Instabilities in a non-transferred direct current plasma torch operated at reduced pressure
Data(s) |
12/02/2010
|
---|---|
Resumo |
Using an oscilloscope, a high-speed video camera and a double-electrostatic probe system, the periodicity and amplitude of the fluctuations in arc voltage, jet luminance and ion saturation current of a plasma jet were monitored to investigate various sources of instabilities and their effects in a non-transferred dc plasma torch operated at reduced pressure. The results show that besides a 300 Hz main fluctuation inherited from the power supply, arc voltage fluctuation of 3–4 kHz with an amplitude less than 5% of the mean voltage was mainly affected by the total gas flow rate. The arc voltage fluctuation can affect the energy distribution of the plasma jet which is detectable by electrostatic probes and a high-speed video camera. The steadiness of energy transfer is also affected by the laminar or turbulent flow state of the plasma. |
Identificador | |
Idioma(s) |
英语 |
Fonte |
Journal of Physics D: Applied Physics.2010,43(8):085202 |
Palavras-Chave | #交叉与边缘领域的力学 #ATMOSPHERIC-PRESSURE #ARC #JETS #FLUCTUATIONS #GENERATION #LAMINAR |
Tipo |
期刊论文 |