Voltammetric study of vitamin K-3 at interdigitated array microelectrodes
Data(s) |
1999
|
---|---|
Resumo |
Cyclic voltammetry of Vitamin K-3 (V-K3) was measured with Pt disk electrode, platinum interdigitated array (Pt-IDA) and Au-IDA microelectrodes in single and dual modes. The effects of pH, scan rate and collector potential on the current of generator and collector were studied. The collection efficiency of V-K3 at IDA electrodes was measured. The linear ranges for current response as a function of V-K3 concentration were found to he 10 mu M-1 mM (i(g)) and 1 mu M - 1 mM (i(c)) for the generator and collector of the Pt-IDA electrode, respectively. The effects of waiting time, potential difference and pulse electrolysis time in differential pulse voltammetry (DPV) on the peak current of V-K3 were studied to get the optimal condition at 0.1 M Na2HPO4, pH 11.50 and 11.0 for Au-IDA and Pt-IDA, respectively. |
Identificador | |
Idioma(s) |
英语 |
Fonte |
Liu ZM;Li J;You TY;Yang XR;Wang EK.Voltammetric study of vitamin K-3 at interdigitated array microelectrodes,ELECTROANALYSIS,1999,11(1):53-58 |
Palavras-Chave | #PERFORMANCE LIQUID-CHROMATOGRAPHY #STEADY-STATE CURRENTS #ELECTROCHEMICAL CHARACTERIZATION #QUANTITATIVE-ANALYSIS #DIGITAL-SIMULATION #ELECTRODES #FABRICATION #ENSEMBLES |
Tipo |
期刊论文 |