Sensitivity of Total-Dose Radiation Hardness of SIMOX Buried Oxides to Doses of Nitrogen Implantation into Buried Oxides
Data(s) |
2005
|
---|---|
Resumo |
In order to improve the total-dose radiation hardness of the buried oxides(BOX) in the structure of separa tion-by-implanted-oxygen(SIMOX) silicon-on-insulator(SOI), nitrogen ions are implanted into the buried oxides with two different doses,2 × 1015 and 3 × 1015 cm-2 , respectively. The experimental results show that the radiation hardness of the buried oxides is very sensitive to the doses of nitrogen implantation for a lower dose of irradiation with a Co-60 source. Despite the small difference between the doses of nitrogen implantation, the nitrogen-implanted 2 × 1015 cm-2 BOX has a much higher hardness than the control sample (i. e. the buried oxide without receiving nitrogen implantation) for a total-dose irradiation of 5 × 104rad(Si), whereas the nitrogen-implanted 3 × 1015 cm-2 BOX has a lower hardness than the control sample. However,this sensitivity of radiation hardness to the doses of nitrogen implantation reduces with the increasing total-dose of irradiation (from 5 × 104 to 5 × 105 rad (Si)). The radiation hardness of BOX is characterized by MOS high-frequency (HF) capacitance-voltage (C-V) technique after the top silicon layers are removed. In addition, the abnormal HF C-V curve of the metal-silicon-BOX-silicon(MSOS) structure is observed and explained. In order to improve the total-dose radiation hardness of the buried oxides(BOX) in the structure of separa tion-by-implanted-oxygen(SIMOX) silicon-on-insulator(SOI), nitrogen ions are implanted into the buried oxides with two different doses,2 × 1015 and 3 × 1015 cm-2 , respectively. The experimental results show that the radiation hardness of the buried oxides is very sensitive to the doses of nitrogen implantation for a lower dose of irradiation with a Co-60 source. Despite the small difference between the doses of nitrogen implantation, the nitrogen-implanted 2 × 1015 cm-2 BOX has a much higher hardness than the control sample (i. e. the buried oxide without receiving nitrogen implantation) for a total-dose irradiation of 5 × 104rad(Si), whereas the nitrogen-implanted 3 × 1015 cm-2 BOX has a lower hardness than the control sample. However,this sensitivity of radiation hardness to the doses of nitrogen implantation reduces with the increasing total-dose of irradiation (from 5 × 104 to 5 × 105 rad (Si)). The radiation hardness of BOX is characterized by MOS high-frequency (HF) capacitance-voltage (C-V) technique after the top silicon layers are removed. In addition, the abnormal HF C-V curve of the metal-silicon-BOX-silicon(MSOS) structure is observed and explained. 于2010-11-23批量导入 zhangdi于2010-11-23 13:04:37导入数据到SEMI-IR的IR Made available in DSpace on 2010-11-23T05:04:38Z (GMT). No. of bitstreams: 1 4491.pdf: 459152 bytes, checksum: 1f70fe1f8ebb53d8f808e4e046652db4 (MD5) Previous issue date: 2005 Microelectronics R&D Center, Institute of Semiconductors, Chinese Academy of Sciences;Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences |
Identificador | |
Idioma(s) |
英语 |
Fonte |
Zheng Zhongshan;Liu Zhongli;Zhang Guoqiang;Li Ning;Li Guohua;Ma Hongzhi;Zhang Enxia;Zhang Zhengxuan;Wang Xi.Sensitivity of Total-Dose Radiation Hardness of SIMOX Buried Oxides to Doses of Nitrogen Implantation into Buried Oxides,半导体学报,2005,26(5):862-866 |
Palavras-Chave | #微电子学 |
Tipo |
期刊论文 |