128 resultados para Drop Test Equipment.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Accelerating Moment Release (AMR) preceding earthquakes with magnitude above 5 in Australia that occurred during the last 20 years was analyzed to test the Critical Point Hypothesis. Twelve earthquakes in the catalog were chosen based on a criterion for the number of nearby events. Results show that seven sequences with numerous events recorded leading up to the main earthquake exhibited accelerating moment release. Two occurred near in time and space to other earthquakes preceded by AM R. The remaining three sequences had very few events in the catalog so the lack of AMR detected in the analysis may be related to catalog incompleteness. Spatio-temporal scanning of AMR parameters shows that 80% of the areas in which AMR occurred experienced large events. In areas of similar background seismicity with no large events, 10 out of 12 cases exhibit no AMR, and two others are false alarms where AMR was observed but no large event followed. The relationship between AMR and Load-Unload Response Ratio (LURR) was studied. Both methods predict similar critical region sizes, however, the critical point time using AMR is slightly earlier than the time of the critical point LURR anomaly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of the free-stream thermo-chemical state on the test model flow field in the high-enthalpy tunnel are studied numerically. The properties of the free-stream, which is in thermo-chemical non-equilibrium, are determined by calculating the nozzle flow field. A free-stream with total enthalpy equal to the real one in the tunnel while in thermo-chemical equilibrium is constructed artificially to simulate the natural atmosphere condition. The flow fields over the test models (blunt cone and Apollo command capsule model) under both the non-equilibrium and the virtual equilibrium free-stream conditions are calculated. By comparing the properties including pressure, temperature, species concentration and radiation distributions of these two types of flow fields, the effects of the non-equilibrium state of the free-stream in the high-enthalpy shock tunnel are analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present in this paper the results obtained from a parabolic flight campaign regarding the contact angle and the drop interface behavior of sessile drops created under terrestrial gravity (1g) or in microgravity (mu g). This is a preliminary study before further investigations on sessile drops evaporation under microgravity. In this study, drops are created by the mean of a syringe pump by injection through the substrate. The created drops are recorded using a video camera to extract the drops contact angles. Three fluids have been used in this study : de-ionized water, HFE-7100 and FC-72 and two heating surfaces: aluminum and PTFE. The results obtained evidence the feasibility of sessile drop creation in microgravity even for low surface tension liquids (below 15 mN m (-aEuro parts per thousand 1)) such as FC-72 and HFE-7100. We also evidence the contact angle behavior depending of the drop diameter and the gravity level. A second objective of this study is to analyze the drop interface shape in microgravity. The goal of the these experiments is to obtain reference data on the sessile drop behavior in microgravity for future experiments to be performed in an French-Chinese scientific instrument (IMPACHT).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A planar lightwave circuit (PLC) add-drop filter is proposed and analyzed, which consists of a symmetric Mach-Zehnder interferometer (MZI) combined with double microring resonators. A critical coupling condition is derived for a better box-like drop spectrum. Comparisons of its characteristics with other schemes, such as a MZI with a single ring resonator, arepresented, and some of the issues about device design and fabrication are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present paper, we propose a novel method for measuring the even aberrations of lithographic projection optics by use of optimized phase-shifting marks on the test mask. The line/space ratio of the phase-shifting marks is optimized to obtain the maximum sensitivities of Zernike coefficients corresponding to even aberrations. Spherical aberration and astigmatism can be calculated from the focus shifts of phase-shifting gratings oriented at 0 degrees, 45 degrees, 90 degrees and 135 degrees at multiple illumination settings. The PROLITH simulation results show that, the measurement accuracy of spherical aberration and astigmatism obviously increase, after the optimization of the measurement mark. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The encircled energy of a focusing lens is one of the parameters directly affecting the target efficiency in high-power laser facilities. The direct measurement method of the encircled energy for the focusing lens based on the scanning Hartmann test is proposed in this paper. With the scanning Hartmann test setup, the information in the whole aperture of the focusing lens can be achieved. The encircled energy can be obtained by analyzing the spot diagram on the focal plane of the focusing lens. In experiments, the encircled energy of an aspheric focusing lens is measured using this method. The measurement result is in good agreement with that derived from measurement data by an interferometer and the difference is 7.7%. (C) 2006 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to establish a sensitive in vitro assay to assess the binding capacity of cat spermatozoa. Cat oocytes and epididymal sperm cells were isolated from gonads and cultured for in vitro fertilization. Before fertilization, the sperm ce

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Circulatory responses of crucian carp injected intraperitoneally with extracted micro-cystins (MCs) were studied at sublethal and lethal doses (150 and 600 mu g MC kg(-1) body mass, respectively). Mean arterial blood pressure (MAP), heart rate, hematocrit (Hct), red blood cell (RBC) counts, and circulating blood volume (BV) were assayed at 0, 1, 3, 12, 24, and 48 h post-toxin administration. MAP decreased significantly in a dose-dependent manner over time. Within the 48-h test period, the lethal dose as well as the sublethal dose resulted in a steady decline of MAP without recovery. Heart rate significantly increased within 24 h post-injection as blood pressure significantly dropped, then showed a terminal decline to the control level. The dose-dependent decreases in BV and Hct were directly related to the drop in MAP. Intraperitoneal injection of a lethal dose of MCs led to hepatic and gill hemorrhage. Consequently, crucian carp given MCs suffered from hypovolemic hypotensive shock. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perfluorooctane sulfonate (PFOS) is widely distributed and persistent in the environment and wildlife. The main aim of this study was to investigate the impact of long-term exposure to low concentrations of PFOS in zebrafish. Zebrafish fry (F-0, 14d post-fertilization, dpf) were exposed via the water for 70d to 0 (control), 10, 50 and 250 mu g L-1 PFOS, followed by a further 30d to assess recovery in clean water. The effects on survival and growth parameters and liver histopathology were assessed. Although growth suppression (weight and length) was observed in fish treated with high concentrations PFOS during the exposure period, no mortality was observed throughout the 70d experiment. Embryos and larvae (F-1) derived from maternal exposure suffered malformation and mortality. Exposure to 50 and 250 mu g L-1 PFOS could inhibit the growth of the gonads (GSI) in the female zebrafish. Histopathological alterations, primary with lipid droplets accumulation, were most prominently seen in the liver of males and the changes were not reversible, even after the fish were allowed to recover for 30d in clean water. The triiodothyronine (T-3)) levels were not significantly changed in any of the exposure groups. Hepatic vitellogenin (VTG) gene expression was significantly up-regulated in both male and female zebrafish, but the sex ratio was not altered. The overall results suggested that lower concentrations of PFOS in maternal exposure could result in offspring deformation and mortality. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the occupational exposure levels to polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polybrominated diphenyl ethers (PBDEs), and polychlorinated biphenyls (PCBs), indoor dust (n = 3) in workshops and hair samples from male workers (n = 64) were collected at two electrical and electronic equipment waste (E-waste) dismantling factories located in the LQ area in east China in July 11-13, 2006. Pre- and postworkshift urines (64 of each) were also collected from the workers to study oxidative damage to DNA using 8-hydroxy-2'-deoxyguanosine (8-OHdG) as a biomarker. The concentrations of PCDD/Fs, PCDD/F-WHO-TEQs, PBDEs, PCBs and PCB-WHO-TEQs were (50.0 +/- 8.1) x 10(3), 724.1 +/- 249.6, (27.5 +/- 5.8) x 10(6), (1.6 +/- 0.4) x 10(9), (26.2 +/- 3.0) x 10(3) pg/g dry weight (dw) in dust, and (2.6 +/- 0.6) x 10(3), 42.4 +/- 9.3, (870.8 +/- 205.4) x 10(3), (1.6 +/- 0.2) x 10(6), 41.5 +/- 5.5 pg/g dw in hair, respectively. The homologue and congener profiles in the samples demonstrated that high concentrations of PCDD/Fs, PBDEs, and PCBs were originated from open burning of E-waste. The 8-OHdG levels were detected at 6.40 +/- 1.64 mu mol/mol creatinine in preworkshift urines. However, the levels significantly increased to 24.55 +/- 5.96 mu mol/mol creatinine in postworkshift urines (p < 0.05). Then, it is concluded that there is a high cancer risk originated from oxidative stress indicated by the elevated 8-OHdG levels in the E-waste dismantling workers exposed to high concentrations of PCDD/Fs, PBDEs, and PCBs.