100 resultados para Linear range


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The p-toluene sulfonic acid (MA) in phenol matrix was separated and determined by capillary electrophoresis with ultraviolet detector. the effect of the concentration and pH of the buffer on separation was investigated. Cinnamic acid has been chosen as the internal standard from four compounds, the calibration curves of PTSA in 50 mg/L phenol matrix were obtained with and without the internal standard. The linear range was from 1.25 to 12.5 mg/L and the correlation coefficient was 0.9999 for both curves. The limit of detection of PISA was 0.75 mg/L at 3 times of SIN. Finally, the concentration of PTSA in four synthesized samples was determined with method of standard additions, and the effect of matrix was discussed. The values of MA in these samples were 1.01, 0.94, 1.56 and 0.00 mg/L respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel amperometric biosensor for the detection of hydrogen peroxide is described. The biosensor was constructed by electrodepositing HRP/PPy membrane on the surface of ferrocenecarboxylic acid mediated sol-gel derived composite carbon electrode. The biosensor gives response to hydrogen peroxide in a few seconds with detection limit of 5x10(-7) mol (.) L-1 (based on signal : noise=3). Linear range is up to 0.2 mmol (.) L-1.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A peroxidase was extracted from Chinese soybean seed coat, and its thermostability and acid-stability were characterized. This peroxidase was immobilized into a self-gelatinizable grafting copolymer of polyvinyl alcohol with 4-vinylpyridine(PVA-g-PVP) to construct an acid-stable hydrogen peroxide biosensor. The effect of pH was studied for optimum analytical performances by amperometric and spectro-photometric methods, also the K-m(app) and the stability of the soybean peroxidase-based biosensor are discussed. At pH 3.0, the soybean peroxidase maintained its bioactivity and the enzyme electrode had a linear range from 0.01 to 6.2 mM with a detection limit of 1.0 x 10(-7) M. In addition, the main characteristics of different hydrogen peroxide sensors were compared.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We have made a cheap microsystem of capillary electrophoresis with a new method, integrating the electrodes, injection channel, separation channel, buffer reservoirs and detection cell on a polymethylmethacrylate (PMMA) chip. Using an integrated micro carbon fiber disk electrode as the working electrode in three electrodes system, 1 x 10(-4) mol/L dopamine(DA) could be detected with end-column amperometric detection. The reproducibility was good. Peak current was 6.73 nA,theoretical plate number was 71300/m and height equivalent of one theoretical plate height was 14.0 mum for 1 x 10(-4) mol/L DA. The limit of detection was 3.6 x 10(-8) mol/L and the linear range was extended from 5 x 10(-7) mol/L to 1 x 10(-4) mol/L for DA. 1 x 10(-4) mol/L catechol (CA) and 5 x 10(-5) mol/L DA were also separated completely with R-s = 10.1.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An amperometric glucose biosensor was constructed based on a glassy carbon electrode modified with a Cobalt(II)hexacyanoferrate film which catalyzes electroreduction of hydrogen peroxide. Gelatin was used as immobilization matrix. Interference could be effectively eliminated by the combination of low detection potential with a Nafion coating. A low applied potential can avoid oxidation of interferences such as ascorbic acid, uric acid, p-acetyl-aminophenol, etc.. Nafion coating prevents interferences from access to the electrode surface by electrostatic repulsion. A wide linear range of detection was obtained. Analytical performance parameters are given and kinetic analysis discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

End-column amperometric detection of 6-mercaptopurine by capillary zone electrophoresis was described with high resolution and speed. The detection conditions were optimized and the electrochemical behavior was observed. Under the optimal conditions: detection potential of 1.2 V ( vs. Ag/AgCl), operating voltage of 15 kV, sample injection of 3 s at 15 kV and 10 mmol/l Na2HPO4 buffer, the detection limit for 6-MP was as low as 1 x 10(-7) mol/L and the linear range was from 5 x 10(-4) to 5 x 10(-6) mol/L with the relative coefficient of 0.995. The RSD of reproducibility for peak current and migration time was 2.5% and 1.2%, respectively. This method was utilized in assay real sample of human mine and bovine serum albumin containing 6-mercaptopurine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A tyrosinase-based amperometric biosensor using a self-gelatinizable graft copolymer of poly(vinyl alcohol) with 4-vinylpyridine (PVA-g-PVP) as an immobilization matrix was constructed. The 4-vinylpyridine component of PVA-g-PVP enhances the adherence to a glassy carbon electrode surface. The content of 4-vinylpyridine in this immobilization matrix plays a key role in retaining the activity of tyrosinase. A simple, milder method was adopted by simply syringing the copolymer-tyrosinase aqueous solution on to the electrode surface and allowing water to evaporate at 4 degrees C in a refrigerator. Several parameters, including copolymer composition; pH, applied potential and enzyme membrane composition, ware optimized. The enzyme membrane composition can be varied to obtain higher sensitivity or a wider linear detection range. The biosensor was used for the determination of phenol, p-cresol and catechol. The biosensor exhibited excellent reproducibility, stability and sensitive response and can be used in flow injection analysis. The biosensor showed an extended linear range in hydrophilic organic solvents and it can be used in monitoring organic reaction processes. The analytical performance demonstrated this immobilization matrix is suitable for the immobilization of tyrosinase.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fluorescence of terbium(III) was sensitized when excited in the presence of sparfloxacin (SPFX) in the aqueous solution because a Tb(III)-SPFX complex was formed. The sensitized fluorescence was further enhanced when this system was exposed to 365 nm ultraviolet light. By the spectral properties and contrast experiments, it is proved that irradiation makes this system undergo photochemical reactions and a new terbium complex which is more favorable to the intramolecular energy transfer is formed. The mechanism of photochemical fluorescence enhancement of the Tb(III)-SPFX system is discussed and a new sensitive and selective photochemical fluorimetry for the determination of SPFX is established. Under the optimum conditions, the linear range is 1.0-50 x 10(-7) M for SPFX, the detection limit is 3.0 x 10(-9) M and the R.S.D. for 5.0 x 10(-7) M SPFX is 1.3% (n = 9). Without any pretreatment the recovery of SPFX in human urine was determined with satisfaction. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel functionalized inorganic-organic hybrid material with cation exchange property was prepared by sol-gel method. The H2O2 biosensor was fabricated by simply dipping the horseradish peroxidase-containing functionalized membrane modified electrode into Meldola's blue (MDB) solution. MDB was adsorbed and firmly immobilized within the membrane. The electrochemical behavior of MDB incorporated in the membrane was more reversible compared with that of the solution species and suitable as mediator for the horseradish peroxidase. The response time was less than 25 s. Linear range is up to 0.6 mM (COH. coeff. 0.9998) with detection Limit of 9 x 10(-7) M. High sensitivity of 75 nA mu M cm(-2) was obtained due to high MDB-loading. The biosensor exhibited a good stability. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A rapid and sensitive detection method for the determination of 5-fluorouracil(5-FU) in real samples such as human urine and bovine serum albumin (BSA) was described. A carbon fiber microdisk electrode was used to perform end-column amperometric detection in capillary zone electrophoresis. The detection limit was as low as 2.5x10(-7) M and the wider linear range for the concentration was between 5x10(-6) and 1x10(-4) M with a correlation coefficient of 0.995.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Promethazine and thioridazine were separated and detected by capillary electrophoresis with end-column amperometric detection. The influence of pH Value on oxidation potential, the peak current and the resolution were studied and the following conditions was selected: 0.03 M Na2HPO4 and 0.015 M citric acid at pH 3.0, detection potential at 1.10 V. The detection limits of these two substances were in the range of 10(-8) mol/l. The linear range spanned two to three orders of magnitude. This method was applied to the detection of promethazine and thioridazine spiked in urine. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel poly(vinyl alcohol) grafting 4-vinylpyridine self-gelatinizable copolymer was adapted to immobilize glucose oxidase. The reduction of hydrogen peroxide (H2O2) was detected at a Prussian Blue (PB) modified graphite electrode. A stable and sensitive glucose amperometric biosensor is described. The copolymer is a good biocompatible polymer in which the glucose oxidase retains high activity. Moreover, the copolymer can adhere firmly to the inorganic PB membrane. The sensor showed an apparent Michaelis-Menten constant of 18 +/- 0.2 mM and a maximum current density of 1.14 mu A cm(-2) mM(-1). The linear range is from 5 mu M to 4.5 mM glucose and the detection limit is 0.5. mu M glucose. The catalytic efficiency of PB for the reduction of H2O2 is higher than that for the oxidation of H2O2. Glucose concentrations in serum samples from healthy persons and diabetic patients were determined using the sensor. The results compared well with those provided by the hospital using a spectroscopy method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Measurement of iron and manganese is very important in evaluating the quality of natural waters. We have constructed an automated Fe(II), total dissolved iron(TDI), Mn(II), and total dissolved manganese(TDM) analysis system for the quality control of underground drinking water by reverse flow injection analysis and chemiluminescence detection(rFIA-CL), The method is based on the measurement of the metal-catalyzed light emission from luminol oxidation by potassium periodate. The typical signal is a narrow peak, in which the height is proportional to light emitted and hence to the concentration of metal ions. The detection limits were 3 x 10(-6) mu g ml(-1) for Fe(II) and the linear range extents up to 1.0 x 10(-4) and 5 x 10(-6) mu g ml(-1) for Mn(II) cover a linear range to 1.0 x 10(-4) mu g ml(-1). This method was used for automated in-situ monitoring of total dissolved iron and total dissolved in underground water during water treatment. (C) 1997 Elsevier Science B.V.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Monolayers of biological compounds including redox proteins and enzymes, and phospholipids have been immobilized on a gold electrode surface through self-assembling. These proteins and enzymes, such as cytochrome c, cytochrome c oxidase and horseradish peroxidase (HRP), immobilized covalently to the self-assembled monolayers (SAMs) of 3-mercaptopropionic acid on a gold electrode, communicate directly electrons with the electrode surface without mediators and keep their physiological activities. The electron transfer of HRP with the gold electrode can also be mediated by the alkanethiol SAMs with electroactive group viologens on the gold electrode surface. All these direct electrochemistries of proteins and enzymes might offer an opportunity to build a third generation of biosensors without mediators for analytes, such as H2O2, glucose and cholesterol. Monensin and valinomycin have been incorporated into the bilayers on the gold electrode consisting of the SAMs of alkanethiol and a lipid monolayer, which have high selectivity for monovalent ions, and the resulting Na+ or K+ sensor has a wide linear range and high stability. These self-assembly systems provide a good mimetic model for studying the physiological function of a membrane and its associated enzyme. (C) 1997 Elsevier Science S.A.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new immobilization material and an immobilization method for a glucose sensor with HEFc (hydroxyethylferrocene) as mediator is described. In the course of three months, the enzyme electrode shows almost no deterioration in its response characteristics. The response time is less than 30 s. The electrode has a wide linear range up to 10 mmol l(-1) with good repeatability. The kinetic parameters have also been calculated.