892 resultados para remote control of CNC


Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the last few years, the evolution of fieldbus and computers networks allowed the integration of different communication systems involving both production single cells and production cells, as well as other systems for business intelligence, supervision and control. Several well-adopted communication technologies exist today for public and non-public networks. Since most of the industrial applications are time-critical, the requirements of communication systems for remote control differ from common applications for computer networks accessing the Internet, such as Web, e-mail and file transfer. The solution proposed and outlined in this work is called CyberOPC. It includes the study and the implementation of a new open communication system for remote control of industrial CNC machines, making the transmission delay for time-critical control data shorter than other OPC-based solutions, and fulfilling cyber security requirements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The indication for pulmonary artery banding is currently limited by several factors. Previous attempts have failed to produce adjustable pulmonary artery banding with reliable external regulation. An implantable, telemetrically controlled, battery-free device (FloWatch) developed by EndoArt SA, a medical company established in Lausanne, Switzerland, for externally adjustable pulmonary artery banding was evaluated on minipigs and proved to be effective for up to 6 months. The first human implant was performed on a girl with complete atrioventricular septal defect with unbalanced ventricles, large patent ductus arteriosus and pulmonary hypertension. At one month of age she underwent closure of the patent ductus arteriosus and FloWatch implantation around the pulmonary artery through conventional left thoracotomy. The surgical procedure was rapid and uneventful. During the entire postoperative period bedside adjustments (narrowing or release of pulmonary artery banding with echocardiographic assessment) were repeatedly required to maintain an adequate pressure gradient. The early clinical results demonstrated the clinical benefits of unlimited external telemetric adjustments. The next step will be a multi-centre clinical trial to confirm the early results and adapt therapeutic strategies to this promising technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Remote control systems are a very useful element to control and monitor devices quickly and easily. This paper proposes a new architecture for remote control of Android mobile devices, analyzing the different alternatives and seeking the optimal solution in each case. Although the area of remote control, in case of mobile devices, has been little explored, it may provide important advantages for testing software and hardware developments in several real devices. It can also allow an efficient management of various devices of different types, perform forensic security tasks, etc ... The main idea behind the proposed architecture was the design of a system to be used as a platform which provides the services needed to perform remote control of mobile devices. As a result of this research, a proof of concept was implemented. An Android application running a group of server programs on the device, connected to the network or USB interface, depending on availability. This servers can be controlled through a small client written in Java and runnable both on desktop and web systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il presente lavoro di tesi nasce come collaborazione tra il Laboratorio di Progettazione Elettronica e il Laboratorio di Microscopia a Fluorescenza del Dipartimento di Fisica e Astronomia dell' Università di Bologna. In particolare nasce dalla volontà di dotare il dipartimento di un apparato sperimentale in grado di svolgere studi sulla Galvanotassia, un fenomeno biologico consistente nella migrazione di cellule sottoposte a stimolazione elettrica. La Galvanotassia è nota da fine '800 ma non sono ancora chiari i meccanismi cellulari che la provocano. Una migliore comprensione di tale fenomeno potrebbe portare importanti sviluppi in ambito medico, sia diagnostici che terapeutici. Dalla letteratura a riguardo non è emersa l'esistenza di apparecchi elettronici di controllo che permettano lo studio della Galvanotassia e che possano essere duttili a seconda del tipo di esperimento che si voglia svolgere. Da qui l'idea di iniziare lo sviluppo di un dispositivo elettronico, che fosse riprogrammabile, a basso costo e facilmente trasportabile. La progettazione di questo dispositivo ha portato ad una prima fase di test e verifiche sperimentali che hanno permesso di migliorare e affinare la costruzione di uno strumento di misura e controllo dei parametri relativi alla Galvanotassia. Sono già stati programmati test futuri che porteranno ad una versione definitiva dell' apparecchiatura alla quale succederanno più approfondite ricerche sul fenomeno della Galvanotassia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ubiquitous computing (one person, many computers) is the third era in the history of computing. It follows the mainframe era (many people, one computer) and the PC era (one person, one computer). Ubiquitous computing empowers people to communicate with services by interacting with their surroundings. Most of these so called smart environments contain sensors sensing users’ actions and try to predict the users’ intentions and necessities based on sensor data. The main drawback of this approach is that the system might perform unexpected or unwanted actions, making the user feel out of control. In this master thesis we propose a different procedure based on Interactive Spaces: instead of predicting users’ intentions based on sensor data, the system reacts to users’ explicit predefined actions. To that end, we present REACHeS, a server platform which enables communication among services, resources and users located in the same environment. With REACHeS, a user controls services and resources by interacting with everyday life objects and using a mobile phone as a mediator between himself/herself, the system and the environment. REACHeS’ interfaces with a user are built upon NFC (Near Field Communication) technology. NFC tags are attached to objects in the environment. A tag stores commands that are sent to services when a user touches the tag with his/her NFC enabled device. The prototypes and usability tests presented in this thesis show the great potential of NFC to build such user interfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rings shed in the Agulhas Retroflection region play an important role in the global thermohaline circulation. The shedding of these rings has been considered very irregular. In this paper, we present evidence for remote control of the timing and frequency of the ring shedding events. This turns out to be a far more regular process, at a frequency of 4–5 cycles per year. The movement of the Agulhas Retroflection, and thereby the shedding of rings, is timed by incoming eddies from the upstream regions. Eddies from the Mozambique Channel, and from the East Madagascar current reach the retroflection region at the frequency of 4–5 times per year. The existence of these eddies can be related to incoming Rossby waves that cross the Indian Ocean and reach the Agulhas Current system. These may in turn be part of a basin-wide oscillation. The irregularity found in ring shedding statistics can be ascribed to processes occurring between the actual shedding and the first unambiguous observation of a separated ring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During last decades, the Internet teleobotics has been growing at an enormous ratedue to the rapid improvement of Internet technology. This paper presents theinternet-based remote control of mobile robot. To face unpredictable Internet delaysand possible connection rupture, a direct continuous control based teleoperationarchitecture with “Speed Limit Module” (SLM) and “Delay Approximator” (DA) isproposed. This direct continuous control architecture guarantees the path error of therobot motion is restricted within the path error tolerance of the application.Experiment results show the feasibility and effectiveness of this direct Internet controlarchitecture in the real Internet environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: In areas with limited structure in place for microscopy diagnosis, rapid diagnostic tests (RDT) have been demonstrated to be effective. Method: The cost-effectiveness of the Optimal (R) and thick smear microscopy was estimated and compared. Data were collected on remote areas of 12 municipalities in the Brazilian Amazon. Data sources included the National Malaria Control Programme of the Ministry of Health, the National Healthcare System reimbursement table, hospitalization records, primary data collected from the municipalities, and scientific literature. The perspective was that of the Brazilian public health system, the analytical horizon was from the start of fever until the diagnostic results provided to patient and the temporal reference was that of year 2006. The results were expressed in costs per adequately diagnosed cases in 2006 U. S. dollars. Sensitivity analysis was performed considering key model parameters. Results: In the case base scenario, considering 92% and 95% sensitivity for thick smear microscopy to Plasmodium falciparum and Plasmodium vivax, respectively, and 100% specificity for both species, thick smear microscopy is more costly and more effective, with an incremental cost estimated at US$ 549.9 per adequately diagnosed case. In sensitivity analysis, when sensitivity and specificity of microscopy for P. vivax were 0.90 and 0.98, respectively, and when its sensitivity for P. falciparum was 0.83, the RDT was more cost-effective than microscopy. Conclusion: Microscopy is more cost-effective than OptiMal (R) in these remote areas if high accuracy of microscopy is maintained in the field. Decision regarding use of rapid tests for diagnosis of malaria in these areas depends on current microscopy accuracy in the field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new communication architecture to enable the remote control, monitoring and debug of embedded-system controllers designed using IOPT Petri nets. IOPT Petri nets and the related tools (http://gres.uninova.pt) have been used as a rapid prototyping and development framework, including model-checking, simulation and automatic code generation tools. The new architecture adds remote operation capabilities to the controllers produced by the automatic code generators, enabling quasi-real-time remote debugging and monitoring using the IOPT simulator tool. Furthermore, it enables the creation of graphical user interfaces for remote operation and the development of distributed systems where a Petri net model running on a central system supervises the actions of multiple remote subsystems. © 2015 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Urinary schistosomiasis remains a significant burden for Africa and the Middle East. The success of population-based control programs will depend on their impact, over many years, on Schistosoma haematobium reinfection and associated disease. In a multi-year (1984-1992) control program in Kenya, we examined risk for S. haematobium reinfection and late disease during and after annual school-based treatment. In this setting, long-term risk of new infection was independently associated with location, age, hematuria, and incomplete treatment, but not with sex or frequency of water contact. Thus, very local environmental features and age-related factors played an important role in S. haematobium transmission, such that population-based control programs should optimally tailor their efforts to local conditions on a village-by-village basis. In 2001-2002, the late benefits of earlier participation in school-based antischistosomal therapy were estimated in a cohort of formerly-treated adult residents compared to never-treated adults from the same villages. Among age-matched subjects, current infection prevalence was lower among those who had received remote therapy. In addition, prevalence of bladder abnormality was lower in the treated group, who were free of severe bladder disease. Treatment of affected adults resulted in rapid resolution of infection and any detectable bladder abnormalities. We conclude that continued treatment into adulthood, as well as efforts at long-term prevention of infection (transmission control) are necessary to achieve optimal morbidity control in affected communities.