86 resultados para Precision Xtra®


Relevância:

10.00% 10.00%

Publicador:

Resumo:

光路自动准直系统应用于惯性约束聚变的高功率激光装置中的光束自动调整。图像处理是光路自动准直的关键技术之一。针对神光Ⅲ原型装置,结合阈值化、重心法、中值滤波和圆拟合等多种不同的图像处理方法设计了一套合理的准直方案,并且在模拟实验平台上进行了实验验证。实验结果表明,光路自动准直系统能够在15min之内顺利完成光路的自动调整,光束近场调整精度优于近场光斑的±0.5%,光束远场调整精度≤±0.3″,满足了原型装置的总体要求。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

压电驱动器的位移输出能力有限,因此通常借助于柔性机构对其位移量进行放大。对常用的柔性放大机构的性能进行了分析。提出一种柔性八杆放大机构,并对其进行有限元分析和理论计算。为了提高放大率,提出两级串连式机构。机构整体具有结构紧凑、放大效率较高的优点。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

提出一种新型的五自由度精密定位平台的工作原理及其设计方法。工作台采用压电陶瓷作为驱动元件,柔性导向机构实现平移及转动功能。整个工作台可由整块金属材料通过线切割加工制成,实现一体化加工,而且结构紧凑。并给出导向机构刚度计算公式及设计实例。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

提出一种新型的五自由度精密定位平台的工作原理及其设计方法。工作台采用柔性导向机构实现平移及转动功能,采用压电陶瓷作为驱动元件,外置纳米级电容传感器作为位移量测量反馈元件,采用数字PID控制方法,可以实现纳米级精度的定位。给出了多种形式柔性导向机构刚度计算公式及设计实例。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In petawatt laser system, the gratings used to compose pulse compressor are very large in size which can be only acquired currently by arraying small aperture gratings to form a large one instead, an approach referred to as grating tiling. Theory and experiments have demonstrated that the coherent addition of multiple small gratings to form a larger grating is viable, the key technology of which is to control the relative position and orientation of each grating with high precision. According to the main factors that affect the performance of the grating tiling, a 5-DOF ultraprecision stage is developed for the grating tiling experiment. The mechanism is formed by serial structures. The motion of the mechanism is guided by flexure hinges and driven by piezoelectric actuators and the movement resolution of which can achieve nanometer level. To keep the stability of the mechanism, capacitive position sensors with nanometer accuracy are fixed on it to provide feedback signals with which to realize closed-loop control, thus the positioning precision of the mechanism is within several nanometers range through voltage control and digital PID algorithm. Results of experiments indicate that the performance of the mechanism can meet the requirement of precision for grating tiling.}

Relevância:

10.00% 10.00%

Publicador:

Resumo:

在干涉检验过程中, 被检元件的面形误差检测精度受到干涉仪系统结构的影响, 从而降低测量结果的可靠性。为了得到较高的检测精度, 必须对检测系统进行分析, 建立测量误差和系统结构的关联度。根据菲涅耳衍射近似理论, 就菲佐干涉仪中的准直镜和标准镜面形误差对透过检测的影响进行了研究。通过对波前相位传递情况的分析, 得出波前误差和系统结构参量的相关性, 去除空腔系统误差, 优化结构参量, 并建立准直镜误差容限表达式。经计算得出, 当被检面形变误差为0.2λ时, 测试误差可以达到0.02λ, 而对准直镜的面形误差要求

Relevância:

10.00% 10.00%

Publicador:

Resumo:

在神光Ⅱ第9路ICF高功率激光装置中,采用可调法布里-珀罗(F-P)滤波器对幅度调制效应进行补偿,根据补偿装置的技术要求,提出-种应用nm量级精度的电容式位移传感器对可调F-P滤波器间距稳定度进行监控的系统,详细论述了监控系统的结构与工作原理。给出了电容式位移传感器的驱动电路及数据处理与控制软件的设计方案,并对电容式位移传感器的精度进行了标定。实验结果表明,该位移监控系统能够使可调F—P滤波器的间距稳定度保持在15nm/h以内,使幅度调制效应的调制深度优于4%。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

研制了一种高精度电容式位移传感器,详细介绍了该传感器的基本工作原理和提高传感器精度的关键技术,对电容传感器的具体电路进行模块化设计;分析影响传感器精度与稳定性的因素,采用完全等电位屏蔽技术,对正弦激励电路、参考电容、传感器测头、电源进行技术改进,最后对电容传感器进行系统标定。实验证明:该传感器测量范围为±5-±40μm,测量分辨率〈10nm,测量精度〈20nm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

利用二维光谱色散平滑技术和透镜列阵(LA)来改善激光驱动器中靶面的辐照均匀性。通过消衍射透镜列阵可得到包络陡峭且中小空间尺度均匀性较好的焦斑。当在光路中加入二维光谱色散平滑单元后,光束在两个互相垂直的方向发生光谱色散,多光束干涉所引起的细密条纹也将在很大程度上被抹平,如果把横向热传导平滑效应也考虑在内,高空间频率的强度波动可进一步被消除。二维理论模拟结果表明采用该方案可获得顶部平坦边缘陡峭的焦斑,而且该方案无需仔细调整靶面的位置,实际应用较方便。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

蓝光光存储是信息存储领域发展的一个重要方向。测试系统是研究蓝光光存储材料的必备条件,为建立蓝光光存储研究平台,设计和搭建了一套模块化蓝光光存储性能静态测试系统。激光工作波长为406.7nm。系统采用调制解调技术降低系统噪声,提高测量粘度:采用光点移动模式降低对样品尺寸的要求;采用纳米平台提高记录点的反复定位性能。实验结果证明测试系统性能良好,可以满足蓝光光存储性能静态测试要求。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Blue ray optical storage is one of the important trends in the area of information storage, and attracts a number of researchers. Static tester for blue ray optical storage plays an important role in storage media research. We designed and constructed a static tester, in which modularization makes it very convenient to expand function. Employment of modulation/demodulation technique weakens test error so as to increase test precision. Focus move mode and the nano-positioners facilitate the relocation of recording marks. Only one laser with wavelength 406.7 nm is used. In this paper, system design and characteristics are represented in detail, and some experimental results are also given to show that the static tester can perform successfully, acting as research platform for blue ray optical storage. (c) 2005 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

报道了一种基于光时域反射计的全分布式光纤漏油传感器,该传感器能实现分布式实时监测长输油管道,及时发现小型的漏油事件.传感器沿管道铺设,利用光时域反射计实时测量光纤在长度上的损耗变化特点,及时发现并定位管道上的每一处泄漏事件.模拟实验证明了其实际操作的可行性,长期使用的稳定性和各种抗干扰性,能在15min内发现并定位漏油事件,且定位准确度为3m.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

以E. Sano的金属-半导体-金属光电探测器(MSM-PD)模型为基础,提出了一种改进型的模型。该模型以多个电流源和电容并联的形式构造,以吸收区过剩电子和空穴总数为研究对象,求解速率方程。另外计算了电容,给出了暗电流与端电压的非线性计算式,改进了传统模型中暗电流的线性计算方法。通过线性叠加给出了该模型光电流的数学解析解。通过在Matlab中的模拟计算,表明该模型具有计算量小、准确度高的特点,它不仅能反映一定偏压和光照下光电流的变化,而且能展示光电子在器件中的转化过程。这种模型也能较好地应用于微弱信号的检

Relevância:

10.00% 10.00%

Publicador:

Resumo:

设计了一种深空非合作目标的激光扫描、捕获、跟踪地面实验装置,通过模拟深空同轨道运动的两颗卫星跟瞄过程,在理论上计算了跟瞄装置中光束指向驱动电机的最小加速度和其在跟踪过程中的运动特性。理论分析与仿真结果表明,当卫星偏离光斑中心一定距离时,指向驱动电机先加速后减速,补偿这个偏心,重新捕获跟踪卫星;重新捕获到跟踪所需时间受电机加速度和望远镜探测精度以及探测器响应处理时间影响,其中探测器精度对重新捕获到跟踪所需时间影响较大,探测器响应处理时间要减小到最小;为了使从捕获到跟踪过程中卫星始终在扫描光斑范围内,经纬仪驱动电机的最小角加速度为25.5°/s2。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Up-converting phosphor technology (UPT)-based lateral-flow immunoassay has been developed for quantitative detection of Yersinia pestis rapidly and specifically. In this assay, 400 nm up-converting phosphor particles were used as the reporter. A sandwich immumoassay was employed by using a polyclonal antibody against F1 antigen of Y. pestis immobilized on the nitrocellulose membrane and the same antibody conjugated to the UPT particles. The signal detection of the strips was performed by the UPT-based biosensor that could provide a 980 nm IR laser to excite the phosphor particles, then collect the visible luminescence emitted by the UPT particles and finally convert it to the voltage as a signal. V-T and V-c stand for the multiplied voltage units for the test and the control line, respectively, and the ratio V-T/V-C is directly proportional to the number of Y pestis in a sample. We observed a good linearity between the ratio and log CFU/ml of Y pestis above the detection limit, which was approximately 10(4) CFU/mI. The precision of the intra- and inter-assay was below 15% (coefficient of variation, CV). Cross-reactivity with related Gram-negative enteric bacteria was not found. The UPT-LF immunoassay system presented here takes less than 30 min to perform from the sample treatment to the data analysis. The current paper includes only preliminary data concerning the biomedical aspects of the assay, but is more concentrated on the technical details of establishing a rapid manual assay using a state-of-the-art label chemistry. (c) 2006 Elsevier B.V. All rights reserved.