106 resultados para Hydrogen-Ion Concentration

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The spectral properties in different concentration of Yb ions (0.5-5 mol%)-doped silica glasses are explored in this paper. The glasses are prepared by traditional melting method. The absorption spectra and the fluorescent lifetime (tau(f)) are measured at room temperature and low temperature (18 K). The stimulated cross-section (sigma(emi)) and potential laser properties (beta(min), I-sat, I-min) are calculated based on the absorption spectra. The absorption cross-section (sigma(abs)) are in the range 1.08 x 10(-20) - 1.18 x 10(-20) cm(2) in different glasses, the fluorescence lifetime (tau(f)) change from 1.9 to 1.2 ms with the increase of Yb3+ concentration. The potential laser properties indicate that lead silica glass is a good host for highly Yb ion doping glass. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the acceptance of the electrochemical rusting mechanism, oxygen reduction has been considered the main cathodic process, while H+ reduction has been overlooked for the past four decades because oxygen can be readily renewed due to the thin layer Of Solution film formed during atmospheric corrosion. This study shows that measurable hydrogen call be detected at the surface opposite to the corroding side of the specimen during wet-dry cycles, and a clear correlation exists between the quantities of hydrogen permeated through iron sheet and weight loss. Results Suggest the intrinsic importance of H+ reduction that merits further investigation. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The determination of glucose is possible with the enzymatic reaction of glucose oxidase and potentiometric detection. The signal is proportional to the concentration up to 50 mg/dl. This value is fixed by the concentration of oxygen in the sample. By adding catalase, concentrations up to 2000 mg/dl are detectable. The steepness of the calibration curve is not affected by oxygen concentrations greater than 4 mg/l. In contrast to amperometric sensors, an influence of deposits on the electrodes surface on the signal cannot be found with potentiometric sensors

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The extraction kinetics of ytterbium with sec-nonylphenoxy acetic acid (CA-100) in heptane have been investigated using a constant interfacial area cell with laminar flow. The influence of stirring speed and temperature on the rate indicated that the extraction rate was controlled by the experiment conditions. The plot of interfacial area on the rate showed a linear relationship. This fact together with the low solubility in water and strong surface activity of CA-100 at heptane-water interfaces made the interface the most probable locale for the chemical reactions. The influences of extractant concentration and hydrogen ion concentration on the extraction rate were investigated, and the forward and reverse rate equations for the ytterbium extraction with CA-100 were also obtained. Based on the experimental data, the apparent forward extraction rate constant was calculated. Interfacial reaction models were proposed that agree well with the rate equations obtained from experimental data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In various acidic media, such as H2SO4, HCl, H3PO4, acetic acid of 3 M in hydrogen ion concentration, and pure acetic acid, the adsorption of heteropolyacids composed of molybdenum with the Keggin structures PMo12 and SiMo12 on different activated carbons is studied. In acidic media, the adsorbed amount of heteropolyacids is much higher than that in water. By considering the relation between adsorbed amount and the acid strength of the media, as far as SiMo12 and PMo12 are concerned, there exist different trends.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The absorption spectra of Er:YAG (YAG, yttrium-aluminium-garnet) crystals containing different concentrations of the trivalent erbium ion were measured and the spectral intensity parameters were calculated from these experimental spectra using the Judd-Ofelt model. The results indicate that the phenomenological intensity parameters, OMEGA(lambda) (lambda = 2, 4 and 6), vary as a function of the concentration of the Er3+ ion in the Er:YAG crystal, but no variation in the fluorescence-branching ratios as a function of the concentration of the Er3+ ion is found. An empirical formula is proposed to describe the relationship between the spectral intensity parameters and the Er3+ ion concentration in the Er:YAG crystal. The spectral intensity parameters exhibit a maximum in Er:YAG crystals containing about 1-1.5 at.% Er3+ ion. The effect of the Er3+ ion concentration on the spectral intensity parameters may be attributed to the inhomogeneous lattice distortion in the cell of the Er:YAG crystal caused by the dopant erbium ions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A direct ion beam deposition system designed for heteroepitaxy at a low substrate temperature and for the growth of metastable compounds has been constructed and tested. The system consists of two mass-resolved low-energy ion beams which merge at the target with an incident energy range 50-25 000 eV. Each ion beam uses a Freeman ion source for ion production and a magnetic sector for mass filtering. While a magnetic quadrupole lens is used in one beam for ion optics, an electrostatic quadrupole lens focuses the other beam. Both focusing approaches provide a current density more than 100-mu-A/cm2, although the magnetic quadrupole gives a better performance for ion energies below 200 eV. The typical current of each beam reaches more than 0.3 mA at 100 eV, with a ribbon beam of about 0.3-0.5 x 2 cm2. The target is housed in an ultrahigh vacuum chamber with a base pressure of 1 x 10(-7) Pa and a typical pressure of 5 x 10(-6) Pa when a noncondensable beam like argon is brought into the chamber. During deposition, the target can be heated to 800-degrees-C and scanned mechanically with an electronic scanning control unit. The dual beam system has been used to grow GaN using a Ga+ and a N+ beam, and to study the oxygen and hydrogen ion beam bombardment effects during carbon ion beam deposition. The results showed that the simultaneous arrival of two beams at the target is particularly useful in compound formation and in elucidation of growth mechanisms.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A highly sensitive microstructured polymer optical fiber (MPOF) probe for hydrogen peroxide was made by forming a rhodamine 6G-doped titanium dioxide film on the side walls of array holes in an MPOF. It was found that hydrogen peroxide only has a response to the MPOF probe in a certain concentration of potassium iodide in sulfuric acid solution. The calibration graph of fluorescence intensity versus hydrogen peroxide concentration is linear in the range of 1.6 x 10(-7) mol/L to 9.6 x 10(-5) mol/L. The method, with high sensitivity and a wide linear range, has been applied to the determination of trace amounts of hydrogen peroxide in a few real samples, such as rain water and contact lens disinfectant, with satisfactory results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A new method for immobilization of a chemiluminescent reagent is presented. It is based on immobilizing hematin, a catalyst for luminol reaction, in the bulk of a carbon paste electrode. Bulk-immobilization allows renewal of the surface by simple polishing or cutting to expose anew and fully active surface in the case of fouling or deactivation by other means. By using a hematin-modified carbon paste electrode, the applied potential shifted negatively compared with that of unmodified carbon paste electrode or a glassy carbon electrode. The shift in potential changed the reaction processes and effectively stabilized the chemiluminescent signal during successive measurements. Under this condition, the signal was stable during 3 hours of continuous operation. The log-log plots of the emitted light intensity vs. luminol concentration and hydrogen peroxide concentration were linear over the region 10(-8)-10(-3) mol L-1 with a correlation coefficient of 0.999 and 3.9 x 10(-6)-10(-3) mol L-1 with a correlation coefficient of 0.994, respectively. Application of this method for other chemiluminescent and bioluminescent systems is suggested.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The adsorbed kinetics, proton transportation in electrochemical redox process of 4-pyridyl hydroquinone (4PHQ) self-assembled monolayer (SAM) modified Pt electrode were studied by electrochemical quartz crystal microbalance (EQCM) in situ. It proved that the electrode was modified by a monolayer and underwent a rapid electron transfer. It was a slow adsorbed kinetic process. The ion transfer in the electrochemical redox at the SAM-modified electrode surface mainly involved into the hydrate hydrogen ion.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Propylamine has been selected to investigate the isotope effect of a fast deuteron transfer reaction by ultrasonic relaxation method. Ultrasonic absorption coefficients of propylamine in heavy water (D2O) at 25 degrees C in the concentration range from 0.0107 to 0.6300 mol dm(-3) have been measured by pulse and resonance methods over the frequency range from 0.8 to 220 MHz. A Debye-type single relaxation absorption has been observed in the solution. From the dependence of the ultrasonic relaxation parameters on the concentration and solution pH, the source of the observed relaxation has been attributed to a perturbation of the chemical equilibrium associated with the deuteron transfer reaction. The rate and equilibrium constants have been determined by the measurement of the deuteroxyl ion concentration dependence of the relaxation frequency. Also the standard volume change of the reaction has been determined from the concentration dependence of the maximum absorption per wavelength and the adiabatic compressibility has been calculated from the density and the sound velocity in the solution. These results have then been compared with those obtained for propylamine in light water (H2O). The forward rate constant is greater and the reverse rate constant is smaller in DO than in H2O. The standard volume change for deuteron transfer is greater than that for proton transfer reaction, and the adiabatic compressibility shows a similar trend. These data support an argument that there exists a stronger hydrogen bond in D2O than in H2O. The difference of the stability in the intermediate states, R-ND3+... OD- and R-NH3+... OH-, has also been considered from the results of the isotope effects.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Cyclic voltammetry, electrochemical impedance spectroscopy, and rotating disk electrode voltammetry have been used to study the effect of chloride ions on the dissolved oxygen reduction reaction (ORR) on Q235 carbon steel electrode in a 0.02 M calcium hydroxide (Ca(OH)(2)) solutions imitating the liquid phase in concrete pores. The results indicate that the cathodic process on Q235 carbon steel electrode in oxygen-saturated 0.02 M Ca(OH)(2) with different concentrations of chloride ions contain three reactions except hydrogen evolution: dissolved oxygen reduction, the reduction of Fe(III) to Fe(II), and then the reduction of Fe(II) to Fe. The peak potential of ORR shifts to the positive direction as the chloride ion concentration increases. The oxygen molecule adsorption can be inhibited by the chloride ion adsorption, and the rate of ORR decreases as the concentration of chloride ions increases. The mechanism of ORR is changed from 2e(-) and 4e(-) reactions, occurring simultaneously, to quietly 4e(-) reaction with the increasing chloride ion concentration.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

制备了四种不同铒离子掺杂浓度的碲酸盐玻璃,通过测定吸收光谱计算了吸收谱线的振子强度,根据Judd-Ofelt理论计算了不同浓度下Er^3+离子发光光谱的强度参数Ω(i=2,4,6),计算了自发辐射电偶和磁偶跃迁概率、辐射寿命、荧光分支比等参数,讨论了Er^3+离子浓度变化对以上这些参数的影响。测试了Er^3+:^4I13/2→^4I15/2跃迁对应的荧光光谱和Er^3+:^4I13/2能级荧光寿命。最后应用McCumber理论计算了玻璃中Er^3+:^4I13/2→^4I15/2跃迁对应的受激发射截面大小