958 resultados para radius fractures


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Distal radius fractures stabilized by open reduction internal fixation (ORIF) have become increasingly common. There is currently no consensus on the optimal time to commence range of motion (ROM) exercises post-ORIF. A retrospective cohort review was conducted over a five-year period to compare wrist and forearm range of motion outcomes and number of therapy sessions between patients who commenced active ROM exercises within the first seven days and from day eight onward following ORIF of distal radius fractures. One hundred and twenty-one patient cases were identified. Clinical data, active ROM at initial and discharge therapy assessments, fracture type, surgical approaches, and number of therapy sessions attended were recorded. One hundred and seven (88.4%) cases had complete datasets. The early active ROM group (n = 37) commenced ROM a mean (SD) of 4.27 (1.8) days post-ORIF. The comparator group (n = 70) commenced ROM exercises 24.3 (13.6) days post-ORIF. No significant differences were identified between groups in ROM at initial or discharge assessments, or therapy sessions attended. The results from this study indicate that patients who commenced active ROM exercises an average of 24 days after surgery achieved comparable ROM outcomes with similar number of therapy sessions to those who commenced ROM exercises within the first week.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To examine the relative effectiveness of ice therapy and/or pulsed electromagnetic field in reducing pain and swelling after the immobilization period following a distal radius fracture.Methods: A total of 83 subjects were randomly allocated to receive 30 minutes of either ice plus pulsed electromagnetic field (group A); ice plus sham pulsed electromagnetic field (group B); pulsed electromagnetic field alone (group C), or sham pulsed electromagnetic field treatment for 5 consecutive days (group D). All subjects received a standard home exercise programme. A visual analogue scale was used for recording pain; volumetric displacement for measuring the swelling of the forearm; and a hand-held goniometer for measuring the range of wrist motions before treatment on days 1, 3 and 5.Results: At day 5, a significantly greater cumulative reduction in the visual analogue scores as well as ulnar deviation range of motion was found in group A than the other 3 groups. For volumetric measurement and pronation, participants in group A performed better than subjects in group D but not those in group B.Conclusion: The addition of pulsed electromagnetic field to ice therapy produces better overall treatment outcomes than ice alone, or pulsed electromagnetic field alone in pain reduction and range of joint motion in ulnar deviation and flexion for a distal radius fracture after an immobilization period of 6 weeks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: We sought to compare the diagnostic performance of screen-film radiography, storage-phosphor radiography, and a flat-panel detector system in detecting forearm fractures and to classify distal radius fractures according to the Müller-AO and Frykman classifications compared with the true extent, depicted by anatomic preparation. MATERIALS AND METHODS: A total of 71 cadaver arms were fractured in a material testing machine creating different fractures of the radius and ulna as well as of the carpal bones. Radiographs of the complete forearm were evaluated by 3 radiologists, and anatomic preparation was used as standard of reference in a receiver operating curve analysis. RESULTS: The highest diagnostic performance was obtained for the detection of distal radius fractures with area under the receiver operating curve (AUC) values of 0.959 for screen-film radiography, 0.966 for storage-phosphor radiography, and 0.971 for the flat-panel detector system (P > 0.05). Exact classification was slightly better for the Frykman (kappa values of 0.457-0.478) compared with the Müller-AO classification (kappa values of 0.404-0.447), but agreement can be considered as moderate for both classifications. CONCLUSIONS: The 3 imaging systems showed a comparable diagnostic performance in detecting forearm fractures. A high diagnostic performance was demonstrated for distal radius fractures and conventional radiography can be routinely performed for fracture detection. However, compared with anatomic preparation, depiction of the true extent of distal radius fractures was limited and the severity of distal radius fractures tends to be underestimated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The first objective of this study was to determine normative digital X-ray radiogrammetry (DXR) values, based on original digital images, in a pediatric population (aged 6-18 years). The second aim was to compare these reference data with patients suffering from distal radius fractures, whereas both cohorts originated from the same geographical region and were evaluated using the same technical parameters as well as inclusion and exclusion criteria. DXR-BMD and DXR-MCI of the metacarpal bones II-IV were assessed on standardized digital hand radiographs, without printing or scanning procedures. DXR parameters were estimated separately by gender and among six age groups; values in the fracture group were compared to age- and gender-matched normative data using Student's t tests and Z scores. In the reference cohort (150 boys, 138 girls), gender differences were found in bone mineral density (DXR-BMD), with higher values for girls from 11 to 14 years and for boys from 15 to 18 years (p < 0.05). Girls had higher normative metacarpal index (DXR-MCI) values than boys, with significant differences at 11-14 years (p < 0.05). In the case-control investigation, the fracture group (95 boys, 69 girls) presented lower DXR-BMD at 15-18 years in boys and 13-16 years in girls vs. the reference cohort (p < 0.05); DXR-MCI was lower at 11-18 years in boys and 11-16 years in girls (p < 0.05). Mean Z scores in the fracture group for DXR-BMD were -0.42 (boys) and -0.46 (girls), and for DXR-MCI were -0.51 (boys) and -0.53 (girls). These findings indicate that the fully digital DXR technique can be accurately applied in pediatric populations ≥ 6 years of age. The lower DXR-BMD and DXR-MCI values in the fracture group suggest promising early identification of individuals with increased fracture risk, without the need for additional radiation exposure, enabling the initiation of prevention strategies to possibly reduce the incidence of osteoporosis later in life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigated the effect of pneumatic pressure applied to the proximal musculature of the sheep foreleg on load at the site of a transverse osteotomy of the distal radius. The distal radii of 10 fresh sheep foreleg specimens were osteotomized and a pressure sensor was inserted between the two bone fragments. An inflatable cuff, connected to a second pressure sensor, was positioned around the proximal forelimb musculature and the leg then was immobilized in a plaster cast. The inflatable cuff was inflated and deflated repeatedly to various pressures. Measurements of the cuff pressure and corresponding change in pressure at the osteotomy site were recorded. The results indicated that application of pneumatic pressure to the proximal foreleg musculature produced a corresponding increase in load at the osteotomy site. For the cuff pressures tested (109.8-238.4 mm Hg), there was a linear correlation with the load at the osteotomy site with a gradient of 12 mm Hg/N. It is conceivable, based on the results of this study, that a technique could be developed to provide dynamic loading to accelerate fracture healing in the upper limb of humans.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

INTRODUCTION: Currently available volar locking plates for the treatment of distal radius fractures incorporate at least two distal screw rows for fixation of the metaphyseal fragment and have a variable-angle locking mechanism which allows placement of the screws in various directions There is, however no evidence that these plates translate into better outcomes or have superior biomechanical properties to first generation plates, which had a single distal screw row and fixed-angle locking. The aim of our biomechanical study was to compare fixed-angle single-row plates with variable-angle multi-row plates to clarify the optimal number of locking screws. MATERIALS AND METHODS: Five different plate-screw combinations of three different manufacturers were tested, each group consisting of five synthetic fourth generation distal radius bones. An AO type C2 fracture was created and the fractures were plated according to each manufacturer's recommendations. The specimens then underwent cyclic and load-to-failure testing. An optical motion analysis system was used to detect displacement of fragments. RESULTS: No significant differences were detected after cyclic loading as well as after load-to-failure testing, neither in regard to axial deformation, implant rigidity or maximum displacement. The fixed-angle single-row plate showed the highest pre-test rigidity, least increase in post-testing rigidity and highest load-to-failure rigidity and least radial shortening. The radial shortening of plates with two distal screw rows was 3.1 and 4.3 times higher, respectively, than that of the fixed-angle single-row plate. CONCLUSION: The results of our study indicate that two distal screw rows do not add to construct rigidity and resistance against loss of reduction. Well conducted clinical studies based on the findings of biomechanical studies are necessary to determine the optimal number of screws necessary to achieve reproducibly good results in the treatment of distal radius fractures.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJETIVO: Investigar a influência de Proteínas Morfogenéticas Ósseas de origem bovina (bBMPs) ligadas a hidroxiapatita mais colágeno na consolidação de fraturas instáveis do rádio. MÉTODOS: em 15 coelhos com aproximadamente 5,5 meses de idade e peso médio de 3,5kg foi realizada uma fratura transversa na porção média da diáfise do rádio de ambos os membros. Na fratura do rádio direito foi aplicada mistura de bBMPs ligadas à hidroxiapatita (bBMP-HA) e colágeno bovino como aglutinante e na do rádio esquerdo, considerada controle, nenhum tratamento foi usado. Os coelhos (cinco por período) foram submetidos à eutanásia aos 30, 60 e 90 dias após a cirurgia para realização do processamento histológico e análise microscópica. RESULTADOS: A análise histológica descritiva revelou que a consolidação foi similar para os membros tratado e controle. Pela análise histomorfométrica, a área de novo osso foi em média 867442,16 mm², 938743.00 mm² e 779621,06 mm² para os membros controles e 841118,47 mm², 788038,76mm² e 618587,24 mm² para os membros tratados, aos 30, 60 e 90 dias, respectivamente. Desta forma, aos 60 dias de pós-operatório a área de novo osso foi 12.17% maior no membro tratado com bBMP-HA/colágeno em relação ao membro controle (p<0.05, teste de Tukey). em ambos os membros a área de novo osso aumentou durante o período experimental até a total consolidação da fratura. CONCLUSÃO: Baseado nos resultados obtidos foi possível concluir que a mistura de bBMP-HA/colágeno induziu pequena, porém significante melhora na consolidação da fratura.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Operative fixation of intraarticular distal radius fractures is increasingly common. A greater understanding of fracture patterns will aid surgical fixation strategy. Previous studies have suggested that ligamentous insertions may less commonly be involved, but these have included heterogeneous groups of fractures and have not addressed Lister's tubercle. Purpose We hypothesize that fracture lines of distal radial intraarticular 2-part fractures have reproducible patterns. They propagate through the cortical bone between ligament origins and do not involve Lister's tubercle. Methods Axial CT scans of two-part intraarticular distal radius fractures were assessed independently by two examiners. The fractures were mapped onto a grid and the cortical breaches expressed as a percentile of the total radial width or length. The cortical breaches were compared with the ligamentous insertions on the distal and Lister's tubercle. Associated injuries were also documented. Results The cortical breaches occurred between the ligamentous insertions in 85%. Lister's tubercle was not involved in 95% of the fractures. Three major fracture patterns emerged: radial styloid, dorsal, and volar. Each major pattern had two subtypes. Associated injuries were common. Scapholunate dissociation was associated with all types, not just the radial styloid fracture pattern. Conclusions The fracture patterns of two-part intraarticular fractures mostly involved the interligamentous zones. Three major groups were identified: dorsal, volar, and radial styloid. Lister's tubercle was preserved with fractures tending to propagate radial or ulnar to this structure. We suggest conceptualizing fracture fragments as osseo-ligamentous units to aid prediction of fracture patterns and associated injury. Study Design Diagnostic III Level of Evidence 3.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION:

Dorsally displaced fractures of the distal radius fractures are one of the commonest in day-to-day practice. There is still no consensus among surgeons regarding the suitability of using volar or the dorsal cortex as basis for internal fixation for dorsally displaced fractures.

BACKGROUND:

We report an anatomical study, which compares the thickness of the volar and dorsal cortices of cadaveric adult radii using digital photography.

RESULTS:

Results of this study show that the volar cortex was statistically, significantly thicker than the dorsal cortex. We believe that the volar cortex may behave as the calcar of the distal radius and hence internal fixation devices applied to the volar cortex may provide a more stable internal fixation compared to those based on the dorsal cortex.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El trauma de codo y la fractura de cúpula radial resultan ser un motivo de consulta frecuente en nuestro medio. Es común en nuestro medio que a pesar de tener radiografías de codo en las que se evidencia fractura de cúpula radial se solicite un TAC de codo. Consideramos que el TAC es una herramienta útil en algunos casos de fracturas de la cúpula radial, es decir, no se debe tomar de forma rutinaria el TAC de codo en los pacientes con fracturas de cúpula radial como es usual en nuestro medio. Existen pocos estudios que comparan la concordancia inter observador de las clasificaciones utilizadas para las fracturas de cúpula radial, pero, no existe en la literatura mundial un estudio que evalué las diferencias entre la clasificación de la fractura en base a radiografías y tomografía entre un grupo ortopedistas traumatólogos y sub-especialistas de miembro superior. La realización de este estudio permite elaborar guías de manejo de pacientes con fractura de cúpula radial en la que se racionalizara el uso del TAC de codo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Las fracturas de la cúpula radial corresponden a un tercio de todas las fracturas del codo en adultos (1), por lo que se toman radiografías o tomografías, sin embargo no existe literatura que soporte la realización de la tomografía como estudio complementario, por lo que preguntamos ¿La tomografía de codo cambia la conducta tomada previamente con radiografía en fracturas de cúpula radial? Se propone un estudio de concordancia, donde se evalúan las radiografías y tomografías por parte de dos cirujanos de codo, de pacientes con diagnóstico de fractura de cúpula radial valorados en urgencias de dos hospitales de tercer nivel de Bogotá desde enero 2011 a enero 2013. Se revisaron 116 historias, 99 cumplieron los criterios, las radiografías fueron revisadas por dos ortopedistas de codo quienes realizaron clasificación de Mason obteniendo un κ 1 (p˂ 0,00), propuesta de tratamiento postradiografía κ 0,934 (p˂ 0,000 IC95% 0.85, 1). Tratamiento post-tomografía de codo κ 0.949 (p˂ 0,00 IC95% 0.867,1). Concordancia intra-ortopedista de la conducta pre y post-tomografía hay cambio en la conducta del ortopedista 1 en 32.6% (κ 0.674 p˂ 0,00 IC95% 0.52, 0.818) y del ortopedista 2 en 36% (κ 0.64 p˂ 0,00 IC95% 0.452, 0.792). Se dividieron los pacientes en Mason I, II, III con concordancia considerable en los pacientes Mason I y III, mientras que en Mason II fue una concordancia aceptable lo que significa que el uso de tomografía de codo cambia la conducta en general pero sobretodo en pacientes clasificados Masson II.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introducción: La utilidad de la tomografía computarizada como prueba de rutina en la toma de decisiones para las fracturas de radio distal no ha sido bien establecida. Metodología: Estudio de concordancia intra e interobservador en el tratamiento de fracturas de radio distal Fernández V. Se realizaron dos visitas, con intervalo de 2 semanas entre ellas a 15 ortopedistas de trauma quienes evaluaron 22 radiografías de muñeca y sus respectivas tomografías con fracturas de radio distal Fernández V, determinaron para cada caso la mejor opción de tratamiento. Se utilizó el coeficiente Kappa para evaluar la concordancia intra e interobservador para el plan de tratamiento propuesto y se analizaron los resultados según la interpretación de este coeficiente según Landis y Koch. Resultados: La concordancia entre radiografía y tomografía fue moderada kappa 0,47 – 0,51 en las dos evaluaciones respectivamente, manteniéndose el cambio de tratamiento entre 24,9% y 26,7% (p‹0,001). La concordancia observada intraobservador para radiografía y tomografía evaluadas de manera individual fue buena (72,1% y 64,2% respectivamente) evidenciándose cambio en la decisión de tratamiento hasta en el 35,8% de las evaluaciones (p‹0,001); se determinó concordancia observada muy buena en los casos a los que se propuso manejo abierto. No se identificó influencia de la edad en la decisión de tratamiento. Conclusiones: Existe buena concordancia entre radiografía simple y tomografía en fracturas de radio distal Fernández V en cuanto a la decisión de tratamiento, siendo alta la concordancia en los casos en los que se decide manejo abierto.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La osteoporosis es una de las condiciones patológicas en mayor crecimiento a medida que la población de tercera edad aumenta, esto se traduce en fracturas por fragilidad como lo son las fracturas de radio distal y las fracturas de cadera, actualmente no se cuentas con datos de la población a estudio que correlacione este tipo de fracturas. Es un estudio retrospectivo de casos y controles donde se obtuvo un grupo de pacientes con fractura de cadera que consultaron a un hospital universitario de alta complejidad en la ciudad de Bogotá, se evaluó la presencia de antecedente de fractura de radio distal y se comparó con un grupo control de trauma en cadera. Se obtuvo un total de 325 casos (72,5%) y 123 (25%) controles. El promedio de edad fue de 81 años, el 70% de los pacientes en ambos grupos correspondió a mujeres. No hubo diferencia en cuanto a la prevalencia de tabaquismo, hipertensión arterial o diabetes en los grupos. No se encontraron diferencias significativas en cuanto a niveles de glicemia, calcio, vitamina D. La presencia de antecedente de fractura de radio distal en grupo con fractura de cadera fue del 7,1% encontrando un OR de 3,91 IC 95%(1,17– 13,10). La presencia de fractura de radio distal como antecedente es un predictor para la fractura de cadera en pacientes mayores. Se necesitan más estudios que correlacionen otras variables que pueden influir en la asociación para fractura de cadera y radio, para así identificar una población específica que se beneficie de un tratamiento temprano.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The Broberg and Morrey modification of the Mason classification of radial head fractures has substantial interobserver variation. This study used a large web-based collaborative of experienced orthopaedic surgeons to test the hypothesis that three-dimensional reconstructions of computed tomography (CT) scans improve the interobserver reliability of the classification of radial head fractures according to the Broberg and Morrey modification of the Mason classification.

Methods: Eighty-five orthopaedic surgeons evaluated twelve radial head fractures. They were randomly assigned to review either radiographs and two-dimensional CT scans or radiographs and three-dimensional CT images to determine the fracture classification, fracture characteristics, and treatment recommendations. The kappa multirater measure (κ) was calculated to estimate agreement between observers.

Results: Three-dimensional CT had moderate agreement and two-dimensional CT had fair agreement among observers for the Broberg and Morrey modification of the Mason classification, a difference that was significant. Observers assessed seven fracture characteristics, including fracture line, comminution, articular surface involvement, articular step or gap of ≥2 mm, central impaction, recognition of more than three fracture fragments, and fracture fragments too small to repair. There was a significant difference in kappa values between three-dimensional CT and two-dimensional CT for fracture fragments too small to repair, recognition of three fracture fragments, and central impaction. The difference between the other four fracture characteristics was not significant. Among treatment recommendations, there was fair agreement for both three-dimensional CT and two-dimensional CT.

Conclusions: Although three-dimensional CT led to some small but significant decreases in interobserver variation, there is still considerable disagreement regarding classification and characterization of radial head fractures. Three-dimensional CT may be insufficient to optimize interobserver agreement.