206 resultados para flip-chip
Resumo:
It is impossible for surface plasmon resonance to measure directly the binding kinetics between a low-molecular-weight analyte interacting and its immobilized binding partner. Solution competition method was applied to the kinetic study of the interaction between morphine and its antibody. The affinity constant between the antibody of morphine and morphine-BSA immobilized on the sensor chip was also obtained. The result showed that the affinity of polyclonal antibody is stronger than that of monoclonal antibody. And it also indicated that the protein combined with the analyte affected the binding of antibody to antigen.
Resumo:
As a high efficiency separation technique, capillary electrophoresis(CE) has been widely used in various fields of analytical science. Amperometry is one of the most sensitive electrochemical detection methods in CE. The capillary/electrode decoupling mechanism, applications,of new electrode systems in CE, detection cell technique are discussed in detail. Amperometric detection is compatible with microfabricated CE chips and will make the concept of lab-on-a-chip become a reality. Because of these progresses, amperometry is becoming a widely acceptable detection method,for more chemical and biological analytes.
Resumo:
The kinetic analysis of the interaction between tumor necrosis factor(TNF) and its monoclonal antibody was performed by surface plasmon resonance(SPR) technique. The monoclonal antibody was immobilized to the surface of CM5 sensor chip by amine coupling. TNF at different concentrations was injected across the mAb immobilized surface. The interaction was recorded in real time and could be seen on the sensorgram. One cycle, including association, dissociation and regeneration, lasted no more than 15 min. The interaction results was evaluated using 1 : 1 Langmuir binding model. The kinetic rate constants were calculated to be: k =1.68 X 10(3) L (.) mol(-1) (.) s(-1), k(d) = 1.73 X 10(-4) s(-1), and the affinity constants K-A = 9. 7 X 10(3) L (.) mol(-1), K-r)= 1. 03 X 10(-7) Mol (.) L-1. The X-2 was 3.47, which showed that the interaction is consistent with the 1 : I model. We can see from the results that although there are two binding sites in one mAb molecule, TNF reacts with each site in an independent and noncooperative manner.
Resumo:
A surface plasmon resonance biosensor has been used to determine antibody activity in serum. As a model system, the interaction of mouse IgG and sheep anti-mouse IgG polyclonal antibody was investigated in real time. The factors, including pH value, ionic strength, protein concentration, influencing electrostatic adsorption of mouse IgG protein onto carboxylated dextran-coated sensor chip surface, were studied. The procedures of mouse IgG protein immobilization and immune reaction were monitored in real time. The regeneration effect using the different elution reagents was also investigated. The same mouse IgG immobilized surface can be used for 100 cycles of binding and elution with only 0.38% loss per regeneration in reactivity. The results show that the surface plasmon resonance biosensor is a rapid, simple, sensitive, accurate and reliable detection technique for real-time immunoassay of antibody activity. The assay allows antibodies to be detected and studied in their native form without any purification. (C) 2000 Elsevier Science B.V. All rights reserved.
Resumo:
The biosensor based on surface plasmon resonance(SPR) technology is a very useful tool to study the interaction between biomolecles. The main advantages of this technique is to "visualize" macromolecular interactions directly in real time, and in a label-free mode rather than indirect methods like enzyme-linked immunosorbent assays (ELISAs). We immobilize human serum albumin (HSA) to the carboxymethyldextran-modified sensor chip surface covalently to detect the activity of anti-HSA in serum, and regenerate the surface with .1 mol/L phosphoric acid. The results show that SPR biosensor can detect the activity of anti-HSA in real-time quickly and the sensor chip can be used over 100 cycles.
Resumo:
We have made a cheap microsystem of capillary electrophoresis with a new method, integrating the electrodes, injection channel, separation channel, buffer reservoirs and detection cell on a polymethylmethacrylate (PMMA) chip. Using an integrated micro carbon fiber disk electrode as the working electrode in three electrodes system, 1 x 10(-4) mol/L dopamine(DA) could be detected with end-column amperometric detection. The reproducibility was good. Peak current was 6.73 nA,theoretical plate number was 71300/m and height equivalent of one theoretical plate height was 14.0 mum for 1 x 10(-4) mol/L DA. The limit of detection was 3.6 x 10(-8) mol/L and the linear range was extended from 5 x 10(-7) mol/L to 1 x 10(-4) mol/L for DA. 1 x 10(-4) mol/L catechol (CA) and 5 x 10(-5) mol/L DA were also separated completely with R-s = 10.1.
Resumo:
研发了基于CAN总线的新型机器人示教盒系统,采用ARM芯片为核心,并在其上运行了实时操作系统μC/OS-II。设计了一套CAN网络通讯协议,实现了一个示教盒同时示教多台机器人的一对多示教模式,在很大程度上改进和提高了机器人示教盒的性能。
Resumo:
本文在分析几种常用的基于编码器测速方法的基础上,提出了一种高性能的自适应速度测量方法。该方法选择一个可变的时间周期和编码器脉冲数来测量单位时间内的编码器脉冲数,再通过简单的计算得到转速的测量值。数字信号处理器(DSP)芯片集成有正交脉冲编码电路,并且数据处理速度快,实时性强。本文中提出的方法在电机控制专用DSP芯片TMS320 LF2407A上进行了实现。实验研究表明,可以在提高低速时的测速准确度的同时,提高系统的响应时间。该方法已经在自主研发的全数字伺服驱动系统中得到了成功应用。
Resumo:
本文将S/T曲线速度规划的思想引入全数字伺服驱动系统中,通过提高速度的平滑性,特别是高速启、制动状态,来提高伺服系统的整体控制性能。基于定点数字信号处理器DSP芯片对提出的算法进行了实现。由于定点运算的限制,算法在实现中需要进行特殊的处理,本文对此进行了研究,并提出了一种余码补偿方案。实验研究表明,使用本文提出的方法可以提高系统运行的平稳性和控制的精确度。
Resumo:
介绍了数字信号处理器 TMS32 0 L F2 4 0 7A的串行外设接口 ,给出了 EEPROM存储器 X5 165与 TMS32 0 L F2 4 0 7A的硬件连接电路和应用程序实例
Resumo:
针对超大规模集成电路和片上系统设计中确定异步FIFO浓度的问题,根据异步FIFO运行时的属性提出FIFO动态参数模型,该模型包括FIFO饱和度、写入端和读出端数据传输率及上溢/下溢频率。在该模型的基础之上,分析异步FIFO的深度与动态参数之间的关系,采用功能仿真方法确定片上系统中异步模块之间数据传输所需FIFO的深度。对典型实例的分析表明,采用这种方法能够在保证系统数据通信性能的前提下,获得最小的FIFO深度,优化系统资源的使用。
Resumo:
针对环境温湿度检测的需求,设计了一种点对多点的星型无线温湿度监控网络。以无线通信模块nRF401为基础,配合AT89C2051和数字温湿度传感器SHT11构建了从机,以P89C51RD2BN单片机和USB接口芯片PDIUSBD12构建了主机。对系统的硬件原理及温湿度采集方法进行了介绍,对无线通信协议及USB固件设计方法进行了较详细分析。经上位机软件测试,系统运行稳定,具有较好实用性,可应用于多种场合的无线温湿度监测。
Resumo:
随着FPGA的发展,FPGA测试技术也得到了很快地发展。因为FPGA的结构和传统专用集成电路有着本质的区别,在FPGA中不能形成可测性设计电路,但它的可编程能力决定了其测试电路可以通过编程的方法来实现。本文讨论了XilinxXC4000系列FPGA中互连资源的自动测试方法。提出了一种新的测试资源坐标定位方法,使得测试软件能够将测试配置转换成器件配置,并搭建了硬件测试平台,实现实体FPGA芯片测试。
Resumo:
针对目前在纳米器件及传感器的制造中尚无对大量粒子进行有效操纵的方法,我们利用介电泳方法对大量微粒进行定位和传输操纵,介绍了利用MEMS工艺进行介电泳芯片加工的过程以及整个观测与实验系统的建立,通过有限元软件对传统介电泳和行波介电泳中电极阵列的电场分布进行求解,并在该实验系统下实现了对微通道中的悬浮高度和微粒的运动速度的测量.该实验系统的研究为液体环境下微纳颗粒的装配和分离提供了一条有效的技术路径.
Resumo:
介绍了16位80C196KC单片机的独特性能.组成由80C196KC单片机、存储器、光电编码器、模数转换器、键盘显示器、电机驱动电路等构成的测控系统.有针对性地提出了改进措施,并给出了HSO的应用实例.