956 resultados para upper eyelid
Resumo:
Purpose: The cornea is known to be susceptible to forces exerted by eyelids. There have been previous attempts to quantify eyelid pressure but the reliability of the results is unclear. The purpose of this study was to develop a technique using piezoresistive pressure sensors to measure upper eyelid pressure on the cornea. Methods: The technique was based on the use of thin (0.18 mm) tactile piezoresistive pressure sensors, which generate a signal related to the applied pressure. A range of factors that influence the response of this pressure sensor were investigated along with the optimal method of placing the sensor in the eye. Results: Curvature of the pressure sensor was found to impart force, so the sensor needed to remain flat during measurements. A large rigid contact lens was designed to have a flat region to which the sensor was attached. To stabilise the contact lens during measurement, an apparatus was designed to hold and position the sensor and contact lens combination on the eye. A calibration system was designed to apply even pressure to the sensor when attached to the contact lens, so the raw digital output could be converted to actual pressure units. Conclusions: Several novel procedures were developed to use tactile sensors to measure eyelid pressure. The quantification of eyelid pressure has a number of applications including eyelid reconstructive surgery and the design of soft and rigid contact lenses.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Purpose: To describe spontaneous blink kinematics in Graves' upper eyelid retraction (UER).Methods: The magnetic search coil technique was used to record spontaneous blinks of 15 healthy subjects (aged 23-56 years, 15 eyelids) and 15 patients with Graves' UER (aged 22-62 years, 15 eyelids) during a 5-min period of video observation, and the signals were digitized at 200 Hz (12 bits). Overall, a total of 2,798 blinks were recorded for the controls and 1,860 for the patients. The distance between pupil center and upper eyelid margin in the primary position of gaze (MRD) was measured with the Image J software.Results: The blinking rate of patients was lower than that of control subjects, with a mean (+/-SEM) blinking rate (blinks/min) of 13.0 +/- 1.7 for patients and of 20.0 +/- 2.1 for the controls (t = 2.58, P = 0.016). There were no statistically significant differences in blink amplitude between controls (22.7 +/- 3.1 degrees) and Graves' patients (24.7 +/- 3.3 degrees). However, while only 22% of the blinks performed by controls were smaller than MRD, this rate was 78% for patients. In addition, in blinks larger than 25, patients showed lower down-phase velocity than controls.Conclusions: Patients with Graves' UER show reduced blinks rates and abnormal blink kinematics, which might be related to the development of exposure keratitis in this disease.
Resumo:
Objective: Assess the occurrence of secondary brow ptosis after upper lid blepharoplasty. Methods: Forty-five individuals (n90 brows) submitted to upper lid blepharoplasty, were assessed by means of a comparative analysis using pre- and post-operatively digital photographs, in the primary position of the eye. The images were processed using ImageJ software, transferred to a computer, to an electronic Microsoft Excel 2002® worksheet. Angular measurements were used, taking the lateral canthal angle of the brow, the most medial point of the brow, the medial canthal angle and the lateral canthal angle of the lid as anatomical reference points. When the outer angles were reduced or the inner angles increased after surgery this was considered a brow ptosis. Individuals who had undergone lid surgery associated with the eyebrow, previous eyebrow surgery and those with eyelid ptosis were excluded. The difference between the pre-operative and post-operative measurements were analyzed statistically using the Student's t-test for paired samples and the angular variation was compared with their corresponding contralateral sample using Wilcoxon's non-parametric test. Results: The measurements obtained after the blepharoplasty show significant variations from those before the surgery, indicating that the correction of redundant tissues in the brow accentuates the tendency of the eyebrow to move down. The alterations are more important in the lateral portion of the eyebrow and they occur bilaterally. Conclusion: The assessment of angular measurements obtained pre- and post-operatively showed that there are secondary changes in the position of the eyebrow as a result of upper eyelid blepharoplasty. © 2012 Informa Healthcare USA, Inc.
Resumo:
Purpose. We quantified the main sequence of spontaneous blinks in normal subjects and Graves' disease patients with upper eyelid retraction using a nonlinear and two linear models, and examined the variability of the main sequence estimated with standard linear regression for 10-minute periods of time. Methods. A total of 20 normal subjects and 12 patients had their spontaneous blinking measured with the magnetic search coil technique when watching a video during one hour. The main sequence was estimated with a power-law function, and with standard and trough the origin linear regressions. Repeated measurements ANOVA was used to test the mean sequence stability of 10-minute bins measured with standard linear regression. Results. In 95% of the sample the correlation coefficients of the main sequence ranged from 0.60 to 0.94. Homoscedasticity of the peak velocity was not verified in 20% of the subjects and 25% of the patients. The power-law function provided the best main sequence fitting for subjects and patients. The mean sequence of 10-minute bins measured with standard linear regression did not differ from the one-hour period value. For the entire period of observation and the slope obtained by standard linear regression, the main sequence of the patients was reduced significantly compared to the normal subjects. Conclusions. Standard linear regression is a valid and stable approximation for estimating the main sequence of spontaneous blinking. However, the basic assumptions of the linear regression model should be examined on an individual basis. The maximum velocity of large blinks is slower in Graves' disease patients than in normal subjects. © 2013 The Association for Research in Vision and Ophthalmology, Inc.
Resumo:
Purpose: One of the most common problems of the surgical management of Graves upper eyelid retraction is the occurrence of eyelid contour abnormalities. In the present study, the postoperative contour of a large sample of eyelids of patients with Graves orbitopathy was measured. Methods: The postoperative upper eyelid contour of 62 eyes of 43 patients with Graves orbitopathy was subjectively classified by 3 experienced surgeons in 3 categories: poor, fair, and good. The shape of the eyelid contours in each category was then measured with a recently developed custom-made software by measuring multiple midpupil eyelid distances each 15 degrees along the palpebral fissure. The upper eyelid contour of 60 normal subjects was also quantified as a control group. Results: The mean ratio between the sum of the lateral and medial midpupil eyelid distances (lateral/medial ratio) was 1.10 +/- 0.11 standard deviation in controls and 1.15 +/- 0.13 standard deviation in patients. Postoperatively, the mean midpupil eyelid distance at 90 degrees was 4.16 +/- 1.13 mm standard deviation. The distribution lateral/medial ratios of the eyelids judged as having good contours was similar to the distribution of the controls with a modal value centered on the interval between 1.0 and 1.10. The distribution of lateral/medial ratios of the eyelids judged as having poor contour was bimodal, with eyelids with low and high lateral/medial ratios. Low lateral/medial ratios occurred when there was a lateral overcorrection, giving the eyelid a flat or a medial ptosis appearance. High lateral/medial ratios were due to a central or medial overcorrection or a lateral peak maintenance. Conclusions: Postoperative upper eyelid contour abnormalities can be quantified by comparing the sum of multiple midpupil eyelid distances of the lateral and medial sectors of the eyelid. Low and high lateral/medial ratios are anomalous and judged as unpleasant. (Ophthal Plast Reconstr Surg 2012;28:429-433)
Resumo:
Purpose: To describe and present the results of a new surgical technique for patients with floppy eyelid syndrome, based on the medial upper eyelid stretching encountered in this condition. Methods: A case series of 24 patients with floppy eyelid syndrome who where found to have symptomatic predominately medial upper eyelid laxity was analyzed. The history, clinical features, histopathology, and outcome were reviewed after patients underwent medial upper eyelid shortening with or without upper eyelid skin reduction as the first surgical procedure. Results: Of the 24 patients, 18 were men (75%) with a mean age at referral of 56 years, having ocular discomfort and conjunctival irritation/papillary conjunctivitis as the main complaints at presentation. Obesity was present in 96% of cases, with lower eyelid laxityl/ectropion (50%) and upper eyelid eyelash ptosis (29%) in conjunction with the upper eyelid laxity. The affected side was related to sleeping habits or recurrent mechanical eyelid trauma. Histologic studies showed a nonspecific inflammatory cell infiltrate and loss of elastin with loose dermal connective tissue. After surgery, complete relief of ocular symptoms and good functional and cosmetic results were present in all cases after 18 months of follow-up. Conclusions: This new surgical approach is based on the presence of predominately medial upper laxity in patients with floppy eyelid syndrome. The excision of this stretched area stabilized the upper eyelid in an anatomic fashion, providing a good and stable long-term result. The possible mechanisms involved in the medial upper eyelid stretching are discussed.
Resumo:
Purpose To investigate static upper eyelid pressure and contact with the ocular surface in a group of young adult subjects. Methods Static upper eyelid pressure was measured for 11 subjects using a piezoresistive pressure sensor attached to a rigid contact lens. Measures of eyelid pressure were derived from an active pressure cell (1.14 mm square) beneath the central upper eyelid margin. To investigate the contact region between the upper eyelid and ocular surface, we used pressure sensitive paper and the lissamine-green staining of Marx’s line. These measures combined with the pressure sensor readings were used to derive estimates of eyelid pressure. Results The mean contact width between the eyelids and ocular surface estimated using pressure sensitive paper was 0.60 ± 0.16 mm, while the mean width of Marx’s line was 0.09 ± 0.02 mm. The mean central upper eyelid pressure was calculated to be 3.8 ± 0.7 mmHg (assuming that the whole pressure cell was loaded), 8.0 ± 3.4 mmHg (derived using the pressure sensitive paper imprint widths) and 55 ± 26 mmHg (based on contact widths equivalent to Marx’s line). Conclusions The pressure sensitive paper measurements suggest that a band of the eyelid margin, significantly larger than the anatomical zone of the eyelid margin known as Marx’s line, has primary contact with the ocular surface. Using these measurements as the contact between the eyelid margin and ocular surface, we believe that the mean pressure of 8.0 ± 3.4 mmHg is the most reliable estimate of static upper eyelid pressure.
Resumo:
The eyelids play an important role in lubricating and protecting the surface of the eye. Each blink serves to spread fresh tears, remove debris and replenish the smooth optical surface of the eye. Yet little is known about how the eyelids contact the ocular surface and what pressure distribution exists between the eyelids and cornea. As the principal refractive component of the eye, the cornea is a major element of the eye’s optics. The optical properties of the cornea are known to be susceptible to the pressure exerted by the eyelids. Abnormal eyelids, due to disease, have altered pressure on the ocular surface due to changes in the shape, thickness or position of the eyelids. Normal eyelids also cause corneal distortions that are most often noticed when they are resting closer to the corneal centre (for example during reading). There were many reports of monocular diplopia after reading due to corneal distortion, but prior to videokeratoscopes these localised changes could not be measured. This thesis has measured the influence of eyelid pressure on the cornea after short-term near tasks and techniques were developed to quantify eyelid pressure and its distribution. The profile of the wave-like eyelid-induced corneal changes and the refractive effects of these distortions were investigated. Corneal topography changes due to both the upper and lower eyelids were measured for four tasks involving two angles of vertical downward gaze (20° and 40°) and two near work tasks (reading and steady fixation). After examining the depth and shape of the corneal changes, conclusions were reached regarding the magnitude and distribution of upper and lower eyelid pressure for these task conditions. The degree of downward gaze appears to alter the upper eyelid pressure on the cornea, with deeper changes occurring after greater angles of downward gaze. Although the lower eyelid was further from the corneal centre in large angles of downward gaze, its effect on the cornea was greater than that of the upper eyelid. Eyelid tilt, curvature, and position were found to be influential in the magnitude of eyelid-induced corneal changes. Refractively these corneal changes are clinically and optically significant with mean spherical and astigmatic changes of about 0.25 D after only 15 minutes of downward gaze (40° reading and steady fixation conditions). Due to the magnitude of these changes, eyelid pressure in downward gaze offers a possible explanation for some of the day-to-day variation observed in refraction. Considering the magnitude of these changes and previous work on their regression, it is recommended that sustained tasks performed in downward gaze should be avoided for at least 30 minutes before corneal and refractive assessment requiring high accuracy. Novel procedures were developed to use a thin (0.17 mm) tactile piezoresistive pressure sensor mounted on a rigid contact lens to measure eyelid pressure. A hydrostatic calibration system was constructed to convert raw digital output of the sensors to actual pressure units. Conditioning the sensor prior to use regulated the measurement response and sensor output was found to stabilise about 10 seconds after loading. The influences of various external factors on sensor output were studied. While the sensor output drifted slightly over several hours, it was not significant over the measurement time of 30 seconds used for eyelid pressure, as long as the length of the calibration and measurement recordings were matched. The error associated with calibrating at room temperature but measuring at ocular surface temperature led to a very small overestimation of pressure. To optimally position the sensor-contact lens combination under the eyelid margin, an in vivo measurement apparatus was constructed. Using this system, eyelid pressure increases were observed when the upper eyelid was placed on the sensor and a significant increase was apparent when the eyelid pressure was increased by pulling the upper eyelid tighter against the eye. For a group of young adult subjects, upper eyelid pressure was measured using this piezoresistive sensor system. Three models of contact between the eyelid and ocular surface were used to calibrate the pressure readings. The first model assumed contact between the eyelid and pressure sensor over more than the pressure cell width of 1.14 mm. Using thin pressure sensitive carbon paper placed under the eyelid, a contact imprint was measured and this width used for the second model of contact. Lastly as Marx’s line has been implicated as the region of contact with the ocular surface, its width was measured and used as the region of contact for the third model. The mean eyelid pressures calculated using these three models for the group of young subjects were 3.8 ± 0.7 mmHg (whole cell), 8.0 ± 3.4 mmHg (imprint width) and 55 ± 26 mmHg (Marx’s line). The carbon imprints using Pressurex-micro confirmed previous suggestions that a band of the eyelid margin has primary contact with the ocular surface and provided the best estimate of the contact region and hence eyelid pressure. Although it is difficult to directly compare the results with previous eyelid pressure measurement attempts, the eyelid pressure calculated using this model was slightly higher than previous manometer measurements but showed good agreement with the eyelid force estimated using an eyelid tensiometer. The work described in this thesis has shown that the eyelids have a significant influence on corneal shape, even after short-term tasks (15 minutes). Instrumentation was developed using piezoresistive sensors to measure eyelid pressure. Measurements for the upper eyelid combined with estimates of the contact region between the cornea and the eyelid enabled quantification of the upper eyelid pressure for a group of young adult subjects. These techniques will allow further investigation of the interaction between the eyelids and the surface of the eye.
Resumo:
Small lesions located in the skin might be treated using the laser system. The purpose of this is to report the therapy of benign eyelid tumors using argon laser. Forty-four benign eyelid tumors were treated using argon blue-green laser with spot size of 500 μm, power from 1000 to 1200 mW and 0.3 second exposure time. The eyelid tumors were located mainly in the upper eyelid (65.9%) and the skin tag was the most frequent treated lesion (43.2%). The average number of laser shots to treat the lesions was 165. There was not observed any complication and all patients were satisfied with the results. The authors are considering the argon laser a benefit therapeutic method to treat benign tumors located in the eyelids.
Resumo:
A healthy human would be expected to show periodic blinks, making a brief closure of the eyelids. Most blinks are spontaneous, occurring regularly with no external stimulus. However a reflex blink can occur in response to external stimuli such as a bright light, a sudden loud noise, or an object approaching toward the eyes. A voluntary or forced blink is another type of blink in which the person deliberately closes the eyes and the lower eyelid raises to meet the upper eyelid. A complete blink, in which the upper eyelid touches the lower eyelid, contributes to the health of ocular surface by providing a fresh layer of tears as well as maintaining optical integrity by providing a smooth tear film over the cornea. The rate of blinking and its completeness vary depending on the task undertaken during blink assessment, the direction of gaze, the emotional state of the subjects and the method under which the blink was measured. It is also well known that wearing contact lenses (both rigid and soft lenses) can induce significant changes in blink rate and completeness. It is been established that efficient blinking plays an important role in ocular surface health during contact lens wear and for improving contact lens performance and comfort. Inefficient blinking during contact lens wear may be related to a low blink rate or incomplete blinking and can often be a reason for dry eye symptoms or ocular surface staining. It has previously been shown that upward gaze can affect blink rate, causing it to become faster. In the first experiment, it was decided to expand on previous studies in this area by examining the effect of various gaze directions (i.e. upward gaze, primary gaze, downward gaze and lateral gaze) as well as head angle (recumbent position) on normal subjects’ blink rate and completeness through the use of filming with a high-speed camera. The results of this experiment showed that as the open palpebral aperture (and exposed ocular surface area) increased from downward gaze to upward gaze, the number of blinks significantly increased (p<0.04). Also, the size of closed palpebral aperture significantly increased from downward gaze to upward gaze (p<0.005). A weak positive correlation (R² = 0.18) between the blink rate and ocular surface area was found in this study. Also, it was found that the subjects showed 81% complete blinks, 19% incomplete blinks and 2% of twitch blinks in primary gaze, consistent with previous studies. The difference in the percentage of incomplete blinks between upward gaze and downward gaze was significant (p<0.004), showing more incomplete blinks in upward gaze. The findings of this experiment suggest that while blink rate becomes slower in downward gaze, the completeness of blinking is typically better, thereby potentially reducing the risk of tear instability. On the other hand, in upward gaze while the completeness of blinking becomes worse, this is potentially offset by increased blink frequency. In addition, blink rate and completeness were not affected by lateral gaze or head angle, possibly because these conditions have similar size of the open palpebral aperture compared with primary gaze. In the second experiment, an investigation into the changes in blink rate and completeness was carried out in primary gaze and downward gaze with soft and rigid contact lenses in unadapted wearers. Not surprisingly, rigid lens wear caused a significant increase in the blink rate in both primary (p<0.001) and downward gaze (p<0.02). After fitting rigid contact lenses, the closed palpebral aperture (blink completeness) did not show any changes but the open palpebral aperture showed a significant narrowing (p<0.04). This might occur from the subjects’ attempt to avoid interaction between the upper eyelid and the edge of the lens to minimize discomfort. After applying topical anaesthetic eye drops in the eye fitted with rigid lenses, the increased blink rate dropped to values similar to that before lens insertion and the open palpebral aperture returned to baseline values, suggesting that corneal and/or lid margin sensitivity was mediating the increased blink rate and narrowed palpebral aperture. We also investigated the changes in the blink rate and completeness with soft contact lenses including a soft sphere, double slab-off toric design and periballast toric design. Soft contact lenses did not cause any significant changes in the blink rate, closed palpebral aperture, open palpebral aperture and the percentage of incomplete blinks in either primary gaze or downward gaze. After applying anaesthetic eye drops, the blink rate reduced in both primary gaze and downward gaze, however this difference was not statistically significant. The size of the closed palpebral aperture and open palpebral aperture did not show any significant changes after applying anaesthetic eye drops. However it should be noted that the effects of rigid and soft contact lenses that we observed in these studies were only the immediate reaction to contact lenses and in the longer term, it is likely that these responses will vary as the eye adapts to the presence of the lenses.
Resumo:
Purpose: To examine the symmetry of corneal changes following near work in the fellow eyes of non-amblyopic myopic anisometropes. Methods: Thirty-four non-amblyopic, myopic anisometropes (minimum 1 D spherical equivalent anisometropia) had corneal topography measured before and after a controlled near work task. Subjects were positioned in a headrest to minimise head movements and read continuous text on a computer monitor for 10 minutes at an angle of 25 degrees downward gaze and an accommodation demand of 2.5 D. Measures of the morphology of the palpebral aperture during primary and downward gaze were also obtained. Results: The more and less myopic eyes exhibited a high degree of interocular symmetry for measures of palpebral aperture morphology during both primary and downward gaze. Following the near work task, fellow eyes also displayed a symmetrical change in superior corneal topography (hyperopic defocus) which correlated with the position of the upper eyelid during downward gaze. Greater changes in the spherical corneal power vector (M) following reading were associated with narrower palpebral aperture during downward gaze (p = 0.07 for more myopic and p = 0.03 for less myopic eyes). A significantly greater change in J0 (an increase in against the rule astigmatism) was observed in the more myopic eyes (-0.04 ± 0.04 D) compared to the less myopic eyes (-0.02 ± 0.06 D) over a 6 mm corneal diameter (p = 0.01). Conclusions: Changes in corneal topography following near work are highly symmetrical between the fellow eyes of myopic anisometropes due to the interocular symmetry of the palpebral aperture. However, the more myopic eye exhibits changes in corneal astigmatism of greater magnitude compared to the less myopic eye.
Resumo:
O mucocelo é uma lesão quística, benigna, expansiva dos seios perinasais. A sobreinfecção deste, designada de mucopiocelo, pode levar a um período de crescimento rápido, com maior risco de complicações. Relata-se o caso clínico de uma doente do sexo feminino, 59 anos, que recorreu ao Serviço de Urgência após crise inaugural de convulsão tónico-clónica generalizada, com queixas de aumento de volume periorbitário direito e febre desde há 1 semana. Apresentava à direita celulite orbitária e proptose ínfero-externa, com área de flutuação na parte medial da pálpebra superior, oftalmoplegia e quemose do olho direito acompanhada de rinorreia mucopurulenta. Realizou TC que demonstrou volumoso abcesso subperiosteal direito, ao nível da parede medial da órbita, tendo como ponto de partida aparente as células etmoidais anteriores homolaterais e seio frontal direito. Colocou-se a hipótese de mucopiocelo fronto-etmoidal. Foi submetida a drenagem de urgência do abcesso e a cirurgia endoscópica nasal com marsupialização da lesão fronto-etmoidal. Verificou-se resolução completa do quadro clínico. Apesar de consideradas lesões benignas, os mucocelos, apresentam potencial destrutivo, principalmente se infectados, necessitando, por vezes, de intervenção cirúrgica de urgência. A abordagem endoscópica destas lesões reafirma-se como tratamento de eleição.
Revisión sistemática de la literatura: efecto de los rellenos inyectables en la región periorbitaria
Resumo:
Introducción: El conocimiento actual de la fisiopatología del envejecimiento periorbitario justifica la aplicación de materiales de relleno inyectables, dado que se enfocan en la restauración del volumen perdido en esta zona, convirtiéndose en una excelente alternativa a procedimientos quirúrgicos que remueven el tejido excedente. Sin embargo los efectos y la seguridad de esta naciente tendencia terapéutica aún no se sustentan en una sólida base científica. El objetivo de esta revisión es identificar el material de relleno inyectable más adecuado para el manejo de los defectos volumétricos estéticos de la región periorbitaria. Metodología: Se realizó una búsqueda exhaustiva de los artículos indexados publicados del 1º de enero de 2.000 al 30 de septiembre de 2.013, en diversas bases de datos electrónicas, se seleccionaron catorce publicaciones, se extrajo la información referente a datos demográficos, la intervención, el seguimiento y los desenlaces y se realizó un análisis de 14 estudios que cumplieron los criterios. Resultados: Todos los artículos incluidos poseían un bajo nivel de evidencia y del grado de recomendación. Todos los materiales de relleno se asociaron a altos niveles de satisfacción para el paciente, adecuada mejoría de la apariencia estética y similares efectos colaterales, el ácido hialurónico fue el material de relleno inyectable más utilizado en la región periorbitaria. Discusión: Los materiales de relleno inyectable mejoran los defectos volumétricos estéticos de la región periorbitaria pero es necesaria mayor evidencia para determinar el tipo relleno más apropiado para esta condición.