79 resultados para Total intravenous anesthesia
Resumo:
This paper presents the total dose radiation performance of 0. S^m SOI CMOS devices fabricated with full dose SIMOX technology. The radiation performance is characterized by threshold voltage shifts and leakage currents of transistors and standby currents of ASIC as functions of the total dose up to 500krad(Si) .The experimental results show that the worst case threshold voltage shifts of front channels are less than 320mV for pMOS transistors under off-gate radiation bias at lMrad(Si) and less than 120mV for nMOS transistors under on-gate radiation bias. No significant radiation-induced leakage current is observed in transistors to lMrad(Si). The standby currents of ASIC are less than the specification of 5μA over the total dose range of 500krad(Si).
Resumo:
In order to improve the total-dose radiation hardness of the buried oxides(BOX) in the structure of separa tion-by-implanted-oxygen(SIMOX) silicon-on-insulator(SOI), nitrogen ions are implanted into the buried oxides with two different doses,2 × 1015 and 3 × 1015 cm-2 , respectively. The experimental results show that the radiation hardness of the buried oxides is very sensitive to the doses of nitrogen implantation for a lower dose of irradiation with a Co-60 source. Despite the small difference between the doses of nitrogen implantation, the nitrogen-implanted 2 × 1015 cm-2 BOX has a much higher hardness than the control sample (i. e. the buried oxide without receiving nitrogen implantation) for a total-dose irradiation of 5 × 104rad(Si), whereas the nitrogen-implanted 3 × 1015 cm-2 BOX has a lower hardness than the control sample. However,this sensitivity of radiation hardness to the doses of nitrogen implantation reduces with the increasing total-dose of irradiation (from 5 × 104 to 5 × 105 rad (Si)). The radiation hardness of BOX is characterized by MOS high-frequency (HF) capacitance-voltage (C-V) technique after the top silicon layers are removed. In addition, the abnormal HF C-V curve of the metal-silicon-BOX-silicon(MSOS) structure is observed and explained.
Spatial Estimation of Soil Total Nitrogen Using Cokriging with Predicted Soil Organic Matter Content
Resumo:
A scheme based on a W-shaped axicon mirror device for total-internal-reflection fluorescence microscopy (TIRFM) is presented. This approach combines the advantages of higher efficiency compared with traditional TIRFM, adjustable illumination area, and simple switching between wide-field and TIRF imaging modes. TIRF images obtained with this approach are free of shadow artifacts and of interference fringes. Example micrographs of fluorescently labeled polystyrene beads, of Convallaria majalis tissue, and of Propidium-iodide-labeled Chinese hamster ovary cells are shown, and the capabilities of the scheme are discussed. (C) 2010 Optical Society of America