909 resultados para testicular measurements


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aiming to determine the relationship between the frequency of testicular shape and the andrological aspects in young Nellore bulls, 18,676 animals were assessed. All andrological examinations were performed between the years 2000 and 2008. Animals were classified as able for breeding, able for breeding in natural mating system, unable for breeding and discarded. The testicular shape was classified as long, fairly long, oval-long, spherical-oval, and spherical. The analysis of Pearson correlations was performed for testicular shape with scrotal circumference, testicular volume, progressive motility, sperm vigor, major defects, minor defects and total defects. Testicles with oval shape prevailed (99.61%). It was obseved that 76.34; 66.34; 64.34; 58.33 and 50.00% of the animals were classified as sound for breeding for shapes long, fairly long, oval-long, spherical-oval, and spherical, respectively. Correlations between testicular shape with scrotal circumference, testicular volume, progressive motility, sperm vigor, major, minor and total defects were 0.26; 0.08; 0.00; 0.11; -0.02; 0.02 and -0.01, respectively. Testicular shape had no influence upon the andrological examination results. Testicles of long shape were prevalent within the population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aspectos macroscópicos e morfométricos dos testículos em catetos e queixadas. Este trabalho objetiva fornecer dados macroscópicos e morfométricos dos testículos dos catetos e queixadas. O material utilizado consistiu de catetos e queixadas oriundos da Fazenda Devaneio Pró-Fauna, Iguape, SP (Reg.1/3593/08480). em 33 queixadas e 20 catetos, após o abate, os testículos foram colhidos e tomados dados morfométricos como: comprimento, largura e espessura (com o auxílio de um paquímetro). Os testículos são ovalados, localizados na região pélvica, inclinados dorso-caudalmente e possuem posição intermediária. O mediastino testicular esta no centro do testículo, ligeiramente desviado para a margem epididimária deste, e termina na extremidade capitata. Os queixadas adultos possuem em média 30,92 ± 3,82 kg de peso corporal e 78,89 ± 4,77 cm de comprimento corporal, enquanto os jovens apresentam 22,93 ± 2,07 kg e 71,57 ± 3,95 cm de comprimento. Os resultados demonstram que no grupo de queixadas adultos estudado o testículo direito teve comprimento, largura e espessura médios de 5,36 ± 0,64cm; 3,64 ± 0,64cm e 3,30 ± 0,52cm respectivamente, enquanto que o esquerdo teve 5,45 ± 0,77cm; 3,68 ± 0,59cm e 3,32 ± 0,54cm. Nos queixadas jovens os valores encontrados foram de 3,20 ± 0,44cm, 2,12 ± 0,26cm e 2,11 ± 0,40cm, e de 3,23 ± 0,47cm; 2,21 ± 0,39cm e 1,99 ± 0,36cm, para a largura, comprimento e espessura dos testículos direito e esquerdo respectivamente. Já para os catetos o testículo direito teve comprimento, largura e espessura de 4,36 ± 0,38cm; 2,74 ± 0,27cm e 2,33 0,46cm respectivamente, enquanto que o esquerdo teve 4,19 ± 0,36cm; 2,68 ± 0,31cm e 2,34 ± 0,28cm. Os dados analisados não tiveram diferenças significativas (p<0,05) entre os valores encontrados para os testículos direito e esquerdo pelo testes de Qui-dradado.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A biotecnologia aplicada à reprodução é uma ferramenta também importante para conservação de espécies ameaçadas de extinção. Algumas espécies de primatas não-humanos neotropicais têm sido amplamente agredidas por ações antrópicas, ocasionando a inclusão de 26 espécies brasileiras na lista oficial de animais ameaçados de extinção do IBAMA. As espécies de primatas não humanos Ateles belzebuth e Ateles paniscus, participantes do gênero Ateles, popularmente chamados de macaco-aranha, encontram-se particularmente ameaçadas. Poucos estudos são realizados acerca do status populacional destas espécies e menos ainda sobre dados reprodutivos e reprodução assistida. O presente trabalho pretendeu avaliar as características andrológicas de exemplares de primatas não humanos do gênero Ateles em cativeiro e comparar a performance dos diluentes TES e CEBRAN II, este último à base de ringer lactato, como criopreservadores de sêmen destas espécies. O experimento foi realizado utilizando 06 exemplares machos de primatas não humanos do gênero Ateles (02 exemplares de Ateles marginatus e 04 exemplares de Ateles paniscus) mantidos sob as mesmas condições de cativeiro no Centro Nacional de Primatas (CENP-SVS/MS), em Ananindeua, Pará. Os animais utilizados foram submetidos a exame clínico-andrológico e biometria testicular, antes da colheita seminal realizada por eletroejaculação. Foram realizadas avaliações físicoquímicas e de patologias espermáticas, além de avaliação de motilidade e vigor no sêmen a fresco e pós-diluição com os diluentes TES e CEBRAN II. As alíquotas de sêmen diluídas com os dois diluentes, na proporção 2:1, foram envasadas em minitubos com capacidade para 0,25 ml e criopreservados em nitrogênio líquido. Após descongelação, as doses envasadas foram avaliadas em teste de termo-resistência (T.T.R.). As médias de volume e concentração espermáticas obtidas foram, respectivamente, 1,94 ml (± 0,83) e 3.020.000 sptz/ml (±275,97). O pH 8 foi observado em todas as amostras e todos os exemplares apresentaram coagulação seminal. O índice de patologias espermáticas encontrados foi alto (69,8% ± 9,05) indicando que pode haver influência da sazonalidade reprodutiva nas características seminais encontradas nos animais deste experimento. Os resultados de avaliação de motilidade e vigor do sêmen a fresco, diluído e no T.T.R. não puderam ser analisadas estatisticamente, pois somente o sêmen de 03 animais demonstrou espermatozóides viáveis pós-descongelação, com resultados que sugerem que o diluente TES apresenta melhor eficiência na preservação de sêmen de Ateles do que o diluente CEBRAN II.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A cutia (Dasyprocta aguti) é um roedor silvestre encontrado amplamente na região Nordeste do Brasil. É uma espécie muito utilizada pela população humana de baixa renda como fonte alternativa de proteína na alimentação. Foram utilizadas 31 cutias, machos, provenientes da Universidade Federal do Piauí (FUFPI), Estado do Piauí e da Escola Superior de Agricultura de Mossoró Estado do Rio Grande do Norte. Os animais foram divididos em grupos etários desde o nascimento até os 14 meses de idade. O diâmetro nuclear médio foi obtido pela medida de 10 núcleos do tipo celular estudado em cada testículo, no estágio 1 do ciclo do epitélio seminífero. Nos animais que não apresentaram o epitélio organizado em estágios bem definidos em virtude da idade, foram feitas medidas em secções transversais escolhidas somente pelo contorno circular. O início da assincronia do processo espermatogênico foi observado a partir dos seis meses de idade. A puberdade, na cutia Dasyprocta aguti, foi definitivamente estabelecida a partir dos nove meses de idade, pois estavam presentes todos os tipos celulares e espermatozóides liberados no lume tubular em grande parte do parênquima testicular.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo foi verificar pela ultrassonografia associada à biometria testicular como ferramenta na seleção de precocidade sexual em machos bubalinos. Foram usados 19 machos mestiços das raças Murrah e Mediterrâneo, com idades entre 11 a 59 meses, no período de 06 de maio a 18 de novembro de 2010. Os animais foram divididos em 12 faixas etárias: 8 animais de 12 a 19 meses; 3 animais de 20 a 29 meses; e 8 animais de 30 a 59 meses. Os animais foram mantidos em sistema extensivo, em área de várzea com pastagem de canarana (Eriochloa SP) sem mineralização. Os animais foram submetidos a exame clínico andrológico, com colheita de sêmen por massagem transretal das ampolas e análises físicas do ejaculado. Os exames ultrassonograficos foram realizados com o aparelho modelo Mindray DP-2200, com transdutor linear transretal 75L50EAV, multi-frequencial de 5,0/7,5/10,0 MHz. A ecodensidade testicular (ECOt) foi expressa em quantidade de pixels/área, utilizando o Programa Image J. Foram coletadas amostras sanguíneas para aferição dos níveis de testosterona. A análise estatística foi feita utilizando-se o programa estatístico SAS 1999. Os resultados da circunferência escrotal mostram médias e desvios padrão mínimo e máximo de 12.88±0.51cm para animais de 12 e 13 meses e de 28.38±0.38cm nos machos com idade maior ou igual a 60 meses, respectivamente. As medidas de volume testicular apresentaram valores mínimo e máximo de 30.28±17.37cm³ em animais de 12 e 13 meses e de 534.25±25.36 cm³ nos animais maiores ou iguais a 60 meses, respectivamente. As médias e desvio padrão da concentração espermática mínima e máxima encontrada foram de 5.5± 3.5(x 10⁶ /mm³) para os animais de 16 e 17 meses e de 51.41± 26.02 (x 10⁶ /mm³) para os maiores ou iguais a 60 meses, respectivamente. Na motilidade espermática as porcentagens mínima e máxima obtidas foram de 10% para animais com 16 e 17 meses e de 80±5.77% para maiores ou iguais a 60 meses, respectivamente. Os defeitos espermáticos totais mínimos e máximos encontrados foram de 18.5 % nos animais de 16 e 17 meses e 3%. Nos maiores ou iguais a 60 meses, respectivamente. Os níveis de testosterona mínimos e máximos encontrados foram de 0.070±0.026 ng/ml para 12 e 13 meses e de 2.762± 0.457 ng/ml para os animais maiores ou iguais a 60 meses, respectivamente. A ecogenicidade para animais na faixa etária de 12 a 13 meses foi de 78.67±6.36 pixel, na faixa de 14 e 15 meses foi de 94.22±3.40 pixel, para os animais com idades de 16 e 17 meses foi de 88.16±3.95 pixel, nos animais entre 18 a 19 meses foi de 96.09±3.40 pixel, para os animais de 20 e 21 meses foi de 103.12±3.86 pixel, para 22 e 23 meses foi de 98.4±5.87 pixel, para a idade de 24 aos 29 meses foi de 114.05±2.42 pixel, na faixa etária de 30 aos 35 meses foi de 109.24±3.13 pixel, para animais de 36 aos 41meses foi de 98.67±3.05 pixel, entre 42 a 47 meses a média foi 99.33±2.01 pixel, entre 48 a 59 meses foi de 96.17±1.90 pixel e nos animais maiores ou iguais a 60 meses de idade foi de 90.13±1.77 pixel. Concluímos, assim, que a ultrassonografia, pela interpretação da ecogenicidade, associada ao exame clinico andrológico, é uma ferramenta que pode ser usada na seleção de precocidade e avaliação de fertilidade de machos bubalinos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A cutia (Dasyprocta aguti) é um roedor silvestre encontrado amplamente na região Nordeste do Brasil. É uma espécie muito utilizada pela população humana de baixa renda como fonte alternativa de proteína na alimentação. Foram utilizadas 31 cutias, machos, provenientes da Universidade Federal do Piauí (FUFPI), Estado do Piauí e da Escola Superior de Agricultura de Mossoró Estado do Rio Grande do Norte. Os animais foram divididos em grupos etários desde o nascimento até os 14 meses de idade. O diâmetro nuclear médio foi obtido pela medida de 10 núcleos do tipo celular estudado em cada testículo, no estágio 1 do ciclo do epitélio seminífero. Nos animais que não apresentaram o epitélio organizado em estágios bem definidos em virtude da idade, foram feitas medidas em secções transversais escolhidas somente pelo contorno circular. O início da assincronia do processo espermatogênico foi observado a partir dos seis meses de idade. A puberdade, na cutia Dasyprocta aguti, foi definitivamente estabelecida a partir dos nove meses de idade, pois estavam presentes todos os tipos celulares e espermatozóides liberados no lume tubular em grande parte do parênquima testicular.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To investigate misalignments (MAs) on retinal nerve fiber layer thickness (RNFLT) measurements obtained with Cirrus(©) SD-OCT. Methods. This was a retrospective, observational, cross-sectional study. Twenty-seven healthy and 29 glaucomatous eyes of 56 individuals with one normal exam and another showing MA were included. MAs were defined as an improper alignment of vertical vessels in the en face image. MAs were classified in complete MA (CMA) and partial MA (PMA), according to their site: 1 (superior, outside the measurement ring (MR)), 2 (superior, within MR), 3 (inferior, within MR), and 4 (inferior, outside MR). We compared RNFLT measurements of aligned versus misaligned exams in all 4 sectors, in the superior area (sectors 1 + 2), inferior area (sectors 3 + 4), and within the measurement ring (sectors 2 + 3). Results. RNFLT measurements at 12 clock-hour of eyes with MAs in the superior area (sectors 1 + 2) were significantly lower than those obtained in the same eyes without MAs (P = 0.043). No significant difference was found in other areas (sectors 1 + 2 + 3 + 4, sectors 3 + 4, and sectors 2 + 3). Conclusion. SD-OCT scans with superior MAs may present lower superior RNFLT measurements compared to aligned exams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The XX male syndrome - Testicular Disorder of Sexual Differentiation (DSD) is a rare condition characterized by a spectrum of clinical presentations, ranging from ambiguous to normal male genitalia. We report hormonal, molecular and cytogenetic evaluations of a boy presenting with this syndrome. Examination of the genitalia at age of 16 months, showed: penis of 3.5 cm, proximal hypospadia and scrotal testes. Pelvic ultrasound did not demonstrate Mullerian duct structures. Karyotype was 46,XX. Gonadotrophin stimulation test yielded insufficient testosterone production. Gonadal biopsy showed seminiferous tubules without evidence of Leydig cells. Molecular studies revealed that SRY and TSPY genes and also DYZ3 sequences were absent. In addition, the lack of deletions or duplications of SOX9, NR5A1, WNT4 and NROB1 regions was verified. The infant was heterozygous for all microsatellites at the 9p region, including DMRT1 gene, investigated. Only 10% of the patients are SRY-negative and usually they have ambiguous genitalia, as the aforementioned patient. The incomplete masculinization suggests gain of function mutation in one or more genes downstream to SRY gene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effectiveness of low-level laser therapy (LLLT) on the improvement of the mandibular movements and painful symptoms in individuals with temporomandibular disorders (TMD). Forty patients were randomly divided into two groups (n=20): Group 1 received the effective dose (GaAlAs laser ? 830 nm, 40 mW, 5J/cm2) and Group 2 received the placebo application (0 J/cm2), in continuous mode on the affected condyle lateral pole: superior, anterior, posterior, and posterior-inferior, twice a week during 4 weeks. Four evaluations were performed: E1 (before laser application), E2 (right after the last application), E3 (one week after the last application) and E4 (30 days after the last application). The Kruskal-Wallis test showed significant more improvements (p<0.01) in painful symptoms in the treated group than in the placebo group. A significant improvement in the range of mandibular movements was observed when the results were compared between the groups at E4. Laser application can be a supportive therapy in the treatment of TMD, since it resulted in the immediate decrease of painful symptoms and increased range of mandibular movements in the treated group. The same results were not observed in the placebo group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of an adequate method for evaluation of the adhesion of root canal filling materials provides more reliable results to allow comparison of the materials and substantiate their clinical choice. The aims of this study were to compare the shear bond strength (SBS) test and push-out test for evaluation of the adhesion of an epoxy-based endodontic sealer (AH Plus) to dentin and gutta-percha, and to assess the failure modes on the debonded surfaces by means of scanning electron microscopy (SEM). Three groups were established (n=7): in group 1, root cylinders obtained from human canines were embedded in acrylic resin and had their canals prepared and filled with sealer; in group 2, longitudinal sections of dentin cylinders were embedded in resin with the canal surface smoothed and turned upwards; in group 3, gutta-percha cylinders were embedded in resin. Polyethylene tubes filled with sealer were positioned on the polished surface of the specimens (groups 2 and 3). The push-out test (group 1) and the SBS test (groups 2 and 3) were performed in an Instron universal testing machine running at crosshead speed of 1 mm/min. Means (±SD) in MPa were: G1 (8.8±1.13), G2 (5.9±1.05) and G3 (3.8±0.55). Statistical analysis by ANOVA and Student's t-test (a=0.05) revealed statistically significant differences (p<0.01) among the groups. SEM analysis showed a predominance of adhesive and mixed failures of AH Plus sealer. The tested surface affected significantly the results with the sealer reaching higher bond strength to dentin than to gutta-percha with the SBS test. The comparison of the employed methodologies showed that the SBS test produced significantly lower bond strength values than the push-out test, was skilful in determining the adhesion of AH Plus sealer to dentin and gutta-percha, and required specimens that could be easily prepared for SEM, presenting as a viable alternative for further experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of tokamak plasma light emissions in the vacuum ultraviolet (VUV) region is an important subject since many impurity spectral emissions are present in this region. These spectral emissions can be used to determine the plasma ion temperature and density from different species and spatial positions inside plasma according to their temperatures. We have analyzed VUV spectra from 500 Å to 3200 Å wavelength in the TCABR tokamak plasma including higher diffraction order emissions. There have been identified 37 first diffraction order emissions, resulting in 28 second diffraction order, 24 third diffraction order, and 7 fourth diffraction order lines. The emissions are from impurity species such as OII, OIII, OIV, OV, OVI, OVII, CII, CIII, CIV, NIII, NIV, and NV. All the spectra beyond 1900 Å are from higher diffraction order emissions, and possess much better spectral resolution. Each strong and isolated spectral line, as well as its higher diffraction order emissions suitable for plasma diagnostic is identified and discussed. Finally, an example of ion temperature determination using different diffraction order is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In children with Duchenne muscular dystrophy, color vision losses have been related to dystrophin deletions downstream of exon 30, which affect a dystrophin isoform, Dp260, present in the retina. To further evaluate visual function in DMD children, we measured spatial, temporal, and chromatic red-green and blue-yellow contrast sensitivity in two groups of DMD children with gene deletion downstream and upstream of exon 30. Psychophysical spatial contrast sensitivity was measured for low, middle, and high spatial frequencies with achromatic gratings and for low and middle frequencies with red-green and blue-yellow chromatic gratings. Temporal contrast sensitivity was also measured with achromatic stimuli. A reduction in sensitivity at all spatial luminance contrasts was found for the DMD patients with deletion downstream of exon 30. Similar results were found for temporal luminance contrast sensitivity. Red-green chromatic contrast sensitivity was reduced in DMD children with deletion downstream of exon 30, whereas blue-yellow chromatic contrast sensitivity showed no significant differences. We conclude that visual function is impaired in DMD children. Furthermore, we report a genotype-phenotype relationship because the visual impairment occurred in children with deletion downstream but not upstream of exon 30, affecting the retinal isoform of dystrophin Dp260.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the reproducibility, reliability and validity of measurements in digital models compared to plaster models. Fifteen pairs of plaster models were obtained from orthodontic patients with permanent dentition before treatment. These were digitized to be evaluated with the program Cécile3 v2.554.2 beta. Two examiners measured three times the mesiodistal width of all the teeth present, intercanine, interpremolar and intermolar distances, overjet and overbite. The plaster models were measured using a digital vernier. The t-Student test for paired samples and interclass correlation coefficient (ICC) were used for statistical analysis. The ICC of the digital models were 0.84 ± 0.15 (intra-examiner) and 0.80 ± 0.19 (inter-examiner). The average mean difference of the digital models was 0.23 ± 0.14 and 0.24 ± 0.11 for each examiner, respectively. When the two types of measurements were compared, the values obtained from the digital models were lower than those obtained from the plaster models (p < 0.05), although the differences were considered clinically insignificant (differences < 0.1 mm). The Cécile digital models are a clinically acceptable alternative for use in Orthodontics.