342 resultados para Gamma spectrometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental setup and the procedure for the laser resonant ionization mass spectrometry (RIMS) have been described. Both an optical spectrum and a mass spectum have been shown. The detection limit that can be reached by using this procedure has been estimated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article applied [HEH(HEP)] (2-ethyhexyldrogen-2-ethylhexyl phosphonate)extraction chromatography to separate 14 rare earth impurities from ultra-highly pure Er2O3 and Ho2O3, and then the impurities were determined by atomic emission spectrometry. The average percentage recovery for each element is in the range of 70%similar to 140%. The relative standard deviations of the determination are +/-3.3%similar to 2.2%. This method can be applied to the determination of the trace amounts of rare eath impurities in Er2O3 and Ho2O3 with a purity of 99.999 9%-99.999 99%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method was developed for the determination of total mercury in biological samples. The effects of aqueous ammonia, ethylenediamine and triethanolamine on Hg signal intensity by inductively coupled plasma mass spectrometry has been evaluated and the possible mechanisms discussed. It has been proved that the signal intensity of Hg significantly increases with adding, in the presence of small amounts of aqueous ammonia, ethylenediamine or triethanolamine. The normalized intensity (the signal intensity ratio with amine and without amine) of Hg increases as the concentration of aqueous ammonia, ethylenediamine or triethanolamine increases, but the degree of enhancement of aqueous ammonia was smaller than that of ethylenediamine and triethanolamine. The normalized intensity of Hg with aqueous ammonia, ethylenediamine and triethanolamine decreases as the nebulizer flow rate increases, but decreasing degree of aqueous ammonia was smaller than that of ethylenediamine and triethanolamine. The higher the RF powers the higher the normalized intensity of Hg at the same nebulizer flow rate. The addition of aqueous ammonia, ethylenediamine and triethanolamine into analytical solutions significantly improved the transport efficiency of Hg. The detection limit of Hg is improved about ten times by the addition of ethylenediamine or triethanolamine under the optimum experimental parameters. The method has been used to determine mercury in biological standard reference materials (SRM). The analytical results are very close to the certified values and the determined values for similar samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resonance electron capture mass spectrometry, in which an additional information coordinate, the energy of electron capture, is applied, has a high sensitivity and a high specificity. It is extensively used to study the structure elucidation, the mechanism of ion formation and the detection, identification and quantification of organic substances in mixture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cyclic aryletherketone( sulfone) oligomers containing hexafluoroisopropylidene unit were characterized by matrix-assisted laser desorption ionization time-of-night mass spectrometry(MALDI-TOF-MS) using Na+ and Ag+ as cationization agents. The affinities of cyclic oligomers to the cation were studied. The analysis result showed that 1,8,9-dithranol, in the presence of silver trifluoroacetate, was very effective for the characterization of cyclic arylether ketone ( sulfone) containing hexafluoroisopropylidene unit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purity and molecular weight of calmodulin have been determined by means of matrix-assisted laser desorption/ionization time of flight mass spectrometry, and the results have been discussed. The experimental results demonstrate that this method is high sensitive and rapid as compared with other traditional methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Target transformation factor analysis was used to correct spectral interference in inductively coupled plasma atomic emission spectrometry (ICP-BES) for the determination of rare earth impurities in high purity thulium oxide. Data matrix was constructed with pure and mixture vectors and background vector. A method based on an error evaluation function was proposed to optimize the peak position, so the influence of the peak position shift in spectral scans on the determination was eliminated or reduced. Satisfactory results were obtained using factor analysis and the proposed peak position optimization method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the determiantion of rare earth elements in biological sampels by inductively coupled plasma mass spectrometry was developed. Oxide ion yield of the rare earth elements (RFE) decreased with the increasing of RF power and the sampling depth, or with the decreasing of carrier gas flow rate. The spectral interference arising from (PrO)-Pr-141-O-16 on Gd-157 must be corrected. if the concentration of Ba was high enough, it was necessary to correct the spectral interference arising from (BO)-B-135-O-16 on Eu-151, and it was not necessary to correct spectral interference arising from (NdO)-Nd-143-O-16 on Tb-159 etc. in the biological samples under the selected operation parameters. In the biological sample, the major matrix elements, such as K, Na and Ca, result in the suppression of REEs signals and the suppression degree of the Ca is grezter than that of the K and Na. The mussel sample was digested by thd dry ashing, wet digestion with HNO3 + H2O2 and HNO3 + HClO4, respectively. The analytical results of REEs were consistent with each other. Detection limits for REEs are 0.001 similar to 0.013 mu g/L. Recoveries of standard addition are 91.7% similar to 125%. REEs in biological samples were determined directly without separation and preconcentration procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the analysis of mussel standard reference material by inductively coupled plasma atomic emission spectrometry( ICP-AES) and inductively coupled plasma mass spectrometry(ICP-MS) was developed. K, Na, Ca, Mg, P, Al, Fe, Zn, Mn and Sr were determined by ICP-AES and As, B, Cd, Co, Cr, Cu, Ga, Ge, Mn, Mo, Ni, Pb, Se, Sr, U and V by ICP-MS, The interference coefficients at the Mn-55, Se-78, Cu-63, Co-59, Ni-58, Ni-60, As-75, Se-77, V-51, Cr-53 and Cr-52 originating from polyatomic ion of the matrix elements (KO)-K-39-O-16, K-39(2), (ArNa)-Ar-40-Na-23, (CaO)-Ca-43-O-16, (CaO)-Ca-42-O-16, (CaO)-Ca-44-O-16, (PO2)-P-31-O-16, (ArCl)-Ar-40-Cl-35, (ArCl)-Ar-40-Cl-37, (ClO)-Cl-35-O-16, (ClO)-Cl-37-O-16 and (ArC)-Ar-40-C-12 were determined under the selected operation parameters. The major matrix elements, such as K, Na and Ca, result in the suppression of analytes signals. The apparent concentration at the significant biological element which was produced by the different digestion methods, (.) HNO3 + H2O2 (3 + 2), HNO3 + HClO4 (3 + 0.5) and HNO3 + H2SO4 (3 + 0.5),was determined. The sample digested by HNO3 + H2O2 did not give rise to interfere on the analyte, and the backgrounds of Se-77, Ga-69, Zn-67, As-75, V-51, Cr-53 and Cr-52 were increased by HNO3 + HClO4 digestion method, that affected the determination of these elements, especially the monoisotope As and V. Sample digested by HNO3 + H2SO4 increased the backgrounds at Cu-65, Zn-64 and Zn-67. Detection limits of ICP-AES are 0.001 similar to 0.75 mg/L and those of ICP-MS are 0.005 similar to 1.01 mu g/L. The relative standard derivations of ICP-AES and ICP-MS are 2.7% similar to 12.8%, 3.4% similar to 24.8%, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). The homogeneities and molecular weights of three arginine esterases from snake venom, which possessing therapeutic use in myocardial infarction, were determined and compared, MALDI-TOF-MS is possessed of high accuracy, high sensitivity and rapidity. MALDI-TOF-MS and sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) can provide complementary and confirmatory results information. MALDI-TOF-MS can be directly used as an important method for the purification of snake venom complexes successfully.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The matrix-assisted laser desorption ionization mass spectrometry (MALDI-TOF-MS) spectra of four enzymes (PLA, AEase, Fibrolase, L-a.a. oxidase) in Agkistrodon blomhoffii Ussurensis venom, were given and interpreted. The experiment data showed that MALDI-TOF-MS can be used directly in enzyme analysis with high sensitivity and rapidity. In addition, the results were better than those from sodium dodecyl sulfate-polyacrylamide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using electrospray ionization (ESI) and tandem mass spectrometry techniques, the protonic positions in protonated molecular ions of some narcotic drugs were studied, The data of ESI/MSn experiments of morphine and deuterium-loaded morphine were first discussed. The protonic position was considered to locate on oxygen atom of cyclic ether in morphine molecular, Compared with the same and different: ions among morphine, codeine, acetylcodeine and dihydrocodeine, the protonic positions in protonated molecular ions of these compounds were further determined. The fragmentation mechanism of morphine in ESI/MSn: experiments was also repored in the paper, and there were similar dehydrolysis mechanism in gas phase or in liquid phase for morphine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the quantatitive determination of pethidine in human urine by liquid secondary ion and tandem mass spectrometry is presented. Quantification was carried out by using ketamine as internal standard. It was found that the collision-induced dissociation (CID) spectrum of the [M + H](+) ion of pethidine exhibited a prominent daughter ion at mit 220 and ketamine also yielded the same daughter ion at nit 220, For ((quadrupole)) quantitative analysis, the first quadrupole mass filter was set to transmit mit 220 and a narrow-range magnet scan yielded a spectrum of parents, including mit 238 and 248, corresponding to ketamine and pethidine, respectively. Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies of low-energy collision-induced dissociation and isotopic labeling on ionized tetrahydroimidazole-substituted methylene P-diketones by tandem mass spectrometry showed that their unimolecular fragmentations may involve the reactions of intermediate ion/neutral complexes and multistep rearrangements. The corresponding mechanisms were proved by semiemipirical calculations of PM3 and AM1 methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The laser-desorption-ionization time-of-flight mass spectrometry and desorption-electron-ionization mass spectrometry were employed for the characterization of metallofullerenes extract. it was found that the relative intensities of metallofullerenes in this positive-ion, negative-ion LD-TOF MS and DEI MS were much different. This phenomenon should have relationship with the peculiar ionization energies and electron affinities of metallofullerenes.