5 resultados para Fault line
em Universidad Politécnica de Madrid
Resumo:
The development of this Master's Thesis is aimed at modeling active for estimating seismic hazard in Haití failures. It has been used zoned probabilistic method, both classical and hybrid, considering the incorporation of active faults as independent units in the calculation of seismic hazard. In this case, the rate of seismic moment is divided between the failures and the area seismogenetic same region. Failures included in this study are the Septentrional, Matheux and Enriquillo fault. We compared the results obtained by both methods to determine the importance of considering the faults in the calculation. In the first instance, updating the seismic catalog, homogenization, completeness analysis and purification was necessary to obtain a catalog ready to proceed to the estimation of the hazard. With the seismogenic zoning defined in previous studies and the updated seismic catalog, they are obtained relations Gutenberg-Richter recurrence of seismicity, superficial and deep in each area. Selected attenuation models were those used in (Benito et al., 2011), as the tectonic area of study is very similar to that of Central America. Its implementation has been through the development of a logical in which each branch is multiplied by an index based on the relevance of each combination of models. Results are presented as seismic hazard maps for return periods of 475, 975 and 2475 years, and spectral acceleration (SA) in structural periods: 0.1 - 0.2 - 0.5 - 1.0 and 2.0 seconds, and the difference accelerations between maps obtained by the classical method and the hybrid method. Maps realize the importance of including faults as separate items in the calculation of the hazard. The morphology of the zoned maps presented higher values in the area where the superficial and deep zone overlap. In the results it can determine that the minimum values in the zoned approach they outweigh the hybrid method, especially in areas where there are no faults. Higher values correspond to those obtained in fault zones by the hybrid method understanding that the contribution of the faults in this method is very important with high values. The maximum value of PGA obtained is close to Septentrional in 963gal, near to 460 gal in Matheux, and the Enriquillo fault line value reaches 760gal PGA in the Eastern segment and Western 730gal in the segment. This compares with that obtained in the zoned approach in this area where the value of PGA obtained was 240gal. These values are compared with those obtained by Frankel et al., (2011) with those have much similarity in values and morphology, in contrast to those presented by Benito et al., (2012) and the Standard Seismic Dominican Republic
New On-Line Excitation-System Ground Fault Location Method Tested in a 106 MVA Synchronous Generator
Resumo:
In this paper, a novel excitation-system ground-fault location method is described and tested in a 106 MVA synchronous machine. In this unit, numerous rotor ground-fault trips took place always about an hour after the synchronization to the network. However, when the field winding insulation was checked after the trips, there was no failure. The data indicated that the faults in the rotor were caused by centrifugal forces and temperature. Unexpectedly, by applying this new method, the failure was located in a cable between the excitation transformer and the automatic voltage regulator. In addition, several intentional ground faults were performed along the field winding with different fault resistance values, in order to test the accuracy of this method to locate defects in rotor windings of large generators. Therefore, this new on-line rotor ground-fault detection algorithm is tested in high-power synchronous generators with satisfactory results.
Resumo:
A good and early fault detection and isolation system along with efficient alarm management and fine sensor validation systems are very important in today¿s complex process plants, specially in terms of safety enhancement and costs reduction. This paper presents a methodology for fault characterization. This is a self-learning approach developed in two phases. An initial, learning phase, where the simulation of process units, without and with different faults, will let the system (in an automated way) to detect the key variables that characterize the faults. This will be used in a second (on line) phase, where these key variables will be monitored in order to diagnose possible faults. Using this scheme the faults will be diagnosed and isolated in an early stage where the fault still has not turned into a failure.
Resumo:
In this paper a new method for fault isolation in a class of continuous-time stochastic dynamical systems is proposed. The method is framed in the context of model-based analytical redundancy, consisting in the generation of a residual signal by means of a diagnostic observer, for its posterior analysis. Once a fault has been detected, and assuming some basic a priori knowledge about the set of possible failures in the plant, the isolation task is then formulated as a type of on-line statistical classification problem. The proposed isolation scheme employs in parallel different hypotheses tests on a statistic of the residual signal, one test for each possible fault. This isolation method is characterized by deriving for the unidimensional case, a sufficient isolability condition as well as an upperbound of the probability of missed isolation. Simulation examples illustrate the applicability of the proposed scheme.
Resumo:
This paper presents a new selective and non-directional protection method to detect ground faults in neutral isolated power systems. The new proposed method is based on the comparison of the rms value of the residual current of all the lines connected to a bus, and it is able to determine the line with ground defect. Additionally, this method can be used for the protection of secondary substation. This protection method avoids the unwanted trips produced by wrong settings or wiring errors, which sometimes occur in the existing directional ground fault protections. This new method has been validated through computer simulations and experimental laboratory tests.