998 resultados para spontaneous combustion


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Disbound Original Held in Oak Street Library Facility.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The structure of a comprehensive research project into mine fires study applying the Ventgraph mine fire simulation software, preplanning of escape scenarios and general interaction with rescue responses is outlined. The project has Australian Coal Association Research Program (ACARP) funding and also relies on substantial mining company site support. This practical input from mine operators is essential and allows the approach to be introduced in the most creditable way. The effort is built around the introduction of fire simulation computer software to the Australian mining industry and the consequent modelling of fire scenarios in selected different mine layouts. Application of the simulation software package to the changing mine layouts requires experience to achieve realistic outcomes. Most Australian mines of size currently use a ventilation network simulation program. Under the project a small subroutine has been written to transfer the input data from the existing mine ventilation network simulation program to ‘Ventgraph’. This has been tested successfully. To understand fire simulation behaviour on the mine ventilation system, it is necessary to understood the possible effects of mine fires on various mine ventilation systems correctly first. Case studies demonstrating the possible effects of fires on some typical Australian coal mine ventilation circuits have been examined. The situation in which there is some gas make at the face and effects with fire have also been developed to emphasise how unstable and dangerous situations may arise. The primary objective of the part of the study described in this paper is to use mine fire simulation software to gain better understanding of how spontaneous combustion initiated fires can interact with the complex ventilation behaviour underground during a substantial fire. It focuses on the simulation of spontaneous combustion sourced heatings that develop into open fires. Further, it examines ventilation behaviour effects of spontaneous combustion initiated pillar fires and examines the difficulties these can be present if a ventilation reversal occurs. It also briefly examines simulation of use of the inertisation to assist in mine recovery. Mine fires are recognised across the world as a major hazard issue. New approaches allowing improvement in understanding their consequences have been developed as an aid in handling this complex area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the adequacy of current gas monitoring techniques to adequately detect spontaneous combustion in underground coalmines. Despite being in the 21st century spontaneous combustion continues to occur in underground coalmines sometimes being detected only at a very advanced stage. Control of the incident is often then very expensive and time consuming. The adequacy needs to be assessed not only from the point of view of the analysis technique be it tube bundle, gas chromatograph or real time sensor but also the number, location and sampling frequency of the monitoring locations. Recommendations are made to optimise monitoring processes and recognise limitations of current techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Numerical modelling has been used to examine the relationship between the results of two commonly used methods of assessing the propensity of coal to spontaneous combustion, the R70 and Relative Ignition Temperature tests, and the likely behaviour in situ. The criticality of various parameters has been examined and a method of utilising critical self-heating parameters has been developed. This study shows that on their own, the laboratory test results do not provide a reliable guide to in situ behaviour but can be used in combination to considerably increase the ability to predict spontaneous combustion behaviour.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The general purpose of this study was the determination of the safety conditions to avoid the presence of explosive atmospheres in the wastewater industry. Eight Spanish plants located in Madrid, Barcelona and Málaga were considered and several sludge samples were taken in different seasons. The base for the assessment of the spontaneous ignition behaviour of dust accumulations is the experimental determination of the self-ignition temperature under isothermal conditions. Self-ignition temperatures at four volumes were obtained for one sample of sewage sludge, allowing their extrapolation to large storage facilities. A simple test method, based also on an isothermal study of samples, is the UN classification of substances liable to spontaneous combustion. Two different samples were so tested, obtaining unlike results if transported in packages of different volumes. By means of thermogravimetric techniques it is possible to analyse the thermal susceptibility of dried sewage sludge. Apparent activation energy can be obtained from the rate of weight loss. It is also applied to the study of self-ignition susceptibility by modifying test conditions when oxygen stream is introduced. As a consequence of this oxidant contribution, sample behaviour can be very different during testing and a step drop or sudden loss of weight is observed at a characteristic temperature for every substance, associated to a rapid combustion. Plotting both the activation energy and the characteristic temperature, a map of self-ignition risk was obtained for 10 samples, showing different risk levels for samples taken in different locations and at different seasons. A prediction of the self-ignition risk level can be also determined.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Large scale sugarcane bagasse storage in uncovered stockpiles has the potential to result in adverse impacts on the environment and surrounding communities through hazards associated with nuisance dust, groundwater seepage, spontaneous combustion and generation of contaminated leachates. Managing these hazards will assist in improved health and safety outcomes for factory staff and reduced potential environmental impacts on surrounding communities. Removal of the smaller fibres (pith) from bagasse prior to stockpiling reduced the dust number of bagasse by 50% and modelling suggests peak ground level PM10 dust emissions would reduce by 70%. Depithed bagasse has much lower water holding capacity (~43%) than whole bagasse. This experimental and modelling study investigated the physical properties of depithed and whole bagasse. Dust dispersion modelling was undertaken to determine the likely effects associated with storage of whole and depithed sugarcane bagasse.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To develop a chemical inhibitor that can efficiently suppress coal oxidation, nine tetraalkylphosphonium-based ionic liquids (ILs) and one imidazolium-based IL [1-allyl-3-methylimidazolium chloride ([AMIm]Cl)] were examined as additives. These ILs were used to treat and investigate the inhibitory effect on the oxidation activity and the structure of lignite coal. Characterization using thermogravimetric analysis showed that phosphonium-based ILs are able to inhibit coal oxidation up to 400 degrees C with the tributylethylphosphonium diethylphosphate ([P-4,P-4,P-4,P-2][DEP]) found to be the most effective. In contrast to the tetraalkylphosphonium-based ILs, inhibition using [AMIm]Cl was only found to be effective at temperatures below 250 degrees C, indicating that the tetraallcylphosphonium-based ILs may be more suitable for the future application of suppressing coal spontaneous combustion over a wide range of temperatures. Fourier transform infrared spectroscopic data showed that the various functional groups change in the coal following IL treatment, which are a decrease in the minerals and hydrogen bonds in all treated coals, while decreased aliphatic hydrocarbon and increased carbonyl bonds only appeared in some samples. During the oxidation of coal, the decomposition of aliphatic hydrocarbon groups is inhibited and the formation of carbonyl groups is delayed, so that the evolved gas concentration decreased, as shown by the temperature-programmed oxidation-mass spectrometry results. The deployment of the [P-4,P-4,P-4,P-2][ DEP] and tributylmethylphosphonium methylsulfate Its as additives also show good inhibitory effect on coal oxidation over the temperature range studied, and a relatively stronger interaction between [P-4,P-4,P-4,P-2] [DEP] and coal is demonstrated by the additive model.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dry sewage sludge are being considered as a possible energy source for direct firing. They have interesting properties to be used as an alternative fuel, but also other characteristics must be considered from the point of view of its safe operation: the most important are ignition sensitivity, explosion severity, thermal sensitivity and thermal stability. The aim of this study was to determine if sewage sludge have different characteristics due to different locations or seasons and how this influences their flammability properties. To study these characteristics sludge samples were selected from different locations in Spain, taken during different seasons. In addition, relationships between flammability parameters and chemical analysis were observed. Some parameters can be controlled during normal operation, such as granulometry or humidity, and may mean a decrease in the risk of explosion. Those relationships are well known for other dusts materials, like coal, but not yet for sewage sludge dusts. Finally, properties related to spontaneous combustion were determined (thermal susceptibility and stability). The addition of those properties to the study provides an overview of the thermal behavior of sewage sludge during their utilization, including transport and storage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The treatment and disposal of sewage sludge is becoming an urgent need whereby different technologies were developed and integrated into the waste cycle all over the world. One of the most used technologies is the thermal drying of the sludge. Thermally dried sewage sludge has interesting properties that allow its use as an alternative fuel, but also needs some consideration from the point of view of its safe operation. The aim of this study was the research on the flammability properties of sewage sludge, including ignition sensitivity, explosion severity, thermal sensitivity and thermal stability. Furthermore relationships among those properties and composition parameters have been determined, added to the study of their variation depending on their origin or season. Finally, properties related to spontaneous combustion were determined. To study these relationships and characteristics sludge samples were selected from different locations in Spain and taken during different seasons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Borecore samples from the Trap Gully pit at Callide have been assessed using the R-70 self-heating test. The highest R-70 self-heating rate value was 16.22 degrees C/h, which is consistent with the subbituminous rank of the coal. R-70 decreases significantly with increasing mineral matter content, as defined by the ash content of the coal. This effect is due to the mineral matter in the coal acting as a heat sink. A trendline equation has been fitted to the borecore data from the Trap Gully pit: R-70 = 0.0029 x ash(2) - 0.4889 x ash + 20.644, where all parameters are on a dry-basis. This relationship can be used to model the self-heating hazard of the pit, both vertically and laterally. (c) 2005 Elsevier B.V All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Strip samples from the Boundary Hill pit at Callide have been tested in an adiabatic oven to assess the effect of moisture on the R-70 self-heating rate of coal. The two strip samples tested had R-70 self-heating rate values of 10.23 and 8.61 degrees C/h. As the moisture content of the coal was progressively increased, from the dry state of the test, the R-70 value decreased dramatically. At approximately 40-50% of the moisture holding capacity of the coal, the self-heating rate becomes measurable. Above this critical level of moisture content, the heat produced by oxidation is dissipated by moisture evaporation and coal self-heating is significantly delayed. (c) 2005 Elsevier B.V All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Samples from New Zealand and Australia have been tested in an adiabatic oven to assess the effect of rank on the R-70 selfheating rate of coal. A non-linear relationship can be defined for coals from both countries using the revised Suggate rank (S-r) parameter. Subbituminous coals have the highest R-70 self-heating rate values, which are 20 times that of high volatile A bituminous coals on a dry mineral matter free basis (similar to 1 cf. 20 degrees C h(-1)). However, the moderating effects of moisture and mineral matter can reduce this difference to only 2-3 times for coal in-situ. (c) 2005 Elsevier B.V All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There are many physical factors that can affect the self-heating rate of coal. The presence of seam gas has often been referred to as inhibiting coal self-heating due to the limited access of oxidation sites created by the presence of the gas adsorbed on the coal pores. Similarly, the presence of bed moisture in the coal also acts as an inhibitor of oxidation by blocking access of air into the pores. Gas drainage of a coal seam prior to mining removes both gas and moisture from the seam. Bulk coal self-heating tests in a two-metre column on both gassy, as-mined and gas-drained, dried high volatile bituminous coal show that removal of gas and moisture from the coal accelerates the rate of self-heating to thermal runaway from 8.5 days to 4.25 days, from a start temperature of 30°C, with an airflow of 0.25 L/min. The corresponding gas evolution pattern for each of these situations is different. Therefore, it is necessary to take this change in coal condition into consideration when developing a spontaneous combustion management plan.