95 resultados para platelet distribution width
Resumo:
An experimental study on the angular distribution and conversion of multi-keV X-ray sources produced from 2 ns-duration 527nm laser irradiated thick-foil targets on Shenguang II laser facility (SG-II) is reported. The angular distributions measured in front of the targets can be fitted with the function of f(theta) = alpha+ (1- alpha)cos(beta) theta (theta is the viewing angle relative to the target normal), where alpha = 0.41 +/- 0.014, beta = 0.77 +/- 0.04 for Ti K-shell X-ray Sources (similar to 4.75 keV for Ti K-shell), and alpha = 0.085 +/- 0.06, beta = 0.59 +/- 0.07 for Ag/Pd/Mo L-shell X-ray Sources (2-2.8 keV for Mo L-shell, 2.8-3.5 keV for Pd L-shell, and 3-3.8 keV for Ag L-shell). The isotropy of the angular-distribution of L-shell emission is worse than that of the K-shell emission at larger viewing angle (>70 degrees), due to its larger optical depth (stronger self-absorption) in the cold plasma side lobe Surrounding the central emission region, and in the central hot plasma region (emission region). There is no observable difference in the angular distributions of the L-shell X-ray emission among Ag, Pd, and Mo. The conversion efficiency of Ag/Pd/Mo L-shell X-ray sources is higher than that of the Ti K-shell X-ray sources, but the gain relative to the K-shell emission is not as high as that by using short pulse lasers. The conversion efficiency of the L-shell X-ray sources decrease, with increasing atomic numbers (or X-ray photon energy), similar to the behavior of the K-shell X-ray Source.
Resumo:
We report micromodification of Eu element distribution in a silicate glass with femtosecond laser irradiation. Elemental analysis shows that the content of Eu decreased at the focal point and increased in a ring-shaped region around the focal point, which indicates migration of Eu ions has been induced by the femtosecond laser irradiation. Confocal fluorescence spectra demonstrate that the fluorescence intensity of Eu3+ ions increased by 20% in the laser-induced, Eu-enriched, ring-shaped region compared with that for nonirradiated glass. The mechanism for the laser induced change in fluorescence properties of Eu3+ has been investigated. (C) 2009 Optical Society of America
Resumo:
Linear Thomson scattering of a short pulse laser by relativistic electron lids been investigated using computer simulations. It is shown that scattering of an intense laser pulse of similar to 33 fs full width at half maximum, with an electron of gamma(o) = 10 initial energy, generates an ultrashort, pulsed radiation of 76 attoseconds, with a photon wavelength of 2.5 nm in the backward direction. The scattered radiation generated by a highly relativistic electron has superior quality in terms of its pulse width and angular distribution in comparison to the one generated by lower relativistic energy electron.
Resumo:
Linear Thomson scattering by a relativistic electron of a short pulse laser has been investigated by computer simulation. Under a laser field with a pulse of 33.3-fs full-width at half-maximum, and the initial energy of an electron of gamma(0) = 10, the motion of the electron is relativistic and generates an ultrashort radiation of 76-as with a photon wave length of 2.5-nm in the backward scattering. The radiation under a high relativistic energy electron has better characteristic than under a low relativistic energy electron in terms of the pulse width and the angular distribution. (c) 2005 Elsevier GrnbH. All rights reserved.
Resumo:
This paper deals with the distribution of generated microcrystallites in borate glass irradiated by 120 fs laser pulses at a central wavelength of 800 nm. Raman spectroscopy is used to investigate the distribution of the high and low temperature phases of barium metaborate crystals generated in the borate glass. In combination with a microexplosion model, bond-breaking induced by laser irradiation is served as the origin of the formation of BBO crystals. Depending on the laser fluence and cooling conditions, the distribution mechanisms have been discussed. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
An optimal feedback control of broadband frequency up-conversion in BBO crystal is experimentally demonstrated by shaping femto-second laser pulses based on genetic algorithm, and the frequency up-conversion efficiency can be enhanced by similar to 16%. SPIDER results show that the optimal laser pulses have shorter pulse-width with the little negative chirp than the original pulse with the little positive chirp. By modulating the fundamental spectral phase with periodic square distribution on SLM-256, the frequency up-conversion can be effectively controlled by the factor of about 17%. The experimental results indicate that the broadband frequency up-conversion efficiency is related to both of second harmonic generation (SHG) and sum frequency generation (SFG), where the former depends on the fundamental pulse intensity, and the latter depends on not only the fundamental pulse intensity but also the fundamental pulse spectral phase. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
利用二维耦合波理论,分析了超短脉冲激光光束被完全重叠型的局域体全息光栅衍射的时空变化性质,给出了衍射和透射脉冲激光光束沿光栅出射边界的强度时空分布。以LiNbO3晶体为例,数值研究了衍射光脉冲强度沿光栅出射边界的分布和脉冲波形的变化及光栅的总衍射效率受光栅二维尺寸、入射角度、光栅折射率调制度及入射脉冲的脉冲时域半峰全宽等条件的影响而变化的情况。与一维体全息光栅对超短脉冲激光光束衍射的性质,及此光栅对连续光衍射的性质作比较,给出了合理选择光栅参量及入射条件以在光栅出射边界上得到总衍射效率较大且分布较均匀的衍
Resumo:
A theoretical study of the behaviour of partially coherent beams propagating through oceanic turbulence has been performed. Based on the previously developed knowledge of beam spreading of a partially coherent beam in the atmosphere and the spatial power spectrum of the refractive index of ocean water, we study the normalized root-mean-square width of a partially coherent beam on propagation through oceanic turbulence and its turbulence distance which may be a measure of turbulence resistance. Our analysis indicates that the behaviour of partially coherent beams on propagation may be described by the rate of dissipation of the mean-squared temperature chi(T) and that of salinity chi(S). In terms of a quantity w that defines the contributions of the temperature and salinity distributions to the distribution of the refractive index, chi(S) could be written as a function of chi(T) and w. Therefore, the behaviour of partially coherent beams on propagation can be characterized only by chi(T) for a given w. The results are shown for curved surfaces, from which one can see that partially coherent beams exhibit robust turbulence resistance when the water volume has a smaller chi(T).
Resumo:
We describe the use of a Wigner distribution function approach for exploring the problem of extending the depth of field in a hybrid imaging system. The Wigner distribution function, in connection with the phase-space curve that formulates a joint phase-space description of an optical field, is employed as a tool to display and characterize the evolving behavior of the amplitude point spread function as a wave propagating along the optical axis. It provides a comprehensive exhibition of the characteristics for the hybrid imaging system in extending the depth of field from both wave optics and geometrical optics. We use it to analyze several well-known optical designs in extending the depth of field from a new viewpoint. The relationships between this approach and the earlier ambiguity function approach are also briefly investigated. (c) 2006 Optical Society of America.
Resumo:
The digital holographic interferometry is used in the dynamic and static measurements of phase variation induced by domain inversion. For the first time, to the authors' knowledge, they observe the existence of ridge-shape phase distribution adjacent to 180 degrees domain wall in congruent LiNbO3 crystal. During the domain wall motion, the phase variations are not uniform but have obvious relaxations. In the static measurement, the ridge elevation can vary linearly with the uniform electric field. The reasonable assumptions are proposed to explain these effects. (c) 2006 American Institute of Physics.
Resumo:
A new set of pure phase filters for realizing transverse superresolution is presented in this paper. The filters, whose significant features are their ability to tune and their simplicity, consist of one half-wave plate between two quarter-wave plates; the half-wave plate is made of two zones that can rotate with respect to each other. By rotating any zone of the half-wave plate, the central lobe width of the irradiance point spread function (PSF) in the transverse direction can be tunably reduced. At the same time, the axial intensity distribution is analysed in detail.
Resumo:
The correlation between the coma sensitivity of the alternating phase-shifting mask (Alt-PSM) mark and the mark's structure is studied based on the Hopkins theory of partially coherent imaging and positive resist optical lithography (PROLITH) simulation. It is found that an optimized Alt-PSM mark with its phase width being two-thirds its pitch has a higher sensitivity to coma than Alt-PSM marks with the same pitch and the different phase widths. The pitch of the Alt-PSM mark is also optimized by PROLITH simulation, and the structure of p - 1.92 lambda/NA and pw = 2p/3 proves to be with the highest sensitivity. The optimized Alt-PSM mark is used as a measurement mark to retrieve coma aberration from the projection optics in lithographic tools. In comparison with an ordinary Alt-PSM mark with its phase width being a half its pitch, the measurement accuracies of Z(7) and Z(14) apparently increase. (C) 2009 Optical Society of America