904 resultados para visual analog scale


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To investigate the relationship between two assessments to quantify delayed onset muscle soreness [DOMS]: visual analog scale [VAS] and pressure pain threshold [PPT]. Methods: Thirty-one healthy young men [25.8 ± 5.5 years] performed 10 sets of six maximal eccentric contractions of the elbow flexors with their non-dominant arm. Before and one to four days after the exercise, muscle pain perceived upon palpation of the biceps brachii at three sites [5, 9 and 13 cm above the elbow crease] was assessed by VAS with a 100 mm line [0 = no pain, 100 = extremely painful], and PPT of the same sites was determined by an algometer. Changes in VAS and PPT over time were compared amongst three sites by a two-way repeated measures analysis of variance, and the relationship between VAS and PPT was analyzed using a Pearson product-moment correlation. Results: The VAS increased one to four days after exercise and peaked two days post-exercise, while the PPT decreased most one day post-exercise and remained below baseline for four days following exercise [p < 0.05]. No significant difference among the three sites was found for VAS [p = 0.62] or PPT [p = 0.45]. The magnitude of change in VAS did not significantly correlate with that of PPT [r = −0.20, p = 0.28]. Conclusion: These results suggest that the level of muscle pain is not region-specific, at least among the three sites investigated in the study, and VAS and PPT provide different information about DOMS, indicating that VAS and PPT represent different aspects of pain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this study was to verify the discriminative power of the most widely used pain assessment instruments. Methods: The sample consisted of 279 subjects divided into Fibromyalgia Group (FM- 205 patients with fibromyalgia) and Control Group (CG-74 healthy subjects), mean age 49.29 +/- 10.76 years. Only 9 subjects were male, 6 in FM and 3 in CG. FM were outpatients from the Rheumatology Clinic of the University of Sao Paulo - Hospital das Clinicas (HCFMUSP); the CG included people accompanying patients and hospital staff with similar socio-demographic characteristics. Three instruments were used to assess pain: the McGill Pain Questionnaire (MPQ), the Visual Analog Scale (VAS), and the Dolorimetry, to measure pain threshold on tender points (generating the TP index). In order to assess the discriminative power of the instruments, the measurements obtained were submitted to descriptive analysis and inferential analysis using ROC Curve - sensibility (S), specificity (S I) and area under the curve (AUC) - and Contingence tables with Chi-square Test and odds ratio. Significance level was 0.05. Results: Higher sensibility, specificity and area under the curve was obtained by VAS (80%, 80% and 0.864, respectively), followed by Dolorimetry (S 77%, S177% and AUC 0.851), McGill Sensory (S 72%, S167% and AUC 0.765) and McGill Affective (S 69%, S1 67% and AUC 0.753). Conclusions: VAS presented the higher sensibility, specificity and AUC, showing the greatest discriminative power among the instruments. However, these values are considerably similar to those of Dolorimetry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Hereditary angioedema (HAE) is a rare, debilitating, potentially life-threatening condition characterized by recurrent acute attacks of edema of the skin, face/upper airway, and gastrointestinal and urogenital tracts. During a laryngeal attack, people with HAE may be at risk of suffocation, while other attacks are often associated with intense pain, disfigurement, disability, and/or vomiting. The intensity of some symptoms is known only to the person experiencing them. Thus, interview studies are needed to explore such experience and patient-reported outcome measures (PROMs) are required for systematic assessment of symptoms in the clinical setting and in clinical trials of treatments for acute HAE attacks.

Objective: The aim of this interview study was to assess the content validity and suitability of four visual analog scale (VAS) instruments for use in clinical studies. The VAS instruments were designed to assess symptoms at abdominal, oro-facial-pharyngeal-laryngeal, peripheral, and urogenital attack locations. This is the first known study to report qualitative data about the patient's experience of the rare disorder, HAE.

Methods: Semi-structured exploratory and cognitive debriefing interviews were conducted with 27 adults with a confirmed clinical/laboratory diagnosis of HAE (baseline plasma level of functional plasma protein C1 esterase inhibitor [C1INH] <50% of normal without evidence for acquired angioedema). There were 17 participants from the US and 10 from Italy, with mean age 42.5 (SD 14.5) years, range 18–72 years, mean HAE duration 21.3 (SD 14.1) years, range 1–45 years, 67% female, and 44% VAS-naïve. Experience of acute angioedema attacks was first explored, noting spontaneous mentions by participants of HAE symptomatology. Cognitive debriefing of the VAS instruments was undertaken to assess the suitability, comprehensibility, and relevance of the VAS items. Asymptomatic participants completed the VAS instruments relevant to their angioedema experience, reporting as if they were experiencing an acute angioedema attack at the time. Interviews were conducted in the clinic setting in the US and Italy over an 8-month period.

Results: Participants mentioned spontaneously almost all aspects of acute angioedema attacks covered by the four VAS instruments, thus providing strong support for inclusion of nearly all VAS items, with no important symptoms missing. Predominant symptoms found to be associated with acute angioedema attacks were edema and pain, and there was evidence of varying degrees of disruption to everyday activities supporting the inclusion of an overall severity item reflecting the disabling effects of HAE symptoms. VAS item wording was understood by participants.

Conclusion: This interview study explored and reported the patient experience of HAE attacks. It demonstrated the content validity of the four anatomical location HAE VAS instruments and their suitability for use in clinical trials of recombinant human C1INH (rhC1INH) treatment for ascertaining trial participants' assessments of the severity of acute angioedema symptoms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Visual analog scales are frequently used as a means of allowing participants to rate symptoms during clinical trials. The accuracy and reproducibility of these scales play an important role in determining the experimental value of the data they provide. This study was initiated to compare the data collected using paper- and computer-based (Tablet PC) analog scales to better understand the variability in data provided by a visual analog scale.

Methods: Thirty participants rated ocular comfort, redness, and clarity of vision (right and left eyes) on a nondemarcated horizontal line on both paper and a Tablet PC. Measurements were taken in the morning between the hours of 8:30 and 10:30 am and again the same day between 2:30 and 4:30 pm.

Results: The mean difference between the measures recorded in the morning for the 2 media was 2.6 ± 0.9 (confidence intervals, 2 standard errors of the differences) units on a 100 unit scale, with the Tablet PC having the higher mean measure. The limits of agreement (2 standard deviations of the differences) was 9.4 units. Comparing the difference of the differences (1.0 ± 1.3) between the 2 methods of measure (morning vs. afternoon) the visual analog scales on the Tablet PC seemed to have good reproducibility of agreement in comparison with the paper version.

Conclusions: Discrepancy analysis yielded no significant difference and slight bias between paper- and computer-based analog scales. Repeatability of measures using the Tablet PC was also demonstrated. These results suggest that the choice of medium does not significantly influence the outcome for subjective analog scales.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN: Clinical measurement. OBJECTIVE: To translate and culturally adapt the Lower Extremity Functional Scale (LEFS) into a Brazilian Portuguese version, and to test the construct and content validity and reliability of this version in patients with knee injuries. BACKGROUND: There is no Brazilian Portuguese version of an instrument to assess the function of the lower extremity after orthopaedic injury. METHODS: The translation of the original English version of the LEFS into a Brazilian Portuguese version was accomplished using standard guidelines and tested in 31 patients with knee injuries. Subsequently, 87 patients with a variety of knee disorders completed the Brazilian Portuguese LEES, the Medical Outcomes Study 36-Item Short-Form Health Survey, the Western Ontario and McMaster Universities Osteoarthritis Index, and the International Knee Documentation Committee Subjective Knee Evaluation Form and a visual analog scale for pain. All patients were retested within 2 days to determine reliability of these measures. Validation was assessed by determining the level of association between the Brazilian Portuguese LEFS and the other outcome measures. Reliability was documented by calculating internal consistency, test-retest reliability, and standard error of measurement. RESULTS: The Brazilian Portuguese LEES had a high level of association with the physical component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.82), the Western Ontario and McMaster Universities Osteoarthritis Index (r = 0.87), the International Knee Documentation Committee Subjective Knee Evaluation Form (r = 0.82), and the pain visual analog scale (r = -0.60) (all, P<.05). The Brazilian Portuguese LEES had a low level of association with the mental component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.38, P<.05). The internal consistency (Cronbach alpha = .952) and test-retest reliability (intraclass correlation coefficient = 0.957) of the Brazilian Portuguese version of the LEES were high. The standard error of measurement was low (3.6) and the agreement was considered high, demonstrated by the small differences between test and retest and the narrow limit of agreement, as observed in Bland-Altman and survival-agreement plots. CONCLUSION: The translation of the LEFS into a Brazilian Portuguese version was successful in preserving the semantic and measurement properties of the original version and was shown to be valid and reliable in a Brazilian population with knee injuries. J Ort hop Sports Phys Ther 2012;42(11):932-939, Epub 9 October 2012. doi:10.2519/jospt.2012.4101

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To assess the visual performance of Swiss hand surgeons in an environment similar to their workplace. The influence of Galilean (lenses only) and Keplerian loupes (lenses and prisms), the surgeon's age, and the credibility of a self-assessment of his or her own optical performance were evaluated. METHODS Sixty-three hand surgeons between 29 and 68 years of age with 70 loupes were included in the study (Galilean n = 35, Keplerian n = 35). The visual performance as surgeons was self-assessed on a modified visual analog scale and objectively measured with miniaturized visual tests in a simulated clinical setting. We evaluated the influence of the optical device by comparing Galilean and Keplerian loupes and the influence of the surgeon's age by comparing 2 subgroups: < 40 years and ≥ 40 years. RESULTS The correlation between self-assessment and objective visual performance was weak, with a Spearman rank correlation coefficient of 0.25. The near visual acuity with habitual optical aids showed considerable variability, with a range of 300% in the dimension of the smallest detected structure. The near visual acuity was significantly lower in the older group ≥ 40 years than in the younger group < 40 years with both Galilean and Keplerian loupes. Keplerian loupes allowed a significantly higher visual performance than Galilean loupes. Surgeons 40 years or older using Keplerian loupes had a similar visual acuity to surgeons younger than 40 years with Galilean loupes. CONCLUSIONS The magnified near vision of hand surgeons showed an important individual variability. Self-assessment was not a valuable instrument for surgeons to estimate their own near vision. Hand surgeons older than 40 years should use higher magnification loupes. TYPE OF STUDY/LEVEL OF EVIDENCE Diagnostic III.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Purpose Although plantar fascial thickening is a sonographic criterion for the diagnosis of plantar fasciitis, the effect of local loading and structural factors on fascial morphology are unknown. The purposes of this study were to compare sonographic measures of fascial thickness and radiographic measures of arch shape and regional loading of the foot during gait in individuals with and without unilateral plantar fasciitis and to investigate potential relationships between these loading and structural factors and the morphology of the plantar fascia in individuals with and without heel pain. Subjects The participants were 10 subjects with unilateral plantar fasciitis and 10 matched asymptomatic controls. Methods Heel pain on weight bearing was measured by a visual analog scale. Fascial thickness and static arch angle were determined from bilateral sagittal sonograms and weight-bearing lateral foot roentgenograms. Regional plantar loading was estimated from a pressure plate. Results On average, the plantar fascia of the symptomatic limb was thicker than the plantar fascia of the asymptomatic limb (6.1±1.4 mm versus 4.2±0.5 mm), which, in turn, was thicker than the fascia of the matched control limbs (3.4±0.5 mm and 3.5±0.6 mm). Pain was correlated with fascial thickness, arch angle, and midfoot loading in the symptomatic foot. Fascial thickness, in turn, was positively correlated with arch angle in symptomatic and asymptomatic feet and with peak regional loading of the midfoot in the symptomatic limb. Discussion and Conclusion The findings indicate that fascial thickness and pain in plantar fasciitis are associated with the regional loading and static shape of the arch.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper was to investigate the association between appetite and Kidney-Disease Specific Quality of Life in maintenance hemodialysis patients. Quality of Life (QoL) was measured using the Kidney Disease Quality Of Life survey. Appetite was measured using self-reported categories and a visual analog scale. Other nutritional parameters included Patient-Generated Subjective Global Assessment (PGSGA), dietary intake, body mass index and biochemical markers C-Reactive Protein and albumin. Even in this well nourished sample (n=62) of hemodialysis patients, PGSGA score (r=-0.629), subjective hunger sensations (r=0.420) and body mass index (r=-0.409) were all significantly associated with the Physical Health Domain of QoL. As self-reported appetite declined, QoL was significantly lower in nine domains which were mostly in the SF36 component and covered social functioning and physical domains. Appetite and other nutritional parameters were not as strongly associated with the Mental Health domain and Kidney Disease Component Summary Domains. Nutritional parameters, especially PGSGA score and appetite, appear to be important components of the physical health domain of QoL. As even small reductions in nutritional status were associated with significantly lower QoL scores, monitoring appetite and nutritional status is an important component of care for hemodialysis patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Postburn itch is reported to affect up to 87% of the burn population. Although treatments for postburn itch are multimodal, they remain consistently ineffective. However, recent anecdotal evidence from several outpatients at a tertiary referral hospital suggests that a cream combining beeswax and several herbal oils may be effective in the minimization of postburn itch. The aim of this study was to test the efficacy of beeswax and herbal oil cream against the standard treatment of aqueous cream in the provision of relief from the symptoms of postburn itch. A randomized controlled trial compared two groups using a visual analog scale, frequency of cream application, itch recurrence after cream application, use of antipruritic medications, and sleep disturbance to determine the effect of itch severity and duration. Fifty-two participants were enrolled in the study (84% male) with a mean age of 35 years (SD = 16) and mean burn TBSA of 7.2% (SD = 7.7). Study results found that the beeswax and herbal oil cream reduce itch after application more frequently than aqueous cream (P = .001). In addition, when managed with beeswax and herbal oil cream, participants found that their itch recurred later (P ≤ .001) and their use of antipruritic medications was lower (P = .023). Findings of this study suggest beeswax and herbal oil cream to be more effective in the minimization of postburn itch than aqueous cream. Given this, a larger study examining the efficacy of beeswax and herbal oil cream appears warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the presence of spinal inflammation with and without sacroiliac (SI) joint inflammation on magnetic resonance imaging (MRI) in patients with active nonradiographic axial spondyloarthritis (SpA), and to compare the disease characteristics of these subgroups. Methods: ABILITY-1 is a multicenter, randomized, controlled trial of adalimumab versus placebo in patients with nonradiographic axial SpA classified using the Assessment of SpondyloArthritis international Society axial SpA criteria. Baseline MRIs were centrally scored independently by 2 readers using the Spondyloarthritis Research Consortium of Canada (SPARCC) method for the SI joints and the SPARCC 6-discovertebral unit method for the spine. Positive evidence of inflammation on MRI was defined as a SPARCC score of >2 for either the SI joints or the spine. Results: Among patients with baseline SPARCC scores, 40% had an SI joint score of >2 and 52% had a spine score of >2. Forty-nine percent of patients with baseline SI joint scores of <2, and 58% of those with baseline SI joint scores of >2, had a spine score of >2. Comparison of baseline disease characteristics by baseline SI joint and spine scores showed that a greater proportion of patients in the subgroup with a baseline SPARCC score of >2 for both SI joints and spine were male, and patients with spine and SI joint scores of <2 were younger and had shorter symptom duration. SPARCC spine scores correlated with baseline symptom duration, and SI joint scores correlated negatively with the baseline Bath Ankylosing Spondylitis Disease Activity Index, but neither correlated with the baseline Ankylosing Spondylitis Disease Activity Score, total back pain, the patient's global assessment of disease activity, the Bath Ankylosing Spondylitis Functional Index, morning stiffness, nocturnal pain, or C-reactive protein level. Conclusion: Assessment by experienced readers showed that spinal inflammation on MRI might be observed in half of patients with nonradiographic axial SpA without SI joint inflammation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract PURPOSE: Compensatory responses may attenuate the effectiveness of exercise training in weight management. The aim of this study was to compare the effect of moderate- and high-intensity interval training on eating behavior compensation. METHODS: Using a crossover design, 10 overweight and obese men participated in 4-week moderate (MIIT) and high (HIIT) intensity interval training. MIIT consisted of 5-min cycling stages at ± 20% of mechanical work at 45%VO(2)peak, and HIIT consisted of alternate 30-s work at 90%VO(2)peak and 30-s rests, for 30 to 45 min. Assessments included a constant-load exercise test at 45%VO(2)peak for 45 min followed by 60-min recovery. Appetite sensations were measured during the exercise test using a Visual Analog Scale. Food preferences (liking and wanting) were assessed using a computer-based paradigm, and this paradigm uses 20 photographic food stimuli varying along two dimensions, fat (high or low) and taste (sweet or nonsweet). An ad libitum test meal was provided after the constant-load exercise test. RESULTS: Exercise-induced hunger and desire to eat decreased after HIIT, and the difference between MIIT and HIIT in desire to eat approached significance (p = .07). Exercise-induced liking for high-fat nonsweet food tended to increase after MIIT and decreased after HIIT (p = .09). Fat intake decreased by 16% after HIIT, and increased by 38% after MIIT, with the difference between MIIT and HIIT approaching significance (p = .07). CONCLUSIONS: This study provides evidence that energy intake compensation differs between MIIT and HIIT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Summary Bisphosphonates can increase bone mineral density (BMD) in children with osteogenesis imperfecta (OI). In this study of adults with OI type I, risedronate increased BMD at lumbar spine (but not total hip) and decreased bone turnover. However, the fracture rate in these patients remained high. Introduction Intravenous bisphosphonates given to children with OI can increase BMD and reduce fracture incidence. Oral and/or intravenous bisphosphonates may have similar effects in adults with OI. We completed an observational study of the effect of risedronate in adults with OI type I. Methods Thirty-two adults (mean age, 39 years) with OI type I were treated with risedronate (total dose, 35 mg weekly) for 24 months. Primary outcome measures were BMD changes at lumbar spine (LS) and total hip (TH). Secondary outcome measures were fracture incidence, bone pain, and change in bone turnover markers (serum procollagen type I aminopropeptide (P1NP) and bone ALP). A meta-analysis of published studies of oral bisphosphonates in adults and children with OI was performed. Results Twenty-seven participants (ten males and seventeen females) completed the study. BMD increased at LS by 3.9% (0.815 vs. 0.846 g/cm 2, p=0.007; mean Z-score, -1.93 vs. -1.58, p=0.002), with no significant change at TH. P1NP fell by 37% (p=0.00041), with no significant change in bone ALP (p=0.15). Bone pain did not change significantly (p=0.6). Fracture incidence remained high, with 25 clinical fractures and 10 major fractures in fourteen participants (0.18 major fractures per person per year), with historical data of 0.12 fractures per person per year. The meta-analysis did not demonstrate a significant difference in fracture incidence in patients with OI treated with oral bisphosphonates. Conclusions Risedronate in adults with OI type I results in modest but significant increases in BMD at LS, and decreased bone turnover. However, this may be insufficient to make a clinically significant difference to fracture incidence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND This study compared the effects of three silver dressing combinations on small to medium size acute partial thickness burns in children, focusing on re-epithelialization time, pain and distress during dressing changes. METHOD Children (0-15 years) with clean, ≤ 10% total body surface area (TBSA) partial thickness burns who met the inclusion criteria were included in the study. Children received either (1) Acticoat™; (2) Acticoat™ with Mepitel™; or (3) Mepilex Ag™ dressings. Measures of burn re-epithelialization, pain, and distress were recorded at dressing changes every 3-5 days until full re-epithelialization occurred. RESULTS One hundred and three children were recruited with 96 children included for analysis. No infections were detected for the course of the study. When adjusted for burn depth, Acticoat™ significantly increased the expected days to full re-epithelialization by 40% (IRR = 1.40; 95% CI: 1.14-1.73, p < 0.01) and Acticoat™ with Mepitel™ significantly increased the expected days to full re-epithelialization by 33% (IRR = 1.33; 95% CI: 1.08-1.63, p ≤ 0.01) when compared to Mepilex Ag™. Expected FLACC scores in the Mepilex Ag™ group were 32% lower at dressing removal (p = 0.01) and 37% lower at new dressing application (p = 0.04); and scores in the Acticoat™ with Mepitel™ group were 23% lower at dressing removal (p = 0.04) and 40% lower at new dressing application (p < 0.01), in comparison to the Acticoat™ group. Expected Visual Analog Scale-Pain (VAS-P) scores were 25% lower in the Mepilex Ag™ group at dressing removal (p = 0.04) and 34% lower in the Acticoat™ with Mepitel™ group (p = 0.02) at new dressing application in comparison to the Acticoat™ group. There was no significant difference between the Mepilex Ag™ and the Acticoat™ with Mepitel™ groups at all timepoints and with any pain measure. CONCLUSION Mepilex Ag™ is an effective silver dressing, in terms of accelerated wound re-epithelialization time (compared to Acticoat™ and Acticoat™ with Mepitel™) and decreased pain during dressing changes (compared to Acticoat™), for clean, < 10% TBSA partial thickness burns in children.