19 resultados para Water Distribution Networks Infrastructure Health

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Through the use of the Distributed Fiber Optic Temperature Measurement (DFOT) method, it is possible to measure the temperature in small intervals (on the order of centimeters) for long distances (on the order of kilometers) with a high temporal frequency and great accuracy. The heat pulse method consists of applying a known amount of heat to the soil and monitoring the temperature evolution, which is primarily dependent on the soil moisture content. The use of both methods, which is called the active heat pulse method with fiber optic temperature sensing (AHFO), allows accurate soil moisture content measurements. In order to experimentally study the wetting patterns, i.e. shape, size, and the water distribution, from a drip irrigation emitter, a soil column of 0.5 m of diameter and 0.6 m high was built. Inside the column, a fiber optic cable with a stainless steel sheath was placed forming three concentric helixes of diameters 0.2 m, 0.4 m and 0.6 m, leading to a 148 measurement point network. Before, during, and after the irrigation event, heat pulses were performed supplying electrical power of 20 W/m to the steel. The soil moisture content was measured with a capacitive sensor in one location at depths of 0.1 m, 0.2 m, 0.3 m and 0.4 m during the irrigation. It was also determined by the gravimetric method in several locations and depths before and right after the irrigation. The emitter bulb dimensions and shape evolution was satisfactorily measured during infiltration. Furthermore, some bulb's characteristics difficult to predict (e.g. preferential flow) were detected. The results point out that the AHFO is a useful tool to estimate the wetting pattern of drip irrigation emitters in soil columns and show a high potential for its use in the field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In pressure irrigation-water distribution networks, pressure regulating devices for controlling the discharged flow rate by irrigation units are needed due to the variability of flow rate. In addition, applied water volume is used controlled operating the valve during a calculated time interval, and assuming constant flow rate. In general, a pressure regulating valve PRV is the commonly used pressure regulating device in a hydrant, which, also, executes the open and close function. A hydrant feeds several irrigation units, requiring a wide range in flow rate. In addition, some flow meters are also available, one as a component of the hydrant and the rest are placed downstream. Every land owner has one flow meter for each group of field plots downstream the hydrant. Its lecture could be used for refining the water balance but its accuracy must be taken into account. Ideal PRV performance would maintain a constant downstream pressure. However, the true performance depends on both upstream pressure and the discharged flow rate. The objective of this work is to asses the influence of the performance on the applied volume during the whole irrigation events in a year. The results of the study have been obtained introducing the flow rate into a PRV model. Variations on flow rate are simulated by taking into account the consequences of variations on climate conditions and also decisions in irrigation operation, such us duration and frequency application. The model comprises continuity, dynamic and energy equations of the components of the PRV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this article the network configuration for fulfillment and distribution of online orders of two British retailers is analyzed and compared. For this purpose, it is proposed a conceptual framework that consists of the key following aspects: network configuration, transportation management and location of demand. As a result is not obvious to determine the ideal centralization degree in each case. Finally, it is suggested the future development of an analytic tool that helps to choose the most appropriate model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In pressure irrigation-water distribution networks, applied water volume is usually controlled opening a valve during a calculated time interval, and assuming constant flow rate. In general, pressure regulating devices for controlling the discharged flow rate by irrigation units are needed due to the variability of pressure conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new selective and non-directional protection method to detect ground faults in neutral isolated power systems. The new proposed method is based on the comparison of the rms value of the residual current of all the lines connected to a bus, and it is able to determine the line with ground defect. Additionally, this method can be used for the protection of secondary substation. This protection method avoids the unwanted trips produced by wrong settings or wiring errors, which sometimes occur in the existing directional ground fault protections. This new method has been validated through computer simulations and experimental laboratory tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pressure management (PM) is commonly used in water distribution systems (WDSs). In the last decade, a strategic objective in the field has been the development of new scientific and technical methods for its implementation. However, due to a lack of systematic analysis of the results obtained in practical cases, progress has not always been reflected in practical actions. To address this problem, this paper provides a comprehensive analysis of the most innovative issues related to PM. The methodology proposed is based on a case-study comparison of qualitative concepts that involves published work from 140 sources. The results include a qualitative analysis covering four aspects: (1) the objectives yielded by PM; (2) types of regulation, including advanced control systems through electronic controllers; (3) new methods for designing districts; and (4) development of optimization models associated with PM. The evolution of the aforementioned four aspects is examined and discussed. Conclusions regarding the current status of each factor are drawn and proposals for future research outlined

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La presente Tesis plantea una metodología de análisis estadístico de roturas de tubería en redes de distribución de agua, que analiza la relación entre las roturas y la presión de agua y que propone la implantación de una gestión de presiones que reduzca el número de roturas que se producen en dichas redes. Las redes de distribución de agua se deterioran y una de sus graves consecuencias es la aparición de roturas frecuentes en sus tuberías. Las roturas llevan asociados elevados costes sociales, económicos y medioambientales y es por ello por lo que las compañías gestoras del agua tratan de reducirlas en la medida de lo posible. Las redes de distribución de agua se pueden dividir en zonas o sectores que facilitan su control y que pueden ser independientes o aislarse mediante válvulas, como ocurre en las redes de países más desarrollados, o pueden estar intercomunicados hidráulicamente. La implantación de una gestión de presiones suele llevarse a cabo a través de las válvulas reductoras de presión (VPR), que se instalan en las cabeceras de estos sectores y que controlan la presión aguas abajo de la misma, aunque varíe su caudal de entrada. Los métodos más conocidos de la gestión de presiones son la reducción de presiones, que es el control más habitual, el mantenimiento de la presión, la prevención y/o alivio de los aumentos repentinos de presión y el establecimiento de un control por alturas. A partir del año 2005 se empezó a reconocer el efecto de la gestión de presiones sobre la disminución de las roturas. En esta Tesis, se sugiere una gestión de presiones que controle los rangos de los indicadores de la presión de cabecera que más influyan en la probabilidad de roturas de tubería. Así, la presión del agua se caracteriza a través de indicadores obtenidos de la presión registrada en la cabecera de los sectores, debido a que se asume que esta presión es representativa de la presión de operación de todas las tuberías porque las pérdidas de carga son relativamente bajas y las diferencias topográficas se tienen en cuenta en el diseño de los sectores. Y los indicadores de presión, que se pueden definir como el estadístico calculado a partir de las series de la presión de cabecera sobre una ventana de tiempo, pueden proveer la información necesaria para ayudar a la toma de decisiones a los gestores del agua con el fin de reducir las roturas de tubería en las redes de distribución de agua. La primera parte de la metodología que se propone en esta Tesis trata de encontrar los indicadores de presión que influyen más en la probabilidad de roturas de tuberías. Para conocer si un indicador es influyente en la probabilidad de las roturas se comparan las estimaciones de las funciones de distribución acumulada (FDAs) de los indicadores de presiones, considerando dos situaciones: cuando se condicionan a la ocurrencia de una rotura (suceso raro) y cuando se calculan en la situación normal de operación (normal operación). Por lo general, las compañías gestoras cuentan con registros de roturas de los años más recientes y al encontrarse las tuberías enterradas se complica el acceso a la información. Por ello, se propone el uso de funciones de probabilidad que permiten reducir la incertidumbre asociada a los datos registrados. De esta forma, se determinan las funciones de distribución acumuladas (FDAs) de los valores del indicador de la serie de presión (situación normal de operación) y las FDAs de los valores del indicador en el momento de ocurrencia de las roturas (condicionado a las roturas). Si las funciones de distribución provienen de la misma población, no se puede deducir que el indicador claramente influya en la probabilidad de roturas. Sin embargo, si se prueba estadísticamente que las funciones proceden de la misma población, se puede concluir que existe una relación entre el indicador analizado y la ocurrencia de las roturas. Debido a que el número de valores del indicador de la FDA condicionada a las roturas es mucho menor que el número de valores del indicador de la FDA incondicional a las roturas, se generan series aleatorias a partir de los valores de los indicadores con el mismo número de valores que roturas registradas hay. De esta forma, se comparan las FDAs de series aleatorias del indicador con la FDA condicionada a las roturas del mismo indicador y se deduce si el indicador es influyente en la probabilidad de las roturas. Los indicadores de presión pueden depender de unos parámetros. A través de un análisis de sensibilidad y aplicando un test estadístico robusto se determina la situación en la que estos parámetros dan lugar a que el indicador sea más influyente en la probabilidad de las roturas. Al mismo tiempo, los indicadores se pueden calcular en función de dos parámetros de cálculo que se denominan el tiempo de anticipación y el ancho de ventana. El tiempo de anticipación es el tiempo (en horas) entre el final del periodo de computación del indicador de presión y la rotura, y el ancho de ventana es el número de valores de presión que se requieren para calcular el indicador de presión y que es múltiplo de 24 horas debido al comportamiento cíclico diario de la presión. Un análisis de sensibilidad de los parámetros de cálculo explica cuándo los indicadores de presión influyen más en la probabilidad de roturas. En la segunda parte de la metodología se presenta un modelo de diagnóstico bayesiano. Este tipo de modelo forma parte de los modelos estadísticos de prevención de roturas, parten de los datos registrados para establecer patrones de fallo y utilizan el teorema de Bayes para determinar la probabilidad de fallo cuando se condiciona la red a unas determinadas características. Así, a través del teorema de Bayes se comparan la FDA genérica del indicador con la FDA condicionada a las roturas y se determina cuándo la probabilidad de roturas aumenta para ciertos rangos del indicador que se ha inferido como influyente en las roturas. Se determina un ratio de probabilidad (RP) que cuando es superior a la unidad permite distinguir cuándo la probabilidad de roturas incrementa para determinados intervalos del indicador. La primera parte de la metodología se aplica a la red de distribución de la Comunidad de Madrid (España) y a la red de distribución de Ciudad de Panamá (Panamá). Tras el filtrado de datos se deduce que se puede aplicar la metodología en 15 sectores en la Comunidad de Madrid y en dos sectores, llamados corregimientos, en Ciudad de Panamá. Los resultados demuestran que en las dos redes los indicadores más influyentes en la probabilidad de las roturas son el rango de la presión, que supone la diferencia entre la presión máxima y la presión mínima, y la variabilidad de la presión, que considera la propiedad estadística de la desviación típica. Se trata, por tanto, de indicadores que hacen referencia a la dispersión de los datos, a la persistencia de la variación de la presión y que se puede asimilar en resistencia de materiales a la fatiga. La segunda parte de la metodología se ha aplicado a los indicadores influyentes en la probabilidad de las roturas de la Comunidad de Madrid y se ha deducido que la probabilidad de roturas aumenta para valores extremos del indicador del rango de la presión y del indicador de la variabilidad de la presión. Finalmente, se recomienda una gestión de presiones que limite los intervalos de los indicadores influyentes en la probabilidad de roturas que incrementen dicha probabilidad. La metodología propuesta puede aplicarse a otras redes de distribución y puede ayudar a las compañías gestoras a reducir el número de fallos en el sistema a través de la gestión de presiones. This Thesis presents a methodology for the statistical analysis of pipe breaks in water distribution networks. The methodology studies the relationship between pipe breaks and water pressure, and proposes a pressure management procedure to reduce the number of breaks that occur in such networks. One of the manifestations of the deterioration of water supply systems is frequent pipe breaks. System failures are one of the major challenges faced by water utilities, due to their associated social, economic and environmental costs. For all these reasons, water utilities aim at reducing the problem of break occurrence to as great an extent as possible. Water distribution networks can be divided into areas or sectors, which facilitates the control of the network. These areas may be independent or isolated by valves, as it usually happens in developing countries. Alternatively, they can be hydraulically interconnected. The implementation of pressure management strategies is usually carried out through pressure-reducing valves (PRV). These valves are installed at the head of the sectors and, although the inflow may vary significantly, they control the downstream pressure. The most popular methods of pressure management consist of pressure reduction, which is the common form of control, pressure sustaining, prevention and/or alleviation of pressure surges or large variations in pressure, and level/altitude control. From 2005 onwards, the effects of pressure management on burst frequencies have become more widely recognized in the technical literature. This thesis suggests a pressure management that controls the pressure indicator ranges most influential on the probability of pipe breaks. Operating pressure in a sector is characterized by means of a pressure indicator at the head of the DMA, as head losses are relatively small and topographical differences were accounted for at the design stage. The pressure indicator, which may be defined as the calculated statistic from the time series of pressure head over a specific time window, may provide necessary information to help water utilities to make decisions to reduce pipe breaks in water distribution networks. The first part of the methodology presented in this Thesis provides the pressure indicators which have the greatest impact on the probability of pipe breaks to be determined. In order to know whether a pressure indicator influences the probability of pipe breaks, the proposed methodology compares estimates of cumulative distribution functions (CDFs) of a pressure indicator through consideration of two situations: when they are conditioned to the occurrence of a pipe break (a rare event), and when they are not (a normal operation). Water utilities usually have a history of failures limited to recent periods of time, and it is difficult to have access to precise information in an underground network. Therefore, the use of distribution functions to address such imprecision of recorded data is proposed. Cumulative distribution functions (CDFs) derived from the time series of pressure indicators (normal operation) and CDFs of indicator values at times coincident with a reported pipe break (conditioned to breaks) are compared. If all estimated CDFs are drawn from the same population, there is no reason to infer that the studied indicator clearly influences the probability of the rare event. However, when it is statistically proven that the estimated CDFs do not come from the same population, the analysed indicator may have an influence on the occurrence of pipe breaks. Due to the fact that the number of indicator values used to estimate the CDF conditioned to breaks is much lower in comparison with the number of indicator values to estimate the CDF of the unconditional pressure series, and that the obtained results depend on the size of the compared samples, CDFs from random sets of the same size sampled from the unconditional indicator values are estimated. Therefore, the comparison between the estimated CDFs of random sets of the indicator and the estimated CDF conditioned to breaks allows knowledge of if the indicator is influential on the probability of pipe breaks. Pressure indicators depend on various parameters. Sensitivity analysis and a robust statistical test allow determining the indicator for which these parameters result most influential on the probability of pipe breaks. At the same time, indicators can be calculated according to two model parameters, named as the anticipation time and the window width. The anticipation time refers to the time (hours) between the end of the period for the computation of the pressure indicator and the break. The window width is the number of instantaneous pressure values required to calculate the pressure indicator and is multiple of 24 hours, as water pressure has a cyclical behaviour which lasts one day. A sensitivity analysis of the model parameters explains when the pressure indicator is more influential on the probability of pipe breaks. The second part of the methodology presents a Bayesian diagnostic model. This kind of model belongs to the class of statistical predictive models, which are based on historical data, represent break behavior and patterns in water mains, and use the Bayes’ theorem to condition the probability of failure to specific system characteristics. The Bayes’ theorem allows comparing the break-conditioned FDA and the unconditional FDA of the indicators and determining when the probability of pipe breaks increases for certain pressure indicator ranges. A defined probability ratio provides a measure to establish whether the probability of breaks increases for certain ranges of the pressure indicator. The first part of the methodology is applied to the water distribution network of Madrid (Spain) and to the water distribution network of Panama City (Panama). The data filtering method suggests that the methodology can be applied to 15 sectors in Madrid and to two areas in Panama City. The results show that, in both systems, the most influential indicators on the probability of pipe breaks are the pressure range, which is the difference between the maximum pressure and the minimum pressure, and pressure variability, referred to the statistical property of the standard deviation. Therefore, they represent the dispersion of the data, the persistence of the variation in pressure and may be related to the fatigue in material resistance. The second part of the methodology has been applied to the influential indicators on the probability of pipe breaks in the water distribution network of Madrid. The main conclusion is that the probability of pipe breaks increases for the extreme values of the pressure range indicator and of the pressure variability indicator. Finally, a pressure management which limits the ranges of the pressure indicators influential on the probability of pipe breaks that increase such probability is recommended. The methodology presented here is general, may be applied to other water distribution networks, and could help water utilities reduce the number of system failures through pressure management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Es objeto del presente proyecto definir red inteligente (Smart Grid) como parte fundamental de un futuro sistema de generación, distribución y transporte de la energía, utilizando como medio principal de desplazamiento el Vehículo Eléctrico. El desarrollo del proyecto se lleva a cabo a través de un análisis exhaustivo del impacto de la introducción masiva del Vehículo Eléctrico en las redes de distribución. Para evaluar las simulaciones se han creado unos niveles de penetración de vehículos, así como el despliegue de dispositivos de recarga y hora óptima de conexión a la red para que la curva de demanda se suavice lo máximo posible y las infraestructuras eléctricas no sufran una sobrecarga provocando una caída del sistema eléctrico. Con un software específico, se ha obtenido un porcentaje de pérdidas y se han sacado unas conclusiones para los distintos casos de penetración del vehículo eléctrico. Asimismo, se ha analizado la implementación de un sistema que estudie los intercambios energéticos que se producen entre los diferentes sistemas del vehículo, y entre éste y su entorno para poder disminuir las pérdidas. ABSTRACT The objective of this project is to define Smart Grid as an essential part of a future generation system, distribution and transmission of energy, using Electric Vehicle as primary mean of moving. The development of this project was carried out through a comprehensive analysis of the impact of the massive introduction of electric vehicles in distribution networks. To evaluate the simulations, different indicators for vehicle´s penetration were created, as well as the deployment of charging devices and optimal time to get network connection in order to smooth the demand curve as much as possible and to avoid electrical infrastructure being overloaded and thus causing the electrical system to stop working. For each of the different cases of electric vehicles’ penetration a percentage of losses and conclusions were drawn using specific software. The implementation of a system that studies the exchanges of energy that occur between different vehicle systems and between itself and its environment to reduce losses was also analyzed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rising water demands are difficult to meet in many regions of the world. In consequence, under meteorological adverse conditions, big economic losses in agriculture can take place. This paper aims to analyze the variability of water shortage in an irrigation district and the effect on farmer?s income. A probabilistic analysis of water availability for agriculture in the irrigation district is performed, through a supply-system simulation approach, considering stochastically generated series of stream-flows. Net margins associated to crop production are as well estimated depending on final water allocations. Net margins are calculated considering either single-crop farming, either a polyculture system. In a polyculture system, crop distribution and water redistribution are calculated through an optimization approach using the General Algebraic Modeling System (GAMS) for several scenarios of irrigation water availability. Expected net margins are obtained by crop and for the optimal crop and water distribution. The maximum expected margins are obtained for the optimal crop combination, followed by the alfalfa monoculture, maize, rice, wheat and finally barley. Water is distributed as follows, from biggest to smallest allocation: rice, alfalfa, maize, wheat and barley.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spatial variability of Vertisol properties is relevant for identifying those zones with physical degradation. In this sense, one has to face the problem of identifying the origin and distribution of spatial variability patterns. The objectives of the present work were (i) to quantify the spatial structure of different physical properties collected from a Vertisol, (ii) to search for potential correlations between different spatial patterns and (iii) to identify relevant components through multivariate spatial analysis. The study was conducted on a Vertisol (Typic Hapludert) dedicated to sugarcane (Saccharum officinarum L.) production during the last sixty years. We used six soil properties collected from a squared grid (225 points) (penetrometer resistance (PR), total porosity, fragmentation dimension (Df), vertical electrical conductivity (ECv), horizontal electrical conductivity (ECh) and soil water content (WC)). All the original data sets were z-transformed before geostatistical analysis. Three different types of semivariogram models were necessary for fitting individual experimental semivariograms. This suggests the different natures of spatial variability patterns. Soil water content rendered the largest nugget effect (C0 = 0.933) while soil total porosity showed the largest range of spatial correlation (A = 43.92 m). The bivariate geostatistical analysis also rendered significant cross-semivariance between different paired soil properties. However, four different semivariogram models were required in that case. This indicates an underlying co-regionalization between different soil properties, which is of interest for delineating management zones within sugarcane fields. Cross-semivariograms showed larger correlation ranges than individual, univariate, semivariograms (A ≥ 29 m). All the findings were supported by multivariate spatial analysis, which showed the influence of soil tillage operations, harvesting machinery and irrigation water distribution on the status of the investigated area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to achieve total selectivity at electrical distribution networks it is of great importance to analyze the defect currents at ungrounded power systems. This information will help to grant selectivity at electrical distribution networks ensuring that only the defect line or feeder is removed from service. In the present work a new selective and directional protection method for ungrounded power systems is evaluated. The new method measures only defect currents to detect earth faults and works with a directional criterion to determine the line under faulty conditions. The main contribution of this new technique is that it can detect earth faults in outgoing lines at any type of substation avoiding the possible mismatch of traditional directional earth fault relays. This detection technique is based on the comparison of the direction of a reference current to the direction of all earth fault capacitive currents at all the feeders connected to the same bus bars. This new method has been validated through computer simulations. The results for the different cases studied are remarkable, proving total validity and usefulness of the new method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Esta tesis que tiene por título "Contribución a los arrays de antenas activos en banda X", ha sido desarrollada por el estudiante de doctorado Gonzalo Expósito Domínguez, ingeniero de telecomunicación en el Grupo de Radiación del Departamento de Señales, Sistemas y Radiocomunicaciones de la ETSI de Telecomunicación de la Universidad Politécnica de Madrid bajo la dirección de los doctores Manuel Sierra Castañer y José Manuel Fernández González. Esta tesis contiene un profundo estudio del arte en materia de antenas activas en el campo de apuntamiento electrónico. Este estudio comprende desde los fundamentos de este tipo de antenas, problemas de operación y limitaciones hasta los sistemas actuales más avanzados. En ella se identifican las partes críticas en el diseño y posteriormente se llevan a la práctica con el diseño, simulación y construcción de un subarray de una antena integrada en el fuselaje de un avión para comunicaciones multimedia por satélite que funciona en banda X. El prototipo consta de una red de distribución multihaz de banda ancha y una antena planar. El objetivo de esta tesis es el de aplicar nuevas técnicas al diseño de antenas de apuntamiento electrónico. Es por eso que las contribuciones originales son la aplicación de barreras electromagnéticas entre elementos radiantes para reducir los acoplamientos mutuos en arrays de exploración electrónica y el diseño de redes desfasadoras sencillas en las que no son necesarios complejos desfasadores para antenas multihaz. Hasta la fecha, las barreras electromagnéticas, Electronic Band Gap (EBG), se construyen en sustratos de permitividad alta con el fin de aumentar el espacio disponible entre elementos radiantes y reducir el tamaño de estas estructuras. Sin embargo, la utilización de sustratos de alta permitividad aumenta la propagación por ondas de superficie y con ellas el acoplo mutuo. Utilizando sustratos multicapa y colocando la vía de las estructuras en su borde, en vez de en su centro, se consigue reducir el tamaño sin necesidad de usar sustratos de alta permitividad, reducir la eficiencia de radiación de la antena o aumentar la propagación por ondas de superficie. La última parte de la tesis se dedica a las redes conmutadoras y desfasadoras para antenas multihaz. El diseño de las redes de distribución para antenas son una parte crítica ya que se comportan como un atenuador a la entrada de la cadena receptora, modificando en gran medida la figura de ruido del sistema. Las pérdidas de un desfasador digital varían con el desfase introducido, por ese motivo es necesario caracterizar y calibrar los dispositivos correctamente. Los trabajos presentados en este manuscrito constan de un desfasador reflectivo con un conmutador doble serie paralelo para igualar las pérdidas de inserción en los dos estados y también un conmutador de una entrada y dos salidas cuyos puertos están adaptados en todo momento independientemente del camino del conmutador para evitar las reflexiones y fugas entre redes o elementos radiantes. El tomo finaliza con un resumen de las publicaciones en revistas científicas y ponencias en congresos, nacionales e internacionales, el marco de trabajo en el que se ha desarrollado, las colaboraciones que se han realizado y las líneas de investigación futuras. ABSTRACT This thesis was carried out in the Radiation Group of the Signals, Systems and Radiocomunications department of ETSI de Telecomunicación from Technical University of Madrid. Its title is "Contribution to active array antennas at X band" and it is developed by Gonzalo Expósito Domínguez, Electrical Engineer MsC. under the supervision of Prof. Dr. Manuel Sierra Castañer and Dr. José Manuel Fernández González. This thesis is focused on active antennas, specifically multibeam and electronic steering antenas. In the first part of the thesis a thorough description of the state of the art is presented. This study compiles the fundamentals of this antennas, operation problems and limits, up to the breakthrough applications. The critical design problems are described to use them eventually in the design, simulation and prototyping of an airborne steering array antenna for satellite communication at X band. The main objective of this thesis is to apply new techniques to the design of electronically steering antennas. Therefore the new original contributions are the application of Electromagnetic Band Gap materials (EBG) between radiating elements to reduce the mutual coupling when phase shift between elements exist and phase shifting networks where special characteristics are required. So far, the EBG structures have been constructed with high permitivity substrates in order to increase the available space between radiating elements and reduce the size of the structures. However, the surface wave propagation modes are enhanced and therefore the mutual coupling increases when high permitivity substrates are used. By using multilayered substrates and edge location via, the size is reduced meanwhile low permitivity substrates are used without reducing the radiation efficiency or enhancing the surface propagation modes. The last part of the thesis is focused on the phase shifting distribution networks for multibeam antennas. This is a critical part in the antenna design because the insertion loss in the distribution network behaves as an attenuator located in the first place in a receiver chain. The insertion loss will affect directly to the receiver noise figure and the insertion loss in a phase shifter vary with the phase shift. Therefore the devices must be well characterized and calibrated in order to obtain a properly operation. The work developed in this thesis are a reflective phase shifter with a series-shunt switch in order to make symmetrical the insertion loss for the two states and a complex Single Pole Double Through (SPDT) with matched ports in order to reduce the reflections and leakage between feeding networks and radiating elements. The end of this Ph D. dissertation concludes with a summary of the publications in national and international conferences and scientific journals, the collaborations carried out along the thesis and the future research lines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a novel self-timed multi-purpose sensor especially conceived for Field Programmable Gate Arrays (FPGAs). The aim of the sensor is to measure performance variations during the life-cycle of the device, such as process variability, critical path timing and temperature variations. The proposed topology, through the use of both combinational and sequential FPGA elements, amplifies the time of a signal traversing a delay chain to produce a pulse whose width is the sensor’s measurement. The sensor is fully self-timed, avoiding the need for clock distribution networks and eliminating the limitations imposed by the system clock. One single off- or on-chip time-to-digital converter is able to perform digitization of several sensors in a single operation. These features allow for a simplified approach for designers wanting to intertwine a multi-purpose sensor network with their application logic. Employed as a temperature sensor, it has been measured to have an error of ±0.67 °C, over the range of 20–100 °C, employing 20 logic elements with a 2-point calibration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El agua de riego en España se ha reducido del 80 % al 70% tras la rehabilitación de los sistemas tradicionales de riego y el incremento de riegos a presión. La política española ha favorecido la creación de nuevos regadíos con fines sociales, para asentar a la población rural en zonas con disponibilidad de recursos hídricos. Este contexto es aplicable a la Comunidad de Regantes “Rio Adaja” (CCRR), que comenzó a funcionar en 2010 por lo que se la ha elegido para evaluar el uso y productividad del agua y manejo del riego en CCRR modernizadas de la cuenca del Duero. El estudio del manejo del riego se realizó con evaluaciones de campo, el primer año de funcionamiento, en una muestra de sistemas de riego (pivotes centrales, ramales de avance frontal, cobertura total) representativa de los sistemas predominantes en la CCRR. Además, se analizó la carta de riego propuesta por el fabricante de los pivotes centrales, considerando una distribución de caudal continua a lo largo del ramal, y se propuso una nueva carta con emisores de riego que mejoraban la uniformidad de aplicación del agua. El uso del agua en la CCRR se evaluó considerando tanto los indicadores de eficiencia del riego: suministro relativo de riego (anual relative irrigation supply, ARIS), suministro relativo del agua (anual relativewater supply, ARWS), suministro relativo de precipitación (rainfall relative supply, RRS) como los de productividad: productividad del agua (water productivity, WP) productividad del agua de riego (irrigation water productivity, IWP) y productividad de la evapotranspiración (evapotranspiration water productivity, ETWP). Primero, se determinaron: las necesidades hídricas de los cultivos para mantener un contenido de humedad óptimo en su zona radical, el coeficiente dual del cultivo, el agua disponible total (ADP) y agua fácilmente aprovechable (AFA). Después, se estimaron las necesidades hídricas de los cultivos considerando tres años tipo: húmedo, normal y seco correspondientes a la probabilidad de disponibilidad de la precipitación del 20, 50 y 80%, respectivamente. Así mismo, se realizó una encuesta a los regantes de la CCRR para conocer la dosis de riego y rendimiento anual de los cultivos principales durante sus tres años de funcionamiento: 2010-2011, 2011-2012 y 2012-2013.Finalmente, se simuló el efecto del riego y su manejo en la producción de los cultivos y en la productividad del agua. Además, el modelo de simulación AQUACROP (Geerts et al., 2010) se ha utilizado para estudiar la mejora del uso del agua de los cultivos de la CCRR. Dado que este modelo requiere de calibración específica para cada cultivo y cada zona y dado que, de todos los cultivos de la CCRR, sólo el girasol cumplía el requisito, este cultivo fue elegido para estudiar si la estrategia de riego deficitario mejoraría el uso del agua. Los resultados obtenidos indican que el 90% de los sistemas de riego evaluados distribuye el agua con una uniformidad adecuada (CUC≥75%). La simulación de la distribución del agua con las cartas de riego propuestas por el fabricante en pivotes centrales resultó en coeficientes CUC< 75% y sus valores mejoraban al eliminar el aspersor distal. La uniformidad del riego mejoraría si se trabajase con la carta de riego propuesta y que se compone por emisores de riego seleccionados en este estudio. En la mayoría de los cultivos, se aplicó riegos deficitarios (ARIS < 1 en los dos primeros años de funcionamiento de la CCRR y riegos excedentarios (ARIS > 1) el tercer año siendo significativas las diferencias observadas. El manejo del riego fue bueno (0,9 ≤ ARWS ≤1,2) en la mayoría de los cultivos. Así mismo, los indicadores de productividad del agua (WP e IWP (€.m-3)) varió entre cultivos y años estudiados y, destacan los valores observados en: cebolla, patata, zanahoria y cebada. En general, la productividad del agua en los riegos deficitarios fue mayor observándose además, que los índices de productividad mayores correspondieron al año con precipitación mayor aunque, las diferencias entre sus valores medios no fueron significativas en las tres campañas de riego estudiadas. Los resultados apuntan a que la metodología del balance hídrico y las herramientas presentadas en este trabajo (uniformidad de distribución de agua, indicadores de eficiencia del uso de agua y de su productividad) son adecuadas para estudiar el manejo del agua en CCRR. En concreto, la uniformidad en la aplicación del agua de la CCRR mejoraría seleccionando emisores de riego que proporcionen una mayor uniformidad de distribución del agua, lo que conllevaría a cambiar el diámetro de la boquilla de los emisores y/o eliminar el aspersor distal. Así mismo, puede ser de interés adoptar estrategias de riego deficitario para incrementar la productividad en el uso del agua, y las rentas de los regantes, para lo cual se propone utilizar un patrón de cultivos de referencia. Finalmente, el riego deficitario puede ser una estrategia para mejorar la eficiencia y productividad en el uso del agua de la CCRR siempre que lleve asociado un manejo del riego adecuado que resulta, relativamente, más fácil cuando se dispone de sistemas de riego con una uniformidad de aplicación alta. Sin embargo su aplicación no sería aconsejable en los cultivos de remolacha azucarera, regado con sistemas de riego con un coeficiente de uniformidad de Christiansen CUC < 75%, y maíz, regado con sistemas de riego con un coeficiente de uniformidad de Christiansen CUC < 65%. ABSTRACT The irrigation scheme modernization and the increase of sprinkler irrigation area have reduced the irrigation water use from 80 to 70%. The national irrigation policy favored the creation of new irrigation schemes with the purpose to settle the rural population in areas with availability in water resources. Within this context, the irrigation district “Río Adaja” (CCRR) started in 2010 so, it has been chosen as a case study to evaluate the water use and the irrigation management in a modernized CCRR. Several field evaluations were carried out during the first operation year, in a sample of irrigation systems (center pivot, moving lateral and solid set) selected among all the systems in the CCRR. Likewise, the manufacturer irrigation chart for the center pivot systems has been considered and the pressure and discharge distribution along the pivot have been estimated, assuming a continuous flow along the pipe. Then; the sprinkler nozzles were selected order to increase the uniformity on water application. The water use in the CCRR has been assessed by considering the water use efficiency indicators: annual relative irrigation supply (ARIS), annual relative water supply (ARWS), relative rainfall supply (RRS) and also the productivity indicators: water productivity (WP), irrigation water productivity (IWP) and evapotranspiration water productivity (ETWP). On the one hand, it has been determined the crop water requirement (to maintain the optimal soil water content in the rooting zone), the dual crop coefficient, the total available water and the readily available water. The crop water requirement was estimated by considering the typical wet, normal and dry years which correspond to the probability of effective precipitation exceedance of 20, 50 and 80%, respectively. On the other hand, the irrigation depth and crop yield by irrigation campaign have been considered for the main crops in the area. This information was obtained from a farmer’s survey in 2010-2011, 2011-2012 and 2012-2013. For sunflower, the irrigation effect and its management on the crop yield and water productivity have been simulated. Also a deficit irrigation strategy, which improves the water resources, has been determined by means of AQUACROP (FAO). The results showed that 90% of the evaluated irrigation systems have adequate irrigation water application uniformity (CUC ≥ 75%). The CUC values in center pivots, which were calculated using the manufacturer irrigation chart, are below < 75% . However, these values would increase with the change of emitter nozzle to the proposed nozzles selection. The results on water use showed a deficit irrigation management (ARIS < 1), in most of crops during the first two operation years, and an excess in irrigation for the third year (ARIS > 1) although non-significant difference was observed. In most cases, the management of irrigation is adequate (0,9≤ ARWS≤ 1,2) although there are differences among crops. Likewise, the productivity indicators (WP and IWP (€.m-3)) varied among crops and with irrigation events. The highest values corresponded to onion, potato, carrot and barley. The values for deficit irrigation were the highest and the productivity indicators increased the year with the highest effective precipitation. Nevertheless, the differences between the average values of these indicators by irrigation campaign were non-significant. This study highlights that the soil water balance methodology and other tools used in the methodology are adequate to study the use and productivity of water in the irrigation district. In fact, the water use in this CCRR can be improved if the irrigation systems were designed with higher water distribution uniformity what would require the change of sprinkler nozzles and/or eliminate the end gun. Likewise, it is advisable to set up deficit irrigation strategies to increase the water productivity taking into account certain limits on water application uniformities. In this respect, a reference cropping pattern has been proposed and the limits for water uniformity have been calculated for several crops.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The more and more demanding conditions in the power generation sector requires to apply all the available technologies to optimize processes and reduce costs. An integrated asset management strategy, combining technical analysis and operation and maintenance management can help to improve plant performance, flexibility and reliability. In order to deploy such a model it is necessary to combine plant data and specific equipment condition information, with different systems devoted to analyze performance and equipment condition, and take advantage of the results to support operation and maintenance decisions. This model that has been dealt in certain detail for electricity transmission and distribution networks, is not yet broadly extended in the power generation sector, as proposed in this study for the case of a combined power plant. Its application would turn in direct benefit for the operation and maintenance and for the interaction to the energy market