microscopy (TEM). Detection of the WSSV was performed through the binding between WSSV in solution and the anti-WSSV single chain variable fragment (scFv antibody) preimmobilized onto the sensor surface. Morphologies of the as-prepared gold films, gold films modified with self-assembled alkanethiol monolayers, and films covered with antibody were examined using an atomic force microscope (AFM). To demonstrate the viability of the method for real sample analysis, WSSV of different concentrations present in a shrimp hemolymph matrix was determined upon optimizing the surface density of the antibody molecules. The SPR device based on the electroless-plated gold films is capable of detecting concentration of WSSV as low as 2.5 ng/mL in 2% shrimp hemolymph, which is one to two orders of magnitude lower than the level measurable by enzyme-linked immunosorbant assays. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A detailed study on analyzing the crosstalk in a wavelength division multiplexed fiber laser sensor array system based on a digital phase generated carrier interferometric interrogation scheme is reported. The crosstalk effects induced by the limited optical channel isolation of a dense wavelength division demultiplexer (DWDM) are presented, and the necessary channel isolation to keep the crosstalk negligible to the output signal was calculated via Bessel function expansion and demonstrated by a two serial fiber laser sensors system. Finally, a three-element fiber laser sensor array system with a 50-dB channel-isolation DWDM was built up. Experimental results demonstrated that there was no measurable crosstalk between the output channels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We study the entanglement degree of electron pairs emitted from an s-wave Superconductor, which Couples to two normal leads via a single-level quantum dot. Within the framework of scattering matrix theory. the concurrence is used to quantify the entanglement. And the result shows that the entanglement degree is generally influenced by the initial separation of the two electrons in a Cooper pair and the normal transmission eigenvalues T-1, T-2. But it is only determined by the eigenvalues in the tunnelling limit, T-1. T-2 << 1, what is more. it is measurable. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mechanical principles of fibre-optic disc accelerometers (FODA) different from those assumed in previous calculation methods are presented. An FODA with a high sensitivity of 82 rad/ g and a resonance frequency of 360 Hz is designed and tested. In this system, the minimum measurable demodulation phase of the phase-generated carrier (PGC) is 10(-5) rad, and the minimum acceleration reaches 120 ng theoretically. This kind of FODA, with its high responsivity, all-optic-fibre configuration, small size, light weight and stiff shell housing, ensures effective performance in practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The structural characteristic of cubic GaN (C-GaN) nucleation layers on GaAs(0 0 1) substrates by metalorganic chemical vapor deposition was in detail investigated first by X-ray diffraction (XRD) measurements, using a Huber five-circle diffractometer and an intense synchrotron X-ray source. The XRD results indicate that the C-GaN nucleation layers are highly crystallized. Phi scans and pole figures of the (1 1 1) reflections give a convincing proof that the GaN nucleation layers show exactly cubic symmetrical structure. The GaN(1 1 1) reflections at 54.74degrees in chi are a measurable component, however (002) components parallel to the substrate surface are not detected. Possible explanations are suggested. The pole figures of {1 0 (1) over bar 0} reflections from H-GaN inclusions show that the parasitic H-GaN originates from the C-GaN nucleation layers. The coherence lengths along the close-packed [1 1 1] directions estimated from the (1 1 1) peaks are nanometer order of magnitude. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electron cyclotron resonance CR) measurements have been carried out in magnetic fields up to 32 T to study electron-phonon interaction in two heavily modulation-delta -doped GaAs/Al0.3Ga0.7As single-quantum-well samples. No measurable resonant magnetopolaron effects were observed in either sample in the region of the GaAs longitudinal optical (LO) phonons. However, when the CR frequency is above LO phonon frequency, omega (LO)=E-LO/(h) over bar, at high magnetic fields (B>27 T), electron CR exhibits a strong avoided-level-crossing splitting for both samples at frequencies close to (omega (LO)+ (E-2-E-1)1 (h) over bar, where E-2, and E-1 are the energies of the bottoms of the second and the first subbands, respectively. The energy separation between the two branches is large with the minimum separation of 40 cm(-1) occurring at around 30.5 T. A detailed theoretical analysis, which includes a self-consistent calculation of the band structure and the effects of electron-phonon interaction on the CR, shows that this type of splitting is due to a three-level resonance between the second Landau level of the first electron subband and the lowest Landau level of the second subband plus one GaAs LO phonon. The absence of occupation effects in the final states and weak screening or this three-level process yields large energy separation even in the presence of high electron densities. Excellent agreement between the theory and the experimental results is obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Concentrations of the weakly oestrogenic degradation products of alkylphenol polyethoxylate (APE) surfactants (nonylphenol, octylphenol, nonylphenol monoethoxylate and nonylphenol diethoxylate) were measured in water and sediments from British rivers and estuaries collected during 1994 and 1995. In addition, a series of samples of tissues of wild fish from the River Aire, and from a laboratory dosing experiment were analysed for alkylphenols, to assess the degree of bioaccumulation of these compounds. Measurable concentrations of APE residues were recorded in the River Aire (15–76 μg/l total extractable alkylphenols), the River Mersey (6–11 μg/l) and the Tees estuary (up to 76 μg/l). These levels exceed, or are close to, the no observed effect concentration for the induction of vitellogenesis in caged trout (5–20 μg/l total extractable alkylphenols), and may be sufficient to exert an oestrogenic effect on fish populations in these areas. A sediment sample from Bingley on the River Aire contained 15 μg/g (dry weight) nonylphenol, and concentrations in sediments from the Tees and Mersey estuaries exceeded 1 μg/g. These rivers receive a variety of trade waters via sewage treatment works (STW) effluents containing significant concentrations of APE. Elsewhere, concentrations in water and sediments were near or below limits of detection and biological effects are unlikely, suggesting that any oestrogenic effects observed in sewage outfalls and rivers not directly impacted by APE-containing trade-waters may be caused by other chemicals. Analysis of samples of trout muscle taken from a tank dosed at 65 μg/l nonylphenol indicated a bioaccumulation factor of between 90 and 125 after 3 weeks exposure. Samples of wild fish from the River Aire contained up to 0.8 μg/g nonylphenol in the muscle, a tissue bioaccumulation factor of approximately 50 relative to measured concentrations in water samples. A series of fish samples taken from offshore for food quality assurance purposes contained no detectable levels of APE residues (0.05–0.1 μg/g nonylphenol).