80 resultados para Angle measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The measurement accuracy of a parallel-plate interferometer for angular displacement measurement is analyzed. The measurement accuracy of angular displacement is not only related to the accuracy of phase extraction, but also related to initial incident angle, refraction index and thickness of plane-parallel plate as well as wavelength's stability of laser diode, etc. Theoretical analysis and computer simulation show that the measurement error of the angular displacement bears a minimum value when choosing an optimal initial incident angle in a large range. These analytical results serve as a guide in practical measurement. In this interferometer, reducing the refraction index or increasing the thickness of the parallel plate can improve the measurement accuracy; and the relative error of the phase measurement is 3.0 x 10(-4) corresponding to 1 degrees C temperature variation. Based on these theoretical and experimental results, the measurement accuracy of the parallel-plate interferometer is up to an order of 10(-8) rad. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The microstructures of hydrogenated microcrystalline silicon (tic-Si: H) thin films, prepared by plasma-enhanced chemical vapor deposition (PECVD), hot wire CVD(HWCVD) and plasma assisted HWCVD (PE-HWCVD), have been analyzed by the small angle x-ray scattering(SAXS) measurement. The SAXS data show that the microstructures of the μ c-Si: H films display different characteristics for different deposition techniques. For films deposited by PECVD, the volume fraction of micro-voids and mean size are smaller than those in HWCVD sample. Aided by suitable ion-bombardment, PE-HWCVD samples show a more compact structure than the HWCVD sample. The microstructure parameters of the μ c-Si: H thin films deposited by two-steps HWCVD and PE-HWCVD with Ar ions are evidently improved. The result of 45° tilting SAXS measurement indicates that the distribution of micro-voids in the film is anisotropic. The Fouriertransform infrared spectra confirm the SAXS data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The polyetherketone (PEK-c) guest-host polymer planar waveguides doped with (4'-nitro)-3-azo-9-ethyl-carbazole (NAEC) were prepared. The waveguide films were poled by corona-onset poling at elevated temperature (COPET), and the corona poling setup includes a grid voltage making the surface-charge distribution uniform. By using the prism-in coupling method, the dark-line spectrum given by the reflected intensity versus the angle of incidence have been obtained, and the optical transmission losses of mth modes have been measured for the poled polymer waveguides at lambda = 632.8 nm. The measurement result showed that the optical loss of the fundamental mode is less than 0.7 dB cm(-1) for the TE polarization. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The theoretical analysis and experimental measurement on the incident angle dependence of quantum efficiency of GaAs based resonant cavity enhanced (RCE) photodetector is presented. By changing the angle of incoming light, about 40 nm wavelength variation of peak quantum efficiency is obtained. The peak quantum efficiency and optical bandwidth at different mode corresponding to different angle incidence is characterized with different absorption dependence on wavelength. The convenient angle tuning of resonant mode will be helpful to relax the strict constraint of RCE photodetector to light source with narrow emission spectrum such applications in space optical detections and communications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transmission Volume Phase Holographic Grating (VPHG) is adopted as spectral element in the real-time Optical Channel Performance Monitor (OCPM), which is in dire need in the Dense Wavelength -division-multiplexing(DATDM) system. And the tolerance of incident angle, which can be fully determined by two angles: 6 and (p, is finally inferred in this paper. Commonly, the default setting is that the incident plane is perpendicular to the fringes when the incident angle is mentioned. Now the situation out of the vertical is discussed. By combining the theoretic analysis of VPHG with its use in OCPM and changing 6 and (0 precisely in the computation and experiment, the two physical quantities which can fully specify the performance of VPHG the diffraction efficiency and the resolution, are analyzed. The results show that the diffraction efficiency varies greatly with the change of 6 or (p. But from the view of the whole C-band, only the peak diffraction efficiency drifts to another wavelength. As for the resolution, it deteriorates more rapidly than diffraction efficiency with the change of (p, while more slowly with the change of theta. Only if \phi\less than or equal to+/-1degrees and alpha(B) -0.5 less than or equal to theta less than or equal to alpha(B) + 0.5, the performance of the VPHG would be good enough to be used in OCPM system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An external cavity semiconductor laser interferometer used to measure far distance micro-vibration in real time is proposed. In the interferometer, a single longitudinal mode and excellent coherent characteristic grating external cavity semiconductor laser is constructed and acted as a light source and a phase compensator. Its coherent length exceeds 200 meters. The angle between normal and incidence beam of the far object is allowed to change in definite range during the measurement with this interferometer, and this makes the far distance interference measurement easier and more convenient. Also, it is not required to keep the amplitudes of the first and second harmonic components equal, and then the dynamic range is increased. A feedback control system is used to compensate the phase disturbance between the two interference beams introduced by environmental vibration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The theoretical analysis and experimental measurement on the angle dependence of quantum efficiency of GaAs based resonant cavity enhanced (RCE) photodetector is presented. By changing the angle of incoming light, about 40mn wavelength variation of peak quantum efficiency has been experimentally obtained. The peak quantum efficiency and optical bandwidth at different mode corresponding to different angle incidence have been characterized with different absorption dependence on wavelength. The convenient angle tuning of resonant mode will be helpful to relax the strict constraint of RCE photodetector to light source with narrow emission spectrum while especially applied in space optical detections and communications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the construction of the neutron detection wall at the external target position on Heavy Ion Research Facility in Lanzhou-Cooling Storage Ring (HIRFL-CSR), it will be possible to detect high energy neutron. A BUU model is applied to simulate the flow in both symmetric (Ni+Ni, Pb+Pb) and asymmetric(Pb+Ni) systems. It is shown that at above several hundreds MeV/u, the flow signals are very obvious and depend clearly on the centrality of the collisions. Based on the products in the forward angle less than 20 degrees, the simulation also reveals that the determination of the reaction plane and the selection of the impact parameter, both of which are essential in the flow measurement, are well implemented. The double event and its influence on the determination of the neutron flow are also simulated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experiments of Al-23 and Mg-22 radioactive beams bombarding a C-12 target at an energy of 60 similar to 70 A MeV have been performed at the projectile fragment separator beamline (RIPS) in the RIKEN Ring Cyclotron Facility to study the two-proton emission from Al-23 and Mg-22 excited states, respectively. The trajectorie of the decay products, namely Na-21 + p + p from Al-23 and Ne-20 + p + p from Mg-22, are clean identified. The relative momentum and opening angle between two protons in the rest frame of three body decay channels are obtained by relativistic-kinematics reconstruction. The results demonstrate that there are some di-proton emission components from He-2 cluster for the excited Al-23 and Mg-22.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Scanning probe microscopy was used to simultaneously determine the molecular chain structure and intrinsic mechanical properties, including anisotropic elastic modulus and friction, for lamellae of highly oriented high-density polyethylene (HDPE) obtained by the melt-drawn method. The molecular-scale image of the highly oriented lamellae by friction force microscopy (FFM) clearly shows that the molecular chains are aligned parallel to the drawing direction, and the periodicities along and perpendicular to the drawing direction are 0.26 and 0.50 nm, respectively. The results indicate that the exposed planes of the lamellae resulting from the melt-drawn method are (200), which is consistent with results of transmission electron microscopy and electron diffraction. Because of the high degree of anisotropy in the sample, coming from alignment of the molecular chains along the drawing direction, the measured friction force, F, determined by FFM is strongly dependent on the angle, theta, between the scanning direction and the chain axis. The force increases as theta is increased from 0 degrees (i.e., parallel to the chain axis) to 90 degrees (i.e., perpendicular to the chain axis). The structural anisotropy was also found to strongly influence the measurements of the transverse chain modulus of the polymer by the nanoindentation technique. The measured value of 13.8 GPa with transverse modulus was larger than the value 4.3 GPa determined by wide-angle X-ray diffraction, which we attributed to anisotropic deformation of the lamellae during nanoindentation measurements that was not accounted for by the elastic treatment we adopted from Oliver and Pharr. The present approach using scanning probe microscopy has the advantage that direct correlations between the nanostructure, nanotribology, and nanomechanical properties of oriented samples can be determined simultaneously and simply.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal properties of a micro-electromechanical system sensor were analysed by a novel digital moire method. A double-layer micro-cantilever sensor (60 mu m long, 10 mu m width and 2 mu dm thick) was prepared by focused ion beam milling. A grating with frequency of 5000 lines mm- I was etched on the cantilever. The sensor was placed into a scanning electron microscope system with a high temperature device. The observation and recording of the thermal deformation of the grating were realised in real-time as the temperature rose from room temperature to 300 degrees C at intervals of 50 degrees C. Digital moire was generated by interference of the deformed grating and a digital virtual grating. The thermal properties including strain distribution of the sensor and the linear expansion coefficient of polysilicon were accurately measured by the phase-shifted moire patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes a new method for measuring the temperature of the gas behind the reflected shock wave in shock tube, corresponding to the reservoir temperature of a shock tunnel, based on the chemical reaction of small amount of CF4 premixed in the test gas. The final product C2F4 is used as the temperature indicator, which is sampled and detected by a gas chromatography in the experiment. The detected concentration of C2F4 is correlated to the temperature of the reflected shock wave with the initial pressure P-1 and test time tau as parameters in the temperature range 3 300 K < T < 5 600 K, pressure range 5 kPa < P1 <12 kPa and tau similar or equal to 0.4 ms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The property of crystal depends seriously on the solution concentration distribution near the growth surface of a crystal. However, the concentration distributions are affected by the diffusion and convection of the solution. In the present experiment, the two methods of optical measurement are used to obtained velocity field and concentration field of NaClO3 solution. The convection patterns in sodium chlorate (NaClO3) crystal growth are measured by Digital Particle image Velocimetry (DPIV) technology. The 2-dimentional velocity distributions in the solution of NaClO3 are obtained from experiments. And concentration field are obtained by a Mach-Zehnder interferometer with a phase shift servo system. Interference patterns were recorded directly by a computer via a CCD camera. The evolution of velocity field and concentration field from dissolution to crystallization are visualized clearly. The structures of velocity fields were compared with that of concentration field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present density measurements from the application of interferometry and Fourier transform fringe analysis to the problem of nonstationary shock wave reflection over a semicircular cylinder and compare our experimental measurements to theoretical results from a CFD simulation of the same problem. The experimental results demonstrate our ability to resolve detailed structure in this complex shock wave reflection problem, allowing visualization of multiple shocks in the vicinity of the triple point, plus visualization of the shear layer and an associated vortical structure. Comparison between CFD and experiment show significant discrepancies with experiment producing a double Mach Reflection when CFD predicts a transitional Mach reflection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the real-time deformation fields are observed in two different kinds of hole-excavated dog-bone samples loaded by an SHTB, including single hole sample and dual holes sample with the aperture size of 0.8mm. The testing system consists of a high-speed camera, a He-Ne laser, a frame grabber and a synchronization device with the controlling accuracy of I microsecond. Both the single hole expanding process and the interaction of the two holes are recorded with the time interval of 10 mu s. The observed images on the sample surface are analyzed by newly developed software based on digital correlation theory and a modified image processing method. The 2-D displacement fields in plane are obtained with a resolution of 50 mu m and an accuracy of 0.5 mu m. Experimental results obtained in this paper are proofed, by compared with FEM numerical simulations.