925 resultados para turf visual quality


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shipping list no.: 92-0122-P.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The tear film, cornea and lens dictate the refractive power of the eye and the retinal image quality is principally defined by diffraction, whole eye wavefront error, scatter, and chromatic aberration. Diffraction and wave aberration are fundamentally pupil diameter dependent; however scatter can be induced by refractive surgery and in the normal ageing eye becomes an increasingly important factor defining retinal image quality. The component of visual quality most affected by the tear film, refractive surgery and multifocal contact and intraocular lenses is the wave aberration of the eye. This body of work demonstrates the effects of each of these anomalies on the visual quality of the eye. When assessing normal or borderline self-diagnosed dry eye subjects using aberrometry, combining lubricating eye drops and spray does not offer any benefit over individual products. However, subjects perceive a difference in comfort for all interventions after one hour. Total higher order aberrations increase after laser assisted sub-epithelial keratectomy performed using a solid-state laser on myopes, but this causes no significant decrease in contrast sensitivity or increase in glare disability. Mean sensitivity and reliability indices for perimetry were comparable to pre-surgery results. Multifocal contact lenses and intraocular lenses are designed to maximise vision when the patient is binocular, so any evaluation of the eyes individually is confounded by reduced individual visual acuity and visual quality. Different designs of aspheric multifocal contact lenses do not provide the same level of visual quality. Multifocal contact lenses adversely affect mean deviation values for perimetry and this should be considered when screening individuals with multifocal contact or intraocular lenses. Photographic image quality obtained through a multifocal contact or intraocular lens appears to be unchanged. Future work should evaluate the effect of these anomalies in combination; with the aim of providing the best visual quality possible and supplying normative data for screening purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本研究采用室外盆栽试验,模拟运动场坪床结构,研究不同氮肥种类、不同施氮频率、施氮和降雨时间间隔对草地早熟禾草坪质量、草坪生长和无机氮淋洗的影响,并探讨在北京地区气候条件下,草坪在不同氮肥管理措施下的氮素去向及环境风险。主要结论如下: 1. 氮肥种类对草坪质量和草坪生长有显著影响。试验前期(春季),草坪颜色和密度质量、草坪草生长速度和草屑全氮含量的排序为尿素 > CU3M(自研包膜尿素)> IBDU(进口缓释肥),而试验后期(秋季)则为CU3M = IBDU > 尿素。草坪合格颜色质量持续时间和成坪速度的排序为尿素 > CU3M > IBDU。在新建草坪选择缓释肥进行早春施肥时,应混施一定比例的速效肥。 2. 施氮频率对草坪外观质量评分、草坪生长速度、草屑总生物量、草屑全氮含量和根系分布状况有显著影响。U6处理的草坪合格颜色质量持续时间最长,增加施氮频率没有降低新建草坪生长速度和草屑全氮含量的波动幅度。 3. 夏季(6~8月)渗漏液体积占全年的比例最高,为75.0%~82.4%。新建草坪初期的淋洗风险较大,渗漏液硝态氮浓度在第1次超过10 mg N•L-1,尿素分6次施用可降低这次的渗漏液硝态氮浓度。在合理施氮量内,草坪成熟后的无机氮淋洗量很小,且草坪对雨水中的无机氮有吸收和过滤作用。 4. 春季施用氮肥的吸收利用率为48.0%~72.6%,草屑吸收量最高,占38.5%~48.7%,地上部吸收量占19.6%~22.1%,根系吸收量在7.3%以下。施肥处理的无机氮淋洗损失量仅为0.23~0.42 g N•m-2,与CK无显著差异,草地早熟禾12 g N•m-2的年施氮量对环境的风险很小。 5. 初秋施氮5 g N•m-2,可以保持草地早熟禾秋季的良好颜色和密度质量,草坪草氮素吸收利用率高达87.4%~99.7%,其中草屑带走量占24.3%~34.2%,地上部吸收量占43.3%~59.6%,根系吸收量占14.2%~19.1%。 6. 施氮和模拟降雨的时间间隔对渗漏液硝态氮浓度有显著影响,间隔6 d和9 d模拟降雨后的渗漏液硝态氮浓度最高,显著高于间隔3 d和12 d模拟降雨的结果。初秋合理施氮的渗漏液硝态氮浓度在1.0 mg N•L-1 以下,环境风险较小。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aims to contribute to the reliability and integrity of perceptual systems of unmanned ground vehicles (UGV). A method is proposed to evaluate the quality of sensor data prior to its use in a perception system by utilising a quality metric applied to heterogeneous sensor data such as visual and infrared camera images. The concept is illustrated specifically with sensor data that is evaluated prior to the use of the data in a standard SIFT feature extraction and matching technique. The method is then evaluated using various experimental data sets that were collected from a UGV in challenging environmental conditions, represented by the presence of airborne dust and smoke. In the first series of experiments, a motionless vehicle is observing a ’reference’ scene, then the method is extended to the case of a moving vehicle by compensating for its motion. This paper shows that it is possible to anticipate degradation of a perception algorithm by evaluating the input data prior to any actual execution of the algorithm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

he inclusion of environmental care data in the decision-making process should be based on the results obtained after scienti?cally evaluating different environmental variables. Herein, a European landscape geographic model is presented. This landscape map would allow the environmental care variable ?visual landscape?, along with other information related to vegetation, geology, soils, cultural variables, etc., to be integrated into the planning process. The methodology used is not new since it has already been tested in Spain by the authors. Nevertheless, the model was adapted to cope with the much more extensive territory of the European Union. This meant dealing with computational dif?culties, and a lack of information. The result of this work is a raster map (100 m cell size) that evaluates landscape quality in Europe by dividing the area into seven visual quality classes. This is a practical tool for territorial development that will facilitate the environmental assessment of plans, such as infrastructure plans, within a strategic pan-European framework.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Retinal image quality is commonly analyzed through parameters inherited from instrumental optics. These parameters are defined for ‘good optics’ so they are hard to translate into visual quality metrics. Instead of using point or artificial functions, we propose a quality index that takes into account properties of natural images. These images usually show strong local correlations that help to interpret the image. Our aim is to derive an objective index that quantifies the quality of vision by taking into account the local structure of the scene, instead of focusing on a particular aberration. As we show, this index highly correlates with visual acuity and allows inter-comparison of natural images around the retina. The usefulness of the index is proven through the analysis of real eyes before and after undergoing corneal surgery, which usually are hard to analyze with standard metrics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The international focus on embracing daylighting for energy efficient lighting purposes and the corporate sector’s indulgence in the perception of workplace and work practice “transparency” has spurned an increase in highly glazed commercial buildings. This in turn has renewed issues of visual comfort and daylight-derived glare for occupants. In order to ascertain evidence, or predict risk, of these events; appraisals of these complex visual environments require detailed information on the luminances present in an occupant’s field of view. Conventional luminance meters are an expensive and time consuming method of achieving these results. To create a luminance map of an occupant’s visual field using such a meter requires too many individual measurements to be a practical measurement technique. The application of digital cameras as luminance measurement devices has solved this problem. With high dynamic range imaging, a single digital image can be created to provide luminances on a pixel-by-pixel level within the broad field of view afforded by a fish-eye lens: virtually replicating an occupant’s visual field and providing rapid yet detailed luminance information for the entire scene. With proper calibration, relatively inexpensive digital cameras can be successfully applied to the task of luminance measurements, placing them in the realm of tools that any lighting professional should own. This paper discusses how a digital camera can become a luminance measurement device and then presents an analysis of results obtained from post occupancy measurements from building assessments conducted by the Mobile Architecture Built Environment Laboratory (MABEL) project. This discussion leads to the important realisation that the placement of such tools in the hands of lighting professionals internationally will provide new opportunities for the lighting community in terms of research on critical issues in lighting such as daylight glare and visual quality and comfort.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper, we present a machine learning approach to measure the visual quality of JPEG-coded images. The features for predicting the perceived image quality are extracted by considering key human visual sensitivity (HVS) factors such as edge amplitude, edge length, background activity and background luminance. Image quality assessment involves estimating the functional relationship between HVS features and subjective test scores. The quality of the compressed images are obtained without referring to their original images ('No Reference' metric). Here, the problem of quality estimation is transformed to a classification problem and solved using extreme learning machine (ELM) algorithm. In ELM, the input weights and the bias values are randomly chosen and the output weights are analytically calculated. The generalization performance of the ELM algorithm for classification problems with imbalance in the number of samples per quality class depends critically on the input weights and the bias values. Hence, we propose two schemes, namely the k-fold selection scheme (KS-ELM) and the real-coded genetic algorithm (RCGA-ELM) to select the input weights and the bias values such that the generalization performance of the classifier is a maximum. Results indicate that the proposed schemes significantly improve the performance of ELM classifier under imbalance condition for image quality assessment. The experimental results prove that the estimated visual quality of the proposed RCGA-ELM emulates the mean opinion score very well. The experimental results are compared with the existing JPEG no-reference image quality metric and full-reference structural similarity image quality metric.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The overall aim of this dissertation was to study the public's preferences for forest regeneration fellings and field afforestations, as well as to find out the relations of these preferences to landscape management instructions, to ecological healthiness, and to the contemporary theories for predicting landscape preferences. This dissertation includes four case studies in Finland, each based on the visualization of management options and surveys. Guidelines for improving the visual quality of forest regeneration and field afforestation are given based on the case studies. The results show that forest regeneration can be connected to positive images and memories when the regeneration area is small and some time has passed since the felling. Preferences may not depend only on the management alternative itself but also on the viewing distance, viewing point, and the scene in which the management options are implemented. The current Finnish forest landscape management guidelines as well as the ecological healthiness of the studied options are to a large extent compatible with the public's preferences. However, there are some discrepancies. For example, the landscape management instructions as well as ecological hypotheses suggest that the retention trees need to be left in groups, whereas people usually prefer individually located retention trees to those trees in groups. Information and psycho-evolutionary theories provide some possible explanations for people's preferences for forest regeneration and field afforestation, but the results cannot be consistently explained by these theories. The preferences of the different stakeholder groups were very similar. However, the preference ratings of the groups that make their living from forest - forest owners and forest professionals - slightly differed from those of the others. These results provide support for the assumptions that preferences are largely consistent at least within one nation, but that knowledge and a reference group may also influence preferences.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose
To evaluate the impact of the position of an asymmetric multifocal near segment on visual quality.

Setting
Cathedral Eye Clinic, Belfast, United Kingdom.

Design
Retrospective comparative case series.

Methods
Data from consecutive patients who had bilateral implantation of the Lentis Mplus LS-312 multifocal intraocular lens were divided into 2 groups. One group received inferonasal near-segment placement and the other, superotemporal near-segment placement. A +3.00 diopter (D) reading addition (add) was used in all eyes. The main outcome measures included uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), contrast sensitivity, and quality of vision. Follow-up was 3 months.

Results
Patients ranged in age from 43 to 76 years. The inferonasal group comprised 80 eyes (40 patients) and the superotemporal group, 76 eyes (38 patients). The mean 3-month spherical equivalent was −0.11 D ± 0.49 (SD) in the inferonasal group and −0.18 ± 0.46 D in the superotemporal group. The mean postoperative UDVA was 0.14 ± 0.10 logMAR and 0.18 ± 0.15 logMAR, respectively. The mean monocular UNVA was 0.21 ± 0.14 logRAD and 0.24 ± 0.13 logRAD, respectively. No significant differences were observed in the higher-order aberrations, total Strehl ratio (point-spread function), or modulation transfer function between the groups. Dysphotopic symptoms measured with a validated quality-of-vision questionnaire were not significantly different between groups.

Conclusion
Positioning of the near add did not significantly affect objective or subjective visual function parameters.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Rapid developments in display technologies, digital printing, imaging sensors, image processing and image transmission are providing new possibilities for creating and conveying visual content. In an age in which images and video are ubiquitous and where mobile, satellite, and three-dimensional (3-D) imaging have become ordinary experiences, quantification of the performance of modern imaging systems requires appropriate approaches. At the end of the imaging chain, a human observer must decide whether images and video are of a satisfactory visual quality. Hence the measurement and modeling of perceived image quality is of crucial importance, not only in visual arts and commercial applications but also in scientific and entertainment environments. Advances in our understanding of the human visual system offer new possibilities for creating visually superior imaging systems and promise more accurate modeling of image quality. As a result, there is a profusion of new research on imaging performance and perceived quality.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The quality of fish products is indispensably linked to the freshness of the raw material modulated by appropriate manipulation and storage conditions, specially the storage temperature after catch. The purpose of the research presented in this thesis, which was largely conducted in the context of a research project funded by Italian Ministry of Agricultural, Food and Forestry Policies (MIPAAF), concerned the evaluation of the freshness of farmed and wild fish species, in relation to different storage conditions, under ice (0°C) or at refrigeration temperature (4°C). Several specimens of different species, bogue (Boops boops), red mullet (Mullus barbatus), sea bream (Sparus aurata) and sea bass (Dicentrarchus labrax), during storage, under the different temperature conditions adopted, have been examined. The assessed control parameters were physical (texture, through the use of a dynamometer; visual quality using a computer vision system (CVS)), chemical (through footprint metabolomics 1H-NMR) and sensory (Quality Index Method (QIM). Microbiological determinations were also carried out on the species of hake (Merluccius merluccius). In general obtained results confirmed that the temperature of manipulation/conservation is a key factor in maintaining fish freshness. NMR spectroscopy showed to be able to quantify and evaluate the kinetics for unselected compounds during fish degradation, even a posteriori. This can be suitable for the development of new parameters related to quality and freshness. The development of physical methods, particularly the image analysis performed by computer vision system (CVS), for the evaluation of fish degradation, is very promising. Among CVS parameters, skin colour, presence and distribution of gill mucus, and eye shape modification evidenced a high sensibility for the estimation of fish quality loss, as a function of the adopted storage conditions. Particularly the eye concavity index detected on fish eye showed a high positive correlation with total QIM score.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Métrica de calidad de video de alta definición construida a partir de ratios de referencia completa. La medida de calidad de video, en inglés Visual Quality Assessment (VQA), es uno de los mayores retos por solucionar en el entorno multimedia. La calidad de vídeo tiene un impacto altísimo en la percepción del usuario final (consumidor) de los servicios sustentados en la provisión de contenidos multimedia y, por tanto, factor clave en la valoración del nuevo paradigma denominado Calidad de la Experiencia, en inglés Quality of Experience (QoE). Los modelos de medida de calidad de vídeo se pueden agrupar en varias ramas según la base técnica que sustenta el sistema de medida, destacando en importancia los que emplean modelos psicovisuales orientados a reproducir las características del sistema visual humano, en inglés Human Visual System, del que toman sus siglas HVS, y los que, por el contrario, optan por una aproximación ingenieril en la que el cálculo de calidad está basado en la extracción de parámetros intrínsecos de la imagen y su comparación. A pesar de los avances recogidos en este campo en los últimos años, la investigación en métricas de calidad de vídeo, tanto en presencia de referencia (los modelos denominados de referencia completa), como en presencia de parte de ella (modelos de referencia reducida) e incluso los que trabajan en ausencia de la misma (denominados sin referencia), tiene un amplio camino de mejora y objetivos por alcanzar. Dentro de ellos, la medida de señales de alta definición, especialmente las utilizadas en las primeras etapas de la cadena de valor que son de muy alta calidad, son de especial interés por su influencia en la calidad final del servicio y no existen modelos fiables de medida en la actualidad. Esta tesis doctoral presenta un modelo de medida de calidad de referencia completa que hemos llamado PARMENIA (PArallel Ratios MEtric from iNtrInsic features Analysis), basado en la ponderación de cuatro ratios de calidad calculados a partir de características intrínsecas de la imagen. Son: El Ratio de Fidelidad, calculado mediante el gradiente morfológico o gradiente de Beucher. El Ratio de Similitud Visual, calculado mediante los puntos visualmente significativos de la imagen a través de filtrados locales de contraste. El Ratio de Nitidez, que procede de la extracción del estadístico de textura de Haralick contraste. El Ratio de Complejidad, obtenido de la definición de homogeneidad del conjunto de estadísticos de textura de Haralick PARMENIA presenta como novedad la utilización de la morfología matemática y estadísticos de Haralick como base de una métrica de medida de calidad, pues esas técnicas han estado tradicionalmente más ligadas a la teledetección y la segmentación de objetos. Además, la aproximación de la métrica como un conjunto ponderado de ratios es igualmente novedosa debido a que se alimenta de modelos de similitud estructural y otros más clásicos, basados en la perceptibilidad del error generado por la degradación de la señal asociada a la compresión. PARMENIA presenta resultados con una altísima correlación con las valoraciones MOS procedentes de las pruebas subjetivas a usuarios que se han realizado para la validación de la misma. El corpus de trabajo seleccionado procede de conjuntos de secuencias validados internacionalmente, de modo que los resultados aportados sean de la máxima calidad y el máximo rigor posible. La metodología de trabajo seguida ha consistido en la generación de un conjunto de secuencias de prueba de distintas calidades a través de la codificación con distintos escalones de cuantificación, la obtención de las valoraciones subjetivas de las mismas a través de pruebas subjetivas de calidad (basadas en la recomendación de la Unión Internacional de Telecomunicaciones BT.500), y la validación mediante el cálculo de la correlación de PARMENIA con estos valores subjetivos, cuantificada a través del coeficiente de correlación de Pearson. Una vez realizada la validación de los ratios y optimizada su influencia en la medida final y su alta correlación con la percepción, se ha realizado una segunda revisión sobre secuencias del hdtv test dataset 1 del Grupo de Expertos de Calidad de Vídeo (VQEG, Video Quality Expert Group) mostrando los resultados obtenidos sus claras ventajas. Abstract Visual Quality Assessment has been so far one of the most intriguing challenges on the media environment. Progressive evolution towards higher resolutions while increasing the quality needed (e.g. high definition and better image quality) aims to redefine models for quality measuring. Given the growing interest in multimedia services delivery, perceptual quality measurement has become a very active area of research. First, in this work, a classification of objective video quality metrics based on their underlying methodologies and approaches for measuring video quality has been introduced to sum up the state of the art. Then, this doctoral thesis describes an enhanced solution for full reference objective quality measurement based on mathematical morphology, texture features and visual similarity information that provides a normalized metric that we have called PARMENIA (PArallel Ratios MEtric from iNtrInsic features Analysis), with a high correlated MOS score. The PARMENIA metric is based on the pooling of different quality ratios that are obtained from three different approaches: Beucher’s gradient, local contrast filtering, and contrast and homogeneity Haralick’s texture features. The metric performance is excellent, and improves the current state of the art by providing a wide dynamic range that make easier to discriminate between very close quality coded sequences, especially for very high bit rates whose quality, currently, is transparent for quality metrics. PARMENIA introduces a degree of novelty against other working metrics: on the one hand, exploits the structural information variation to build the metric’s kernel, but complements the measure with texture information and a ratio of visual meaningful points that is closer to typical error sensitivity based approaches. We would like to point out that PARMENIA approach is the only metric built upon full reference ratios, and using mathematical morphology and texture features (typically used in segmentation) for quality assessment. On the other hand, it gets results with a wide dynamic range that allows measuring the quality of high definition sequences from bit rates of hundreds of Megabits (Mbps) down to typical distribution rates (5-6 Mbps), even streaming rates (1- 2 Mbps). Thus, a direct correlation between PARMENIA and MOS scores are easily constructed. PARMENIA may further enhance the number of available choices in objective quality measurement, especially for very high quality HD materials. All this results come from validation that has been achieved through internationally validated datasets on which subjective tests based on ITU-T BT.500 methodology have been carried out. Pearson correlation coefficient has been calculated to verify the accuracy of PARMENIA and its reliability.