896 resultados para surface treatment
Resumo:
OBJECTIVE: To assess microleakage in conservative class V cavities prepared with aluminum-oxide air abrasion or turbine and restored with self-etching or etch-and-rinse adhesive systems. Materials and Methods: Forty premolars were randomly assigned to 4 groups (I and II: air abrasion; III and IV: turbine) and class V cavities were prepared on the buccal surfaces. Conditioning approaches were: groups I/III - 37% phosphoric acid; groups II/IV - self-priming etchant (Tyrian-SPE). Cavities were restored with One Step Plus/Filtek Z250. After finishing, specimens were thermocycled, immersed in 50% silver nitrate, and serially sectioned. Microleakage at the occlusal and cervical interfaces was measured in mm and calculated by a software. Data were subjected to ANOVA and Tukey's test (α=0.05). RESULTS: Marginal seal provided by air abrasion was similar to high-speed handpiece, except for group I. There was SIGNIFICANT difference between enamel and dentin/cementum margins for to group I and II: air abrasion. The etch-and-rinse adhesive system promoted a better marginal seal. At enamel and dentin/cementum margins, the highest microleakage values were found in cavities treated with the self-etching adhesive system. At dentin/cementum margins, high-speed handpiece preparations associated with etch-and-rinse system provided the least dye penetration. CONCLUSION: Marginal seal of cavities prepared with aluminum-oxide air abrasion was different from that of conventionally prepared cavities, and the etch-and-rinse system promoted higher marginal seal at both enamel and dentin margins.
Resumo:
There are currently many types of protective materials for reinforced concrete structures and the influence of these materials in the chloride diffusion coefficient still needs more research. The aim of this paper is to study the efficacy of certain surface treatments (such as hydrophobic agents, acrylic coating, polyurethane coating and double systems) in inhibiting chloride penetration in concrete. The results indicated that all tested surface protection significantly reduced the sorptivity of concrete (reduction rate > 70%). However, only the polyurethane coating was highly effective in reducing the chloride diffusion coefficient (reduction rate of 86%). (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Objective: The objective of this study was to evaluate the influence of the surface treatment and acid conditioning (AC) time of bovine sclerotic dentine on the micro-tensile bond strength (mu-TBS) to an etch and rinse adhesive system. Materials and method: Thirty-six bovine incisors were divided into six groups (n = 6): G1 sound dentine submitted to AC for 15 s; G2-G6 sclerotic dentine: G2-AC for 15 s; G3-AC for 30 s; G4-EDTA and AC for 15 s; G5-diamond bur and AC for 15 s; G6-diamond paste and AC for 15 s. An adhesive system was applied to the treated dentine surfaces followed by a hybrid composite inserted in increments and light cured. After 24 h storage in water at 37 degrees C, the specimens were perpendicularly cut with a low-speed diamond saw to obtain beams (0.8 mm x 0.8 mm cross-sectional dimensions) for mu-TBS testing. Data was compared by ANOVA followed by Tukey`s test (P <= 0.05). Results: The mean L-TBS was G1: 18.87 +/- 5.36 MPa; G2: 12.94 +/- 2.09 MPa; G3: 11.73 +/- 0.64 MPa; G4: 11.14 +/- 1.50 MPa; G5: 22.75 +/- 4.10 MPa; G6: 22.48 +/- 2.71 MPa. G1, G5 and G6 presented similar bond strengths significantly higher than those of all other groups. Conclusion: The surface treatment of sclerotic dentine significantly influenced the bond strength to an adhesive system. Mechanical treatment, either using a diamond bur or a diamond paste was able to improve bonding to bovine sclerotic dentine, reaching values similar to bonding to sound dentine. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
The influence of premetallization surface preparation on the structural, chemical, and electrical properties of Au-nGaN interfaces has been investigated by x-ray photoemission spectroscopy (XPS), current-voltage measurement (I-V) and cross-section transmission electron microscopy (TEM). XPS analysis showed that the three GaN substrate treatments investigated i.e., ex situ hydrofluoric acid etch, in situ anneal in ultrahigh-vacuum (UHV), and in situ Ga reflux cleaning in UHV result in surfaces increasingly free of oxygen contamination. XPS and TEM characterization of Au-nGaN formed after the three premetallization surface treatments show that HF etching and UHV annealing produce abrupt, well-defined interfaces. Conversely, GaN substrate cleaning in a Ga flux results in Au/GaN intermixing. I-V characterization of Au¿nGaN contacts yields a Schottky barrier height of 1.25 eV with a very low-ideality factor and very good contact uniformity for the premetallization UHV anneal, while the Ga reflux cleaning results in a much lower barrier (0.85 eV), with poor ideality and uniformity. I-V and XPS results suggest a high density of acceptor states at the surface, which is further enhanced by UHV annealing. These results are discussed in the context of current models of Schottky barrier formation.
Resumo:
The objective of this work was to introduce the emerging non-contacting spray coating process and compare it to the existing coating techniques. Particular emphasis was given to the details of the spraying process of paper coating colour and the base paper requirements set by the new coating method. Spraying technology itself is nothing new, but the atomisation process of paper coating colour is quite unknown to the paper industry. The differences between the rheology of painting and coating colours make it very difficult to utilise the existing information from spray painting research. Based on the trials, some basic conclusion can be made:The results of this study suggest that the Brookfield viscosity of spray coating colour should be as low as possible, presently a 50 mPas level is regarded as an optimum. For the paper quality and coater runnability, the solids level should be as high as possible. However, the graininess of coated paper surface and the nozzle wear limits the maximum solids level to 60 % at the moment. Most likelydue to the low solids and low viscosity of the coating colour the low shear Brookfield viscosity correlates very well with the paper and spray fan qualities. High shear viscosity is also important, but yet less significant than the low shear viscosity. Droplet size should be minimized and besides keeping the brrokfield viscosity low that can be helped by using a surfactant or dispersing agent in the coating colour formula. Increasing the spraying pressure in the nozzle can also reduce the droplet size. The small droplet size also improves the coating coverage, since there is hardly any levelling taking place after the impact with the base paper. Because of the lack of shear forces after the application, the pigment particles do not orientate along the paper surface. Therefore the study indicates that based on the present know-how, no quality improvements can be obtained by the use of platy type of pigments. The other disadvantage of them is the rapid deterioration of the nozzle lifetime. Further research in both coating colour rheology and nozzle design may change this in the future, but so far only round shape pigments, like typically calcium carbonate is, can be used with spray coating. The low water retention characteristics of spray coating, enhanced by the low solids and low viscosity, challenge the base paper absorption properties.Filler level has to be low not to increase the number of small pores, which have a great influence on the absorption properties of the base paper. Hydrophobic sizing reduces this absorption and prevents binder migration efficiently. High surface roughness and especially poor formation of the base paper deteriorate thespray coated paper properties. However, pre-calendering of the base paper does not contribute anything to the finished paper quality, at least at the coating colour solids level below 60 %. When targeting a standard offset LWC grade, spraycoating produces similar quality to film coating, but yet blade coating being on a slightly better level. However, because of the savings in both investment and production costs, spray coating may have an excellent future ahead. The porousnature of the spray coated surface offers an optimum substrate for the coldset printing industry to utilise the potential of high quality papers in their business.
Resumo:
The focus of the work reported in this thesis was to study and to clarify the effect of polyelectrolyte multilayer surface treatment on inkjet ink spreading, absorption and print quality. Surface sizing with a size press, film press with a pilot scale coater, and spray coating, have been used to surface treat uncoated wood-free, experimental wood-free and pigmentcoated substrates. The role of the deposited cationic (polydiallydimethylammonium chloride, PDADMAC) and anionic (sodium carboxymethyl cellulose, NaCMC) polyelectrolyte layers with and without nanosilica, on liquid absorption and spreading was studied in terms of their interaction with water-based pigmented and dye-based inkjet inks. Contact angle measurements were made in attempt to explain the ink spreading and wetting behavior on the substrate. First, it was noticed that multilayer surface treatment decreased the contact angle of water, giving a hydrophilic character to the surface. The results showed that the number of cationic-anionic polyelectrolyte layers or the order of deposition of the polyelectrolytes had a significant effect on the print quality. This was seen for example as a higher print density on layers with a cationic polyelectrolyte in the outermost layer. The number of layers had an influence on the print quality; the print density increased with increasing number of layers, although the increase was strongly dependent on ink formulation and chemistry. The use of nanosilica clearly affected the rate of absorption of polar liquids, which also was seen as a higher density of the black dye-based print. Slightly unexpected, the use of nanosilica increased the tendency for lateral spreading of both the pigmented and dye-based inks. It was shown that the wetting behavior and wicking of the inks on the polyelectrolyte coatings was strongly affected by the hydrophobicity of the substrate, as well as by the composition or structure of the polyelectrolyte layers. Coating only with a cationic polyelectrolyte was not sufficient to improve dye fixation, but it was demonstrated that a cationic-anionic-complex structure led to good water fastness. A threelayered structure gave the same water fastness values as a five-layered structure. Interestingly, the water fastness values were strongly dependent not only on the formed cation-anion polyelectrolyte complexes but also on the tendency of the coating to dissolve during immersion in water. Results showed that by optimizing the chemistry of the layers, the ink-substrate interaction can be optimized.
Resumo:
The purpose of this study was to investigate the effect of Er:YAG laser on surface treatment to the bond strength of repaired composite resin after aged. Sixty specimens (n = 10) were made with composite resin (Z250, 3M) and thermocycled with 500 cycles, oscillating between 5 to 55A degrees C. The specimens were randomly separated in six groups which suffered the following superficial treatments: no treatment (GI, control), wearing with diamond bur (GII), sandblasted with aluminum oxide with 27.5 A mu m particles (GIII) for 10 s, 200 mJ Er:YAG laser (GIV), 300 mJ Er:YAG laser (GV), and 400 mJ Er:YAG laser (GVI), with the last 3 groups under a 10 Hz frequency for 10 s. Restoration repair was done using the same composite. The shear test was done into the Universal testing machine MTS-810. Analyzing the results through ANOVA and Tukey test, no significant differences were found (p-value is 0.5120). Average values analysis showed that superficial treatment with aluminum oxide presented the highest resistance to shear repair interface (8.91MPa) while 400 mJ Er:YAG laser presented the lowest (6.76 MPa). Fracture types analysis revealed that 90% suffered cohesive fractures to GIII. The Er:YAG laser used as superficial treatment of the aged composite resin before the repair showed similar results when used diamond bur and sandblasting with aluminum oxide particles.
Resumo:
If a plastic material is used as a print bearer there are a need of a special surface treatment to get agod and durable printing. The most used surface treatment technique for the moment is coronatreatment. This kind of treatment has unfortunately showed not to be so durable in the long term.Plasma treatment which in this case uses different kind of gases in the treatment of polypropyleneis shown as a more effective treatment in this project. When the plasma treated surface has beenprinted is the good quality last much longer and the adhesion between the ink and the surface isremained. To test this adhesion is for the moment a standard used (ASTM D3359). This standardhas appeared unstable and dependent at many different factors, which gives a big variation in thetest results. Because of this has new test methods been carried out to give a more even and morereliable result in the test of the adhesion.
Resumo:
Objectives The purpose of this work was to submit the Nitinol files to plasma immersion ion implantation (PIII) and evaluate the effects of the surface treatment. Materials and Methods Wear resistance was determined in vitro by using an equipment for the application of horizontal movements on previously prepared notched plates made of resin. Vickers microhardness was measured in plates and files, before and after surface treatment and the surface chemical composition of the instruments was determined by X-rays photoelectron spectroscopy. Results The hardness values found for the treated Nitinol files were significantly lower than the hardness values measured before the implantation process. The comparison of commercially available instruments shows that the wear resistance of the stainless steel file is higher than the resistance of the Nitinol. Conclusions The results found led to the conclusion that the surface treatment significantly increased the Nitinol files wear resistance.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Replantation is an acceptable option for treatment of an avulsed permanent tooth. Nevertheless, an extended extraoral period damages the periodontal ligament and results in external root resorption. The purpose of this study was to assess by histologic and histometric analysis, the influence of propolis 15% (natural resinous substance collected by Apis mellifera bees from various plants) and the fluoride solution used as root surface treatment on the healing process after delayed tooth replantation. Thirty Wistar (Rattus norvegicus albinus) rats were submitted to extraction of their upper right incisor. The teeth were maintained in a dry environment for 60 min. After this, the pulp was extirpated and the papilla, enamel organ and periodontal ligament were removed with scalpel. The teeth were divided into three experimental groups: Group I - teeth immersed in 20 ml of physiologic saline; Group II - teeth immersed in 20 ml of 2% acidulated phosphate sodium fluoride; Group III - teeth immersed in 20 ml of 15% propolis. After 10 min of immersion in the solutions, the root canals were dried and filled with calcium hydroxide paste and the teeth were replanted. The animals were euthanized 60 days after replantation. The results showed that similar external root resorption was seen in the propolis and fluoride groups. Teeth treated with physiologic saline tended to have more inflammatory root resorption compared with those treated with fluoride or propolis. However, the comparative analysis did not reveal statistically significant differences (P > 0.05) between the treatment modalities when used for delayed tooth replantation.
Resumo:
Direct relining of dentures made with hard chairside reline resins is faster than laboratory-processed reline systems and the patient is not without the prosthesis for the time necessary to perform the laboratory procedures. However, a weak bond between the autopolymerizing acrylic reline resins and the denture base material has been observed. This study evaluated the effect of six different surface treatments on the bond strength between a hard chairside reline acrylic resin and ia heat-cured acrylic resin. Specimens of the heat-cured acrylic resin were divided into seven groups. one of these groups remained intact. In the other groups, a 10-mm square section was removed from the centre of each specimen. The bonding surfaces were then treated with (i) methyl methacrylate monomer, (ii) isobutyl methacrylate monomer, (iii) chloroform, (iv) acetone, (v) experimental adhesive and (vi) no surface treatment-control group. Kooliner acrylic resin was packed,into the square sections and polymerized. The bonding strength was evaluated by a three-point loading test. The results were submitted to one-way analysis of variance (ANOVA) followed by a Tukey multiple range test at a 5% level of significance. No significant difference was found between the surface treatment with Lucitone 550 monomer or chloroform, but both were stronger than the majority of the other groups. The bond strength provided by all the surface treatments was lower than that of the intact heat-cured resin.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)