969 resultados para valve replacement repair


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) as well as thoracic and abdominal endovascular aortic repair (TEVAR and EVAR) rely on accurate pre- and postprocedural imaging. This review article discusses the application of imaging, including preprocedural assessment and measurements as well as postprocedural imaging of complications. Furthermore, the exciting perspective of computational fluid dynamics (CFD) based on cross-sectional imaging is presented. TAVR is a minimally invasive alternative for treatment of aortic valve stenosis in patients with high age and multiple comorbidities who cannot undergo traditional open surgical repair. Given the lack of direct visualization during the procedure, pre- and peri-procedural imaging forms an essential part of the intervention. Computed tomography angiography (CTA) is the imaging modality of choice for preprocedural planning. Routine postprocedural follow-up is performed by echocardiography to confirm treatment success and detect complications. EVAR and TEVAR are minimally invasive alternatives to open surgical repair of aortic pathologies. CTA constitutes the preferred imaging modality for both preoperative planning and postoperative follow-up including detection of endoleaks. Magnetic resonance imaging is an excellent alternative to CT for postoperative follow-up, and is especially beneficial for younger patients given the lack of radiation. Ultrasound is applied in screening and postoperative follow-up of abdominal aortic aneurysms, but cross-sectional imaging is required once abnormalities are detected. Contrast-enhanced ultrasound may be as sensitive as CTA in detecting endoleaks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contexte: La régurgitation mitrale (RM) est une maladie valvulaire nécessitant une intervention dans les cas les plus grave. Une réparation percutanée de la valve mitrale avec le dispositif MitraClip est un traitement sécuritaire et efficace pour les patients à haut risque chirurgical. Nous voulons évaluer les résultats cliniques et l'impact économique de cette thérapie par rapport à la gestion médicale des patients en insuffisance cardiaque avec insuffisance mitrale symptomatique. Méthodes: L'étude a été composée de deux phases; une étude d'observation de patients souffrant d'insuffisance cardiaque et de régurgitation mitrale traitée avec une thérapie médicale ou le MitraClip, et un modèle économique. Les résultats de l'étude observationnelle ont été utilisés pour estimer les paramètres du modèle de décision, qui a estimé les coûts et les avantages d'une cohorte hypothétique de patients atteints d'insuffisance cardiaque et insuffisance mitrale sévère traitée avec soit un traitement médical standard ou MitraClip. Résultats: La cohorte de patients traités avec le système MitraClip était appariée par score de propension à une population de patients atteints d'insuffisance cardiaque, et leurs résultats ont été comparés. Avec un suivi moyen de 22 mois, la mortalité était de 21% dans la cohorte MitraClip et de 42% dans la cohorte de gestion médicale (p = 0,007). Le modèle de décision a démontré que MitraClip augmente l'espérance de vie de 1,87 à 3,60 années et des années de vie pondérées par la qualité (QALY) de 1,13 à 2,76 ans. Le coût marginal était 52.500 $ dollars canadiens, correspondant à un rapport coût-efficacité différentiel (RCED) de 32,300.00 $ par QALY gagné. Les résultats étaient sensibles à l'avantage de survie. Conclusion: Dans cette cohorte de patients atteints d'insuffisance cardiaque symptomatique et d insuffisance mitrale significative, la thérapie avec le MitraClip est associée à une survie supérieure et est rentable par rapport au traitement médical.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Valvuloplasty of the aortic valve is currently used in selected patients for severe calcified aortic valve disease, but clinical effectiveness is low and complication rate remains high. In this study, the total particle load after valvuloplasty and the embolization risk of calcific debris into the coronary arteries was analyzed in an in vitro model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The perioperative risk for redo surgical aortic valve replacement (S-AVR) in patients with severe aortic stenosis and prior coronary artery bypass grafting (CABG) is increased. Transcatheter aortic valve implantation (TAVI) represents an alternative. We assessed the perioperative and mid-term clinical outcome of patients undergoing S-AVR or TAVI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper was to evaluate gender-related differences in patients undergoing mechanical aortic valve replacement with the CarboMedics valve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aortic stenosis has become the most frequent type of valvular heart disease in Europe and North America and presents in the large majority of patients as calcified aortic stenosis in adults of advanced age. Surgical aortic valve replacement has been recognized to be the definitive therapy which improves considerably survival for severe aortic stenosis since more than 40 years. In the most recent period, operative mortality of isolated aortic valve replacement for aortic stenosis varies between 1–3% in low-risk patients younger than 70 years and between 4 and 8% in selected older adults. Long-term survival following aortic valve replacement is close to that observed in a control population of similar age. Numerous observational studies have consistently demonstrated that corrective surgery in symptomatic patients is invariably followed by a subjective improvement in quality of life and a substantial increase in survival rates. More recently, transcatheter aortic valve implantation (TAVI) has been demonstrated to be feasible in patients with high surgical risk using either a retrograde transfemoral or transsubclavian approach or an antegrade, transapical access. Reported 30-day mortality ranges between 5 and 15%) and is acceptable when compared to the risk predicted by the logistic EuroSCORE (varying between 20 and 35%) and the STS Score, although the EuroScore has been shown to markedly overestimate the effective operative risk. One major concern remains the high rate of paravalvular regurgitation which is observed in up to 85% of the patients and which requires further follow-up and critical evaluation. In addition, long-term durability of these valves with a focus on the effects of crimping remains to be addressed, although 3-5 year results are promising. Sutureless biological valves were designed to simplify and significantly accelerate the surgical replacement of a diseased valve and allow complete excision of the calcified native valve. Until now, there are 3 different sutureless prostheses that have been approved. The 3f Enable valve from ATS-Medtronic received CE market approval in 2010, the Perceval S from Sorin during Q1 of 2011 and the intuity sutureless prosthesis from Edwards in 2012. All these devices aim to facilitate valve surgery and therefore have the potential to decrease the invasivness and to shorten the conventional procedure without compromise in term of excision of the diseased valve. This review summarizes the history and the current knowledge of sutureless valve technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aortic valve replacement using a tissue valve is controversial for patients younger than 60 years old. The long-term survival in this age group, the expected event rates during long-term follow-up, and valve-related complications are not clearly determined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atrioventricular conduction abnormalities (AVCA) may complicate transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). The aim of this study was to prospectively evaluate AVCA after TAVI and SAVR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To compare health-related quality of life (QoL) in patients undergoing transcatheter aortic valve implantation via transapical access (TA TAVI) with patients undergoing surgical aortic valve replacement (SAVR). METHODS One hundred and forty-four high-risk patients referred for aortic valve replacement underwent TAVI screening and were assigned to either TA TAVI (n = 51, age 79.7 ± 9.2 years, logistic EuroSCORE 26.5 ± 16.1%, 51% males) or SAVR (n = 93, age 81.1 ± 5.3 years, logistic EuroSCORE 12.1 ± 9.3%, 42% males) by the interdisciplinary heart team. QoL was assessed using the Short Form 36 (SF-36) Health Survey Questionnaire and the Hospital Anxiety and Depression Scale. Furthermore, current living conditions and the degree of independence at home were evaluated. RESULTS Patients undergoing TA TAVI were at higher risk as assessed by EuroSCORE (26.5 ± 16 vs. 12.1 ± 9, P < 0.001) and STS score (6.7 ± 4 vs. 4.4 ± 3, P < 0.001) compared with SAVR patients. At the 30-day follow-up, the rate of mortality was similar and amounted to 7.8% for TA TAVI and 7.5% for SAVR patients and raised to 25.5% in TA TAVI and 18.3% in SAVR patients after a follow-up period of 15 ± 10 months. Assessment of QoL revealed no differences in terms of anxiety and depression between TA TAVI and SAVR patients. The SF-36 mental health metascore was similar in both groups (65.6 ± 19 vs. 68.8 ± 22, P = 0.29), while a significant difference was observed in the physical health metascore (49.7 ± 21 vs. 62.0 ± 21, P = 0.015). After adjustment for baseline characteristics, this difference disappeared. However, every added point in the preoperative risk assessment with the STS score decreased the SF-36 physical health dimension by two raw points at the follow-up assessment. CONCLUSIONS Selected high-risk patients undergoing TAVI by using a transapical access achieve similar clinical outcomes and QoL compared with patients undergoing SAVR. Increased STS scores predict worse QoL outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to characterize aortic root dimensions of patients with aortic valve stenosis undergoing transcatheter aortic valve replacement (TAVR) and to evaluate sex differences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim of this study was to elucidate if postoperative neurocognitive function after biological aortic valve replacement (AVR) can be influenced by temperature management during cardiopulmonary bypass (CPB).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) offers a new treatment option for patients with aortic stenosis, but costs may play a decisive role in decision making. Current studies are evaluating TAVR in an intermediate-risk population. We assessed the in-hospital and 1-year follow-up costs of patients undergoing TAVR and surgical aortic valve replacement (SAVR) at intermediate operative risk and identified important cost components.