96 resultados para Limit of detection
Resumo:
We report a new fluorescent detection method for cysteine based on one-step prepared fluorescent conjugated polymer-stabilized gold nanoparticles. The as-prepared fluorescent conjugated polymer-stabilized gold nanoparticles fluoresce weakly due to the fluorescence resonance energy transfer between the fluorophore and the gold nanoparticles. Upon the addition of cysteine, a thiol-containing amino acid, the fluorescence of the colloidal solution increases significantly, indicating that cysteine can modulate the energy transfer between fluorophore and gold. This phenomenon then allows for sensitive detection of cysteine with a limit of detection (LOD) of 25 nM. The linear range of determination of cysteine is from 5 x 10(-8) to 4 x 10(-6) M. None of the other amino acids found in proteins interferes with the determination. Moreover, due to the excellent protecting ability of the fluorescent conjugated polymers, the synthesis of metal nanoparticles and modifying with fluorophores can be accomplished within one step, which makes our method much simpler than conventional methods. We also expect that it will be possible to detect other biologically important analytes based on the fluorescent conjugated polymer-stabilized metal nanoparticles.
Resumo:
In this article, an antibiotic, lincomycin was determined in the urine sample by microchip capillary electrophoresis (CE) with integrated indium tin oxide (ITO) working electrode based on electrochemiluminescence (ECL) detection. This microchip CE-ECL system can be used for the rapid analysis of lincomycin within 40 s. Under the optimized conditions, the linear range was obtained from 5 to 100 muM with correlation coefficient of 0.998. The limit of detection (LOD) of 3.1 muM was obtained for lincomycin in the standard solution. We also applied this method to analyzing lincomycin in the urine matrix. The limit of detection of 9.0 muM was obtained. This method can determine lincomycin in the urine sample without pretreatment, which demonstrated that it is a promising method of detection of lincomycin in clinical and pharmaceutical area.
Resumo:
A capillary zone electrophoresis with end-column electrochemiluminescence (ECL) detector was described for the determination of benzhexol hydrochloride. The detection was based on the tris(2,2'-bypyridine)ruthenium(II) [Ru(bpy)(3)(2+)] ECL reaction with the analyte. Electrophoresis was performed using a 25 mum i.d. uncoated capillary. 10 mM sodium phosphate buffer (pH=8.0) was used as the running buffer. The solution in the detection cell was 80 mM sodium phosphate (pH=8.0) and 5 mM)21 Ru(bpy)(3)(2+). A linear calibration curve of three-orders of magnitude was obtained (with a correlation coefficient of > 0.999) from 1.0X10(-8) to 1.0X10(-5) M and the limit of detection was 6.7 X 10(-9) M (S/N= 3). This just provides an easy and sensitive method to determine the active ingredient in pharmaceutical formulations.
Resumo:
Tramadol and lidocaine, used as analgesic and local anesthetic in surgery, are partly excreted by kidney. For the first time, we developed a simple and sensitive method, based on capillary electrophoresis with electrochemiluminescence (ECL) detection by end column mode without joint to monitor tramadol and lidocaine in urine. To eliminate the influence of ionic strength of urine sample, analytes were extracted by ether. Tripropylamine (TPA) was used as internal standard. ne recoveries of tramadol and lidocaine were between 94% and 97% at different levels. The method exhibited the linear range for the tramadol and lidocaine from 1.0 X 10(-7) to 1.0 X 10(-4) mol/L with correlation efficient of 0.998. The relative standard deviation (RSD) was 2.9% and 2.7% (n = 8) for tramadol and lidocaine, respectively. The limit of detection (LOD) was 6.0 x 10(-8) mol/L and 4.5 x 10(-8), mol/L (S/N = 3) for tramadol and lidocaine, respectively. The application for detecting tramadol and lidocaine in urine of patients showed that the method was valuable in clinical and biochemical laboratories for detecting tramadol, lidocaine and other tertiary amine pharmaceuticals for various purpose, such as metabolism investigation.
Resumo:
Background: Capillary electrophoresis (CE) with tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)]-electro-generated chemiluminescence (ECL) detection is a promising method for clinical analysis. In this study, a method combining CE with Ru(bpy)(3)(2+) ECL (CE-ECL) detection that can be applied to amine-containing clinical species was developed, and the performance of CE-ECL as a quantitative method for determination of sulpiride in human plasma or urine was evaluated. Methods: Sulpiride was separated by capillary zone electrophoresis in uncoated fused-silica capillaries [510 cm x 25 mum (i.d.)] filled with phosphate buffer (pH 8.0 and a driving voltage of +15 kV, with end-column Ru(bpy)(3)(2+) ECL detection. A platinum disc electrode was used as working electrode. Sulpiride in human plasma or urine samples (100 muL) was extracted by a double-step liquid-liquid extraction procedure, dried under nitrogen at 35 degreesC in a water bath, and reconstituted with 100 muL of filtered water. The extraction solvent was ethyl acetate-dichloromethane (5:1 by volume). Results: Under optimum conditions (pH 8.0 phosphate buffer, injection for 6 s at 10 kV, and +1.2 V as detection potential), separation of sulpiride was accomplished within 4 min. The calibration curve was linear over a concentration range of 0.05-25.0 mumol/L, and the limit of detection was 2.9 x 10(-8) mol/L for sulpiride. Intra- and interday CVs for ECL intensities were <6%. Extraction recoveries of sulpiride were 95.6-101% with CVs of 2.9-6.0%. The method was,clinically validated for patient plasma and urine samples. Conclusions: CE combined with Ru(bpy)(3)(2+) ECL is reproducible, precise, selective, and enables the analysis of sulpiride in human plasma and urine. It thus is of value for rapid and efficient analysis of amine-containing analytes of clinical interest.
Resumo:
The p-toluene sulfonic acid (MA) in phenol matrix was separated and determined by capillary electrophoresis with ultraviolet detector. the effect of the concentration and pH of the buffer on separation was investigated. Cinnamic acid has been chosen as the internal standard from four compounds, the calibration curves of PTSA in 50 mg/L phenol matrix were obtained with and without the internal standard. The linear range was from 1.25 to 12.5 mg/L and the correlation coefficient was 0.9999 for both curves. The limit of detection of PISA was 0.75 mg/L at 3 times of SIN. Finally, the concentration of PTSA in four synthesized samples was determined with method of standard additions, and the effect of matrix was discussed. The values of MA in these samples were 1.01, 0.94, 1.56 and 0.00 mg/L respectively.
Resumo:
We have made a cheap microsystem of capillary electrophoresis with a new method, integrating the electrodes, injection channel, separation channel, buffer reservoirs and detection cell on a polymethylmethacrylate (PMMA) chip. Using an integrated micro carbon fiber disk electrode as the working electrode in three electrodes system, 1 x 10(-4) mol/L dopamine(DA) could be detected with end-column amperometric detection. The reproducibility was good. Peak current was 6.73 nA,theoretical plate number was 71300/m and height equivalent of one theoretical plate height was 14.0 mum for 1 x 10(-4) mol/L DA. The limit of detection was 3.6 x 10(-8) mol/L and the linear range was extended from 5 x 10(-7) mol/L to 1 x 10(-4) mol/L for DA. 1 x 10(-4) mol/L catechol (CA) and 5 x 10(-5) mol/L DA were also separated completely with R-s = 10.1.
Resumo:
Chromatography-amperometric detection of nitrite with a polypyrrole modified glassy carbon electrode doped with tungstodiphosphate anion (Dawson-type P2W18O626-/PPy/GC electrode) based on its electrocatalytic reduction of nitrite is described. The cyclic and hydrodynamic voltammetry of nitrite at the P2W18O626-/PPy/GC electrode was studied. The factors affecting the detection of nitrite and the analytical performance of the modified electrode in flowing stream were investigated. The results show that the modified electrode has a good sensitivity (the limit of detection is 1 mu mol dm(-3)) and a satisfactory reproducibility (RSD = 3.78%, N = 21). The modified electrode was used in the chromatographic detection of nitrite spiked in the liquid from a tin of mushrooms and the mineralized spring water. It was found that the modified electrode exhibited good selectivity for nitrite.
Resumo:
A Prussian Blue-modified glassy carbon electrode prepared by simple adsorption exhibited excellent electrocatalytic activity in the oxidation of hydrazine in acidic media. A film of the perfluorosulphonic acid polymer Nafion coated on top of the Prussian Blue-modified glassy carbon electrode can improve the mechanical stability of the Prussian Blue layer in the flow stream. Hydrazine was detected by flow-injection analysis at the modified electrode with high sensitivity. The limit of detection was 0.6 ng.
Resumo:
Chemically modified electrodes prepared by adsorbing prussian blue on a glassy carbon electrode are shown to catalyse the electro-oxidation of cysteine, N-acetylcysteine and glutathione in acidic media. The catalytic response is evaluated with respect to the potential scan rate, the solution pH, the concentration dependence, and other variables. Covering the electrode with Nafion(R) film improved the stability and reproducibility in liquid chromatography with electrochemical detection to the extent that repetitive sample injections produced relative standard deviations of less than 5% over several hours of operation. The limit of detection was 4 pmol for cysteine, 33 pmol for glutathione and 61 pmol for N-acetylcysteine.
Resumo:
A liquid chromatography electrospray mass spectrometry (LC/ESI/MS) method working in multiple reactions monitoring mode for the determination of trace amounts of microcystin variants (MC-LR and [Dha(7)] MC-LR) in waters was developed. The limit of quantification was 0.05 mu g/L and the limit of detection was 0.015 mu g/L for MC-LR and [Dha(7)] MC-LR, respectively. Recoveries for MCs were in the range of 68%-81%. MC-LR and [Dha(7)] MC-LR were chemically stable with similar physiochemical behavior.
Resumo:
A rapid and sensitive method was developed and validated for the determination of MCYST (microcystin)-RR, -LR, and [Dha(7)] MCYST-LR in rat plasma by liquid chromatography-tandem mass spectrometry. The analytes were extracted from rat plasma by protein precipitation, followed by solid-phase extraction. Liquid chromatography with electrospray ionization mass spectrometry, operating in selected reaction monitoring (SRM) mode, was used to quantify MCYST-RR, -LR, and [Dha(7)] MCYST-LR in rat plasma. The recoveries for each analyte in rat plasma ranged from 70.8 to 88.7%. The calibration curve was linear within the range from 0.005 to 1.25 mu g mL(-1). The limit of detection were 1.4, 1.0, 0.6 ng mL(-1) for MCYST-RR, -LR, and [Dha(7)] MCYST-LR. The overall precision was determined on three different days. The values for within- and between-day precision in rat plasma were within 15%. This method was applied to the identification and quantification of microcystins in rat plasma with acute exposure of microcystins via intravenous injection.
Resumo:
An acute toxicity experiment was conducted by intraperitoneal injection with a sublethal dose of extracted microcystins (MCs), 50 mu g MC-LR (where L = leucine and R = arginine) equivalent/kg body weight (BW), to examine tissue distribution and depuration of MCs in crucian carp (Carassius carassius). Liver to body weight ratio increased at 3, 12, 24, and 48 h postinjection compared with that at 0 h (p < 0.05). MC concentrations in various tissues and aquaria water were analyzed at 1, 3, 12, 24, 48, and 168 h postinjection using liquid chromatography coupled with mass spectrometry (LC-MS). The highest concentration of MCs (MC-RR + MC-LR) was found in blood, 2 -270 ng/g dry weight (DW), followed by heart (3 -100 ng/g DW) and kidney (13 -88 ng/g DW). MC levels were relatively low in liver, gonad, intestine, spleen, and brain. MC contents in gills, gallbladder, and muscle were below the limit of detection. Significant negative correlation was present between MC-RR concentration in blood and that in kidney, confirming that blood was important in the transportation of MC-RR to kidney for excretion. Rapid accumulation and slow degradation of MCs were observed in gonad, liver, intestine, spleen, and brain. Only 0.07% of injected MCs were detected in liver. The recovery of MCs in liver of crucian carp seemed to be dose dependent.