6 resultados para Diagnostic Test Accuracy
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Five monoclonal antibodies (mAbs) against spring viraemia of carp (SVCV0504, isolated from common carp in China) were produced from mice immunized with purified virus preparations. The virion of SVCV contains five structural proteins, representing the nucleoprotein (N), phosphoprotein (P), matrix protein (M), glycoprotein (G) and RNA-dependent RNA polymerase (Q. Western blotting analysis revealed that three mAbs (1145, IE10, and 11-17) recognized specifically to a single protein of 47 kDa (N), the mAb 3G4 reacted with, two SVCV0504 proteins of 69 kDa (G) and 47 kDa (N), while the mAb 1A9 reacted with three SVCV0504 proteins of 69 kDa (G), 50 kDa (P), and 47 kDa (N). By indirect ELISA, two mAbs (1H5 and 11-17) showed cross-reactivity with pike fry rhabdovirus (PFRV), but no cross-reactions with the Siniperca chuatsi rhabdovirus (SCRV), Scophthalmus maximus rhabdovirus (SMRV), Paralichthys olivaceus rhabdovirus (PoRV) were demonstrated with the five mAbs. Indirect immunofluorescence showed intense fluorescence in the cytoplasm of the SVCV0504-infected epithelioma papulosum cyprini (EPC) cells in areas corresponding to the location of granular structures. The sucrose gradient-purified SVCV0504 particles could be detected successfully by these mAbs using immunodot blotting. mAb 1A9 could completely neutralize 100 TCID50 (50% tissue culture infective dose) of SVCV0504 at a dilution of 1:8. This is the first report of development of the neutralizing mAbs against SVCV. The mAb 1A9 was analyzed further and could be used to successfully detect viral antigens in the infected-EPC cell cultures or in cryosections from experimentally infected crucian carp (Carassius auratus) by immunohistochemistry assay. Furthermore, a flow cytometry procedure for the detection and quantification of cytoplasmic SVCV0504 in cell cultures was developed with mAb 1A9. At 28 h after inoculation with the virus (0.01 PFU/cell), 10.12% of infected cells could be distinguished from the uninfected cells. These mAbs will be useful in diagnostic test development and pathogenesis studies for fish rhabdovirus. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
在IBMJS21 Blade Center上进行2次HPCC测试,介绍HPCC的结果分析方法,并采用分层模型AHPCC对HPCC的测试结果进行分析。其目的是通过在高性能机群上执行HPCC测试说明HPCC测试对机群系统的评价和诊断能力。实验发现,在之前的HPL测试结果一直不理想并且无法更进一步发现和解决问题的情况下,采用HPCC测试能够较好地评价系统和诊断系统问题。通过分层模型的评价,能够得到更多关于目标系统的性能参数和发现可能的性能瓶颈,为系统设计及构建积累有价值的经验。
Resumo:
Based on the conventional through-short-match (TSM) method, an improved TSM method has been proposed in this Letter. This method gives an analytical solution and has almost all the advantages of conventional TSM methods. For example, it has no phase uncertainty and no bandwidth limitation. The experimental results show that the accuracy can be significantly improved with this method. The proposed theory can be applied to the through-open-match (TOM) method. (C) 2002 Wiley Periodicals. Inc.
Resumo:
The problem of frequency limitation arising in calibration of the test fixtures is investigated in this paper. It is found that at some frequencies periodically, the accuracy of the methods becomes very low, and. the denominators of the expressions of the required S-parameters approach zero. This conclusion can be drawn whether-the test fixtures, are symmetric or not. A good agreement between theory and experiment is obtained.
Resumo:
Two important factors that influence the force accuracy of the electromagnet-based nano-indenters but have not yet attracted much attention are analyzed, and a more reasonable way to estimate the force accuracy is presented in this paper. MTS Nano Indenter (R), with the characteristics of a coil suspended in a uniform magnetic field by two sets of springs acting as an actuator and force measuring unit, is used as an example. One of the two factors is the uniformity of the magnetic field. The other is the stiffness of the supporting spring. Consequently, the practical force accuracy varies considerably from test to test because it firmly depends on the working position of the coil and the displacement stroke. A reasonable estimated accuracy value is of the order of 10 degrees mu N for typical indentation tests with a 10(2) nm indentation depth or a 10 degrees mN test force. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
A bench scale reaction test for methane aromatization in the absence of an added oxidant was performed and its reaction result evaluated based on the carbon balance of the system. The result was compared with those obtained from the micro-reaction test to ensure the accuracy of the internal standard analyzing method employed in this paper. The catalytic performances of modified Mo/HZSM-5 catalysts were examined. It was found that pre-treatment by steam on HZSM-5 weakened the serious deposition of coke, and pre-impregnation of n-ethyl silicate on HZSM-5 could improve the conversion of CH4, but had little effect on coke formation. A low temperature activation procedure including pre-reduction of the catalyst with methane prevents the zeolite lattice from being seriously destroyed by high valence state Mo species when the Mo loading is high. It was suggested that Mo2C species detected by XRD spectra was the active phase for CH4 aromatization.