11 resultados para capillary electrophoresis

em Helda - Digital Repository of University of Helsinki


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Miniaturization of analytical instrumentation is attracting growing interest in response to the explosive demand for rapid, yet sensitive analytical methods and low-cost, highly automated instruments for pharmaceutical and bioanalyses and environmental monitoring. Microfabrication technology in particular, has enabled fabrication of low-cost microdevices with a high degree of integrated functions, such as sample preparation, chemical reaction, separation, and detection, on a single microchip. These miniaturized total chemical analysis systems (microTAS or lab-on-a-chip) can also be arrayed for parallel analyses in order to accelerate the sample throughput. Other motivations include reduced sample consumption and waste production as well as increased speed of analysis. One of the most promising hyphenated techniques in analytical chemistry is the combination of a microfluidic separation chip and mass spectrometer (MS). In this work, the emerging polymer microfabrication techniques, ultraviolet lithography in particular, were exploited to develop a capillary electrophoresis (CE) separation chip which incorporates a monolithically integrated electrospray ionization (ESI) emitter for efficient coupling with MS. An epoxy photoresist SU-8 was adopted as structural material and characterized with respect to its physicochemical properties relevant to chip-based CE and ESI/MS, namely surface charge, surface interactions, heat transfer, and solvent compatibility. As a result, SU-8 was found to be a favorable material to substitute for the more commonly used glass and silicon in microfluidic applications. In addition, an infrared (IR) thermography was introduced as direct, non-intrusive method to examine the heat transfer and thermal gradients during microchip-CE. The IR data was validated through numerical modeling. The analytical performance of SU-8-based microchips was established for qualitative and quantitative CE-ESI/MS analysis of small drug compounds, peptides, and proteins. The CE separation efficiency was found to be similar to that of commercial glass microchips and conventional CE systems. Typical analysis times were only 30-90 s per sample indicating feasibility for high-throughput analysis. Moreover, a mass detection limit at the low-attomole level, as low as 10E+5 molecules, was achieved utilizing MS detection. The SU-8 microchips developed in this work could also be mass produced at low cost and with nearly identical performance from chip to chip. Until this work, the attempts to combine CE separation with ESI in a chip-based system, amenable to batch fabrication and capable of high, reproducible analytical performance, have not been successful. Thus, the CE-ESI chip developed in this work is a substantial step toward lab-on-a-chip technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of a simple method of coating a semi-permanent phospholipid layer onto a capillary for electrochromatography use was the focus of this study. The work involved finding good coating conditions, stabilizing the phospholipid coating, and examining the effect of adding divalent cations, cetyltrimethylammonium bromide, and polyethylene glycol (PEG)-lipids on the stability of the coating. Since a further purpose was to move toward more biological membrane coatings, the capillaries were also coated with cholesterol-containing liposomes and liposomes of red blood cell ghost lipids. Liposomes were prepared by extrusion, and large unilamellar vesicles with a diameter of about 100 nm were obtained. Zwitterionic phosphatidylcholine (PC) was used as a basic component, mainly 1-palmitoyl-2-oleyl-sn-glycero-3-phosphocholine (POPC) but also eggPC and 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC). Different amounts of sphingomyelin, bovine brain phosphatidylserine, and cholesterol were added to the PC. The stability of the coating in 40 mM N-(2-hydroxyethyl)piperazine-N’-(2-ethanesulfonic acid) (HEPES) solution at pH 7.4 was studied by measuring the electroosmotic flow and by separating neutral steroids, basic proteins, and low-molar-mass drugs. The presence of PC in the coating solution was found to be essential to achieving a coating. The stability of the coating was improved by the addition of negative phosphatidylserine, cholesterol, divalent cations, or PEGylated lipids, and by working in the gel-state region of the phospholipid. Study of the effect on the PC coating of divalent metal ions calcium, magnesium, and zinc showed a molar ratio of 1:3 PC/Ca2+ or PC/Mg2+ to give increased rigidity to the membrane and the best coating stability. The PEGylated lipids used in the study were sterically stabilized commercial lipids with covalently attached PEG chains. The vesicle size generally decreased when PEGylated lipids of higher molar mass were present in the vesicle. The predominance of discoidal micelles over liposomes increased PEG chain length and the average size of the vesicles thus decreased. In the capillary electrophoresis (CE) measurements a highly stable electroosmotic flow was achieved with 20% PEGylated lipid in the POPC coating dispersion, the best results being obtained for disteroyl PEG (3000) conjugates. The results suggest that smaller particles (discoidal micelles) result in tighter packing and better shielding of silanol groups on the silica wall. The effect of temperature on the coating stability was investigated by using DPPC liposomes at temperatures above (45 C) and below (25 C) the main phase transition temperature. Better results were obtained with DPPC in the more rigid gel state than in the fluid state: the electroosmotic flow was heavily suppressed and the PC coating was stabilized. Also dispersions of DPPC with 0−30 mol% of cholesterol and sphingomyelin in different ratios, which more closely resemble natural membranes, resulted in stable coatings. Finally, the CE measurements revealed that a stable coating is formed when capillaries are coated with liposomes of red blood cell ghost lipids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foreign compounds, such as drugs are metabolised in the body in numerous reactions. Metabolic reactions are divided into phase I (functionalisation) and phase II (conjugation) reactions. Uridine diphosphoglucuronosyltransferase enzymes (UGTs) are important catalysts of phase II metabolic system. They catalyse the transfer of glucuronic acid to small lipophilic molecules and convert them to hydrophilic and polar glucuronides that are readily excreted from the body. Liver is the main site of drug metabolism. Many drugs are racemic mixtures of two enantiomers. Glucuronidation of a racemic compound yields a pair of diastereomeric glucuronides. Stereoisomers are interesting substrates in glucuronidation studies since some UGTs display stereoselectivity. Diastereomeric glucuronides of O-desmethyltramadol (M1) and entacapone were selected as model compounds in this work. The investigations of the thesis deal with enzymatic glucuronidation and the development of analytical methods for drug metabolites, particularly diastereomeric glucuronides. The glucuronides were analysed from complex biological matrices, such as urine or from in vitro incubation matrices. Various pretreatment techniques were needed to purify, concentrate and isolate the analytes of interest. Analyses were carried out by liquid chromatography (LC) with ultraviolet (UV) or mass spectrometric (MS) detection or with capillary electromigration techniques. Commercial glucuronide standards were not available for the studies. Enzyme-assisted synthesis with rat liver microsomes was therefore used to produce M1 glucuronides as reference compounds. The glucuronides were isolated by LC/UV and ultra performance liquid chromatography (UPLC)/MS, while tandem mass spectrometry (MS/MS) and nuclear magnetic resonance (NMR) spectroscopy were employed in structural characterisation. The glucuronides were identified as phenolic O-glucuronides of M1. To identify the active UGT enzymes in (±)-M1 glucuronidation recombinant human UGTs and human tissue microsomes were incubated with (±)-M1. The study revealed that several UGTs can catalyse (±)-M1 glucuronidation. Glucuronidation in human liver microsomes like in rat liver microsomes is stereoselective. The results of the studies showed that UGT2B7, most probably, is the main UGT responsible for (±)-M1 glucuronidation in human liver. Large variation in stereoselectivity of UGTs toward (±)-M1 enantiomers was observed. Formation of M1 glucuronides was monitored with a fast and selective UPLC/MS method. Capillary electromigration techniques are known for their high resolution power. A method that relied on capillary electrophoresis (CE) with UV detection was developed for the separation of tramadol and its free and glucuronidated metabolites. The suitability of the method to identify tramadol metabolites in an authentic urine samples was tested. Unaltered tramadol and four of its main metabolites were detected in the electropherogram. A micellar electrokinetic chromatography (MEKC) /UV method was developed for the separation of the glucuronides of entacapone in human urine. The validated method was tested in the analysis of urine samples of patients. The glucuronides of entacapone could be quantified after oral entacapone dosing.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Determination of testosterone and related compounds in body fluids is of utmost importance in doping control and the diagnosis of many diseases. Capillary electromigration techniques are a relatively new approach for steroid research. Owing to their electrical neutrality, however, separation of steroids by capillary electromigration techniques requires the use of charged electrolyte additives that interact with the steroids either specifically or non-specifically. The analysis of testosterone and related steroids by non-specific micellar electrokinetic chromatography (MEKC) was investigated in this study. The partial filling (PF) technique was employed, being suitable for detection by both ultraviolet spectrophotometry (UV) and electrospray ionization mass spectrometry (ESI-MS). Efficient, quantitative PF-MEKC UV methods for steroid standards were developed through the use of optimized pseudostationary phases comprising surfactants and cyclodextrins. PF-MEKC UV proved to be a more sensitive, efficient and repeatable method for the steroids than PF-MEKC ESI-MS. It was discovered that in PF-MEKC analyses of electrically neutral steroids, ESI-MS interfacing sets significant limitations not only on the chemistry affecting the ionization and detection processes, but also on the separation. The new PF-MEKC UV method was successfully employed in the determination of testosterone in male urine samples after microscale immunoaffinity solid-phase extraction (IA-SPE). The IA-SPE method, relying on specific interactions between testosterone and a recombinant anti-testosterone Fab fragment, is the first such method described for testosterone. Finally, new data for interactions between steroids and human and bovine serum albumins were obtained through the use of affinity capillary electrophoresis. A new algorithm for the calculation of association constants between proteins and neutral ligands is introduced.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The structures of (1→3),(1→4)-β-D-glucans of oat bran, whole-grain oats and barley and processed foods were analysed. Various methods of hydrolysis of β-glucan, the content of insoluble fibre of whole grains of oats and barley and the solution behaviour of oat and barley β-glucans were studied. The isolated soluble β-glucans of oat bran and whole-grain oats and barley were hydrolysed with lichenase, an enzyme specific for (1→3),(1→4)-β-D-β-glucans. The amounts of oligosaccharides produced from bran were analysed with capillary electrophoresis and those from whole-grains with high-performance anion-exchange chromatography with pulse-amperometric detection. The main products were 3-O-β-cellobiosyl-D-glucose and 3-O-β-cellotriosyl-D-glucose, the oligosaccharides which have a degree of polymerisation denoted by DP3 and DP4. Small differences were detected between soluble and insoluble β-glucans and also between β-glucans of oats and barley. These differences can only be seen in the DP3:DP4 ratio which was higher for barley than for oat and also higher for insoluble than for soluble β-glucan. A greater proportion of barley β-glucan remained insoluble than of oat β-glucan. The molar masses of soluble β-glucans of oats and barley were the same as were those of insoluble β-glucans of oats and barley. To analyse the effects of cooking, baking, fermentation and drying, β-glucan was isolated from porridge, bread and fermentate and also from their starting materials. More β-glucan was released after cooking and less after baking. Drying decreased the extractability for bread and fermentate but increased it for porridge. Different hydrolysis methods of β-glucan were compared. Acid hydrolysis and the modified AOAC method gave similar results. The results of hydrolysis with lichenase gave higher recoveries than the other two. The combination of lichenase hydrolysis and high-performance anion-exchange chromatography with pulse-amperometric detection was found best for the analysis of β-glucan content. The content of insoluble fibre was higher for barley than for oats and the amount of β-glucan in the insoluble fibre fraction was higher for oats than for barley. The flow properties of both water and aqueous cuoxam solutions of oat and barley β-glucans were studied. Shear thinning was stronger for the water solutions of oat β-glucan than for barley β-glucan. In aqueous cuoxam shear thinning was not observed at the same concentration as in water but only with high concentration solutions. Then the viscosity of barley β-glucan was slightly higher than that of oat β-glucan. The oscillatory measurements showed that the crossover point of the G´ and G´´ curves was much lower for barley β-glucan than for oat β-glucan indicating a higher tendency towards solid-like behaviour for barley β-glucan than for oat β-glucan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The von Hippel-lindau (VHL) disease is a dominantly inherited neoplastic disorder which predisposes patients to multiple tumours including capillary haemangioblastomas (CHBs), pheochromocytomas (PCCs), renal cell carcinomas (RCCs). CHBs are the most common manifestations of VHL disease, occurring sporadically or as a manifestation of VHL disease. Inactivation of the VHL gene at 3p25-26 is believed to cause both familial and sporadic VHL-associated tumours and germ-line mutation of the VHL gene have been detected in 100% of the CHBs studied. However, a limited number of sporadic CHBs, PCCs display VHL inactivation. Other molecular alterations involved in tumourigenesis of sporadic CHBs, PCCs remain largely unknown. The purpose of the present work was to search for genetic alterations, or other mechanisms of inactivation, in addition to the VHL gene, that may be important in the development of VHL-associated tumours. Though less satisfactory than cure, prevention and early detection are the most promising and feasible means reducing cancer morbidity and mortality. This work is based on the view that increasing knowledge about the molecular events underlying tumour development will eventually aid in early detection and lead to improved treatment. We evaluated a large set of VHL-associated patients, searched for a clinical and radiologic signs of the disease. We succesfully performed a germ-line mutation analysis and characterised three patient groups, VHL, suspect VHL and sporadic, a germ-line mutation analysis revealed a 50% mutation rate only in the VHL groups, no sporadic or suspect cases displayed any mutation. We also utilized comparative genomic hybridization (CGH) to screen for DNA copy number changes in both sporadic and VHL-associated CHB. Our analysis revealed (27%) DNA copy number losses. The most common finding was loss of chromosomal arm 6q, seen in (23%) cases, No differences were noted between VHL-associated and sporadic tumours. Furthermore a loss of heterozygosity (LOH) study on chromosome 3p and 6q was done with the purpose to determine allele losses not observable by CGH, and to uncover the location of putative tumour suppressor genes important in CHB and PCC tumourigenesis. We identified loss of chromosome 6q and a minimal deleted area at 6q23-24 in CHBs. We also showed LOH at 6q23-24 in PCCs and identified the ZAC1 (6q24-25) as a candidate gene, ZAC1 is a maternally imprinted tumour suppressor gene with anti proliferative properties. To study further the role of ZAC inactivation in CHBs, we investigated LOH, promoter hypermethylation and expression status of the ZAC1 gene in mainly sporadic CHBs. Our LOH analysis revealed that the majority of the tumours with allele loss. The gene promoter methylation analysis similarly detected predominance of the methylated ZAC sequence in almost all tumours. Immunohistochemistry exhibited a strongly reduced expression of ZAC in stromal cells of all CHBs studied. Our current results indicate that the absence of the unmethylated, ZAC1 promoter sequence was highly concurrent with LOH for the ZAC1 region or 6q loss. This observation together with lack of ZAC expression, points to preferential loss of the non imprinted, expressed ZAC allele in CHB, in summary, our series of studies reveal a new chromosomal region 6q, emphasizes the importance of ZAC1 gene in the development of CHB and PCC, particularly in non-VHL associated cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This doctoral thesis describes the development of a miniaturized capillary electrochromatography (CEC) technique suitable for the study of interactions between various nanodomains of biological importance. The particular focus of the study was low-density lipoprotein (LDL) particles and their interaction with components of the extracellular matrix (ECM). LDL transports cholesterol to the tissues through the blood circulation, but when the LDL level becomes too high the particles begin to permeate and accumulate in the arteries. Through binding sites on apolipoprotein B-100 (apoB-100), LDL interacts with components of the ECM, such as proteoglycans (PGs) and collagen, in what is considered the key mechanism in the retention of lipoproteins and onset of atherosclerosis. Hydrolytic enzymes and oxidizing agents in the ECM may later successively degrade the LDL surface. Metabolic diseases such as diabetes may provoke damage of the ECM structure through the non-enzymatic reaction of glucose with collagen. In this work, fused silica capillaries of 50 micrometer i.d. were successfully coated with LDL and collagen, and steroids and apoB-100 peptide fragments were introduced as model compounds for interaction studies. The LDL coating was modified with copper sulphate or hydrolytic enzymes, and the interactions of steroids with the native and oxidized lipoproteins were studied. Lipids were also removed from the LDL particle coating leaving behind an apoB-100 surface for further studies. The development of collagen and collagen decorin coatings was helpful in the elucidation of the interactions of apoB-100 peptide fragments with the primary ECM component, collagen. Furthermore, the collagen I coating provided a good platform for glycation studies and for clarification of LDL interactions with native and modified collagen. All methods developed are inexpensive, requiring just small amounts of biomaterial. Moreover, the experimental conditions in CEC are easily modified, and the analyses can be carried out in a reasonable time frame. Other techniques were employed to support and complement the CEC studies. Scanning electron microscopy and atomic force microscopy provided crucial visual information about the native and modified coatings. Asymmetrical flow field-flow fractionation enabled size measurements of the modified lipoproteins. Finally, the CEC results were exploited to develop new sensor chips for a continuous flow quartz crystal microbalance technique, which provided complementary information about LDL ECM interactions. This thesis demonstrates the potential of CEC as a valuable and flexible technique for surface interaction studies. Further, CEC can serve as a novel microreactor for the in situ modification of LDL and collagen coatings. The coatings developed in this study provide useful platforms for a diversity of future investigations on biological nanodomains.