970 resultados para wound dehiscence


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case report is on a obese patient who underwent a coronary artery bypass. The immediate postoperative phase, on the 8th day, was characterized by sternal dehiscence with diastasis, from intense coughing. At present, for obese patients there are not any guidelines aimed to prevent the sternal diastasis. The use of a sternum support vest after median sternotomy could be a valuable tool in the postoperative care of our patients, in order to avoid chest wall hyperexpansion and to prevent sternal wound dehiscence and diastasis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To determine the incidence and to explore the risk factors for traumatic graft dehiscence after penetrating keratoplasty. Design: Retrospective case note review. Participants: Five hundred seventy-two consecutive cases were included. Intervention: All subjects who underwent penetrating keratoplasty in 1 regional center between 1992 and 2004 inclusive. Main Outcome Measures: Cases that experienced postoperative traumatic graft dehiscence were identified. Results from 12 other similar studies were pooled for comparison. Results: Fifteen eyes (2.6%) were treated for traumatic wound dehiscence after penetrating keratoplasty. The most striking feature of this series was the bimodal relationship of age and cause of graft dehiscence, with older patients involved in falls and younger patients in accidental or deliberate trauma. Factors that may influence the risk of traumatic graft dehiscence are discussed, in the light of the present findings and pooled data from previous series. Conclusions: This case series indicates that there is long-term risk of traumatic wound dehiscence after penetrating keratoplasty. Younger patients, especially males, should be made aware that their eye, after keratoplasty, will always be vulnerable to injury. High-risk situations should be avoided if possible. Older patients at particular risk should have adequate risk reduction strategies, social support, and supervision, in particular to minimize the risk of falls. © 2008 American Academy of Ophthalmology.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE The purpose of this study was to examine the recurrence rate of wound rupture in primary pilonidal sinus disease (PSD) after median closure. SUBJECTS AND METHODS A total of 583 patients from the German military cohort were interviewed. We compared the choice of surgical therapy, wound dehiscence (if present) and long-term recurrence-free survival for patients with primary open treatment, marsupialization and primary median treatment (closed vs. secondary open, respectively). Actuarial recurrence rate was determined using the Kaplan-Meier calculation with a follow-up of up to 20 years after primary PSD surgery. RESULTS Patients with excision followed by primary open wound treatment showed a significantly lower 5- than 10-year recurrence rate (8.3 vs. 11.2%) compared to the patients with primary midline closure (17.4 vs. 20.5%, p = 0.03). The 20-year recurrence rate was 28% in primary open wound treatment versus 44% in primary midline closure without wound rupture. In contrast to these findings, long-term recurrence rates following secondary open wound treatment (12.2% at 5 years vs. 17.1% at 10 years) tended to be higher (although not significantly, p = 0.57) compared to primary open treatment (8.3% at 5 years vs. 11.2% at 10 years). There was no statistical difference in long-term recurrence rates between secondary open and primary midline closure (p = 0.7). Hence, despite only a short wound closure time experienced before wound rupture, the patient does not fully benefit from an open wound treatment in terms of recurrence rate. CONCLUSION The postoperative pilonidal sinus wound rupture of primary midline closures did not significantly increase the 5- and 10-year long-term recurrence rates compared to uneventfully healing primary midline closures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of the present experimental study was to find out if the applications of coralline hydroxyapatite (HA) can be improved by using bioabsorbable containment or binding substance with particulate HA in mandibular contour augmentation and by using bioabsorbable fibre-reinforced HA blocks in filling bone defects and in anterior lumbar interbody fusion. The use of a separate curved polyglycolide (PGA) containment alone or together with a fast resorbing polyglycolide/polylactide (PGA/PLA) binding substance were compared to the conventional non-contained method in ridge augmentation in sheep. The contained methods decreased HA migration, but the augmentations did not differ significantly. The use of the containment caused a risk for wound dehiscence and infection. Histologically there was a rapid connective tissue ingrowth into the HA graft and it was more abundant with the PGA containment compared to the non-contained augmentation and even additionally rich when the HA particles were bound with PGA/PLA copolymer. However, the bone ingrowth was best in the non-contained augmentation exceeding 10-12 % of the total graft area at 24 weeks. Negligible or no bone ingrowth was seen in the cases where the polymer composite was added to the HA particles and, related to that, foreign-body type cells were seen at the interface between the HA and host bone. The PGA and poly-dl/l-lactide (PDLLA) fibre-reinforced coralline HA blocks were studied in the metaphyseal and in the diaphyseal defects in rabbits. A rapid bone ingrowth was seen inside the both types of implants. Both PGA and PDLLA fibres induced an inflammatory fibrous reaction around themselves but it did not hinder the bone ingrowth. The bone ingrowth pattern was directed according to the loading conditions so that the load-carrying cortical ends of the implants as well as the implants sited in the diaphyseal defects were the most ossified. The fibre-reinforced coralline HA implants were further studied as stand-alone grafts in the lumbar anterior interbody implantation in pigs. The strength of the HA implants proved not to be adequate, the implants fractured in six weeks and the disc space was gradually lost similarly to that of the discectomized spaces. Histologically, small quantities of bone ingrowth was seen in some of the PGA and PDLLA reinforced coralline implants while no bone formation was identified in any of the PDLLA reinforced synthetic porous HA implants. While fragmented, the inner structure of the implants was lost, the bone ingrowth was minimal, and the disc was replaced by the fibrous connective tissue. When evaluated radiologically the grade of ossification was assessed as better than histologically, and, when related to the histologic findings, CT was more dependable than the plain films to show ossification of the implanted disc space. Local kyphosis was a frequent finding along with anterior bone bridging and ligament ossification as a consequence of instability of the implanted segment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introducción Las rupturas agudas del tendón de Aquiles se presentan en pacientes entre 40 y 50 años. Las causas más comunes son actividades deportivas. Se han descrito técnicas mínimamente invasivas, con complicaciones como infección del sitio operatorio, adherencias y la lesión del nervio sural. El propósito de este estudio es determinar el desenlace clínico y funcional, de los pacientes con rupturas agudas del tendón de Aquiles llevados a reparación quirúrgica mínimamente invasiva entre 2011 y 2013 en nuestra institución. Materiales y métodos. Estudio tipo Serie de casos. Se realizó evaluación de fuerza muscular, fatiga muscular, arcos de movilidad con respecto a la extremidad contralateral, la escala AOFAS y se describieron las complicaciones. Resultados. Se evaluaron 21 pacientes de 31 elegibles, diecisiete hombres y cuatro mujeres. Edad promedio de 42,7 años, duración promedio de seguimiento de 17,47 meses. Como complicación hubo una dehiscencia de sutura treinta días después del procedimiento. Los pacientes regresaron a actividades laborales 48 días después de cirugía. El tiempo promedio de retorno a actividades deportivas fue de 8.47 meses. El puntaje promedio en la escala AOFAS fue 90. Los arcos de movilidad del tobillo fueron en promedio de 52° para el lado afectado y 56° en el no intervenido. El número de repeticiones de elevación de talón de la extremidad afectada fue de 58 en promedio. Discusión. Estos resultados sugieren que la técnica mínimamente invasiva para reparación del tendón de Aquiles provee resultados funcionales satisfactorios a corto y mediano plazo con bajas tasas de complicación.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Although the use of local flaps in conservative breast surgery (CBS) reconstruction is a reliable technique, little information has been available regarding outcome following the use of perforator flaps. The purpose of this study is to analyze the feasibility, surgical planning and outcome following CBS reconstruction with intercostal artery perforator (ICAP) flap. Patients/methods: Thirteen patients underwent CBS reconstructions with an ICAP flap. These flaps were raised from adjacent tissue located on the lateral and thoracic region and based on perforators originating from the costal and muscular segment of the intercostal vessels. The technique was indicated in patients with small/moderate volume breasts. Results: Mean time of follow-up was 32 months. Flap complications were evaluated and information on patient satisfaction were collected. 61.5 percent had tumors located in the lower-outer quadrants and 69.2 percent had tumors measuring 2 cm or less (T1). Complications occurred in 3 patients (23%), including wound dehiscence in 2 patients and fat necrosis in one. All cases were treated by conservative approach with a good result. No flap loss or wound infection were reported. 90 percent were either satisfied or very satisfied with their result. Conclusion: The ICAP flap is a reliable technique for immediate CBS reconstruction. The technique is advantageous because it does not require the use of muscle transfer, with minimum donor site morbidity. Success depends on patient selection, coordinated planning with the oncological surgeon and careful intra-operative management. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Although the biodimensional anatomical expander-implant system (BEIS) is a reliable technique, little information has been available regarding outcome following nipple-areola sparing mastectomy (NSM). To perform the resection of glandular tissue, while improving the surgical access and maintaining the nipple-areola vascularization we have developed a new approach for NSM based on the double concentric periareolar incision (DCPI). The purpose of this study is to analyze the feasibility, surgical planning and its outcome following NSM. 18 patients underwent NSM reconstructions. Mean time of follow-up was 29 months. The technique was indicated in patients with small/moderate volume breasts. Flap complications were evaluated and information on aesthetic results and patient satisfaction were collected. 83.3% had tumors measuring 2 cm or less (T1) and 72.1% were stage 0 and 1. All patients presented peripherally tumors located (at least 5 cm from the nipple). Skin complications occurred in 11.1%. One patient (5.5%) presented small skin necrosis and a wound dehiscence was observed in one patient (5.5%). The aesthetic result was good/very good in 94.4 percent and the majority of patients were very satisfied/satisfied. No local recurrences were observed. All complications except one were treated by a conservative approach. DCPI-BEIS is a simple and reliable technique for NSM reconstruction. The success depends on patient selection, coordinated planning with the oncologic surgeon and careful intra-operative and post-operative management. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the macroscopy, microstructure, and tissue reaction of a double-setting a-tricalcium phosphate bone cement used as an intraocular implant in rabbits.Methods: the internal and external surface of the double-setting a-tricalcium phosphate implant was analyzed macroscopically and by scanning electron microscopy. Twelve New Zealand rabbits received 12-mm implants made of double-setting alpha-tricalcium phosphate cement after unilateral evisceration. Clinical evaluation was performed daily for the first 15 days after surgery and at 15-day intervals until the end of the study period. For histopathologic analysis, 3 animals per experimental period were submitted to enucleation at 15, 45, 90, and 180 days.Results: on gross inspection, the external surface of the implant was solid, smooth, and compact. The microarchitecture was characterized by the formation of columns of hexagonal crystals with interconnecting channels forming micropores. No wound dehiscence, signs of infection, or implant extrusion were observed in any animal throughout the study period. Histologic examination revealed the formation of fibrovascular tissue surrounding the implants, and there were signs of minimal integration of the surface limiting the fibrocellular cap with the space previously occupied by the implant.Conclusions: the double-setting alpha-tricalcium phosphate implant behaved as an inert and nonintegratable material. The lack of incorporation of this material by fibrovascular tissue is related to its characteristics of compactness and high resistance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the characteristics of patients with anophthalmic cavity who developed sphere extrusion. Methods: A retrospective observational study was done evaluating 37 patients with anophthalmic cavity and sphere extrusion at the Faculdade de Medicina de Botucatu-UNESP. Results: Extrusion was observed in enucleated and eviscerated cavities. The majority of the patients had the eye removed because of phthisis bulbi or trauma and the extrusion happened 1 or 2 years after the surgery. Extrusion was preceded by conjunctival dehiscence and exposure of the sphere and occurred with all used implants. Conclusion: Complications after orbital implant placement are a possibility. Dehiscence and sphere extrusion may happen and another surgery would be necessary. The patient and the ophthalmologist have to be prepared for this.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: This study aimed to characterize candidates undergo vasectomy in the public health system, Araçatuba- SP and to study related variables. Methods: We surveyed 300 medical patients and vasectomized contacted by telephone to assess several characteristics. The variables analyzed for the study were age, marital status, education, religion, monthly family income and per capita, number of living children, reason for seeking treatment method, contraceptive use, marital relationship quality, decision time (date of intent to perform the procedure) and not because of the procedure. Data were pooled for the analysis of results. Results: The age of the candidates ranged from 23 to 65 years (mean 36.86 years) and average 2.56 living sons. The average monthly family income was R$ 1.079,15, with average per capita income of R$ 249,07. The couple's contraception before the procedure was on account of the woman who used oral anti-conception (84%). The complication rate with the method was around 6.04%, the biggest complication was dehiscence (77.7% of cases of complications), these being mainly during the first 100 cases. Conclusion: Vasectomy is a very effective contraceptive method, with low complication rate and low cost, should be encouraged by the public health system as a means of family planning policy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An adult female free-ranging six-banded armadillo (Euphractus sexcinctus) was presented with an inverted L-shaped fracture of the left pectoral carapace. The fracture was stabilized with the use of three simple interrupted interfragmentary sutures of 2-0 nylon. After 7 days, wound dehiscence occurred, so sutures were replaced and the wound treated topically with castor bean oil cream. Healing of the fracture was observed after 14 days of this treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIMS: To identify the rates and reasons for plate removal (PR) among patients treated for facial fractures. MATERIALS AND METHODS: A retrospective review of files of 238 patients. RESULTS: Forty-eight patients (20.2%) had plates removed. The reason for removal was objective in 33.3% and subjective in 29.2%. The most common subjective reason was cold sensitivity, and the most common objective reason was wound dehiscence/infection. Women had PR for subjective reasons more often than men (p=0.018). Removal was performed more often for subjective reasons after zygomatico-orbital fractures than after mandibular fractures (p=0.002). Plates inserted in the mandible from an intraoral approach were removed more frequently than extraorally inserted mandibular plates, intraorally inserted maxillary plates, and extraorally inserted plates in other locations (p<0.001). Orbital rim plates had a higher risk of being removed than maxillary or frontal bone plates (p=0.02). CONCLUSIONS: Subjective discomfort is a notable reason for PR among Finnish patients, suggesting that the cold climate has an influence on the need for removal. Patients receiving mandibular osteosynthesis with miniplates from an intraoral approach are at risk of hardware removal because of wound dehiscence/infection and loose/broken hardware, reminding us that more rigid fixation devices should not be forgotten despite the widespread use of miniplates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: The aim of this follow-up study was to evaluate the clinical usefulness of a new type of 3-dimensional (3D) miniplate for open reduction and monocortical fixation of mandibular angle fractures. PATIENTS AND METHODS: In 20 consecutive patients, noncomminuted mandibular angle fractures were treated with open reduction and fixation using a 2 mm 3D miniplate system in a transoral approach. All patients were systematically monitored until 6 months postoperatively. Among the outcome parameters recorded were infection, hardware failure, wound dehiscence, and sensory disturbance of the inferior alveolar nerve. RESULTS: The mean operation time from incision to wound closure was 65 minutes. Two patients had a mucosal wound dehiscence with no consequences. None developed an infection requiring a plate removal. All but 2 patients had normal sensory function 3 months after surgery. Plate fracture occurred in one patient in whom a preceding surgical removal of the third molar had been the reason for the mandibular fracture. In the absence of clinical symptoms, the patient declined plate removal. On final follow-up, fracture healing was considered clinically complete in all patients. CONCLUSIONS: The 3D plating system described here is suitable for fixation of simple mandibular angle fractures and is an easy-to-use alternative to conventional miniplates. The system may be contraindicated in patients in whom insufficient interfragmentary bone contact causes minor stability of the fracture.