112 resultados para Air-flow Rate


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The paper reports a method of depositing SiO2, SiNx, a:Si, Si3N4 and SiOxNy dielectric thin films by electron cyclotron resonance plasma chemical vapor deposition (ECR CVD) on InP, InGaAs and other compound semiconductor optoelectronic devices,and give a technology of depositing dielectric thin films and optical coatings by ECR CVD on Laser's Bars. The experiment results show the dielectric thin films and optical coatings are stable at thermomechanical property,optical properties and the other properties. In addition, the dielectric thin film deposition that there is low leakage current is reported for using as diffusion and ion implatation masks in the paper. In the finally, the dielectric film refractive index can be accurately controlled by the N-2/O-2/Ar gas flow rate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A series of systematic experiments on the growth of high quality GaNAs strained layers on GaAs (001) substrate have been carried out by using DC active Nz plasma, assisted molecular beam epitaxy. The samples of GaNAs between 3 and 200 nm thick were evaluated by double crystal X-ray diffraction (XRD) and photoluminescence (PL) measurements. PL and XRD measurements for these samples are in good agreement. Some material growth and structure parameters affecting the properties of GaNAs/GaAs heterostructure were studied; they were: (1) growth temperature of GaNAs epilayer; (2) electrical current of active N-2 plasma; (3) Nz flow rate; (4) GaNAs growth rate; (5) the thickness of GaNAs strained layer. XRD and PL measurements showed that superlattice with distinct satellite peaks up to two orders and quantum well structure with intensity at 22 meV Fourier transform infrared spectroscopy (FWHM) can be achieved in molecular beam epitaxy (MBE) system. (C) 2000 Published by Elsevier Science S.A. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Experimental study of a liquid fed direct methanol fuel cell has been conducted in different gravity environments. A small single cell with 5 cm x 5 cm active area has single serpentine channel on the graphite cathode polar plate and 11 parallel straight channels on the graphite anode flow bed. Cell voltage and current have been measured and two-phase flow in anode channels has been in situ visually observed. The experimental results indicate that the effect of gravity on power performance of the direct methanol fuel cell is large when the concentration polarization governs fuel cells operation. Gravitational effect becomes larger at higher current density. Increasing methanol feeding molarity is conducive to weaken the influence of gravity on performance of liquid fed direct methanol fuel cells. Increasing feeding flow rate of methanol solution from 6 to 15 ml/min could reduce the size of carbon dioxide bubbles, while the influence of gravity still exist. Transport phenomena inside direct methanol fuel cells in microgravity is also analyzed and discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

使用FLUENT软件, 对水冷火电厂的水冷塔换热进行了数值模拟, 解决了物模实验难以模拟热力因素的困难. 同时还对采用"空气涡流导引装置技术"的水冷塔和传统水冷塔, 在不同环境风影响下的换热效率进行了对比. 结果表明, 采用"空气涡流导引装置技术"的水冷塔换热效果优于传统水冷塔, 抵抗大风的能力更强

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Salt water intrusion occurred frequently during dry season in Modaomen waterway of the Pearl River Estuary. With the development of region's economy and urbanization, the salt tides affect the region's water supply more and more seriously in recent years. Regulation and allocation of freshwater resources of the upper rivers of the estuary to suppress the salt tides is becoming important measures for ensuring the water supply security of the region in dry season. The observation data analysis showed that the flow value at the Wuzhou hydrometric station on the upper Xijiang river had a good correlation with the salinity in Modaomen estuary. Thus the flow rate of Wuzhou has been used as a control variable for suppression of salt tides in Modaomen estuary. However, the runoff at Wuzhou mainly comes from the discharge of Longtan reservoir on the upper reaches of Xijiang river and the runoff in the interval open valley between Longtan and Wuzhou sections. As the long distance and many tributaries as well as the large non-controlled watershed between this two sections, the reservoir water scheduling has a need for reasonable considering of interaction between the reservoir regulating discharge and the runoff process of the interval open watershed while the deployment of suppression flow at Wuzhou requires longer lasting time and high precision for the salt tide cycles. For this purpose, this study established a runoff model for Longtan - Wuzhou interval drainage area and by model calculations and observation data analysis, helped to understand the response patterns of the flow rate at Wuzhou to the water discharge of Longtan under the interval water basin runoff participating conditions. On this basis, further discussions were taken on prediction methods of Longtan reservoir discharge scheduling scheme for saline intrusion suppression and provided scientific and typical implementation programs for effective suppression flow process at the Wuzhou section.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Using an oscilloscope, a high-speed video camera and a double-electrostatic probe system, the periodicity and amplitude of the fluctuations in arc voltage, jet luminance and ion saturation current of a plasma jet were monitored to investigate various sources of instabilities and their effects in a non-transferred dc plasma torch operated at reduced pressure. The results show that besides a 300 Hz main fluctuation inherited from the power supply, arc voltage fluctuation of 3–4 kHz with an amplitude less than 5% of the mean voltage was mainly affected by the total gas flow rate. The arc voltage fluctuation can affect the energy distribution of the plasma jet which is detectable by electrostatic probes and a high-speed video camera. The steadiness of energy transfer is also affected by the laminar or turbulent flow state of the plasma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

环境突发污染事故给人民生活、经济发展和生态环境造成重大影响,研究污染物泄漏造成河流突发污染事故的应急处理方法十分必要。本论文选取苯酚、苯胺和亚甲基蓝等典型污染物为实验对象,采用吸附容量大、密度与水接近的活性炭纤维(ACF)为吸附剂。在自制的河流模型中,研究了ACF以苯酚、苯胺和亚甲基蓝为典型污染物的吸附过程,考察了吸附剂投加量、污染物浓度、吸附剂比表面积、吸附剂投加方式、水流速度与水质等对吸附速率与吸附效果的影响。实验结果表明,ACF能以较快的速率吸附苯酚、苯胺和亚甲基蓝,吸附率都在95%以上; ACF投加量是影响吸附速率最重要的因素,当一次性投加ACF质量之比为 1:2:4时,吸附速率常数之比近似为1:2:4;污染物浓度对吸附速率的影响显著,浓度较低时吸附速率较高。苯酚初始浓度为7mg·L-1时,经过86分钟的吸附,处理后的浓度可以达到地表水Ⅴ类水中挥发酚的限值要求(0.1mg·L-1);在吸附11分钟左右追加适量的ACF,能够明显提高吸附速率;河水流速和河流中的天然有机物、浊度、河水硬度对ACF吸附都不产生显著影响,这说明ACF作为河流突发污染事故应急处理的吸附剂,有广泛的适应性。在实际河水中,ACF对苯酚的吸附过程与在模拟河水中相似,吸附效果显著。实验结果还表明,ACF对苯酚的吸附是放热反应,符合Freundlich模型和Langmuir模型。事故应急处理后,应该及时将吸附了污染物的ACF打捞上来,有利于进行后续处理。 Emergency environmental pollution accidents pose significant impacts on our living, economic development and ecological environment. The study on the approach of emergency control for the contingency caused by leakage of pollutants in rivers is very necessary. In the experiment, phenol, aniline and methylene blue were selected as representative pollutant and activated carbon fiber (ACF) was selected as adsorbent, which has strong adsorption capacity and similar density to water. In the self-made river model, the effects of ACF dosage, pollutant concentration, ACF surface area, ACF adding ways, water flow rate and water quality on adsorption courses were investigated. The experimental results showed that ACF could adsorb pollutant quickly and effectively. The ACF dosage was the most important factor that affected adsorption rate .When the ACF dosage rate was 1:2:4, the constants of adsorption rate was approximately 1:2:4. The effect of pollutant concentrations on the adsorption rate was notable. Faster adsorption rates were achieved at low pollutant concentrations. Phenol concentration reached the limits of volatile phenol in Category Ⅴ surface water (0.1 mg·L-1) after 86 minutes of adsorption with initial phenol concentration of 7 mg·L-1. After 11 minutes of adsorption, certain amount of ACF was added and the adsorption rate was improved significantly. River flow rate and water quality have little effect on the adsorption rate. The adsorption results obtained in actual river water were comparable with that in simulating river water. The results also showed that, ACF on the absorption of phenol is exothermic reaction, witch matched with the Freundlich model and the Langmuir model. After emergency treatment, the ACF absorbed pollutants should be promptly salvaged for follow-up treatment.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A packed-bed electroosmotic pump (EOP) was constructed and evaluated. The EOP consisted of three capillary columns packed in parallel, a gas-releasing device, Pt electrodes and a high-voltage power supply. The EOP could generate output pressure above 5.0 MPa and constant flow rate in the range of nl/min to a few mul/min for pure water, pure methanol, 2 mM potassium dihydrogenphosphate buffer, the buffer-methanol mixture and the pure water-methanol mixture at applied potentials less than 20 W The composition of solvent before/after pumping was quantitatively determined by using a gas chromatograph equipped with both flame ionization detector and thermal conductivity detector. It was found that there were no apparent changes in composition and relative concentrations after pumping process for a methanol-ethanol-acetonitrile mixture and a methanol-water mixture. Theoretical aspect of the EOP was discussed in detail. An capillary HPLC system consisting of the EOP, an injection valve, a 15 cm x 320 mum i.d., 5 mum Spherigel C(18) stainless steel analytical column, and an on-column UV detector was connected to evaluate the performance of the EOP. A comparative study was also carried out with a mechanical capillary HPLC pump on the same system. The results demonstrated that the reproducibility of flow rate and the pulsation-free flow property of the EOP are superior to that of mechanical pump in capillary HPLC application. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Three molecularly imprinted monolithic columns with different length but almost identical column volume had been prepared. It was observed that the separation factors of diastereomers and enantiomers were almost unaffected by column length. However, the short column with dimension of 38 mm x 8 mm W. showed much lower resistance to flow rate so that it could be operated at much higher flow rates. By combining stepwise gradient elution with elevated flow rate, the diastereomers of cinchonine and cinchonidine and the enantiomers of Cbz-DL-Trp and Fmoc-DL-Trp were successfully separated within 3 min on the short column with dimension of 38 mm. x 8 mm i.d.. Based on the above results, a cinchonine imprinted monolithic disk with dimension of 10 mm x 16 mm W. was further developed. The SEM image and the pore size distribution profile showed that large flow-through pores are present on the prepared monolith, which allowed mobile phase to flow through the disk with very low resistance. Chromatographic performances on the monolithic disk were almost unchanged compared with the long columns. A rapid separation of cinchonine and cinchonidine was achieved in 2.5 min at the flow rate of 9.0 ml/min. Furthermore, it was observed that there was almost no effect of the flow rate on the dynamic binding capacity at high flow rates. In addition, the effect of the loading concentration of analytes on the dynamic binding capacity, namely adsorption isotherm, was also investigated. A non-linear adsorption isotherm of cinchonine was observed on the molecularly imprinted monolith with cinchonine as template, which might be a main reason to result in the peak tailing of template molecule. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An electroosmotic pump (EOP) capable of generating pressure above 3 MPa and mul/min flow rate with reverse phase mobile phases of HPLC was constructed and evaluated. The pump consisted of three parallel connected fused silica capillary columns (25 cm x 320 mum I.D.) packed with 2 mum silica materials, hollow electrodes, a high voltage DC power supply, and. a liquid pressure transducer. The EOP was applied in a capillary liquid chromatographic system for mobile phase delivery instead of a mechanical pump. Standard samples containing thiourea, naphthalene, anthracene, phenanthrene and acetonitrile were separated on a 15 cm x 320 mum I.D. 5 mum Chromasil C-18 packed capillary column with acetonitrile/water as mobile phase. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Direct synthesis of alcohols from CO and H2O was investigated using TiO2 catalyst. MeOH (about 24 mg g(-1) h(-1)) and EtOH (about 8 mg g(-1) h(-1)) could be produced under the reaction conditions of T= 573 K, P= 0.5 MPa, CO flow rate of 30 ml min(-1) and CO/H2O = 3/2 during the period of 12 to 44 h time-on-stream. Compared with PbO, TiO2 could preserve stable catalytic activity during a long time of reaction. For the same catalyst TiO2, the reaction performance of alkali carbonates increased with their solubility (K2CO3>Na2CO3>Li2CO3). The corresponding catalytic activity was found to increase with the alkalescence of solvent. The formation mechanism of alcohols was proposed as well. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The reaction performance for CO hydration on a TiO2 catalyst under different calcination temperatures was investigated. Under reaction conditions of T = 573 K, P = 0.5 MPa, CO flow rate of 30 ml min(-1), TOS = 12 h, and CO/H2O (g) = 3/2 (mol), the TiO2 catalyst with a futile content of 18% shows a maximum alcohols STY of 1.81 Mg m(-2) h(-1). In addition, the catalyst deactivation and regeneration were discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The environmentally friendly removal of NO has been investigated using continuous microwave discharge (CMD) at atmospheric pressure. In these experiments, conversions of NO to N-2 as well as NO2 were mainly observed for both dry and wet feed gas, which showed a great difference from those observed with other discharge methods. The effects of a series of reaction parameters, including microwave input power, O-2 concentration, NO concentration, and gas flow rate, on the product distribution and energy efficiency were also studied. Under all reaction conditions, the conversions of NO to N-2 were higher than those to NO2. The highest conversion of NO to N-2 was 88%. The reaction rate of NO removal and the effects of the different discharge modes on NO conversion and product distribution are also discussed. Through comparison of the results of different discharge modes, it was found that the addition of CH4 apparently increased the conversion of NO to N-2 as well as the energy efficiency. A possible reaction process is suggested.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The suitability of membrane cartridges for the removal of endotoxin from both distilled water and interferon preparations was examined. The endotoxin concentrations were reduced to 4.0 and 7.3 EU/ml, respectively, when about 4000 ml of distilled water with 20 and 28 EU/ml were passed through the deoxycholate and chitosan immobilized membrane cartridges. When 200 ml of interferon preparation with endotoxin concentration more than 80 EU/ml and pH 3.9 were applied to a deoxycholate immobilized membrane cartridge at a flow-rate of 9 ml/min, the endotoxin concentration was reduced to less than 10 EU/ml. However, if an interferon preparation of 450 ml, with more than 80 EU/ml of endotoxin and pH 3.9 was applied to the chitosan immobilized membrane cartridge at a flow-rate of 18 ml/min, the endotoxin concentration was reduced to less than 10 EU/ml. (C) 2003 Elsevier Science B.V. All rights reserved.