996 resultados para topography measurement
Resumo:
Topography of a granite surface has an effect on the vertical positioning of a wafer stage in a lithographic tool, when the wafer stage moves on the granite. The inaccurate measurement of the topography results in a bad leveling and focusing performance. In this paper, an in situ method to measure the topography of a granite surface with high accuracy is present. In this method, a high-order polynomial is set up to express the topography of the granite surface. Two double-frequency laser interferometers are used to measure the tilts of the wafer stage in the X- and Y-directions. From the sampling tilts information, the coefficients of the high-order polynomial can be obtained by a special algorithm. Experiment results shows that the measurement reproducibility of the method is better than 10 nm. (c) 2006 Elsevier GmbH. All rights reserved.
Resumo:
PURPOSE. This study was conducted to determine the magnitude of pupil center shift between the illumination conditions provided by corneal topography measurement (photopic illuminance) and by Hartmann-Shack aberrometry (mesopic illuminance) and to investigate the importance of this shift when calculating corneal aberrations and for the success of wavefront-guided surgical procedures. METHODS. Sixty-two subjects with emmetropia underwent corneal topography and Hartmann-Shack aberrometry. Corneal limbus and pupil edges were detected, and the differences between their respective centers were determined for both procedures. Corneal aberrations were calculated using the pupil centers for corneal topography and for Hartmann-Shack aberrometry. Bland-Altmann plots and paired t-tests were used to analyze the differences between corneal aberrations referenced to the two pupil centers. RESULTS. The mean magnitude (modulus) of the displacement of the pupil with the change of the illumination conditions was 0.21 ± 0.11 mm. The effect of this pupillary shift was manifest for coma corneal aberrations for 5-mm pupils, but the two sets of aberrations calculated with the two pupil positions were not significantly different. Sixty-eight percent of the population had differences in coma smaller than 0.05 µm, and only 4% had differences larger than 0.1 µm. Pupil displacement was not large enough to significantly affect other higher-order Zernike modes. CONCLUSIONS. Estimated corneal aberrations changed slightly between photopic and mesopic illumination conditions given by corneal topography and Hartmann-Shack aberrometry. However, this systematic pupil shift, according to the published tolerances ranges, is enough to deteriorate the optical quality below the theoretically predicted diffraction limit of wavefront-guided corneal surgery.
Resumo:
The value of the lateral bending test is important in the assessment of spinal curve mobility and prediction of surgical outcome in the treatment of adolescent idiopathic scoliosis (AIS). However, radiographic bending tests are unable to assess the reducibility of trunk asymmetry. This study aims to exploit surface topography measurement in order to evaluate the changes in shape of the trunk (a) between bending and neutral standing positions, and (b) between standing pre- and post-operative visits, in a cohort of adolescents with AIS having undergone surgical correction; and to correlate the differences measured in cases (a) and (b). Our cohort includes 13 patients with right thoracic AIS. Each patient had their 3D trunk surface digitized with a multi-head InSpeck system in standing posture (at the pre-op and post-op visits) and in maximum voluntary right and left bending (at the pre-op visit). We developed a novel trunk shape analysis method which produces a set of inclined trunk cross-sections allowing comparison between different postures. Two asymmetry indices, trunk rotation (TR) and back surface rotation (BSR), were computed in all cases and a statistical analysis was performed. Our correlation study (Pearson test) showed fair correlations in most cases between the changes in side-bending and those post-surgery, with the strongest relationship (p-value < 0.01) when combining the TR measurements from both bendings. These results provide evidence that the bending test can be used to assess trunk asymmetry reducibility. The proposed approach could provide a non-invasive trunk asymmetry reducibility test for routine clinical use in AIS surgery planning.
Resumo:
The planning of refractive surgical interventions is a challenging task. Numerical modeling has been proposed as a solution to support surgical intervention and predict the visual acuity, but validation on patient specific intervention is missing. The purpose of this study was to validate the numerical predictions of the post-operative corneal topography induced by the incisions required for cataract surgery. The corneal topography of 13 patients was assessed preoperatively and postoperatively (1-day and 30-day follow-up) with a Pentacam tomography device. The preoperatively acquired geometric corneal topography – anterior, posterior and pachymetry data – was used to build patient-specific finite element models. For each patient, the effects of the cataract incisions were simulated numerically and the resulting corneal surfaces were compared to the clinical postoperative measurements at one day and at 30-days follow up. Results showed that the model was able to reproduce experimental measurements with an error on the surgically induced sphere of 0.38D one day postoperatively and 0.19D 30 days postoperatively. The standard deviation of the surgically induced cylinder was 0.54D at the first postoperative day and 0.38D 30 days postoperatively. The prediction errors in surface elevation and curvature were below the topography measurement device accuracy of ±5μm and ±0.25D after the 30-day follow-up. The results showed that finite element simulations of corneal biomechanics are able to predict post cataract surgery within topography measurement device accuracy. We can conclude that the numerical simulation can become a valuable tool to plan corneal incisions in cataract surgery and other ophthalmosurgical procedures in order to optimize patients' refractive outcome and visual function.
Resumo:
It is well known in the scientific community that some remote sensing instruments assume that sample volumes present homogeneous conditions within a defined meteorological profile. At complex topographic sites and under extreme meteorological conditions, this assumption may be fallible depending on the site, and it is more likely to fail in the lower layers of the atmosphere. This piece of work tests the homogeneity of the wind field over a boundary layer wind profiler radar located in complex terrain on the coast under different meteorological conditions. The results reveal the qualitative importance of being aware of deviations in this homogeneity assumption and evaluate its effect on the final product. Patterns of behavior in data have been identified in order to simplify the analysis of the complex signal registered. The quality information obtained from the homogeneity study under different meteorological conditions provides useful indicators for the best alternatives the system can offer to build wind profiles. Finally, the results are also to be considered in order to integrate them in a quality algorithm implemented at the product level.
Resumo:
It is well known in the scientific community that some remote sensing instruments assume that sample volumes present homogeneous conditions within a defined meteorological profile. At complex topographic sites and under extreme meteorological conditions, this assumption may be fallible depending on the site, and it is more likely to fail in the lower layers of the atmosphere. This piece of work tests the homogeneity of the wind field over a boundary layer wind profiler radar located in complex terrain on the coast under different meteorological conditions. The results reveal the qualitative importance of being aware of deviations in this homogeneity assumption and evaluate its effect on the final product. Patterns of behavior in data have been identified in order to simplify the analysis of the complex signal registered. The quality information obtained from the homogeneity study under different meteorological conditions provides useful indicators for the best alternatives the system can offer to build wind profiles. Finally, the results are also to be considered in order to integrate them in a quality algorithm implemented at the product level.
Resumo:
The design and fabrication of a novel 2-scale topography dry electrode using macro and micro needles is presented. The macro needles enable biopotential measurements on hairy skin, the function of the micro needles is to decrease the electrode impedance even further by penetrating the outer skin layer. Also, a fast and reliable impedance characterization protocol is described. Based on this impedance measurement protocol, a comparison study is made between our dry electrode, 3 other commercial dry electrodes and a standard wet gel electrode. Promising results are already obtained with our electrodes which do not have skin piercing micro needles. For the proposed electrodes, three different conductive coatings (Ag/AgCl/Au) are compared. AgCl is found to be slightly better than Ag as coating material, while our Au coated electrodes have the highest impedance.
Resumo:
Quantifying the topography of rivers and their associated bedforms has been a fundamental concern of fluvial geomorphology for decades. Such data, acquired at high temporal and spatial resolutions, are increasingly in demand for process-oriented investigations of flow hydraulics, sediment dynamics and in-stream habitat. In these riverine environments, the most challenging region for topographic measurement is the wetted, submerged channel. Generally, dry bed topography and submerged bathymetry are measured using different methods and technology. This adds to the costs, logistical challenges and data processing requirements of comprehensive river surveys. However, some technologies are capable of measuring the submerged topography. Through-water photogrammetry and bathymetric LiDAR are capable of reasonably accurate measurements of channel beds in clear water. Whilst the cost of bathymetric LiDAR remains high and its resolution relatively coarse, the recent developments in photogrammetry using Structure from Motion (SfM) algorithms promise a fundamental shift in the accessibility of topographic data for a wide range of settings. Here we present results demonstrating the potential of so called SfM-photogrammetry for quantifying both exposed and submerged fluvial topography at the mesohabitat scale. We show that imagery acquired from a rotary-winged Unmanned Aerial System (UAS) can be processed in order to produce digital elevation models (DEMs) with hyperspatial resolutions (c. 0.02 m) for two different river systems over channel lengths of 50-100 m. Errors in submerged areas range from 0.016 m to 0.089 m, which can be reduced to between 0.008 m and 0.053 m with the application of a simple refraction correction. This work therefore demonstrates the potential of UAS platforms and SfM-photogrammetry as a single technique for surveying fluvial topography at the mesoscale (defined as lengths of channel from c.10 m to a few hundred metres). This article is protected by copyright. All rights reserved.
Resumo:
STUDY DESIGN: Concurrent validity between postural indices obtained from digital photographs (two-dimensional [2D]), surface topography imaging (three-dimensional [3D]), and radiographs. OBJECTIVE: To assess the validity of a quantitative clinical postural assessment tool of the trunk based on photographs (2D) as compared to a surface topography system (3D) as well as indices calculated from radiographs. SUMMARY OF BACKGROUND DATA: To monitor progression of scoliosis or change in posture over time in young persons with idiopathic scoliosis (IS), noninvasive and nonionizing methods are recommended. In a clinical setting, posture can be quite easily assessed by calculating key postural indices from photographs. METHODS: Quantitative postural indices of 70 subjects aged 10 to 20 years old with IS (Cobb angle, 15 degrees -60 degrees) were measured from photographs and from 3D trunk surface images taken in the standing position. Shoulder, scapula, trunk list, pelvis, scoliosis, and waist angles indices were calculated with specially designed software. Frontal and sagittal Cobb angles and trunk list were also calculated on radiographs. The Pearson correlation coefficients (r) was used to estimate concurrent validity of the 2D clinical postural tool of the trunk with indices extracted from the 3D system and with those obtained from radiographs. RESULTS: The correlation between 2D and 3D indices was good to excellent for shoulder, pelvis, trunk list, and thoracic scoliosis (0.81>r<0.97; P<0.01) but fair to moderate for thoracic kyphosis, lumbar lordosis, and thoracolumbar or lumbar scoliosis (0.30>r<0.56; P<0.05). The correlation between 2D and radiograph spinal indices was fair to good (-0.33 to -0.80 with Cobb angles and 0.76 for trunk list; P<0.05). CONCLUSION: This tool will facilitate clinical practice by monitoring trunk posture among persons with IS. Further, it may contribute to a reduction in the use of radiographs to monitor scoliosis progression.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Os dados sísmicos terrestres são afetados pela existência de irregularidades na superfície de medição, e.g. a topografia. Neste sentido, para obter uma imagem sísmica de alta resolução, faz-se necessário corrigir estas irregularidades usando técnicas de processamento sísmico, e.g. correições estáticas residuais e de campo. O método de empilhamento Superfície de Reflexão Comum, CRS ("Common-Reflection-Surface", em inglês) é uma nova técnica de processamento para simular seções sísmicas com afastamento-nulo, ZO ("Zero-Offset", em inglês) a partir de dados sísmicos de cobertura múltipla. Este método baseia-se na aproximação hiperbólica de tempos de trânsito paraxiais de segunda ordem referido ao raio (central) normal. O operador de empilhamento CRS para uma superfície de medição planar depende de três parâmetros, denominados o ângulo de emergência do raio normal, a curvatura da onda Ponto de Incidência Normal, NIP ("Normal Incidence Point", em inglês) e a curvatura da onda Normal, N. Neste artigo o método de empilhamento CRS ZO 2-D é modificado com a finalidade de considerar uma superfície de medição com topografia suave também dependente desses parâmetros. Com este novo formalismo CRS, obtemos uma seção sísmica ZO de alta resolução, sem aplicar as correições estáticas, onde em cada ponto desta seção são estimados os três parâmetros relevantes do processo de empilhamento CRS.
Resumo:
GEOMAR's autonomous underwater vehicle (AUV Abyss REMUS 6000) was deployed within the framework of a multi-platform experiment in June 2012 with R/V Maria S. Merian cruise MSM21/1b at about 180 km downstream of Denmark Strait. The scientific payload included a pumped Seabird 49 FastCAT CTD system, a paroscientific pressure sensor, and shear and temperature microstructure profiler from Rockland Scientific Inc.. In total, six of eight AUV dives were carried out successfully. Aborts on three dives were caused by strong counter currents the AUV experienced in the Denmark Strait Overflow plume, which made the AUV fail to reach its waypoints on schedule. During all missions the AUV was programmed to dive at constant depth levels along? straight legs approximately parallel to chosen isobaths with a constant speed of 1.6 m s-1 through the water.
Resumo:
This thesis reports on the development of quantitative measurement using micromachined scanning thermal microscopy (SThM) probes. These thermal probes employ a resistive element at their end, which can be used in passive or active modes. With the help of a review of SThM, the current issues and potentials associated with this technique are revealed. As a consequence of this understanding, several experimental and theoretical methods are discussed, which expand our understanding of these probes. The whole thesis can be summarized into three parts, one focusing on the thermal probe, one on probe-sample thermal interactions, and the third on heat transfer within the sample. In the first part, a series of experiments are demonstrated, aimed at characterizing the probe in its electrical and thermal properties, benefiting advanced probe design, and laying a fundamental base for quantifying the temperature of the probe. The second part focuses on two artifacts observed during the thermal scans – one induced by topography and the other by air conduction. Correspondingly, two devices, probing these artifacts, are developed. A topography-free sample, utilizing a pattern transfer technique, minimises topography-related artifacts that limited the reliability of SThM data; a controlled temperature ‘Johnson noise device’, with multiple-heater design, offers a uniform, accurate, temperature distribution. Analyzing results of scan from these samples provides data for studying the thermal interactions within the probe and the tip-sample interface. In the final part, the observation is presented that quantification of measurements depends not only on an accurate measurement tool, but also on a deep understanding of the heat transfer within the sample resulting from the nanoscopic contact. It is believed that work in this thesis contributes to SThM gaining wider application in the scientific community.