218 resultados para Boltzmann-Matano technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ultra-wide-band frequency response measurement system for optoelectronic devices has been established using the optical heterodyne method utilizing a tunable laser and a wavelenath-fixed distributed feedback laser. By controlling the laser diode cavity length, the beat frequency is swept from DC to hundreds GHz. An outstanding advantage is that this measurement system does not need any high-speed light modulation source and additional calibration. In this measurement, two types of different O/E receivers have been tested. and 3 dB bandwidths measured by this system were 14.4GHz and 40GHz, respectively. The comparisons between experimental data and that from manufacturer show that this method is accurate and easy to carry out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A V-shaped solar cell module consists of two tilted mono-crystalline cells [J. Li, China Patent No. 200410007708.6 (March, 2004)]. The angle included between the two tilted cells is 90 degrees. The two cells were fabricated by using polished silicon wafers. The scheme of both-side polished wafers has been proposed to reduce optical loss. Compared to solar cells in a planar way, the V-shaped structure enhances external quantum efficiency and leads to an increase of 15% in generation photocurrent density. The following three kinds of trapped photons are suggested to contribute to the increase: (1) infrared photons converted from visible photons due to a transformation mechanism, (2) photons reflected from top contact metal, and (3) a residual reflection which can not be eliminated by an antireflection coating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enhanced technique for interrogating fiber Bragg grating wavelength shift using cascade wavelength division multiplexer (WDM) couplers was proposed and demonstrated. Three WDM couplers which show a linear filter function over the expected wavelength range are employed and cascaded to track Bragg wavelength shifts. Compared with single WDM demodulator. sharper spectral slope is obtained and considerable linear filter range is kept. The static and dynamic strain sensor demodulation experiments demonstrated that the simple passive technique improves the sensitivity approximately two times and keeps 5nm linear demodulation range based on our devices. The cascade WDM coupler demodulation system has high scan rate which can be used to monitor fast vibration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A practical package technique for temperature independent Fiber Bragg grating sensor is proposed. A uniform strength cantilever with two FBG attached on the upper and lower surfaces was utilized as the key element. By detecting two wavelengths differential output, the applied force can be obtained and temperature effects can be eliminated. Experiment results show the sensor has linear response and output signal uctuates less than 12pm as temperature changes from -10 degrees C to 50 degrees C. The maximum thermal error is less than 0.3% of the full measurement range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The time delay for light transmission in a coupled microring waveguide structure is calculated from the phase shift of the transmission coefficient obtained by Pade approximation with Baker's algorithm from FDTD Output. The results show that the Pade approximation is a powerful tool for saving time in FDTD simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a smart frequency presetting technique for fast lock-in LC-PLL frequency synthesizer. The technique accurately presets the frequency of VCO with small initial frequency error and greatly reduces the lock-in time. It can automatically compensate preset frequency variation with process and temperature. A 2.4GHz synthesizer with 1MHz reference input was implemented in 0.35 mu m CMOS process. The chip core area is 0.4mm(2). Output frequency of VCO ranges from 2390 to 2600MHz. The measured results show that the typical lock-in time is 3 mu s. The phase noise is -112dBc/Hz at 600KHz offset from center frequency. The test chip consumes current of 22mA that includes the consumption of the I/O buffers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

引入了一种二元Lattice Boltzmann Model(LBM),实现了两种液体组成的混合流的模拟.不同于其它的类似模型,它区分考虑了流体的粘性和扩散特性,可以很容易地模拟各种互溶或者不互溶的混合流现象.此外,由于LBM的运算大都是线性的局部运算,这使得它很容易在可编程图形处理器(Graphics Process Unit,GPU)上进行加速,从而进行实时模拟.给出了若干二元混合流的模拟结果.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A technique is presented for ascertaining when a (finite-state) partial process specification is adequate, in the sense of being specified enough, for contexts in which it is to be used. The method relies on the automatic generation of a modal formula from the partial specification; if the remainder of the network satisfies this formula, then any process that meets the specification is guaranteed to ensure correct behavior of the overall system. Using the results, the authors develop compositional proof rules for establishing the correctness of networks of parallel processes and illustrate their use with several examples

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An automatic step adjustment (ASA) method for average power analysis (APA) technique used in fiber amplifiers is proposed in this paper for the first time. In comparison with the traditional APA technique, the proposed method has suggested two unique merits such as a higher order accuracy and an ASA mechanism, so that it can significantly shorten the computing time and improve the solution accuracy. A test example demonstrates that, by comparing to the APA technique, the proposed method increases the computing speed by more than a hundredfold under the same errors. By computing the model equations of erbium-doped fiber amplifiers, the numerical results show that our method can improve the solution accuracy by over two orders of magnitude at the same amplifying section number. The proposed method has the capacity to rapidly and effectively compute the model equations of fiber Raman amplifiers and semiconductor lasers. (c) 2006 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In scattering calculations using the T-matrix method, the calculation of the T-matrix involves multiplication and inversion of matrices. These two types of matrix operations are time-consuming, especially for the matrices with large size. Petrov et al. [D. Petrov, Y. Shkuratov, G. Videen, Opt. Lett. 32 (2007) 1168] proposed an optimized matrix inversion technique, which suggests the inversion of two matrices, each of which contains half the number of rows. This technique reduces time-consumption significantly. On the basis of this approach, we propose another fast calculation technique for scattering in the T-matrix method, which obtains the scattered fields through carrying out only the operations between matrices and the incident field coefficient. Numerical results show that this technique can decrease time-consumption by more than half that of the optimized matrix inversion technique by Petrov et al. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Residual defects in the overlayer of fully annealed SIMOX material have been studied by means of a chemical etching technique. The etching procedure has been calibrated and an optimum recipe is reported. Observations using optical microscopy and transmission electron microscopy have been used to quantify the defect densities and good agreement between the two techniques has been established, confirming that the optimised chemical etching process can be used with confidence to determine the dislocation density for values < 10(7) cm-2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of metastable defects caused by light soaking and carrier injection on the transport of carriers in undoped a-Si:H has been investigated by a junction recovery technique. The experiments show that after light soaking or carrier injection the product of mu-p-tau-p decreases, but no detectable change in the distribution of shallow valence band tail states was found.