908 resultados para single-side large optical cavity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electroabsorption modulator with large optical cavity was designed and fabricated successfully. Both the simulated and experimental results show that, the larger optical cavity structure introduced could obviously improve the optical profile of EA modulator, the traditional elliptical near-field spot becomes more rounded, so it will match better with the optical fiber and is beneficial for raising the coupling efficiency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To achieve high optical power as well as low vertical divergence angle, a new kind of optimized large optical cavity (LOC) structure is applied to a ridge waveguide 980nm InGaAs/GaAs/AlGaAs multi-quantum well laser. The optical power density in the waveguide is successfully reduced. The maximum output power is more than 400mW with a slope efficiency of 0.89W/A and the far-field vertical divergence angle is lowered to 23°.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports a novel traveling-wave electroabsorption modulator (TWEAM) with a large optical cavity waveguide and an intrastep quantum well structure designed to achieve a high bandwidth, high saturation power and better fiber-matched optical profile, which is good for high coupling efficiency. The optical mode characteristic shows a great improvement in matching the circular mode of the fiber and the saturation power of 21 dBm, and a 3 dB bandwidth of 23 GHz was achieved for the fabricated TWEAM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a novel scheme to monolithically integrate an evanescently-coupled uni-travelling carrier photodiode with a planar short multimode waveguide structure and a large optical cavity electroabsorption modulator based on a multimode waveguide structure. By simulation, both electroabsorption modulator and photodiode show excellent optical performances. The device can be fabricated with conventional photolithography, reactive ion etching, and chemical wet etching.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

980nm InGaAs/InGaAsP/AlGaAs strained quantum well lasers,vitta novel large optical cavity and asymmetrical claddings was fabricated bg MOCVD. Very high differential quantum efficiency elf 90% (1.15W/A) and low vertical divergence angle of 24 degrees at long cavity length were obtained for 100 mu m stripe lasers. The differential quantum efficiency is up to 94% (1.20) at cavity length of 500 mu m.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrate a simple lossless method for the implementation of repetition-rate multiplication of a periodic pulse train. As it is showed, a single all-pass optical cavity (APOC) can increase the repetition rate of the output pulse train by factors of 2, 3, and 4. Two different APOC implementations, based on a Gires-Tournois interferometer and an all-pass ring resonator, are proposed and numerically demonstrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrated oxide-confined 850-nm vertical-cavity surface-emitting lasers (VCSELs) with a two-dimensional petal-shaped holey structure composed of several annular-sector-shaped holes. Four types of devices with different hole numbers were designed and fabricated. The measured results showed that the larger hole number was beneficial to purifying the lasing mode, and realizing the single-mode operation. The side mode suppression ratio (SMSR) exceeded 30 dB throughout the entire drive current. Mode selective loss mechanism was used to explain the single-mode characteristic. The single-mode devices possessed good beam profiles, and the lowest divergence angle was as narrow as 3.2 degrees (full width at half maximum), attributed to the graded index profile and the shallow etching in the top distributed Bragg reflector (DBR).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A single habit parameterization for the shortwave optical properties of cirrus is presented. The parameterization utilizes a hollow particle geometry, with stepped internal cavities as identified in laboratory and field studies. This particular habit was chosen as both experimental and theoretical results show that the particle exhibits lower asymmetry parameters when compared to solid crystals of the same aspect ratio. The aspect ratio of the particle was varied as a function of maximum dimension, D, in order to adhere to the same physical relationships assumed in the microphysical scheme in a configuration of the Met Office atmosphere-only global model, concerning particle mass, size and effective density. Single scattering properties were then computed using T-Matrix, Ray Tracing with Diffraction on Facets (RTDF) and Ray Tracing (RT) for small, medium, and large size parameters respectively. The scattering properties were integrated over 28 particle size distributions as used in the microphysical scheme. The fits were then parameterized as simple functions of Ice Water Content (IWC) for 6 shortwave bands. The parameterization was implemented into the GA6 configuration of the Met Office Unified Model along with the current operational long-wave parameterization. The GA6 configuration is used to simulate the annual twenty-year short-wave (SW) fluxes at top-of-atmosphere (TOA) and also the temperature and humidity structure of the atmosphere. The parameterization presented here is compared against the current operational model and a more recent habit mixture model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A continuous Gaussian profile matched to the fundamental mode was etched onto the aperture of a vertical cavity surface emitting laser (VCSEL). Single Gaussian spot emission was achieved over the entire operating current range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel design of 100GHz-spaced 16channel arrayed-waveguide grating (AWG) based on silica-on-silicon chip is reported.AWG is achieved by adding a Y-branch to the AWG and arranging the input/output channel in a neat row,so the whole configuration can be aligned and packaged using only one fiber-array.This configuration can decrease the device's size,enlarge the minimum radius of curvature,save time on polishing and alignment,and reduce the chip's fabrication cost.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel spectroscopic method, incoherent broadband cavity enhanced absorption spectroscopy (IBBCEAS), has been modified and extended to measure absorption spectra in the near-ultraviolet with high sensitivity. The near-ultraviolet region extends from 300 to 400 nm and is particularly important in tropospheric photochemistry; absorption of near-UV light can also be exploited for sensitive trace gas measurements of several key atmospheric constituents. In this work, several IBBCEAS instruments were developed to record reference spectra and to measure trace gas concentrations in the laboratory and field. An IBBCEAS instrument was coupled to a flow cell for measuring very weak absorption spectra between 335 and 375 nm. The instrument was validated against the literature absorption spectrum of SO2. Using the instrument, we report new absorption cross-sections of O3, acetone, 2-butanone, and 2-pentanone in this spectral region, where literature data diverge considerably owing to the extremely weak absorption. The instrument was also applied to quantifying low concentrations of the short-lived radical, BrO, in the presence of strong absorption by Br2 and O3. A different IBBCEAS system was adapted to a 4 m3 atmosphere simulation chamber to record the absorption cross-sections of several low vapour pressure compounds, which are otherwise difficult to measure. Absorption cross-sections of benzaldehyde and the more volatile alkyl nitrites agree well with previous spectra; on this basis, the cross-sections of several nitrophenols are reported for the first time. In addition, the instrument was also used to study the optical properties of secondary organic aerosol formed following the photooxidation of isoprene. An extractive IBBCEAS instrument was developed for detecting HONO and NO2 and had a sensitivity of about 10-9 cm-1. This instrument participated in a major international intercomparison of HONO and NO2 measurements held in the EUPHORE simulation chamber in Valencia, Spain, and results from that campaign are also reported here.