81 resultados para multiplexer generator
Resumo:
Single-electron capture in 14 keV q(-1) Ar15+...18++He collisions is investigated both experimentally and theoretically. Partial cross sections and projectile scattering angle dependencies have been deduced from the target ion recoil momenta measured by the COLTRIMS technique. The comparison with close-coupling results obtained from a two-centre extension of the basis generator method yields good overall agreement, demonstrating the applicability of close-coupling calculations to collision systems involving highly charged ions in charge states up to 18+.
Resumo:
According to the method of path integral quantization for the canonical constrained system in Becchi-Rouet-Stora-Tyutin scheme, the supersymmetric electromagnetic interaction system was quantized. Both the Hamiltonian of the supersymmetric electromagnetic interaction system in phase space and the quantization procedure were simplified. The BRST generator was constructed, and the BRST transformations of supersymmetric fields were gotten; the effective action was calculated, and the generating functional for the Green function was achieved; also, the gauge generator was constructed, and the gauge transformation of the system was obtained. Finally, the Ward-Takahashi identities based on the canonical Noether theorem were calculated, and two relations between proper vertices and propagators were obtained.
Resumo:
We give a generalized Lagrangian density of 1 + 1 Dimensional O( 3) nonlinear sigma model with subsidiary constraints, different Lagrange multiplier fields and topological term, find a lost intrinsic constraint condition, convert the subsidiary constraints into inner constraints in the nonlinear sigma model, give the example of not introducing the lost constraint. N = 0, by comparing the example with the case of introducing the lost constraint, we obtain that when not introducing the lost constraint, one has to obtain a lot of various non-intrinsic constraints. We further deduce the gauge generator, give general BRST transformation of the model under the general conditions. It is discovered that there exists a gauge parameter beta originating from the freedom degree of BRST transformation in a general O( 3) nonlinear sigma model, and we gain the general commutation relations of ghost field.
Resumo:
Helicon plasma source is known as efficient generator of uniform and high density plasma. A helicon plasma source was developed for investigation of plasma neutralization and plasma lens in the Institute of Modern Physics in China. In this paper, the characteristics of helicon plasma have been studied by using Langmuir four-probe and a high argon plasma density up to 3.9x10(13) cm(-3) have been achieved with the Nagoya type III antenna at the conditions of the magnetic intensity of 200 G, working gas pressure of 2.8x10(-3) Pa, and rf power of 1200 W with a frequency of 27.12 MHz. In the experiment, the important phenomena have been found: for a given magnetic induction intensity, the plasma density became greater with the increase in rf power and tended to saturation, and the helicon mode appeared at the rf power between 200 and 400 W.
New development of advanced superconducting electron cyclotron resonance ion source SECRAL (invited)
Resumo:
Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e mu A of Xe-129(43+), 22 e mu A of Bi-209(41+), and 1.5 e mu A of Bi-209(50+). To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e mu A of Xe-129(27+) and 152 e mu A of Xe-129(30+), although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and Xe-129(27+), Kr-78(19+), Bi-209(31+), and Ni-58(19+) beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production. Finally the future development of SECRAL will be presented.
Resumo:
A novel poly-l-arginine microcapsule was prepared due to its nutritional function and pharmacological efficacy. A high-voltage electrostatic droplet generator was used to make uniform microcapsules. The results show that the membrane strength and permeating property are both remarkably affected with the changes of sodium alginate concentration. With the sodium alginate concentration increasing, gel beads sizes increase from 233 mum to 350 mum, release ratio is also higher at the same time, but the membrane strength decreases.
Resumo:
A 2-kW-class chemical oxygen-iodine laser (COIL) using nitrogen buffer gas has been developed and tested since industrial applications of COIL devices will require the use of nitrogen as the buffer gas. The laser, with a gain length of 11.7 cm, is energized by a square pipe-array jet-type singlet oxygen generator (SPJSOG) and employs a nozzle bank with a designed Mach number of 2.5. The SPJSOG has advantages over the traditional plate-type JSOG in that it has less requirements on basic hydrogen peroxide (BHP) pump, and more important, it has much better operational stability. The SPJSOG without a cold trap and a gas-liquid separator could provide reliable operations for a total gas flow rate up to 450 mmol/s and with a low liquid driving pressure of around 0.7 atm or even lower. The nozzle bank was specially designed for a COIL using nitrogen as the buffer gas. The cavity was designed for a Mach number of 2.5, in order to provide a gas speed and static temperature in the cavity similar to that for a traditional COIL with helium buffer gas and a Mach 2 nozzle. An output power of 2.6 kW was obtained for a chlorine flow rate of 140 mmol/s, corresponding to a chemical efficiency of 20.4%. When the chlorine flow rate was reduced to 115 mmol/s, a higher chemical efficiency of 22.7% was attained. Measurements showed that the SPJSOG during normal operation could provide a singlet oxygen yield Y greater than or equal to 55%, a chlorine utilization U greater than or equal to 85%, and a relative water vapor concentration w = [H2O]/([O-2] + [Cl-2]) less than or equal to 0.1.
Resumo:
CLIGEN是目前较全面产生降水要素(降水量、历时、达到最大降水强度的时间与降水总历时的比率、最大降水强度与平均降水强度的比率)的天气发生器,其生成降水要素的质量直接影响水文和农业响应模型的输出结果。利用黄土高原长武1957—2001年的日气象观测数据、王东沟流域1988—2001年的降水要素数据和CLIGEN生成的100年日气象数据,对CLIGEN模型产生日、月、年降水量的均值和方差、概率分布、降水极端值和降水历时、强度进行评估。结果表明:CLIGEN对日、月和年降水量均值的模拟效果较好,相对误差都不大于1.0%;对标准差的模拟结果偏低,相对误差的绝对值小于6.6%;没有模拟出日降水量的概率分布,但是较好地模拟出了月和年降水量的概率分布;对日、月和年最大降水量的模拟误差较大,表明CLIGEN对极值的模拟精度有待提高。CLIGEN很好地模拟出连续降水的频率,但是连续干旱天数在20 d以内的累积频率的平均相对误差为8.9%;CLIGEN产生的最大降水强度与平均降水强度的比率高于实测数据;相对于实测数据,CLIGEN模拟的降水历时和降水量具有相同的趋势,对小降水量或短历时的模拟结果偏高,对大降水量或长历时的模拟结...
Resumo:
Rotating minidisk-disk electrode (RMDDE) was developed by replacing ring electrode of rotating ring-disk electrode (RRDE) with a minidisk electrode. Its applications were demonstrated by studying electrochemical reactions of ferricyanide and divalent copper. The replacement of ring electrode by minidisk electrode results in following advantages. First, the fabrication of RMDDE is easier than that of RRDE with the same electrode material. Second, there is more freedom in choosing electrode materials and sizes, since it is difficult to make thin ring electrodes of RRDE with fragile materials. Third, the replacement of ring electrode by minidisk electrode saves electrode materials, especially rare materials. Finally, the substitution of minidisk electrode for ring electrode allows using multiple minidisks for simultaneous monitoring of multiple components. Therefore, RMDDE is a promising generator-collector system, especially when special generator-collector systems are not commercially available, such as corrosion study and electrocatalysis study of new electrode materials.
Resumo:
Cyclic voltammetry of Vitamin K-3 (V-K3) was measured with Pt disk electrode, platinum interdigitated array (Pt-IDA) and Au-IDA microelectrodes in single and dual modes. The effects of pH, scan rate and collector potential on the current of generator and collector were studied. The collection efficiency of V-K3 at IDA electrodes was measured. The linear ranges for current response as a function of V-K3 concentration were found to he 10 mu M-1 mM (i(g)) and 1 mu M - 1 mM (i(c)) for the generator and collector of the Pt-IDA electrode, respectively. The effects of waiting time, potential difference and pulse electrolysis time in differential pulse voltammetry (DPV) on the peak current of V-K3 were studied to get the optimal condition at 0.1 M Na2HPO4, pH 11.50 and 11.0 for Au-IDA and Pt-IDA, respectively.
Resumo:
A reversed-phase high-performance liquid chromatography with series dual glassy carbon electrodes for the amperometric detection of water-soluble menadione is described. The complex post-column derivatization reaction and the high background currents were avoided. The menadione sodium bisulfite was reduced at -0.3 V vs. SCE at the upstream (generator) electrode and oxidized at +0.2V vs. SCE at the downstream (collector) electrode. The mobile phase was 0.2moll(-1) HAc-NaAc aqueous buffer (pH 5.50) and 40% (v/v) methanol. The linear response was in the range of 35 ng to 15 mu g, with a detection Limit of 15 ng (S/N=3). The correlation coefficient was 0.9997 (n=6). The electrochemical detection with series dual electrodes has a higher selectivity for menadione (vitamin K-3) compound than with UV detection.
Resumo:
A simple set of electric circuits was used to assemble a pulse generator. With pulse potentials and under galvanostatical control, a clean silver wire was anodized electrochemically for 0.2-0.5 min in 1.0 moll(-1) HCl with a pulse current density of 20 mA cm(-2), and the pulse wave parameters of t(a)/t(c) = 1 and a cycle of 4 s forming an Ag/AgCl reference electrode. Even though the AgCl layer was consumed during the working period when the Ag/AgCl electrode was used as a cathode, the AgCl layer could be in situ recovered electrochemically in serum used when a reversed potential was applied to the electrode system immediately after the measuring program was finished. The current response curve of the anode indicated that an AgCl layer in high density was basically accomplished during the first 6 pulse cycles in human serum. In order to keep a stable and uniform AgCl layer on the reference electrode after each measuring cycle, the ratio of the recovery time (t(r)) to the working time (t(w)) was measured and the smallest value was obtained at 0.03. The open-circuit potential of the Ag/AgCl electrode with respect to a SCE in 0.1 moll(-1) KCl was monitored over a period of 14 days and the mean value was 40.09 mV vs SCE with a standard deviation of 2.55 mV. The potential of the Ag/AgCl reference electrode did remain constant when the measurements were repeated more than 600 times in undiluted human serum with a standard deviation of 1.89 mV. This study indicated that the Ag/AgCl reference electrode could been rapidly fabricated with a pulse potential and could be used as a reference electrode with long-term stable properties in human serum samples.
Resumo:
An expert system for the elucidation of the structures of organic compounds-ESESOC-II has been designed. It is composed of three parts: spectroscopic data analysis, structure generator, and evaluation of the candidate structures. The heart of ESESOC is the structure generator, as an integral part, which accepts the specific types of information, e.g. molecular formulae, substructure constraints, and produces an exhaustive and irredundant list of candidate structures. The scheme for the structural generation is given, in which the depth-first search strategy is used to fill the bonding adjacency matrix (BAM) and a new method is introduced to remove the duplicates.
Resumo:
An expert system for the elucidation of the structure of organic compounds (ESESOC) has been developed. The heart of the ESESOC is formed by the structure generator as an integral part, which receives the specific type of information (molecular formula, s
Resumo:
具有三维运动能力和独特的节律运动方式,使生物蛇能在复杂的地形环境中生存.大多数动物节律运动是由中央模式发生器(Centralpatterngenerator,CPG)控制的.以此为理论依据,首次以循环抑制建模机理构建蛇形机器人组合关节运动控制的CPG模型.证明该模型是节律输出型CPG中微分方程维数最少的.采用单向激励方式连接该类CPG构建蛇形机器人三维运动神经网络控制体系,给出该CPG网络产生振荡输出的必要条件.应用蛇形机器人动力学模型仿真得到控制三维运动的CPG神经网络参数,利用该CPG网络的输出使“勘查者”成功实现三维运动.该结果为建立未探明的生物蛇神经网络模型提供了一种全新的方法.