155 resultados para SMA wire actuator
Resumo:
给出配置了环形线电极的单极机中的磁流体力学解析解.由于问题是线性的,求解可简化为基本解的叠加,可利用单极机在两个区域中的基本解的衔接来求得解析解.讨论了基本解的性质.利用非完全电极可改善Hartmann边界层、增加装置中的质量流量.应用基本解讨论了连续电极的单极机.
Resumo:
A noncontacting and noninterferometric depth discrimination technique, which is based on differential confocal microscopy, was used to measure the inverse piezoelectric extension of a piezoelectric ceramic lead zirconate titanate actuator. The response characteristics of the actuator with respect to the applied voltage, including displacement, linearity, and hysteresis, were obtained with nanometer measurement accuracy. Errors of the measurement have been analyzed. (C) 2001 Society of Photo-Optical Instrumentation Engineers.
Resumo:
We report an experiment of trapping of neutral Rb-87 atoms on a, self-made atomchip. The H-shaped atomchip is made by magnetron sputtering technology, which is different from the atomchip technology of other teams. We collect 3 x 10(6) Rb-87 atoms in the mirror magneto-optical trap (MOT) using the external MOT coils, and 1 X 10(5) Rb-87 atoms are transferred to U-MOT using U-shaped wire in chip and a pair of bias coils.
Resumo:
利用解析和数值方法计算了Z形磁阱的囚禁势,发现当囚禁中心和芯片表面距离较远时(该距离和Z形线中部导线的一半长度相差不超过一个量级),势阱的深度不能近似表示成偏置磁场By对应的能量,而要减去囚禁中心的势能高度;而增加By进行磁阱压缩到一定值时,势阱深度反而会下降.此外介绍了原子芯片的制作方法,以及利用原子芯片上Z形磁阱囚禁中性87Rb原子的实验装置和实验过程.最终有2×10^6个^87Rb原子被转移到Z形磁阱中.
Resumo:
We demonstrate the guiding of neutral atoms with two parallel microfabricated current-carrying wires on the atom chip and a vertical magnetic bias field. The atoms are guided along a magnetic field minimum parallel to the current-carrying wires and confined in the other two directions. We describe in detail how the precooled atoms are efficiently loaded into the two-wire guide. We present a detailed experimental study of the motional properties of the atoms in the guide and the relationship between the location of the guide and the vertical bias field. This two-wire guide with vertical bias field can be used to realize large area atom interferometer.
Resumo:
A planar waveguide ring resonator was fabricated by organic-inorganic hybrid sol-gel materials; its sensitivity to ethanol vapor was experimentally investigated. It was found that dips in the transmission spectrum of the device shifted to longer wavelengths with increasing the ethanol concentration, and its sensitivity showed a linear relation with the ethanol concentration, showing a coefficient of 1.13 pm/ppm. In addition, the transmission loss of the ring resonator decreased with increasing the ethanol concentration. The measured characteristics suggest that the device may be considered as one of the candidates of alcohol vapor sensors. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
报道了基于双面反射镜的N×N光开关器件。介绍了使用双面反射镜的2×2, 4×4光开关的集成光路设计和工作原理; 采用Benes网络, 以2×2和4×4光开关为基本单元的N×N光开关器件的整体结构, 并根据“一笔画”原理, 分析了4×4, 8×8和16×16光开关矩阵的可重排无阻塞特性和光开关矩阵的光路选择算法。最后, 基于2×2, 4×4光开关技术制备了16×16光开关矩阵。测试表明, 该器件具有良好的插入损耗、回波损耗、串扰和开关时间等性能, 从而验证了设计思想和工艺的可行性。在基于双面反射镜的光开关矩
Resumo:
This paper presents the design and characterization of a fiber Fabry-Perot interferometer (FFPI) acoustic wave detector with its Q point being stabilized actively. The relationship between the reflectivity of the F-P cavity facets and cavity length was theoretically analyzed, and high visibility of 100% was realized by optimized design of the F-P cavity. To prevent the drifting of the Q point, a new stabilization method by actively feedback controlling of the diode laser is proposed and demonstrated, indicating the method is simple and easy operating. Measurement shows that good tracing of Q point was effectively realized. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
压电驱动器的位移输出能力有限,因此通常借助于柔性机构对其位移量进行放大。对常用的柔性放大机构的性能进行了分析。提出一种柔性八杆放大机构,并对其进行有限元分析和理论计算。为了提高放大率,提出两级串连式机构。机构整体具有结构紧凑、放大效率较高的优点。
Resumo:
提出一种新型的五自由度精密定位平台的工作原理及其设计方法。工作台采用压电陶瓷作为驱动元件,柔性导向机构实现平移及转动功能。整个工作台可由整块金属材料通过线切割加工制成,实现一体化加工,而且结构紧凑。并给出导向机构刚度计算公式及设计实例。
Resumo:
从掺镱(Yb)光纤放大器的功率传输方程出发,利用有限差分法对小模场面积(SMA)和大模场面积(LMA)掺镱双包层光纤放大器的放大特性进行了分析比较。采用模场直径(MFD)6.5 μm和20 μm的双包层掺镱光纤作为放大器增益介质进行窄线宽连续信号的放大,在915 nm激光抽运下模拟计算了大、小模场面积输出功率随输入信号功率、抽运光功率和光纤长度的变化特性,特别是对于大模场面积光纤放大器,最优光纤长度的选择至关重要;讨论了模场直径不同时的最优抽运功率和光纤长度的选择,得出4 m光纤放大时的临界抽运功率为4
Resumo:
A kind of 1,6,10,15,19,24,28,33-octa-iso-pentyloxy-2,3-metallonaphthalocyanines complexes MNc(iso-PeO)(8) (M = Co, Cu, Pd) are used as spincoating film-forming materials. The surface morphologies of the films prepared were studied first. These films were then used for the experiments of NO2 sensing. The effects of sensing temperature as well as the NO concentration on the sensing properties were studied. The experimental results showed that the three MNc(iso-PeO)(8) films were uniform, smooth and dense. Due to the different metal ions (M) on the center of naphthalocyanine, the CoNc(iso-PeO)(8) film had a higher film resistance and response-recovery rate in the NO2 sensing experiments. On the contrary, the response to NO2 of the PdNc(iso-PeO)(8) and CuNc(iso-PeO)(8) films were superior to that of CoNc(iso-PeO)(8). By varying the sensing temperature, it was found that the elevation of sensing temperature could improve the sensing response, recovery ratio, and sensitivity of the sensing films. At high concentrations of NO2, the response time became shorter. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
A spin-coated film of lead tetra-(tert-butyl)-5,10,15,20-tetraazaporphyrin complex (PbTAP(t-Bu)(4)) was obtained and characterized by IR spectra, absorption spectra and atomic force microscopy. The response and recovery characteristics of the film to NH3, NO2 and C2H5OH vapor were investigated at room temperature. In addition, the reversibility and stability of the film to NH3 were also studied. The results indicate that the PbTAP(t-Bu)(4) derivative can be exploited as an NH3 sensor at room temperature. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
实验研究了腔内位相锁定来至一LAD侧面抽运的Nd:YAG板条的两束激光,输出镜面出现干涉条纹,获得1.13W的相干光,其组束效率达到64.9%,相干度约60%。实验中发现只需要一根作为滤波的金属丝放在离输出镜合适的位置都就能有效稳定干涉条纹,金属丝引起的损耗低于8%。
Resumo:
Up-converting phosphor technology (UPT)-based lateral-flow immunoassay has been developed for quantitative detection of Yersinia pestis rapidly and specifically. In this assay, 400 nm up-converting phosphor particles were used as the reporter. A sandwich immumoassay was employed by using a polyclonal antibody against F1 antigen of Y. pestis immobilized on the nitrocellulose membrane and the same antibody conjugated to the UPT particles. The signal detection of the strips was performed by the UPT-based biosensor that could provide a 980 nm IR laser to excite the phosphor particles, then collect the visible luminescence emitted by the UPT particles and finally convert it to the voltage as a signal. V-T and V-c stand for the multiplied voltage units for the test and the control line, respectively, and the ratio V-T/V-C is directly proportional to the number of Y pestis in a sample. We observed a good linearity between the ratio and log CFU/ml of Y pestis above the detection limit, which was approximately 10(4) CFU/mI. The precision of the intra- and inter-assay was below 15% (coefficient of variation, CV). Cross-reactivity with related Gram-negative enteric bacteria was not found. The UPT-LF immunoassay system presented here takes less than 30 min to perform from the sample treatment to the data analysis. The current paper includes only preliminary data concerning the biomedical aspects of the assay, but is more concentrated on the technical details of establishing a rapid manual assay using a state-of-the-art label chemistry. (c) 2006 Elsevier B.V. All rights reserved.