Evaluation of polymethylmethacrylate as ocular implant in rabbits subjected to evisceration


Autoria(s): Oriá, Arianne Pontes; Dórea Neto, Francisco de Assis; Santos, Luís Alberto dos; Piza, Evandro de Toledo; Brunelli, Adriana Torrecilhas Jorge; Nishimori, Celina Tie; Souza, Ana Letícia Groszewicz de; Gomes Júnior, Deusdete Conceição; Laus, José Luiz
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/08/2012

Resumo

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Após a remoção do volume ocular ou de seu conteúdo, o implante de esferas de diferentes tipos de materiais previne a concentração da cavidade orbital. O objetivo deste estudo foi avaliar a esfera de polimetilmetacrilato (PMMA), utilizado como implante intraocular em coelhos submetidos evisceração. Doze coelhos da raça Nova Zelândia foram submetidos evisceração unilateral do olho esquerdo, com posterior implantação da esfera de PMMA com 12 mm de diâmetro. A avaliação clínica foi realizada diariamente nos primeiros 15 dias após a cirurgia e em intervalos de 15 dias até o final do período de estudo (180 dias). Para análise histopatológica, três animais por período experimental foram submetidos enucleação aos 15, 45, 90 e 180 dias após a evisceração. Não foi observada deiscência da ferida, sinais de infecção ou extrusão do implante em nenhum dos animais durante todo o período do estudo. O exame histológico revelou a formação de tecido fibrovascular ao redor dos implantes. O PMMA comportou-se como material inerte e não- integrável.

Spheres of different types of material are used for the replacement of lost volume after removal of the eye bulb or its content to prevent contraction of the orbital cavity. The aim of this study was to evaluate the scope of polymethylmethacrylate (PMMA) used as intraocular implant in eviscerated rabbit eye. Twelve New Zealand rabbits underwent unilateral evisceration of the left eye, with subsequent implantation of PMMA sphere 12 mm in diameter. Clinical evaluation was performed daily during the first 15 days after surgery and every 15 days until the end of the study period (180 days). For the histopathological analysis, three animals per trial underwent enucleation at 15, 45, 90 and 180 days after evisceration. There was no wound dehiscence, signs of infection or implant extrusion in any animal throughout the study period. Histological examination revealed the formation of fibrovascular tissue around the implants. The PMMA behaved as inert and non-integrable.

Formato

452-457

Identificador

http://dx.doi.org/10.1590/S0034-737X2012000400004

Revista Ceres. Universidade Federal de Viçosa (UFV), v. 59, n. 4, p. 452-457, 2012.

0034-737X

http://hdl.handle.net/11449/29485

10.1590/S0034-737X2012000400004

S0034-737X2012000400004

S0034-737X2012000400004.pdf

Idioma(s)

eng

Publicador

Universidade Federal de Viçosa (UFV)

Relação

Revista Ceres

Direitos

openAccess

Palavras-Chave #prótese intraocular #enucleação #evisceração #intraocular prosthesis #enucleation #evisceration
Tipo

info:eu-repo/semantics/article