574 resultados para negotiation with Chinese


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A recoil separator Wien-filter which was developed for the Radioactive Ion Beam Line in Lanzhou (RIBLL) as an extension is described. It consists of 2 quadruple triplets and a standard Wien-filter. It was designed for study of the fusion-evaporation reactions. The overall design, background suppression, the transmission efficiency, the angular acceptance and the momentum acceptance have been described. All the performances fulfil the designed requirements. Based on the test results, with some modifications the investigations of the nuclei with Z <= 110 and the drip-line nuclei in the medium-heavy mass region can be carried out with this facility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The neutron-rich target-like isotope Th-236 was produced in U-238-2p multinucleon transfer reaction between a 60MeV/u O-18 beam and nature U-238 targets. The thorium activities were radiochemically separated from the mixture of uranium and reaction products. The isotope Th-236 was identified by 642.2keV, 687.6keV and 229.6keV characteristic gamma-rays. The production cross section of Th-236 has been determined to be 250 +/- 50 mu b.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The multi-electron processes are investigated for 17.9-120keV/u C1+, 30-323 keV/u C2+, 120-438 keV/u C3+, 287-480keV/u C4+ incident on a helium target. The cross-section ratios of double electron (DE) process to the total of the single electron (SE) and the double electron process (i.e. SE+DE), the direct double electron (DDI) to the direct single ionization (DSI) as well as the contributions of DDI to DE and of TI to DE are measured using coincidence techniques. The energy and charge state dependences of the measured cross-section ratios are studied and discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the construction of the neutron detection wall at the external target position on Heavy Ion Research Facility in Lanzhou-Cooling Storage Ring (HIRFL-CSR), it will be possible to detect high energy neutron. A BUU model is applied to simulate the flow in both symmetric (Ni+Ni, Pb+Pb) and asymmetric(Pb+Ni) systems. It is shown that at above several hundreds MeV/u, the flow signals are very obvious and depend clearly on the centrality of the collisions. Based on the products in the forward angle less than 20 degrees, the simulation also reveals that the determination of the reaction plane and the selection of the impact parameter, both of which are essential in the flow measurement, are well implemented. The double event and its influence on the determination of the neutron flow are also simulated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within the framework of the pilot heavy-ion therapy facility at GSI equipped with an active beam delivery system of advanced raster scanning technique, a feasibility study on actively conformal heavy-ion irradiation to moving tumors has been experimentally conducted. Laterally, real-time corrections to the beam scanning parameters by the raster scanner, leading to an active beam tracing, compensate for the lateral motion of a target volume. Longitudinally, a mechanically driven wedge energy degrader (called depth scanner) is applied to adjust the beam energy so as to locate the high-dose Bragg peak of heavy ion beam to the slice under treatment for the moving target volume. It has been experimentally shown that compensations for lateral target motion by the raster scanner and longitudinal target shift by the depth scanner are feasible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The cross-section ratios of double-, triple-, quadruple-, and the total multi-electron processes to the single electron capture process sigma(DE)/sigma(SC), sigma(TE)/sigma(SC), sigma(QE)/sigma(SC) and sigma(ME)/sigma(SC)) as well as the relative ratios among reaction channels in double-electron active, triple-electron active and quadruple- electron active are measured in C-13(6+) -Ne collision in the energy region of 4.15-11.08 keV/u by employing position-sensitive and time-of-flight coincident techniques. It is determined that the cross-section ratios sigma(DE)/sigma(SC), sigma(TE)/sigma(SC), sigma(QE)/sigma(SC) and sigma(ME)/sigma(SC) are approximately the constants of 0.20 +/- 0.03, 0.16 +/- 0.04, 0.06 +/- 0.02 and 0.42 +/- 0.05. These values are obviously smaller than the predictions of the molecular Coulomb over-the-barrier model (MCBM) [J. Phys. B 23 (1990) 4293], the extended classical over-the-barrier model (ECBM) [J. Phys. B 19 (1986) 2925] and the semiempirical scaling laws (SL) [Phys. Rev. A 54 (1996) 4127]. However, the relative ratios among partial processes of DE, TE and QE are found to depend on collision energy, which suggests that the collision dynamics depends on the collision velocity. The limitation of velocity-independent character of ECBM, MCBM and SL is undoubtedly shown.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, to design a new preamplifier for optimum performances with charged-particle or heavy-ion detectors, the CMOS FET is implemented as a feedback capacitor C-fp, so that the entire system should be built only with MOSFET. This work is a revolution design because to realize an ASIC for a preamplifier circuit, the capacitor will also be included. We succeed after a simulation to maintain a rise time less than 3 ns, the output resistance less than 94 Omega and the linearity almost good.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A prototype of time-of-flight positron emission computed tomography (TOF-PET) has been developed for acquiring the coincident detection of 511 keV gamma-rays produced from positron annihilation. It consists of two 80.5 mmx80.5 mm LYSO scintillator arrays (composed of 35 x35 pixel finger crystals) with the position sensitive photomultiplier tubes R2487 as the readout. Each array is composed of 2 mm x2 mm x 15 mm finger crystals and the average pixel pitch is 2.30 mm. The measured results indicate that the TOF information has the potential to significantly enhance the image quality by improving the noise variance in the image reconstruction. The best spatial resolution (FWHM) of the prototype for the pairs of 511 keV gamma-rays is 1.98 mm and 2.16 mm in the x and y directions, respectively, which are smaller than the average pixel pitch of 2.30 mm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel Micro-pattern gaseous detector (MPGD), thick GEM with electrodes made of a resistive material (RETGEM) is presented. In this paper we mainly investigate the energy resolution of a RETGEM in Ar+CO2 with different gas mixtures. The results indicate that an energy resolution 30% in single and double mode can be obtained. The existence of an optimum energy resolution is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Influence of core property on multi-electron process in the collisions of q = 6-9 and 11 isocharged sequence ions with Ne is investigated in the keV/u region The cross-section ratios of double-, triple-, quadruple- and total multi-electron processes to the single electron capture process as well as the partial ratios of different reaction channels to the relevant multi-electron process are measured by using position-sensitive and time-of-flight techniques The experimental data are compared with the theoretical predictions including the extended classical over-barrier model, the molecular Columbic barrier model and the semi-empirical scaling law Results show a core effect on multi-electron process of isocharge ions colliding with Neon, which is consistent with the results of Helium we obtained previously

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The bioactivity screening of fractions from two inter-tidal sponges collected from the north of China Yellow Sea and one sponge collected from the South Chinese Sea was reported in this study. In sponge Hymeniacidon perleve there were 9 fractions out of 15 from CHCl3 extract with anti Staphylococcus aureus activity, 9 fractions out of 19 from BuOH extract with anti Escherichia coli activity, and three fractions from CHCl3 extract which had moderate to strong activity in inhibiting Bacillus subtilis, Candida albicans, and Aspergilus niger. The fractions of Reniochalina sp. showed bioactivity against bacteria and fungi. The fractions of Acanthella acuta Schmidt showed bioactivity against S. aureus and fungi. One compound from H. perleve obtained by the bioactively directing isolation was tested for bioactivity against the human hepatoma cell line Qgy7701 (IC50 10.1 mug/ml), Burkitt's lymphoma cell line Raji (IC50 9.76 mug/ml) and chronic myelogenous leukemia K562 (IC50 1.90 mug/ml). (C) 2003 Elsevier B.V. All rights reserved.