The effective notch stress approach for the fatigue strength assessment of welded structures as included in the Fatigue Design Recommendation of the IIW requires the numerical analysis of the elastic notch stress in the weld toe and weld root which is fictitiously rounded with a radius of 1mm. The goal of this thesis work was to consider alternate meshing strategies when using the effective notch stress approach to assess the fatigue strength of load carrying partial penetration fillet-welded cruciform joints. In order to establish guidelines for modeling the joint and evaluating the results, various two-dimensional (2D) finite element analyses were carried out by systematically varying the thickness of the plates, the weld throat thickness, the degree of bending, and the shape and location of the modeled effective notch. To extend the scope of this work, studies were also carried out on the influence of
Resumo:
Due to functional requirement of a structural detail brackets with and without scallop are frequently used in bridges, decks, ships and offshore structure. Scallops are designed to serve as passage way for fluids, to reduce weld length and plate distortions. Moreover, scallops are used to avoid intersection of two or more welds for the fact that there is the presence of inventible inherent initial crack except for full penetrated weld and the formation of multi-axial stress state at the weld intersection. Welding all around the scallop corner increase the possibility of brittle fracture even for the case the bracket is not loaded by primary load. Avoiding of scallop will establish an initial crack in the corner if bracket is welded by fillet welds. If the two weld run pass had crossed, this would have given a 3D residual stress situation. Therefore the presences and absence of scallop necessitates the 3D FEA fatigue resistance of both types of brackets using effective notch stress approach ( ). FEMAP 10.1 with NX NASTRAN was used for the 3D FEA. The first and main objective of this research was to investigate and compare the fatigue resistance of brackets with and without scallop. The secondary goal was the fatigue design of scallops in case they cannot be avoided for some reason. The fatigue resistance for both types of brackets was determined based on approach using 1 mm fictitiously rounded radius based on IIW recommendation. Identical geometrical, boundary and loading conditions were used for the determination and comparison of fatigue resistance of both types of brackets using linear 3D FEA. Moreover the size effect of bracket length was also studied using 2D SHELL element FEA. In the case of brackets with scallop the flange plate weld toe at the corner of the scallop was found to exhibit the highest and made the flange plate weld toe critical for fatigue failure. Whereas weld root and weld toe at the weld intersections were the highly stressed location for brackets without scallop. Thus weld toe for brackets with scallop, and weld root and weld toe for brackets without scallop were found to be the critical area for fatigue failure. Employing identical parameters on both types of brackets, brackets without scallop had the highest except for full penetrated weld. Furthermore the fatigue resistance of brackets without scallop was highly affected by the lack of weld penetration length and it was found out that decreased as the weld penetration was increased. Despite the fact that the very presence of scallop reduces the stiffness and also same time induce stress concentration, based on the 3D FEA it is worth concluding that using scallop provided better fatigue resistance when both types of brackets were fillet welded. However brackets without scallop had the highest fatigue resistance when full penetration weld was used. This thesis also showed that weld toe for brackets with scallop was the only highly stressed area unlike brackets without scallop in which both weld toe and weld root were the critical locations for fatigue failure when different types of boundary conditions were used. Weld throat thickness, plate thickness, scallop radius, lack of weld penetration length, boundary condition and weld quality affected the fatigue resistance of both types of brackets. And as a result, bracket design procedure, especially welding quality and post weld treatment techniques significantly affect the fatigue resistance of both type of brackets.
Resumo:
Tässä tutkimuksessa oli tavoitteena tarkastella analyyttisen laskennan keinoin pienahitsin mitoittamista ja selvittää käytännön kokeissa havaittu a-mitasta poikkeavan vauriotason sijainti poikittain kuormitetuissa pienahitseissä. Perinteinen laskentamallin tarkastelu laa-jennettiin koskemaan mielivaltaisessa kulmassa olevaa laskentatasoa ja suurimman yhdistetyn jännityksen perusteella löydettiin kriittisin leikkaus tasakylkisessä hitsissä. Lisäksi tarkasteltiin voimatasapainon huomioon ottamista mitoituksessa ja luotiin kaksi eri mallia tämän pohjalta. Kolme teoreettisesti oikeampaa mitoitusmallia täydennettiin kattamaan myös erikylkiset hitsit ja todettiin, että kaikilla mitoitusmalleilla erikylkiset hitsit ovat tilavuudeltaan optimaalisempia verrattaessa samanlujuisiin tasakylkisiin hitseihin.
Resumo:
Työssä tutkittiin Ruukki Oyj:n suorasammutetusta S960QC-teräksestä valmistetun kuormaakantavan levyjen ristiliitoksen pienahitsien lujuutta, muodonmuutoskykyä ja vaurioitumismekanismia laajaan kokeelliseen aineistoon perustuen. Tärkeimpänä muuttujana koematriisissa olivat eri MAG-hitsausprosessit. Perinteisen kuumakaarihitsauksen vertailukohteena oli Kemppi Oy:n uusi adaptiivinen valokaaren pituutta säätävä WiseFusion-hitsaustoiminto kuuma- ja pulssikaarihitsauksessa. Näiden kolmen hitsausprosessin rinnalla varioitiin erisuuruisia a-mittoja, eri hitsauslisäaineita ja hitsin erikylkisyyttä. Lisäksi juuritunkeuman estämisen vaikutusta hitsien käyttäytymiseen tutkittiin täydentävällä koesarjalla, jossa tunkeuman muodostuminen estettiin levyjen väliin asetetulla volframilevyllä. Työn perimmäisenä tavoitteena oli selvittää syy aiemmassa tutkimuksessa havaitulle pienahitsien vaurioitumiselle leikkautumalla sularajaa pitkin. Sularajan suhteellista pituutta saadaan kasvatettua estämällä hitsin juuritunkeuma ja absoluuttista pituutta saadaan lisää kateettipoikkeaman avulla. Lisäksi tutkimuksessa oli tarkoitus tuoda esille suurlujuusteräksisen liitoksen eri mitoituslähtökohdat (mm. lämmöntuonnin kontrollointi). Tämän vuoksi hitsausparametrit mitattiin jännitteen ja virran hetkellisiin arvoihin perustuen, jolloin kuuma- ja pulssikaarihitsauksen laskennalliset hitsaustehot ovat vertailukelpoisia. Koehitseistä valmistettiin hieet hitsien tarkan geometrian määrittämiseksi ja liitoksen mekaaniset ominaisuudet tutkittiin vetokokeella. Tulosten perusteella sularajavaurio aktivoituu pulssikaarella hitsatuissa koekappaleissa. Tämä aiheutunee pulssi- ja kuumakaarihitsauksen sularajan mikrorakenteiden eroavaisuudesta. Sularajavaurio näyttää huonontavan hitsien muodonmuutoskykyä, mutta jatkokokeita tuloksen verifioimiseksi on tehtävä. S960QC-teräkselle ominaisen pehmenneen vyöhykkeen vaurio ei aktivoitunut, vaikka Ruukin antamat jäähtymisaikasuositukset ylitettiin reilusti.
Resumo:
Three welding procedures used to rebuild worn shafts in sugar cane mills were analysed: two submerged arc welding processes and one flux cored arc welding (FCAW) process. Sliding wear tests were in accordance with ASTM G 77 standard, using rings of welding material, blocks of bronze SAE 67, and oil as lubricant. The worn surfaces of rings and blocks were analysed by scanning electron microscopy to determine the wear mechanisms. High contact pressure, high operating temperature, and low relative speed were applied in sliding wear tests to match the conditions in sugar cane mills. Transferred material and evidence of adhesive junctions were detected. Additionally, hardened fragments produced abrasive grooves on the worn surfaces. The welding deposits that presented strong adhesion on the worn surface showed higher mass loss than the materials that presented more abrasive characteristics. Plastic mechanical properties were measured and related to the mass loss. The tested materials presented similar hardness but different yield stress and hardening coefficient. A relationship between wear, strain hardening coefficient, and yield stress was found. The welding deposit that presented the highest hardening coefficient showed the highest mass loss, with evidence of severe adhesion on the worn surface.
Resumo:
This work presents a comparison between laser weld (LBW) and electric resistance spot weld (ERSW) processes used for assemblies of components in a body-in-white (BIW) at a world class automotive industry. It is carried out by evaluating the mechanical strength modeled both by experimental and numerical methods. An ""Arcan"" multiaxial test was designed and manufactured in order to enable 0 degrees, 45 degrees and 90 degrees directional loadings. The welded specimens were uncoated low carbon steel sheets (S-y = 170 MPa) used currently at the automotive industry, with two different thicknesses: 0.80 and 1.20 mm. A numerical analysis was carried out using the finite element method (FEM) through LS-DYNA code. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Welded equipment for cryogenic applications is utilized in chemical, petrochemical, and metallurgical industries. One material suitable for cryogenic application is austenitic stainless steel, which usually doesn`t present ductile/brittle transition temperature, except in the weld metal, where the presence of ferrite and micro inclusions can promote a brittle failure, either by ferrite cleavage or dimple nucleation and growth, respectively. A 25-mm- (1-in.-) thick AISI 304 stainless steel base metal was welded with the SAW process using a 308L solid wire and two kinds of fluxes and constant voltage power sources with two types of electrical outputs: direct current electrode positive and balanced square wave alternating current. The welded joints were analyzed by chemical composition, microstructure characterization, room temperature mechanical properties, and CVN impact test at -100 degrees C (-73 degrees F). Results showed that an increase of chromium and nickel content was observed in all weld beads compared to base metal. The chromium and nickel equivalents ratio for the weld beads were always higher for welding with square wave AC for the two types of fluxes than for direct current. The modification in the Cr(eq)/Ni(eq) ratio changes the delta ferrite morphology and, consequently, modifies the weld bead toughness at lower temperatures. The oxygen content can also affect the toughness in the weld bead. The highest absorbed energy in a CVN impact test was obtained for the welding condition with square wave AC electrical output and neutral flux, followed by DC(+) electrical output and neutral flux, and square wave AC electrical output and alloyed flux.
Resumo:
This work describes the development of an engineering approach based upon a toughness scaling methodology incorporating the effects of weld strength mismatch on crack-tip driving forces. The approach adopts a nondimensional Weibull stress, (sigma) over bar (w), as a the near-tip driving force to correlate cleavage fracture across cracked weld configurations with different mismatch conditions even though the loading parameter (measured by J) may vary widely due to mismatch and constraint variations. Application of the procedure to predict the failure strain for an overmatch girth weld made of an API X80 pipeline steel demonstrates the effectiveness of the micromechanics approach. Overall, the results lend strong support to use a Weibull stress based procedure in defect assessments of structural welds.
Resumo:
This work examines the effect of weld strength mismatch on fracture toughness measurements defined by J and CTOD fracture parameters using single edge notch bend (SE(B)) specimens. A central objective of the present study is to enlarge on previous developments of J and CTOD estimation procedures for welded bend specimens based upon plastic eta factors (eta) and plastic rotational factors (r (p) ). Very detailed non-linear finite element analyses for plane-strain models of standard SE(B) fracture specimens with a notch located at the center of square groove welds and in the heat affected zone provide the evolution of load with increased crack mouth opening displacement required for the estimation procedure. One key result emerging from the analyses is that levels of weld strength mismatch within the range +/- 20% mismatch do not affect significantly J and CTOD estimation expressions applicable to homogeneous materials, particularly for deeply cracked fracture specimens with relatively large weld grooves. The present study provides additional understanding on the effect of weld strength mismatch on J and CTOD toughness measurements while, at the same time, adding a fairly extensive body of results to determine parameters J and CTOD for different materials using bend specimens with varying geometries and mismatch levels.
Resumo:
This work reports the implemen tation and verification of a new so lver in OpenFOAM® open source computational library, able to cope w ith integral viscoelastic models based on the integral upper-convected Maxwell model. The code is verified through the comparison of its predictions with anal ytical solutions and numerical results obtained with the differential upper-convected Maxwell model
Resumo:
Magdeburg, Univ., Fak. für Maschinenbau, Diss., 2014
Resumo:
Malnutrition affects 40-50% of patients with ear, nose and throat (ENT) cancer. The aim of this study was to assess changes induced by a specific nutritional supplement enriched with n-3 polyunsaturated fatty acids, fiber and greater amounts of proteins and electrolytes, as compared with a standard nutritional supplement, on markers of inflammation, oxidative stress and metabolic status of ENT cancer patients undergoing radiotherapy (RT). Fourteen days after starting RT, 26 patients were randomly allocated to one of two groups, 13 supplemented with Prosure, an oncologic formula enriched with n-3 polyunsaturated fatty acids, fiber and greater amounts of proteins and electrolytes (specific supplement), and 13 supplemented with Standard-Isosource (standard supplement). Patients were evaluated before RT, and 14, 28 and 90 days after starting RT. The results showed that there were no significant differences between the groups, but greater changes were observed in the standard supplement group, such as a decline in body mass index (BMI), reductions in hematocrit, erythrocyte, eosinophil and albumin levels, and a rise in creatinine and urea levels. We concluded that metabolic, inflammatory and oxidative stress parameters were altered during RT, and began to normalize at the end of the study. Patients supplemented with Prosure showed an earlier normalization of these parameters, with more favorable changes in oxidative stress markers and a more balanced evolution, although the difference was not significant.
Resumo:
Abstract A prospective 1-year follow-up study in ear, nose, and throat (ENT) cancer patients was carried out one year after radiotherapy to assess the effect of varying consumption of ω3 fatty acid according to whether they consumed more or less than the 50th percentile of ω3 fatty acids. Clinical, analytical, inflammatory (CRP and IL-6), and oxidative variables (TAC, GPx, GST, and SOD) were evaluated. The study comprised 31 patients (87.1% men), with a mean age of 61.3 ± 9.1 years. Hematological variables showed significant differences in the patients with a lower consumption of ω3 fatty acids. A lower mortality and longer survival were found in the group with ω3 fatty acid consumption ≥50th percentile but the differences were not significant. No significant difference was reached in toxicity, inflammation, and oxidative stress markers. The group with ω3 fatty acid consumption <50th percentile significantly experienced more hematological and immune changes.
Resumo:
The performance of the Xpert MRSA polymerase chain reaction (PCR) assay on pooled nose, groin, and throat swabs (three nylon flocked eSwabs into one tube) was compared to culture by analyzing 5,546 samples. The sensitivity [0.78, 95 % confidence interval (CI) 0.73-0.82] and specificity (0.99, 95 % CI 0.98-0.99) were similar to the results from published studies on separated nose or other specimens. Thus, the performance of the Xpert MRSA assay was not affected by pooling the three specimens into one assay, allowing a higher detection rate without increasing laboratory costs, as compared to nose samples alone.