104 resultados para measurement and metrology


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present paper the measured values of vibrational temperature behind strong shock waves are compared with theoretical ones. The histories of vibrational temperature behind strong shock waves in a shock tube were measured using two monochromators. The test gas was pure nitrogen at 100-300Pa, and the speeds of shock waves were 5.0-6.0km/s. The electronic temperature of N-2(+) was also approximately determined from experiment and compared with the experimental vibrational temperature. The results show that the presented calculational method is effective, and the electronic energy of N2+ is excited much faster than its vibrational energy. One Langmuir probe was used to determine the effective time of region 2. The influence of viscosity in the shock tube is also analyzed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode gain spectrum is measured by the Fourier series expansion method for InAs/GaAs quantum-dot (QD) lasers with seven stacks of QDs at different injection currents. Gain spectra with distinctive peaks are observed at the short and long wavelengths of about 1210 nm and 1300 nm. For a QD laser with the cavity length of 1060 mu m, the peak gain of the long wavelength first increases slowly or even decreases with the injection current as the peak gain of the short wavelength increases quickly, and finally increases quickly before approaching the saturated values as the injection current further increases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventional quantum trajectory theory developed in quantum optics is largely based on the physical unravelling of a Lindblad-type master equation, which constitutes the theoretical basis of continuous quantum measurement and feedback control. In this work, in the context of continuous quantum measurement and feedback control of a solid-state charge qubit, we present a physical unravelling scheme of a non-Lindblad-type master equation. Self-consistency and numerical efficiency are well demonstrated. In particular, the control effect is manifested in the detector noise spectrum, and the effect of measurement voltage is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The measurement and analysis of the microwave frequency response of semiconductor optical amplifiers (SOAs) are proposed in this paper. The response is measured using a vector network analyzer. Then with the direct-subtracting method, which is based on the definition of scattering parameters of optoelectronic devices, the responses of both the optical signal source and the photodetector are eliminated, and the response of only the SOA is extracted. Some characteristics of the responses can be observed: the responses are quasi-highpass; the gain increases with the bias current; and the response becomes more gradient while the bias current is increasing. The multisectional model of an SOA is then used to analyze the response theoretically. By deducing from the carrier rate equation of one section under the steady state and the small-signal state, the expression of the frequency response is obtained. Then by iterating the expression, the response of the whole SOA is simulated. The simulated results are in good agreement with the measured on the three main characteristics, which are also explained by the deduced results. This proves the validity of the theoretical analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The turn-on delay time jitter of four different unbiased gain-switched laser types is determined by measuring the temporal probability distribution of the leading edge of the emitted optical pulse. One single-mode 1.5-mu-m distributed feed-back laser and three multimode Fabry-Perot lasers emitting at 750 nm and 1.3-mu-m are investigated. The jitter is found to decrease for all lasers with increasing injection current. For multimode lasers it decreases from 8 ps excited slightly above threshold down to below 2 ps at three times the threshold current. The jitter of the distributed feedback (DFB) laser is a factor of 3-5 larger than the jitter of the three multimode lasers. A new model to predict the turn-on delay time jitter is presented and explains the experiments quantitatively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Penning trap, which can measure the atomic masses with the highest precision, is one of the most important facilities in nuclear physics research nowadays. The precision mass data play an important role in the studies of nuclear models, mass formulas, nuclear synthesis processes in the nuclear astrophysics, symmetries of the weak interaction and the conserved vector current (CVC) hypothesis. The status of high precision mass measurement around the world, the basic principle of Penning trap and the basic information about the LPT (Lanzhou Penning Trap) are introduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a laser induced sensitized fluorescence spectrometry for measuring the spontaneous emission branching ratios o?the transitions from the ten levels 5f36d7s7p-7M7, 5f36d7s7p-7L6, 5f37s27p-5K6, 5f26d27s2 - 5L7, 5f46d7s - 7L6, (17,070cm-1)-5L6, 5f26d27s2-5K6, 6d7s7p-7L5, 5f36d7s7p-7K5 and 5f26d27s2-5I5 to the ground state of atomic uranium (UI) for the first time. Their relative oscillator strengths have been measured by means of hollow cathode discharge (HCD) emission spectrometry. The radiative...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

提出了一种基于光栅成像投影的微位移检测方法,利用光学傅里叶变换原理给出了具体的理论分析。准直激光束照明的光栅通过一个4f系统成像投影在被测物体表面上,光栅投影经过被测物体表面反射后由另一个4f系统成像在探测光栅上。探测光栅由一个透镜组成像在光电探测器上,其中采用由起偏器、光弹调制器和检偏器组成的偏振调制单元对探测光强进行调制。通过在4f系统的频谱面上设置滤波光阑,在光电探测器上获得了与被测物体的微位移成正弦关系的光强变化,检测出光电探测器上的光强变化即可以获得被测物体的位移量。实验验证了该检测方法的可行性

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Determination of the energy range is an important precondition of focus calibration using alignment procedure (FOCAL) test. A new method to determine the energy range of FOCAL off-lined is presented in this paper. Independent of the lithographic tool, the method is time-saving and effective. The influences of some process factors, e.g. resist thickness, post exposure bake (PEB) temperature, PEB time and development time, on the energy range of FOCAL are analyzed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

提出一种步进扫描投影光刻机承片台不平度检测新技术。在晶圆与承片台存在不同偏移量时,利用线性差分传感器在线测量晶圆上不同点的局部高度;通过建立临时边界条件,以递推法消除晶圆面形影响,并逐行计算出承片台的相对不平度;通过逐行计算的结果递推相邻行之间的高度差,并将该高度差叠加到每一行,以消除临时边界条件的限制,得到处于同一高度上的承片台不平度;将计算的结果作为初始值,根据最小二乘原理,以邻近的四个测量点作为参考,逐步逼近得到承片台的真实不平度。计算机仿真结果验证了该检测方法的正确性,计算结果逐步收敛并逼近真实值

Relevância:

100.00% 100.00%

Publicador:

Resumo:

提出了一种基于基频分量消光的波片快轴标定方法,并利用琼斯矩阵对其标定原理进行了分析。激光器、起偏器、相位调制器、待标定1/4波片、检偏器和光电探测器构成标定光路,起偏器、检偏器的透光轴与相位调制器的振动轴分别成+45°和0°夹角。准直激光束依次经过起偏器、相位调制器、待标定1/4波片和检偏器,由光电探测器接收。理论分析表明该标定方法标定精度主要取决于检偏器的定位误差。实验验证了该标定方法的有效性,1/4波片快轴标定结果的最大偏差为0.043°,标准差为0.012°,标定精度为0.05°。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

分析了布里渊分布式光纤传感技术原理,采用自行研制的光纤单纵模分布反馈(DFB)激光器结合电光调制技术,利用相干检测技术,对布里渊微弱后向散射信号进行检测。通过改进滤波放大技术,对微弱后向散射光信号进行有效放大,再用扰偏技术及信号采样平均处理,实现对光纤传感器后向布里渊散射信号在11 GHz高频段直接采集显示。结果表明,探测所得布里渊散射信号峰值功率可达50 mV,能有效降低解调系统信号检测难度,改善了系统信噪比(SNR)。初步实验结果证明了该方案的可行性。