869 resultados para system comparison


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using polydispersity index as an additional order parameter we investigate freezing/melting transition of Lennard-Jones polydisperse systems (with Gaussian polydispersity in size), especially to gain insight into the origin of the terminal polydispersity. The average inherent structure (IS) energy and root mean square displacement (RMSD) of the solid before melting both exhibit quite similar polydispersity dependence including a discontinuity at solid-liquid transition point. Lindemann ratio, obtained from RMSD, is found to be dependent on temperature. At a given number density, there exists a value of polydispersity index (delta (P)) above which no crystalline solid is stable. This transition value of polydispersity(termed as transition polydispersity, delta (P) ) is found to depend strongly on temperature, a feature missed in hard sphere model systems. Additionally, for a particular temperature when number density is increased, delta (P) shifts to higher values. This temperature and number density dependent value of delta (P) saturates surprisingly to a value which is found to be nearly the same for all temperatures, known as terminal polydispersity (delta (TP)). This value (delta (TP) similar to 0.11) is in excellent agreement with the experimental value of 0.12, but differs from hard sphere transition where this limiting value is only 0.048. Terminal polydispersity (delta (TP)) thus has a quasiuniversal character. Interestingly, the bifurcation diagram obtained from non-linear integral equation theories of freezing seems to provide an explanation of the existence of unique terminal polydispersity in polydisperse systems. Global bond orientational order parameter is calculated to obtain further insights into mechanism for melting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cogeneration may be defined as the simultaneous production of electric power and useful heat from the burning of a single fuel. This technique of combined heat and power production has been applied in both the industrial and tertiary sectors. It has been mainly used because of its overall efficiency, and the guarantee of electricity with a low level of environmental impact. The compact cogeneration systems using internal combustion engine as prime movers are thoroughly applied because of the good relationship among cost and benefit obtained in such devices. The cogeneration system of this study consists of an internal combustion engine using natural gas or biogas as fuel, combined with two heat exchangers and an absorption chiller utilising water-ammonia as working mixture. This work presents an energetic and economic comparison between natural gas and biogas as fuel used for the system proposed. The results are useful to identify the feasible applications for this system, such as residential sector in isolated areas, hotels, universities etc. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Antifibrinolytic agents are often used in different clinical situations, especially in cardiac surgery. During several years, aprotinin was the drug of choice because more than antifibrinolytic properties, aprotinin offers a direct effect on kallikrein and inflammatory pathways. In 2008, The Blood Conservation Using Antifibrinolytics in a Randomized Trial (BART) initiated a discussion about real risks associated with aprotinin administration. Tranexamic acid and epsilon-aminocaproic acid appear to be interesting alternatives in our daily practice. The exact mechanism of action, the pharmacokinetic parameters, the efficacy, and the safety profile need to be clarified for lysine analogs. In this review, the different antifibrinolytics will be described with a special interest into the route of work, and recent patents. Current studies about the pharmacokinetic and the pharmacodynamic profile will be described, and finally the benefit-to-risk balance in patients undergoing cardiac surgery with cardiopulmonary bypass will be discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To compare two models of pulmonary hypertension (monocrotaline and monocrotaline+pneumonectomy) regarding hemodynamic severity, structure of pulmonary arteries, inflammatory markers (IL-1 and PDGF), and 45-day survival. Methods: We used 80 Sprague-Dawley rats in two study protocols: structural analysis; and survival analysis. The rats were divided into four groups: control; monocrotaline (M), pneumonectomy (P), and monocrotaline+pneumonectomy (M+P). In the structural analysis protocol, 40 rats (10/group) were catheterized for the determination of hemodynamic variables, followed by euthanasia for the removal of heart and lung tissue. The right ventricle (RV) was dissected from the interventricular septum (IS), and the ratio between RV weight and the weight of the left ventricle (LV) plus IS (RV/LV+IS) was taken as the index of RV hypertrophy. In lung tissues, we performed histological analyses, as well as using ELISA to determine IL-1 and PDGF levels. In the survival protocol, 40 animals (10/group) were followed for 45 days. Results: The M and M+P rats developed pulmonary hypertension, whereas the control and P rats did not. The RV/LV+IS ratio was significantly higher in M+P rats than in M rats, as well as being significantly higher in M and M+P rats than in control and P rats. There were no significant differences between the M and M+P rats regarding the area of the medial layer of the pulmonary arteries; IL-1 and PDGF levels; or survival. Conclusions: On the basis of our results, we cannot conclude that the monocrotaline+pneumonectomy model is superior to the monocrotaline model.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Synthesizing data from multiple studies generates hypotheses about factors that affect the distribution and abundance of species among ecosystems. Snails are dominant herbivores in many freshwater ecosystems, but there is no comprehensive review of snail density, standing stock, or body size among freshwater ecosystems. We compile data on snail density and standing stock, estimate body size with their quotient, and discuss the major pattern that emerges. We report data from 215 freshwater ecosystems taken from 88 studies that we placed into nine categories. Sixty-five studies reported density, seven reported standing stock, and 16 reported both. Despite the breadth of studies, spatial and temporal sampling scales were limited. Researchers used 25 different sampling devices ranging in area from 0.0015 to 2.5 m2. Most ecosystem categories had similar snail densities, standing stocks, and body sizes suggesting snails shared a similar function among ecosystems. Caribbean karst wetlands were a striking exception with much lower density and standing stock, but large body size. Disparity in body size results from the presence of ampullariids in Caribbean karst wetlands suggesting that biogeography affects the distribution of taxa, and in this case size, among aquatic ecosystems. We propose that resource quality explains the disparity in density and standing stock between Caribbean karst wetlands and other categories. Periphyton in Caribbean karst wetlands has high carbon-to-phosphorous ratios and defensive characteristics that inhibit grazers. Unlike many freshwater ecosystems where snails are key grazers, we hypothesize that a microbial loop captures much of the primary production in Caribbean karst wetlands.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Within the aging building stock of Europe, there is great potential of saving energy through renovation and upgrading to modern standards, and to thereby approach the internationally set goals of lower energy use. This paper concerns the planned renovation of the building envelope and HVAC systems in a multi-family house in Ludwigsburg, Germany. Five systemic HVAC solutions were compared, with special focus on two systems: A) Balanced ventilation with HRC + Micro heat pump, and B) Forced exhaust ventilation + Heat pump with exhaust air HRC + Ventilation radiators. Given the predicted heating demand and ventilation rate of the house after renovation, the performance of the two systems was compared, alongside three common systems for reference. Calculations were made using TMF Energi, a tool developed by SP Technical Research Institute of Sweden.    Both systems A and B were found to have the lowest electrical energy use together with the ground source heat pump system for the assumed conditions. For other assumptions, including different climate and degree of insulation, some differences between these three systems were noted. Most significant is the increased electrical use of system B for higher heating loads due to limitations in the power available from the heat source, exhaust air, which is dependent on the ventilation rate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The English examination system provides a market in which a limited number of providers are accredited to offer curriculum-based examinations in many subject areas and at several levels. The most significant are the General Certificate of Secondary Education (GCSE) and the General Certificate of Education, Advanced (A level). Because these examinations are used for high-stakes purposes, including higher education and employment selection for individuals and programme evaluation for institutions, it is desired that scores from various exams be ‘comparable’ in several respects: across syllabuses and examination boards within a subject area, across years, and even across subject areas. Just how to accomplish this goal has been a topic of continual research and debate for over 50 years, through many changes of examination and institutional structures. But ever year, tens of thousands of scores must be reported, and every year, users expect them to ‘be comparable’ and use them as if they are.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Two electrical techniques that are frequently used to characterize radio frequency plasmas are described: current-voltage probes for plasma power input and compensated Langmuir probes for electron energy probability functions and other parameters. The following examples of the use of these techniques, sometimes in conjunction with other diagnostic methods, are presented: plasma source standardization, plasma system comparison, power efficiency, plasma modelling and complex processing plasma mechanisms.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this work was the study of numerical methods for differential equations of fractional order and ordinary. These methods were applied to the problem of calculating the distribution of the concentration of a given substance over time in a given physical system. The two compartment model was used for representation of this system. Comparison between numerical solutions obtained were performed and, in particular, also compared with the analytical solution of this problem. Finally, estimates for the error between the solutions were calculated

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Energieeffizienz und Leistungsfähigkeit von fördertechnischen Anlagen sind in den vergangenen Jahren immer mehr in den Fokus der Betreiber und Hersteller gerückt. Im Rahmen einer Untersuchung am Fraunhofer-Institut für Materialfluss und Logistik IML wurden diese beiden Aspekte an magnetisch erregten und piezoerregten Schwingförderern untersucht. Ein Systemvergleich stellt dabei die wesentlichen Vor- und Nachteile der jeweiligen Antriebsart dar und unterstützt sowohl bei der Auswahl als auch bei der Optimierung von Transportsystemen im logistischen Umfeld.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With the extensive use of pulse modulation methods in telecommunications, much work has been done in the search for a better utilisation of the transmission channel.The present research is an extension of these investigations. A new modulation method, 'Variable Time-Scale Information Processing', (VTSIP), is proposed.The basic principles of this system have been established, and the main advantages and disadvantages investigated. With the proposed system, comparison circuits detect the instants at which the input signal voltage crosses predetermined amplitude levels.The time intervals between these occurrences are measured digitally and the results are temporarily stored, before being transmitted.After reception, an inverse process enables the original signal to be reconstituted.The advantage of this system is that the irregularities in the rate of information contained in the input signal are smoothed out before transmission, allowing the use of a smaller transmission bandwidth. A disadvantage of the system is the time delay necessarily introduced by the storage process.Another disadvantage is a type of distortion caused by the finite store capacity.A simulation of the system has been made using a standard speech signal, to make some assessment of this distortion. It is concluded that the new system should be an improvement on existing pulse transmission systems, allowing the use of a smaller transmission bandwidth, but introducing a time delay.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: To compare three different methods of falls reporting and examine the characteristics of the data missing from the hospital incident reporting system. DESIGN: Fourteen-month prospective observational study nested within a randomized controlled trial. SETTING: Rehabilitation, stroke, medical, surgical, and orthopedic wards in Perth and Brisbane, Australia. PARTICIPANTS: Fallers (n5153) who were part of a larger trial (1,206 participants, mean age 75.1 � 11.0). MEASUREMENTS: Three falls events reporting measures: participants’ self-report of fall events, fall events reported in participants’ case notes, and falls events reported through the hospital reporting systems. RESULTS: The three reporting systems identified 245 falls events in total. Participants’ case notes captured 226 (92.2%) falls events, hospital incident reporting systems captured 185 (75.5%) falls events, and participant selfreport captured 147 (60.2%) falls events. Falls events were significantly less likely to be recorded in hospital reporting systems when a participant sustained a subsequent fall, (P5.01) or when the fall occurred in the morning shift (P5.01) or afternoon shift (P5.01). CONCLUSION: Falls data missing from hospital incident report systems are not missing completely at random and therefore will introduce bias in some analyses if the factor investigated is related to whether the data ismissing.Multimodal approaches to collecting falls data are preferable to relying on a single source alone.