810 resultados para roofing materials
Resumo:
The research was developed to evaluate the use of different types of roofing materials regularly used in poultry houses. Measurements of thermal comfort were made through the use of techniques such as the Black Globe and Humidity Index (BGHI), the Thermal Heat Load (THL) and Enthalpy (H). Conducted in the State University of Goiás, during the months of April and May, 2011, the experiment was composed of five different treatments: AC - Asbestos cement tiles, BA -Bamboo tiles, BAP - Bamboo tiles painted in white, FB -Vegetable fiber tiles and bitumen, FBP -Vegetable fiber tiles and bitumen painted in white. The experiment consisted in 15 repetitions, which were considered the different days of measurements taken. Throughout the studied period, the time of the day considered the least comfortable was the one observed at 2:00pm, and the coverage of vegetable fiber and bitumen showed the highest value of BGHI (84.1) when compared to other types of coverage, characterizing a situation of lower thermal comfort, and no difference was found for THL and H on treatments in the studied region.
Resumo:
The present study was conducted at the Department of Rural Engineering and the Department of Animal Morphology and Physiology of FCAV/Unesp, Jaboticabal, SP, Brazil. The objective was to verify the influence of roof slope, exposure and roofing material on the internal temperature of reduced models of animal production facilities. For the development of the research, 48 reduced and dissemble models with dimensions 1.00 × 1.00 × 0.50 m were used. The roof was shed-type, and the models faced to the North or South directions, with 24 models for each side of exposure. Ceramic, galvanized-steel and fibro tiles were used to build the roofs. Slopes varied between 20, 30, 40 and 50% for the ceramic tile and 10, 30, 40 and 50% for the other two. Inside the models, temperature readings were performed at every hour, for 12 months. The results were evaluated in a general linear model in a nested 3 × 4 × 2 factorial arrangement, in which the effects of roofing material and exposure were nested on the factor Slope. Means were compared by the Tukey test at 5% of probability. After analyzing the data, we observed that with the increase in the slope and exposure to the South, there was a drop in the internal temperature within the model at the geographic coordinates of Jaboticabal city (SP/Brazil).
Resumo:
ABSTRACTThe current study aimed to evaluate the influence of three colors and two types of roofing materials under the internal temperature of bee colonies Apis mellifera. The experiment was conducted at the Agricultural Sciences Campus at the Federal University of Sao Francisco Valley located in Petrolina-PE, in November and December 2013, using 24 colonies housed in Langstroth hives. The experiment was a completely randomized factorial design (3x2) with three colors of box (blue, white, and traditional) and two types of cover (with and without the use of plaster) with six treatments and four replications. The internal temperature dates of the colonies were hourly recorded, during 24 hours, and surface temperatures were hourly recorded between 08h00 and 17h00. The highest values for surface and internal temperature were registered in the blue painted boxes without the use of plasterboard, and the blue painted boxes covered with plasterboard respectively. However, the lowest values were found in the white painted hives and hives that have not received the plasterboard. It is recommended to paint boxes with bright colors, and the use of plasterboard had no effect in reducing the internal temperature.
Resumo:
Esta pesquisa foi conduzida com o objetivo de avaliar diferentes tipos de coberturas em instalações para aves, por meio do Índice de Temperatura de Globo Negro e Umidade (ITGU), Carga Térmica de Radiação (CTR) e Entalpia (H). O experimento foi conduzido na Universidade Estadual de Goiás, entre os meses de abril e maio de 2011, sendo composto por cinco tratamentos (coberturas): CA -Telha de cimento-amianto; BA -Telha de bambu; BAP -Telha de bambu pintada de branco; FB -Telha de fibra vegetal e betume; FBP -Telha de fibra vegetal e betume pintada de branco, com 15 repetições, sendo as repetições os dias de medição. Dentre os horários estudados, o considerado menos confortável foi às 14h, sendo que a cobertura de fibra vegetal e betume foi a que apresentou maior valor de ITGU (84,1) quando comparada às demais coberturas, caracterizando uma situação de menor conforto térmico, não sendo observada diferença para CTR e H entre os tratamentos na região estudada.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Roofing provides the main protection against direct solar radiation in animal housing. Appropriate thermal properties of roofing materials tend to improve the thermal comfort in the inner ambient. Nonasbestos fiber-cement roofing components reinforced with cellulose pulp from sisal (Agave sisalana) were produced by slurry and dewatering techniques, with an optional addition of polypropylene fibers. Nonasbestos tiles were evaluated and compared with commercially available asbestos-cement sheets and ceramic tiles (frequently chosen as roofing materials for animal housing). Thermal conductivity and thermal diffusivity of tiles were determined by the parallel hot-wire method, along with the evaluation of the downside surface temperature. Cement-based components reinforced with sisal pulp presented better thermal performance at room temperature (25ºC), while those reinforced with sisal pulp added by polypropylene fibers presented better thermal performance at 60ºC. Non-asbestos cement tiles provided more efficient protection against radiation than asbestos corrugated sheets.
Resumo:
Widespread damage to roofing materials (such as tiles and shingles) for low-rise buildings, even for weaker hurricanes, has raised concerns regarding design load provisions and construction practices. Currently the building codes used for designing low-rise building roofs are mainly based on testing results from building models which generally do not simulate the architectural features of roofing materials that may significantly influence the wind-induced pressures. Full-scale experimentation was conducted under high winds to investigate the effects of architectural details of high profile roof tiles and asphalt shingles on net pressures that are often responsible for damage to these roofing materials. Effects on the vulnerability of roofing materials were also studied. Different roof models with bare, tiled, and shingled roof decks were tested. Pressures acting on both top and bottom surfaces of the roofing materials were measured to understand their effects on the net uplift loading. The area-averaged peak pressure coefficients obtained from bare, tiled, and shingled roof decks were compared. In addition, a set of wind tunnel tests on a tiled roof deck model were conducted to verify the effects of tiles' cavity internal pressure. Both the full-scale and the wind tunnel test results showed that underside pressure of a roof tile could either aggravate or alleviate wind uplift on the tile based on its orientation on the roof with respect to the wind angle of attack. For shingles, the underside pressure could aggravate wind uplift if the shingle is located near the center of the roof deck. Bare deck modeling to estimate design wind uplift on shingled decks may be acceptable for most locations but not for field locations; it could underestimate the uplift on shingles by 30-60%. In addition, some initial quantification of the effects of roofing materials on wind uplift was performed by studying the wind uplift load ratio for tiled versus bare deck and shingled versus bare deck. Vulnerability curves, with and without considering the effects of tiles' cavity internal pressure, showed significant differences. Aerodynamic load provisions for low-rise buildings' roofs and their vulnerability can thus be more accurately evaluated by considering the effects of the roofing materials.
Resumo:
Artificial ecotopes of 121 peridomiciliary environments in four rural localities in the state of Ceará, Brazil, were studied and the type of material of the ecotopes was identified as triatomine infestation. Two thousand two hundred and four Triatoma brasiliensis Neiva, 340 Triatoma pseudomaculata Corrêa and Espínola, 121 Rhodnius nasutus Stall, and 5 Panstrongylus lutzi (Neiva and Pinto) were captured. Out of the 323 ecotopes found (X =2.0 ± 1.8 per dwelling) such as pigpens, henhouses, corrals, perches, dovecotes, piles of roofing tiles, bricks, wood, and straw 30.3% were infested by triatomines in all different developmental stages, including eggs. A substantial number of triatomines were found in perches, however the largest infestation took place in roofing materials used in the construction of goat/sheep corrals, henhouses, and pigpens, where 98% of them were captured: 1372 triatomines were located in the roofing tile covers, 285 in the straw, 187 in the perches, 77 in the coverings of roofing tiles and straw, and 13 in the straw and wood. Among all the different pile of materials, roofing tiles were the most infested (50%) followed by bricks (38.9%) and woods (36.1%). T. brasiliensis colonized mainly brick piles (chi2=16.539; p < 0.05) and roofing tiles (chi2=5,090.58; p < 0.05); T. pseudomaculata preferred wood perches (chi2= 472.39; p < 0.05) and woodpiles (chi2=126.0 p < 0.05), and R. nasutus was principally found in roofing straw (chi2=384.43; p < 0.05). These findings suggest that triatomines tend to colonize peridomiciliary ecotopes similar to their original habitats.
Resumo:
ABSTRACT The objective of this research was to evaluate the thermal efficiency of roofs used on individual shelters during milk-feeding stage of Girolando calves. The research was conducted at a farm located in a dry region of Pernambuco state, Brazil. The experimental design was completely randomized, with 27 Holstein × Gir dairy crossbred calves housed in shelters with three roofing materials (fibre cement tile, recycled tile, and thatched roofs). The recycled tiles and thatched roofs provided reductions of 18.7 and 14.6% in radiant thermal load, respectively. Regardless the roofing material, all animals increased their respiratory rate to maintain thermal equilibrium.
Resumo:
The Johns-Manville Company was founded in 1901with the merging of the H.W. Johns Manufacturing Company and the Manville Covering Company. Both companies made building materials using asbestos. The new company was based in New York, New York, and made products such as insulation and roofing materials, automotive sheet packing for cylinders, asbestos/cement, acoustical and magnesia products. Significant restructuring has occurred over the years as the company shifted from production of asbestos products to other types of building materials, such as fibre glass and forest products. Since 2001, the Johns-Manville Company has been owned by Berkshire Hathaway. The company began operations in Canada in 1918 in Asbestos, Quebec, where the Jeffrey Asbestos Mine was located. A Canadian plant opened in Port Union, Scarborough Township, in 1956, and another in North Bay, Ontario, in 1957. Both of these plants have since closed. The company currently has two plants in Canada, in Innisfail, Alberta, and Cornwall, Ontario.
Resumo:
This paper assesses the potential for using building integrated photovoltaic (BIPV) roof shingles made from triple-junction amorphous silicon (3a-Si) for electrification and as a roofing material in tropical countries, such as Accra, Ghana. A model roof was constructed using triple-junction amorphous (3a-Si) PV on one section and conventional roofing tiles on the other. The performance of the PV module and tiles were measured, over a range of ambient temperatures and solar irradiance. PVSyst (a computer design software) was used to determine the most appropriate angle of tilt. It was observed that 3a-Si performs well in conditions such as Accra, because it is insensitive to high temperatures. Building integration gives security benefits, and reduces construction costs and embodied energy, compared to freestanding PV systems. Again, it serves as a means of protection from salt spray from the oceans and works well even when shaded. However, compared to conventional roofing materials, 3a-Si would increase the indoor temperature by 1-2 °C depending on the surface area of the roof covered with the PV modules. The results presented in this research enhance the understanding of varying factors involved in the selection of an appropriate method of PV installation to offset the short falls of the conventional roofing material in Ghana.
Resumo:
The objective of this research was to evaluate the thermal efficiency of roofs used on individual shelters during milk-feeding stage of Girolando calves. The research was conducted at a farm located in a dry region of Pernambuco state, Brazil. The experimental design was completely randomized, with 27 Holstein × Gir dairy crossbred calves housed in shelters with three roofing materials (fibre cement tile, recycled tile, and thatched roofs). The recycled tiles and thatched roofs provided reductions of 18.7 and 14.6% in radiant thermal load, respectively. Regardless the roofing material, all animals increased their respiratory rate to maintain thermal equilibrium.
Resumo:
In order to achieve sustainability it is necessary to balance the interactions between the built and natural environment. Biodiversity plays an important part towards sustainability within the built environment, especially as the construction industry comes under increasing pressure to take ecological concerns into account. Bats constitute an important component of urban biodiversity and several species are now highly dependent on buildings, making them particularly vulnerable to anthropogenic and environmental changes. As many buildings suitable for use as bat roosts age, they often require re-roofing and traditional bituminous roofing felts are frequently being replaced with breathable roofing membranes (BRMs), which are designed to reduce condensation. Whilst the current position of bats is better in many respects than 30 years ago, new building regulations and modern materials, may substantially reduce the viability of existing roosts. At the same time building regulations require that materials be fit for purpose and with anecdotal evidence that both bats and BRMs may experience problems when the two interact, it is important to know what roost characteristics are essential for house dwelling bats and how these and BRMs may be affected. This paper reviews current literature and knowledge and considers the possible ways in which bats and BRMs may interact, how this could affect existing bat roosts within buildings and the implications for BRM service life predictions and warranties. It concludes that in order for the construction and conservation sectors to work together in solving this issue, a set of clear guidelines should be developed for use on a national level.
Resumo:
In order to reduce environmental impacts and achieve sustainability, it is important to balance the interactions between the built and natural environment. The construction industry is becoming more aware of ecological concerns and the importance that biodiversity and maintenance ecosystem services has for sustainability. Bats constitute an important component of urban biodiversity and several species in the UK are highly dependent on buildings, making them particularly vulnerable to anthropogenic and environmental changes. Many buildings suitable for use as bat roosts often require re-roofing as they age and traditional bituminous roofing felts are frequently being replaced with breathable roofing membranes (BRMs). In the UK new building regulations and modern materials may substantially reduce the viability of existing roosts, yet at thesame time building regulations require that materials be fit for purpose. Reports suggest that both bats and BRMs may experience problems when the two interact. Such information makes it important to understand how house dwelling bats and BRMs may be affected. This paper considers the possible ways in which bats and BRMs may interact, how this could affect existing bat roosts within buildings and the implications for BRM service life predictions and warranties. Keywords –Breathable Roofing Membranes, Bats in Buildings, Material Deterioration, Sustainability, Conservation, Biodiversit
Resumo:
The objective of the present work was to evaluate the effects of 14 years of weathering exposition on the microstructure and mineral composition of cementitious roofing tiles, still in service, reinforced with fique fibres (Furcrae gender). The results show that tiles under weathering exposition presented higher water absorption and apparent void volume than tiles under laboratory exposition. The continuous hydration of cement and natural carbonation filled the smaller pores but contrarily the large pores remained in the porous fibre to matrix interface in the samples exposed to weathering. On the other hand, their microstructure presented lower air permeability than samples aged in the internal environment of the laboratory. Besides, in the weathering aged tiles takes place a more intensive hydration process as it was identified greater amount of hydrated phases than in the laboratory aged specimens. The present results contribute to understanding the consequences of tropical weathering on the fibre-cement degradation. (C) 2010 Elsevier Ltd. All rights reserved.