980 resultados para solid-phase microextraction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, sensitive, and accurate method for determination of polybrominated diphenyl ethers (PBDEs) in soil has been developed based on headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS). Permethylated-beta-cyclodextrin/hydroxyl-termination silicone oil (PM-beta-CD/OH-TSO) fiber was first prepared by sol-gel technology and employed in SPME procedure. By exploiting the superiorities of sot-gel coating technique and the advantages of the high hydrophobic doughnut-shaped cavity of PM-beta-CD, the novel fiber showed desirable operational stability and extraction ability. After optimization on extraction conditions like water addition, extraction temperature, extraction time, salts effect, and solvents addition, the method was validated in soil samples, achieving good linearity (r>0.999), precision (R.S.D. < 10%), accuracy (recovery>78%), and detection limits (S/N =3) raging from 13.0 to 78.3 pg/g. (c) 2007 Published by Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid and sensitive on-line method for simultaneous determination of four endocrine disruptors (17 beta-estradiol, estriol, bisphenol A and 17 alpha-ethinylestradiol) in environmental waters was developed by coupling in-tube solid-phase microextraction (SPME) to high-performance liquid chromatography (HPLC) with fluorescence detection (FLD). A poly(acrylamide-vinylpyridine-NAP-methylene bisacrylamide) monolith, synthesized inside a polyether ether ketone (PEEK) tube, was selected as the extraction medium. To achieve optimum extraction performance, several parameters were investigated, including extraction flow-rate, extraction time, and pH value, inorganic salt and organic solvent content of the sample matrix. By simply filtered with nylon membrane filter and adjusting the pH of samples to 6.0 with phosphoric acid, the sample solution then could be directly injected into the device for extraction. Low detection limits (S/N = 3) and quantification limits (S/N = 10) of the proposed method were achieved in the range of 0.006-0.10 ng/mL and 0.02-0.35 ng/mL from spiked lake waters, respectively. The calibration curves of four endocrine disruptors showed good linearity ranging from quantification limits to 50 ng/mL with a linear coefficient R-2 value above 0.9913. Good method reproducibility was also found by intra- and inter-day precisions, yielding the RSDs less than 12 and 9.8%, respectively. Finally, the proposed method was successfully applied to the determination of these compounds in several environmental waters. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel fiber coated with novel sol-gel (5,11,17,23-tetra-tert-butyl-25,27-dihydroxy-26,28-diglycidyloxycalix[4]arene/hydroxy-terminated silicone oil; diglycidyloxy-C[4]/OH-TSO) was prepared for use with headspace solid-phase microextraction (HS-SPME) combined with gas chromatography (GC) and electron capture detection (ECD), which was applied in order to determine nine chlorobenzenes in soil matrices. Due to the improved fiber preparation, which increases the percentage of calixarene in the coating, the new calixarene fiber exhibits very high extraction selectivity and sensitivity to chlorine-substituted compounds. Various parameters affecting the extraction efficiency were optimized in order to maximize the sensitivity during the chlorobenzene analysis. Interferences from different soil matrices with different characteristics were investigated, and the amount extracted was strongly influenced by the matrix. Therefore, a standard addition protocol was performed on the real soil samples. The linear ranges of detection for the chlorobenzenes tested covered three orders of magnitude, and correlation coefficients > 0.9976 and relative standard deviations (RSD) < 8% were observed. The detection limits were found at sub-ng/g of soil levels, which were about an order of magnitude lower than those given by the commercial poly(dimethylsiloxane) (PDMS) coating for most of the compounds. The recoveries ranged from 64 to 109.6% for each analyte in the real kaleyard soil matrix when different concentration levels were determined over the linear range, which confirmed the reliability and feasibility of the HS-SPME/GC-ECD approach using the fiber coated with diglycidyloxy-C[4]/OH-TSO for the ultratrace analysis of chlorobenzenes in complex matrices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three major odorous compounds are 2-methylisoborneol ( 2-MIB), geosmin and beta-cyclocitral, which in water were determined by coupling headspace solid-phase microextraction ( HS-SPME) with gas chromatography-mass spectrometry (GC-MS). The operating conditions of HS-SPME, such as fibre type, salt concentration, water temperature, stirring, absorption time and desorption time were studied and discussed.The highest absorption of the odorous compounds were obtained under the following operating conditions as the addition of 30% ( m/V) NaCl, stirring at 60 degrees C for 40 min, using 65 mu m polydimethyl siloxane/divinylbenzene coated fibre. After the odorous compounds had been absorbed in the fibre under the optimal conditions of HSSPME, they were desorbed at 250 degrees C and determined by GC-MS. The limits of detection for geosmin, beta-cyclocitral and 2-MIB in water were 1. 0, 1. 3, 1. 7 ng/L, and the relative standard deviations for them were 4. 9%, 8. 4%, 6. 2%,respectively. There were good linear correlation (the calibration coefficients were all above 0. 997) for the three odorous compounds in the range of 5 similar to 1000 ng/ L. Therefore, trace levels of the odorous compounds at ng/L in water could be quantified by the simple method with satisfactory result.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ultrasonic solvent extraction combined with solid-phase microextraction (SPME) with calix[4]arene/hydroxy-terminated silicone (C[4]/OHTSO) oil coated fiber was used to extract phthalate acid esters (PAEs) plasticizers in plastic, such as blood bags, transfusion tubing, food packaging bag, and mineral water bottle for analysis by gas chromatography (GC). Both extraction parameters (i.e. extraction time, extraction temperature, ionic strength) and conditions of the thermal desorption in a GC injector were optimized by analysis of eight phthalates. The fiber shows wonderful sensitivity and selectivity to the tested compounds. Owing to its high thermal stability (380 degreesC), the carryover effect that often encountered when using conventional fibers can be reduced by appropriately enhancing the injector temperature. The method showed linear response over two to four orders of magnitude with correlation coefficients (r) better than 0.996, and limits of detection (LOD) ranged between 0.006 and 0.084 mug l(-1). The relative standard deviation values obtained were less than or equal to 10%. bis-2-Ethylhexyl phthalate (DEHP) was the sole analyte detected in these plastics and recoveries were in the ranges 95.5-101.4% in all the samples. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, both,solid phase microextraction (SPME) and solid phase extraction(SPE) were used to enrich organochlorine compounds in water samples and analyzed by gas chromatography with electron capture detector. The operating conditions of SPME have been studied and different kinds of solid phase were compared. Linear alkybenzene sulfonate(LAS) was added to the samples to investigate its effect on the analysis. The results indicated that polyacrylate was better than other commercial solid phases in extraction of moderated polar organic compounds and the sensitivity of SPME was higher than SPE. LAS affect much in liquid-liquid extraction and headspace SPME; but it has little effect on SPE and direct-SPME method. The applications showed that SPME was a fast and effective method in sample preparation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel sol-gel method is applied for the preparation of solid-phase microextraction (SPME) fibers. Scanning electron microscopy experiments suggested a porous structure for the poly(dimethylsiloxane) (PDMS) coating. SPME-GC analysis provided evidence that the sol-gel fibers have some advantages, such as high thermal stability, efficient extraction rates, high velocities of mass transfer, and spacious range of application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The contour lithography method [1] is used to improve the fabrication yield of previously demonstrated [2] microfluidic Fabry-Perot (FP) refractive index (RI) sensors. The sensors are then coated with polydimethylsiloxane (PDMS) based polymers to detect vapor analytes by solid-phase microextraction (SPME). Preliminary characterization of devices coated with two different polymers and exposed to xylenes vapors yields a maximum sensitivity of 0.015 nm/ppm and a detection limit below 120 ppm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A multiresidue gas chromatographic method for the determination of six fungicides (captan, chlorthalonil, folpet, iprodione, procymidone and vinclozolin) and one acaricide (dicofol) in still and fortified wines was developed. Solid-phase microextraction (SPME) was chosen for the extraction of the compounds from the studied matrices and tandem mass spectrometry (MS/MS) detection was used. The extraction consists in a solvent free and automated procedure and the detection is highly sensitive and selective. Good linearity was obtained with correlation coefficients of regression (R2) > 0.99 for all the compounds. Satisfactory results of repeatability and intermediate precision were obtained for most of the analytes (RSD < 20%). Recoveries from spiked wine ranged from 80.1% to 112.0%. Limits of quantification (LOQs) were considerably below the proposedmaximumresidue limits (MRLs) for these compounds in grapes and below the suggested limits for wine (MRLs/10), with the exception of captan.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.