55 resultados para Five-Port


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three known standards, including at least one transmission standard, are normally required for the full two-port calibration of test fixtures. Based on the triple-through method, a new general-purpose calibration procedure using only one known reflection standard is proposed in this paper. The experimental results show that our method call provide a simple and accurate approach to fall two-port calibration of the asymmetric test fixtures. (c) 2005 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method to measure reciprocal four-port structures, using a 16-term error model, is presented. The measurement is based on 5 two-port calibration standards connected to two of the ports, while the network analyzer is connected to the two remaining ports. Least-squares-fit data reduction techniques are used to lower error sensitivity. The effect of connectors is deembedded using closed-form equations. (C) 2007 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formulation of a 16-term error model, based on the four-port ABCD-matrix and voltage and current variables, is outlined. Matrices A, B, C, and D are each 2 x 2 submatrices of the complete 4 x 4 error matrix. The corresponding equations are linear in terms of the error parameters, which simplifies the calibration process. The parallelism with the network analyzer calibration procedures and the requirement of five two-port calibration measurements are stressed. Principles for robust choice of equations are presented. While the formulation is suitable for any network analyzer measurement, it is expected to be a useful alternative for the nonlinear y-parameter approach used in intrinsic semiconductor electrical and noise parameter measurements and parasitics' deembedding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The open-short-load (OSL) method is very simple and widely used for one-port test fixture calibration. In this paper, this method is extended, for the first time, to the two-port calibration of test fixtures with different test ports. The problem of phase uncertainty arising in this application has been solved. The comparison between our results and those obtained with the SOLT method shows that the method established is accurate for practical applications. (C) 2002 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the four-wave mixing (FWM) in an opening five-level system with two dressing fields. There are three kinds of doubly dressing mechanisms (parallel cascade, sequential cascade, and nested cascade) in the system for doubly dressed four-wave mixing. These mechanisms reflect different correlations between two dressing fields and different effects of two dressing fields to the FWM. Investigation of these mechanisms is helpful to understand the generated high-order nonlinear optical signal dressed by multi-fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The open-short-load (OSL) method is very simple and widely used, for one-port test fixture calibration. In this paper, this method. is extended to the two-port calibration of test fixtures for the first time. The problem of phase uncertainty arising in this application has been solved. The comparison between our results and those obtained with the short-open-load-thru (SOLT) method shows that the method established is accurate enough for practical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within an extended chiral constituent quark model, the three- and five-quark structure of the S-01 resonance Lambda(1405) is investigated. Helicity amplitudes for electromagnetic decays [Lambda(1405)->Lambda(1116)gamma, Sigma(1194)gamma] and transition amplitudes for strong decays [Lambda(1405)->Sigma(1194)pi, K- p] are derived, as well as the relevant decay widths. The experimental value for the strong decay width, Gamma(Lambda(1405)->(Sigma pi)degrees) = 50 +/- 2MeV, is well reproduced with about 50% of a five-quark admixture in the Lambda(1405). Important effects owing to the configuration mixing among Lambda P-2(1)A, Lambda P-2(8)M, and Lambda P-4(8)M are found. In addition, transitions between the three- and the five-quark components in the baryons turn out to be significant in both radiative and strong decays of the Lambda(1405) resonance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate temporal changes of water quality, a role of dinoflagellate cysts preserved in surface sediments was examined in Yokohama Port in Tokyo Bay, Japan. Two cores were collected, and sedimentation rates and ages of both were dated as approximately 1900 years or slightly older on the basis of 210Pb and 137Cs concentrations. The temporal change in dinoflagellate cyst assemblages in the two cores reflects eutrophication in Yokohama Port in the 1960s. Abrupt increases in the cysts of Gyrodinium instriatum cysts strongly suggests that a red tide was caused by this species around 1985. Dinoflagellate cyst assemblages in surface sediments appear to be good biomarkers of changes in the water quality of enclosed seas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Five new compounds of sulfonylcalix[4]arenetetrasulfonate (SC4AS), [H7Na(H2O)(3)(SC4AS)(phen)(5)](H2O)(11.9) (1), [H6Mn(H2O)(4)(SC4AS)(phen)(5)] (H2O)(12.7) (2), [Cu-4(SC4AS) (phen)(6)] (H2O)(4.5) (3), {[Cu (2)(SC4AS) (bpy)(2)][Cu(bpy)(2)(H2O)](2)} (H2O)(6.6) (4), and {[Zn-2(SC4AS) (phen)(2)][Zn(phen)(2)(H2O)(2)](2)} (H2O)(7) (5) (where phen 1,10-phenanthroline and bpy = 2,2'-bipyridine), were synthesized by a hydrothermal method and structurally determined by single crystal X-ray diffraction. The SC4AS ligand adopts partial cone conformation in compounds 1 and 2 and 1,2-alternate form in compounds 3-5. According to the structural analysis and density functional theory (DFT) calculations, we suggest that the metal can affect the conformation of SC4AS.