82 resultados para Filtering techniques


Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the parameter requirements of a graded reflectivity mirror with a Gaussian profile, the layer structure and the mask pattern are designed using a graded-thickness middle layer. The mask and the automatic mask-switchover equipment are designed considering the actual requirement of the thin films and the specific deposit facility. The uniformity of the layer thickness is analyzed. The measurement results indicate that samples prepared with this technique are basically in accordance with the design parameter. The scattering effect between the material molecules and the mask, thickness errors, and the alignment error between the mask and the substrate are the main factors that influence the deposit result. (c) 2008 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3027595]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bighead carp is one of the most important freshwater filter-feeding fish of Chinese aquaculture. In recent decades, there have been a number of contradictory conclusions on the digestibility of algae by bighead carp based on the results from gut contents and digestive enzyme analysis or radiolabelled isotope techniques. Phytoplankton in the gut contents of bighead carp (cultured in a large net cage in Lake Donghu) were studied during March-May. In biomass, the dominant phytoplankters in the fore-gut contents were the centric diatom Cyclotella (average 54.5%, range 33.8-74.3%) and the dinoflagellate Cryptomonas (average 22.8%, range 6.8-55.8%). Phytoplankton in water samples were generally present in proportionate amounts in samples from the fore-guts of bighead carp. The size of most phytoplankton present in the intestine of bighead carp was between 8 and 20 mum in length. Bighead carp was also able to collect particles (as small as 5-6 mum) much smaller than their filtering net meshes, suggesting the importance of mucus in collecting small particles, Examination of the change in the integrity of Cyclotella on passage through the esophagus of bighead carp indicated that disruption of the algal cell walls is principally by the pharyngeal teeth, explaining the previous contradictory conclusions. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RAPD was used fur analysing three (sub-)species of mitten crabs (Eriocheir sinensis, E. japonicus, and E. japonicus hepuensis) and three populations of E. sinensis. The results show that their relationships on DNA level are similar to the classical taxonomic hypotheses (Dai, 1991). No diagnostic RAPD marker could be found, but there were statistically significant genetic differences among these taxa (P < 0.001) or populations (P < 0.001). That is, the intraspecific similarities were larger than the interspecific similarities; the intrasubspecific similarities were larger than the intraspecific similarities; and the intrapopulational similarities were larger than the interpopulational similarities. In AFLP analysis, no significant genetic difference has been found between E. sinensis and E. japonicus, but AFLP markers among four species of Macrobrachium (M. rosenbergii. M. nipponense, M. hainanense, and M. asperulum) were found. The DNA similarities among these four species of Macrobrachium are in accordance with morphological similarities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The digestibility of algae by stomachless filter-feeding fish has been debated for decades. Results from gut contents and digestive enzyme analysis suggest poor utilization, while the measurement of food assimilation using radiolabeled isotope techniques indicate reasonable assimilation efficiency. Phytoplankton in the gut contents of the planktivorous filter-feeding silver carp were studied during March-May. The fish were cultured in a large net cage in a shallow, hypertrophic subtropical Chinese lake, Lake Donghu. In terms of biomass, the dominant phytoplankton in the fore-gut contents were Cyclotella (average 77.8%, range 69.7-93.5%) and Cryptomonas (average 9.57%, range 0-20.4%). The Ivlev's electivity index E of silver carp was much higher for Cyclotella (1.54) than for Cryptomonas (0.56). The majority of the phytoplankton found in the intestines of silver carp were 8-20 mu m, but they were also able to collect particles as small as 4.5-10 mu m, smaller than their filtering net meshes, suggesting that the secretion of mucus may play an important role in collecting such small particles. We conclude that disruption of cell walls is principally by the pharyngeal teeth, explaining previous contradictory conclusions. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical model for the spin filtering transport in a ferromagnetic-metal - Al2O3 - n-type semiconductor tunneling structure has been developed, and demonstrated that the ratio of the helicity-modulated photo-response to the chopped one is proportional to the sum of the relative asymmetry in conductance of two opposite spin-polarized tunneling channels and the MCD effect of the ferromagnetic metal film. The performed measurement in an iron-metal/Al2O3/n-type GaAs tunneling structure under the optical spin orientation has verified that all the aspects of the experimental results are very well in accordance with our model in the regime of the spin filtering. After the MCD effect of the iron film is calibrated by an independent measurement, the physical quantity of Delta G(t)/G(t) (Delta G(t) = G(t)(up arrow) - G(t)(down arrow) is the difference of the conductance between two opposite spin tunneling channels, G(t) =( G(t)(up arrow) + G(t)(down arrow))/2 the averaged tunneling conductance), which concerns us most, can be determined quantitatively with a high sensitivity in the framework of our analytical model. Copyright (c) EPLA, 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this letter, the power spectrum of a cooled distributed feedback laser module is measured using the self-heterodyne technique. Periodical oscillation peaks have been observed in the measurement. Further investigation shows that the additional modulation signal is coupled from the thermal electric cooler (TEC) controller to the laser driver, and then applied to the laser diode. The additional modulation can be eliminated by properly isolating the laser driving source from the TEC controller.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two simple methods for estimating the potential modulation bandwidth of TO packaging technique are presented. The first method is based upon the comparison of the measured frequency responses of the laser diodes and the TO laser modules, and the second is from the equivalent circuit for the test fixture, the TO header, the submount and the bonding wire. It is shown that the TO packaging techniques used in the experiments can potentially achieve a frequency bandwidth of over 10.5 GHz, and the two proposed methods give similar results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effects of techniques of implanting nitrogen into buried oxide on the characteristics of the partially depleted silicon-on-insulator (SOI) p-channel metal-oxide-semiconductor field-effect transistors (PMOSFETs) have been studied with three different nitrogen implantation doses, 8 x 10(15), 2 x 10(16), and 1 x 10(17) cm(-2). The experimental results show that this technology can affect the threshold voltage, channel hole mobility and output characteristics of the partially depleted SOI PMOSFETs fabricated with the given material and process. For each type of the partially depleted SOI PMOSFET with nitrided buried oxide, the absolute value of the average threshold voltage increases due to the nitrogen implantation. At the same time, the average channel hole mobility decreases because of the nitrogen implantation. In particular, with the high nitrogen implantation doses, the output characteristic curves of the tested transistors present a distinct kink effect, which normally exists in the characteristic output curves of only partially depleted SOI NMOSFETs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An add-drop filter based on a perfect square resonator can realize a maximum of only 25% power dropping because the confined modes are standing-wave modes. By means of mode coupling between two modes with inverse symmetry properties, a traveling-wave-like filtering response is obtained in a two-dimensional single square cavity filter with cut or circular corners by finite-difference time-domain simulation. The optimized deformation parameters for an add-drop filter can be accurately predicted as the overlapping point of the two coupling modes in an isolated deformed square cavity. More than 80% power dropping can be obtained in a deformed square cavity filter with a side length of 3.01 mu m. The free spectral region is decided by the mode spacing between modes, with the sum of the mode indices differing by 1. (c) 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scattering parameters of photodiode chip, TO header and TO packaged module are measured, and the effects of TO packaging network on the high-frequency response of photodiode are investigated. Based on the analysis, the potential bandwidth of TO packaging techniques is estimated from the scattering parameters of the TO packaging network. Another method for estimating the potential bandwidth from the equivalent circuit for the TO packaged photodiode model is also presented. The results obtained using both methods show that the TO packaging techniques used in the experiments can potentially achieve a frequency bandwidth of 22 GHz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current-based microscopic defect analysis method such as current deep level transient spectroscopy (I-DLTS) and thermally stimulated current have been developed over the years at Brookhaven National Laboratory (BNL) for the defect characterizations on heavily irradiated (Phi(n) >= 10(13) n/cm(2)) high-resistivity (>= 2 k Omega cm) Si sensors/detectors. The conventional DLTS method using a capacitance transient is not valid on heavily irradiated high-resistivity Si sensors/detectors. A new optical filling method, using lasers with various wavelengths, has been applied, which is more efficient and suitable than the traditional voltage-pulse filling. Optimum defect-filling schemes and conditions have been suggested for heavily irradiated high-resistivity Si sensors/detectors. (c) 2006 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A SiGe/Si multiple-quantum-well resonant-cavity-enhanced (RCE) photodetector for 1.3 mum operation was fabricated using bonding reflector process. A full width at half maximum (FWHM) of 6 nm and a quantum efficiency of 4.2% at 1314 nm were obtained. Compared to our previously reported SiGe RCE photodetectors fabricated on separation-by-implanted-oxygen wafer, the mirrors in the device can be more easily fabricated and the device can be further optimized. The FWHM is expected to be less than 1 nm and the detector is fit for density wavelength division multiplexing applications. (C) 2002 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conduction-band offset Delta E-C has been determined for a molecular beam epitaxy grown GaAs/In0.2Ga0.8As single quantum-well structure, by measuring the capacitance-voltage (C - V) profiling, taking into account a correction for the interface charge density, and the capacitance transient resulting from thermal emission of carriers from the quantum well, respectively. We found that Delta E-C = 0.227 eV, corresponding to about 89% Delta E-g, from the C - V profiling; and Delta E-C = 0.229eV, corresponding to about 89.9% Delta E-g, from the deep-level transient spectroscopy (DLTS) technique. The results suggest that the conduction-band discontinuity Delta E-C obtained from the C-V profiling is in good agreement with that obtained from the DLTS technique. (C) 1998 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current-based microscopic defect analysis method such as current deep level transient spectroscopy (I-DLTS) and thermally stimulated current have been developed over the years at Brookhaven National Laboratory (BNL) for the defect characterizations on heavily irradiated (Phi(n) >= 10(13) n/cm(2)) high-resistivity (>= 2 k Omega cm) Si sensors/detectors. The conventional DLTS method using a capacitance transient is not valid on heavily irradiated high-resistivity Si sensors/detectors. A new optical filling method, using lasers with various wavelengths, has been applied, which is more efficient and suitable than the traditional voltage-pulse filling. Optimum defect-filling schemes and conditions have been suggested for heavily irradiated high-resistivity Si sensors/detectors. (c) 2006 Published by Elsevier Ltd.