61 resultados para MULTIMODAL ELUTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper focuses on the study of carrier channels of multimodal-sized quantum dots formed on patterned substrate by a rate-equation-based model. Surface-mediated indium adatom migration is revealed by a direct comparison between quantum dot wetting layer, which acts as carrier channel, formed on a flat substrate and on a patterned substrate. For the assessment of suitability, the carrier channel of the dot-in-well structure has also been studied by the present model, and the transition energies of the carrier channel (e.g., InGaAs quantum well) obtained from theoretical simulation agree fairly well with those obtained from the reflectance measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have used Deep Level Transient Spectroscopy to investigate self-organized InAs/GaAs quantum dots. The existence of different dot families is confirmed by the deconvolution of the spectra in Gaussian components with full width at half maximum of 60-70meV. The strain of quantum dots is responsible for the relaxation of large quantum dots leading to generation of dislocations. (C) 1998 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A theoretical study on the velocity of electroosmotic flow (EOF) and the retention times of neutral solutes under multiple-step gradient of capillary electrochromatography (CEC) was carried out, focusing on that with three kinds of mobile phases. Through the model computations, the detaining time of the second kind of mobile phase in the column was proved to play an important role in affecting EOF. The variation speed of EOF was shown to be determined by the differences among dead times in different steps. In addition, the prediction of the retention times of 13 aromatic compounds under gradient mode was performed with the deduced equations. A relative error below 3.3% between the calculated and experimental values was obtained, which demonstrated the rationality of the theoretical deduction. Our study could not only improve the comprehension of stepwise gradient elution, but also be of significance for the further optimization of separation conditions in the analysis of complex samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Characteristics of electroosmotic flow (EOF) and the migration of neutral solutes under double stepwise gradient elution in capillary electrochromatography were studied systematically. EOF velocity proved to be the function of operation time changing with the introduction of the second mobile phase. Accordingly, the retention of components also changed. The migration of neutral solutes was studied under the following three situations; A, components eluted when the column was filled only with the first kind of mobile phase; B, solutes eluted still in the first kind of mobile phase while at that time two kinds of mobile phase coexisted in the column and C, samples eluted in the second kind of mobile phase. Equations to describe the retention times of components under these three kinds of conditions were deduced and applied to predict the retention times of 12 aromatic compounds. Relative errors between experimental and calculated values were below 5.0%, which proved the reliability of the equations. In addition, parameters that might affect the retention time of solutes, such as the transferring time of mobile phase vials, the capacity factors of components and EOF velocities two steps were studied systematically (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immersion in various media has different effect on the properties of dental composites, such as sorption, solubility, elution of unreacted monomers, flexural strength, and flexural elastic modulus. In the present work, the effect of immersion in various media and the relationship between the variation of these properties and the components of dental composite were investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The copolymer poly(L-lactic acid)-b-poly(L-cysteine) (PLA-b-PCys) was co-electrospun with PLGA into ultrafine fibers. The reduced glutathione (GSH) was conjugated to the fiber surfaces via disulfide bonds. The glutathione S-transferase (GST) was captured onto the GSH fibers via specific substrate-enzyme interaction between the bound GSH and GST. The captured GST was eluted with free GSH aqueous solution and lyophilized to get pure GST powders. The results show that the GSH moieties on the fiber surface retain the bioactivity of the free GSH and thus they can bind specifically with GST and the GST in solution is captured onto the fiber surface. In addition, the bound GSH is not as active as free GSH so that the captured GST can be eluted off from the fiber by free GSH aqueous solution. Based on this principle, GST itself or its fused proteins can be separated and purified very easily. The preliminary purification efficiency is 6.5 mg center dot(g(PCys))(-1). Further improvements are undertaken.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two commercial biaxially oriented polypropylene (BOPP) resins, resin A and resin B, having different processing properties, were fractionated by preparative temperature-rising elution fractionation (TREF). The TREF fractions were further characterized by gel permeation chromatography (GPC), gel permeation chromatography coupled with light scattering (GPC-LS), wide-angle X-ray diffraction (WAXD), and differential scanning calorimetry (DSC). GPC-LS did not find visible long-chain branching in either resin A or B. The results from TREF and DSC indicate that the fractional melting parameter f(T) may be used to predict the profile of the TREF cumulative weight distribution curve. GPC results show that the molecular weights of the fractions tend to increase with elution temperature. WAXD and DSC data show that the crystallinity of fractions does not increase monotonically with increase of elution temperature. There appears to be a maximum in the plot of crystallinity versus elution temperature. The high-speed BOPP resin A has a lower isotacticity but a homogeneous isotacticity distribution and a higher molecular weight but a broader molecular weight distribution than resin B.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an urgent need for thorough analysis of Radix astragali, a widely used Chinese herb, for quality control purposes. This paper describes the development of a total analytical method for Radix astragali extract, a multi-component complex mixture. Twenty-four components were separated step by step from the extract using a series of isocratic isopropanol-methanol elutions, and then 42 components were separated similarly using methanol-water elutions. Based on the log k(w) and -S of the 66 components obtained from the above procedure and the optimization software developed in our laboratory, an optimum elution program consisting of seven methanol-water segments and four isopropanol-methanol segments was developed to finish the task of analyzing the total components in a single run. Under optimized gradient conditions, the sample of Radix astragali extract was analyzed. As expected, most of the components were well separated and the experimental chromatogram was in a good agreement with the predicted one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the mass balance equations of solute transfer in the radial chromatographic column, the theoretical expression to describe the column efficiency and shape of elution profile is obtained under linear isotherm case. Moreover, the tendency for the variation of column efficiency and symmetry of peak profile is systematically discussed. The results showed that in radial chromatography the relationship between the column efficiency and volumetric flow rate is similar with that relationship in axial chromatography; relatively high column efficiency still can be obtained under high flow rate in radial chromatography. Accompanying the increase of retention factor of solutes and injection time, the column efficiency decreases monotonously. The effect of column diameter and column length on the column efficiency interfere with each other. It is more advantageous to increase the column efficiency by applying columns with larger column diameter and shorter column length. According to the discussion of the effect of diffusion on the column efficiency, radial chromatography is proved to be suitable for the separation of samples with relatively high diffusion coefficient, which predicts its obvious advantage in the preparative separation of samples such as proteins and DNA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gel filtration chromatography, ultra-filtration, and solid-phase extraction silica gel clean-up were evaluated for their ability to remove microcystins selectively from extracts of cyanobacteria Spirulina samples after using the reversed-phase octadecylsilyl ODS cartridge for subsequent analysis by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The reversed-phase ODS cartridge/silica gel combination were effective and the optimal wash and elution conditions were: H2O (wash), 20% methanol in water (wash), and 90% methanol in water (elution) for the reversed-phase ODS cartridge, followed by 80% methanol in water elution in the silica gel cartridge. The presence of microcystins in 36 kinds of cyanobacteria Spirulina health food samples obtained from various retail outlets in China were detected by LC-MS/MS, and 34 samples (94%) contained microcystins ranging from 2 to 163 ng g(-1) (mean=1427 ng g(-1)), which were significantly lower than microcystins present in blue green alga products previously reported. MC-RR-which contains two molecules of arginine (R)-(in 94.4% samples) was the predominant microcystin, followed by MC-LR-where L is leucine-(30.6%) and MC-YR-where Y is tyrose-(27.8%). The possible potential health risks from chronic exposure to microcystins from contaminated cyanobacteria Spirulina health food should not be ignored, even if the toxin concentrations were low. The method presented herein is proposed to detect microcystins present in commercial cyanobacteria Spirulina samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A rapid and sensitive method for separation and determination of Cr(VI) and Cr(III) in bottom mud of lake by flow injection on-line preconcentrtion system and GFAAS was developed. The available Cr(VI) and Cr(III) were extracted by HOAc or EDTA + NH4 NO3 and adsorbed simultaneously by an anion and a cation resin microclummn and then eluted simultaneously by 2 mol/L NH4 NO3 + 0.05 mol/L ascorbate and 2 mol/L H2SO4, respectively. The elution was performed for 50 s after adsorption for 2 min, and the efficiencies of elution were 85.4% - 94.8% and 96.7% - 106% for Cr(VI) and Cr(M) respectively. The detection limits of the method were 0.9 mu g/L and 2.7 mu g/L with relative standard deviations of 3.5% and 6.4% for the determination of Cr(VI) and Cr(III) in sample, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Continuous gradient elution chromatography (CGEC) was employed to purify and separate enzymes and polysaccharides from the sap of Rhus vernicifera Chinese lacquer tree. There are three different molecules with laccase enzyme activity. Two are enzymes of each other (L1, and L2), whereas the third (RL) is an entirely separate entity. Two polysaccharides (GP1 and GP2) were also found. The Rhus laccase (RL), and isoenzymes L1 and L2, have peak molecular masses of 109,100, 120,000, 103,000 respectively; each has four copper atoms per molecule, and the pI values were 8.2, 8.6, and 9.1, respectively. The structure of the laccases was studied by Fourier-transform infrared (FT-IR) and Matrix-assisted laser desorption/ionization time-of flight (MALDI-TOF) mass spectrometry. The typical amide I (1646 cm(-1)) and amide II (1545 cm(-1)) bands were observed. The results from MALDI-TOF were similar to those from CGEC, but the molecular mass from the MALDI-TOF was significantly different from that obtained from sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recognition-based user interface, users’ satisfaction is determined not only by recognition accuracy but also by effort to correct recognition errors. In this paper, we introduce a crossmodal error correction technique, which allows users to correct errors of Chinese handwriting recognition by speech. The focus of the paper is a multimodal fusion algorithm supporting the crossmodal error correction. By fusing handwriting and speech recognition, the algorithm can correct errors in both character extraction and recognition of handwriting. The experimental result indicates that the algorithm is effective and efficient. Moreover, the evaluation also shows the correction technique can help users to correct errors in handwriting recognition more efficiently than the other two error correction techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

将多通道交互用于虚拟环境,研究自然和谐的交互方式已经成为虚拟现实的一个重要研究方向.文中以城市规划为应用背景,融合跟踪器、语音和笔输入,提出概率合一的任务制导多通道整合,并辅以上下文语义;以此为基础,有针对性地设计了多通道交互技术,并依据多通道交互的特性分别进行阐述,实现了自然、高效的多通道虚拟城市规划.