996 resultados para pumping efficiency


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS While zebrafish embryos are amenable to in vivo imaging, allowing the study of morphogenetic processes during development, intravital imaging of adults is hampered by their small size and loss of transparency. The use of adult zebrafish as a vertebrate model of cardiac disease and regeneration is increasing at high speed. It is therefore of great importance to establish appropriate and robust methods to measure cardiac function parameters. METHODS AND RESULTS Here we describe the use of 2D-echocardiography to study the fractional volume shortening and segmental wall motion of the ventricle. Our data show that 2D-echocardiography can be used to evaluate cardiac injury and also to study recovery of cardiac function. Interestingly, our results show that while global systolic function recovered following cardiac cryoinjury, ventricular wall motion was only partially restored. CONCLUSION Cryoinjury leads to long-lasting impairment of cardiac contraction, partially mimicking the consequences of myocardial infarction in humans. Functional assessment of heart regeneration by echocardiography allows a deeper understanding of the mechanisms of cardiac regeneration and has the advantage of being easily transferable to other cardiovascular zebrafish disease models.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Output beam quality of edge pumped planar waveguide lasers with confocal unstable resonators is investigated by diffraction methods, taking into account gain saturation, asymmetric pumping, and beam interaction. The influences of pumping uniformity, doping concentration, cavity length and effective Fresnel number are analyzed with respect to output beam quality and pumping efficiency. It is found that good beam quality and high efficiency can be obtained with asymmetric pumping and optimized negative branch confocal unstable resonators. (c) 2005 The Optical Society of Japan.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

用提拉法成功地生长了6mol%的高浓度掺铒铌酸锂晶体。测量了晶体的两个非偏振方向(X和Z)以及两个偏振方向(π和δ)的吸收光谱。高浓度掺铒铌酸锂晶体的吸收系数高,有利于提高泵浦效率。根据所测的吸收光谱用Judd-Ofelt理论拟合出了Er^3+离子的强度参数Ωλ。所得的均方差结果显示偏振拟合的误差要小于非偏振拟合。利用偏振吸收数据计算了各能级跃迁的自发辐射跃迁几率(AJJ’)、辐射寿命(τ)、荧光分支比(β)和积分发射截面(σp)等参数,对计算结果进行了讨论并与其他文献的报道结果进行了比较。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a low-voltage, high performance charge pump circuit suitable for implementation in standard CMOS technologies. The proposed charge pump has been used as a part of the power supply section of fully integrated passive radio frequency identification(RFID) transponder IC, which has been implemented in a 0.35-um CMOS technology with embedded EEPROM offered by Chartered Semiconductor. The proposed DC/DC charge pump can generate stable output for RFID applications with low power dissipation and high pumping efficiency. The analytical model of the voltage multiplier, the comparison with other charge pumps, the simulation results, and the chip testing results are presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An ultra low power non-volatile memory is designed in a standard CMOS process for passive RFID tags. The memory can operate in a new low power operating scheme under a wide supply voltage and clock frequency range. In the charge pump circuit the threshold voltage effect of the switch transistor is almost eliminated and the pumping efficiency of the circuit is improved. An ultra low power 192-bit memory with a register array is implemented in a 0.18 mu M standard CMOS process. The measured results indicate that, for the supply voltage of 1.2 volts and the clock frequency of 780KHz, the current consumption of the memory is 1.8 mu A (3.6 mu A) at the read (write) rate of 1.3Mb/s (0.8Kb/s).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a power supply solution for fully integrated passive radio-frequency identification(RFID) transponder IC,which has been implemented in 0.35μm CMOS technology with embedded EEPROM from Chartered Semiconductor.The proposed AC/DC and DC/DC charge pumps can generate stable output for RFID applications with quite low power dissipation and extremely high pumping efficiency.An analytical model of the voltage multiplier,comparison with other charge pumps,simulation results,and chip testing results are presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The oil industry uses gas separators in production wells as the free gas present in the suction of the pump reduces the pumping efficiency and pump lifetime. Therefore, free gas is one of the most important variables in the design of pumping systems. However, in the literature there is little information on these separators. It is the case of the inverted-shroud gravitational gas separator. It has an annular geometry due to the installation of a cylindrical container in between the well casing and pioduction pipe (tubing). The purpose of the present study is to understand the phenomenology and behavior of inverted-shroud separator. Experimental tests were performed in a 10.5-m-length inclinable glass tube with air and water as working fluids. The water flow rate was in the range of 8.265-26.117 l/min and the average inlet air mass flow rate was 1.1041 kg/h, with inclination angles of 15 degrees, 30 degrees, 45 degrees, 60 degrees, 75 degrees, 80 degrees and 85 degrees. One of the findings is that the length between the inner annular level and production pipe inlet is one of the most important design parameters and based on that a new criterion for total gas separation is proposed. We also found that the phenomenology of the studied separator is not directly dependent on the gas flow rate, but on the average velocity of the free surface flow generated inside the separator. Maps of efficiency of gas separation were plotted and showed that liquid flow rate, inclination angle and pressure difference between casing and production pipe outlet are the main variables related to the gas separation phenomenon. The new data can be used for the development of design tools aiming to the optimized project of the pumping system for oil production in directional wells. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The H+/ATP ratio in the catalysis of ATP synthase has generally been considered a fixed parameter. However, Melandri and coworkers have recently shown that, in the ATP synthase of the photosynthetic bacterium Rb.capsulatus, this ratio can significantly decrease during ATP hydrolysis when the concentration of either ADP or Pi is maintained at a low level (Turina et al., 2004). The present work has dealt with the ATP synthase of E.coli, looking for evidence of this phenomenon of intrinsic uncoupling in this organism as well. First of all, we have shown that the DCCD-sensitive ATP hydrolysis activity of E.coli internal membranes was strongly inhibited by ADP and Pi, with a half-maximal effect in the submicromolar range for ADP and at 140 µM for Pi. In contrast to this monotonic inhibition, however, the proton pumping activity of the enzyme, as estimated under the same conditions by the fluorescence quenching of the ΔpH-sensitive probe ACMA, showed a clearly biphasic progression, both for Pi, increasing from 0 up to approximately 200 µM, and for ADP, increasing from 0 up to a few µM. We have interpreted these results as indicating that the occupancy of ADP and Pi binding sites shifts the enzyme from a partially uncoupled state to a fully coupled state, and we expect that the ADP- and Pi-modulated intrinsic uncoupling is likely to be a general feature of prokaryotic ATP synthases. Moreover, the biphasicity of the proton pumping data suggested that two Pi binding sites are involved. In order to verify whether the same behaviour could be observed in the isolated enzyme, we have purified the ATP synthase of E.coli and reconstituted it into liposomes. Similarly as observed in the internal membrane preparation, in the isolated and reconstituted enzyme it was possible to observe inhibition of the hydrolytic activity by ADP and Pi (with half-maximal effects at few µM for ADP and at 400 µM for Pi) with a concomitant stimulation of proton pumping. Both the inhibition of ATP hydrolysis and the stimulation of proton pumping as a function of Pi were lost upon ADP removal by an ADP trap. These data have made it possible to conclude that the results obtained in E.coli internal membranes are not due to the artefactual interference of enzymatic activities other than the ones of the ATP synthase. In addition, data obtained with liposomes have allowed a calibration of the ACMA signal by ΔpH transitions of known extent, leading to a quantitative evaluation of the proton pumping data. Finally, we have focused our efforts on searching for a possible structural candidate involved in the phenomenon of intrinsic uncoupling. The ε-subunit of the ATP-synthase is known as an endogenous inhibitor of the hydrolysis activity of the complex and appears to undergo drastic conformational changes between a non-inhibitory form (down-state) and an inhibitory form (up-state)(Rodgers & Wilce, 2000; Gibbons et al., 2000). In addition, the results of Cipriano & Dunn (2006) indicated that the C-terminal domain of this subunit played an important role in the coupling mechanism of the pump, and those of Capaldi et al. (2001), Suzuki et al. (2003) were consistent with the down-state showing a higher hydrolysis-to-synthesis ratio than the up-state. Therefore, we decided to search for modulation of pumping efficiency in a C-terminally truncated ε mutant. A low copy number expression vector has been built, carrying an extra copy of uncC, with the aim of generating an ε-overexpressing E.coli strain in which normal levels of assembly of the mutated ATP-synthase complex would be promoted. We have then compared the ATP hydrolysis and the proton pumping activity in membranes prepared from these ε-overexpressing E.coli strains, which carried either the WT ε subunit or the ε88-stop truncated form. Both strains yielded well energized membranes. Noticeably, they showed a marked difference in the inhibition of hydrolysis by Pi, this effect being largely lost in the truncated mutant. However, pre-incubation of the mutated enzyme with ADP at low nanomolar concentrations (apparent Kd = 0.7nM) restored the hydrolysis inhibition, together with the modulation of intrinsic uncoupling by Pi, indicating that, contrary to wild-type, during membrane preparation the truncated mutant had lost the ADP bound at this high-affinity site, evidently due to a lower affinity (and/or higher release) for ADP of the mutant relative to wild type. Therefore, one of the effects of the C-terminal domain of ε appears to be to modulate the affinity of at least one of the binding sites for ADP. The lack of this domain does not appear so much to influence the modulability of coupling efficiency, but instead the extent of this modulation. At higher preincubated ADP concentrations (apparent Kd = 117nM), the only observed effects were inhibition of both hydrolysis and synthesis, providing a direct proof that two ADP-binding sites on the enzyme are involved in the inhibition of hydrolysis, of which only the one at higher affinity also modulates the coupling efficiency.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Light-induced lipophilic porphyrin/aqueous acceptor charge separation across a single lipid-water interface can pump protons across the lipid bilayer when the hydrophobic weak acids, carbonylcyanide m-chlorophenylhydrazone and its p-trifluoromethoxyphenyl analogue, are present. These compounds act as proton carriers across lipid bilayers. In their symmetric presence across the bilayer, the positive currents and voltages produced by the photogeneration of porphyrin cations are replaced by larger negative currents and voltages. The maximum negative current and voltage occur at the pH of maximum dark conductance. The reversed larger current and voltage show a positive ionic charge transport in the same direction as the electron transfer. This transport can form an ion concentration gradient. The movement of protons is verified by an unusual D2O isotope effect that increases the negative ionic current by 2- to 3-fold. These effects suggest that an interfacial pK shift of the weak acid caused by the local electric field of photoformed porphyrin cations/acceptor anions functions as the driving force. The estimated pumping efficiency is 10-30%. Time-resolved results show that proton pumping across the bilayer occurs on the millisecond time scale, similar to that of biological pumps. This light-driven proteinless pump offers a simple model for a prebiological energy transducer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We have investigated the spin preparation efficiency by optical pumping of individual Mn atoms embedded in CdTe/ZnTe quantum dots. Monitoring the time dependence of the intensity of the fluorescence during the resonant optical pumping process in individual quantum dots allows to directly probe the dynamics of the initialization of the Mn spin. This technique presents the convenience of including preparation and readout of the Mn spin in the same step. Our measurements demonstrate that Mn spin initialization, at zero magnetic field, can reach an efficiency of 75% and occurs in the tens of nanoseconds range when a laser resonantly drives at saturation one of the quantum-dot transition. We observe that the efficiency of optical pumping changes from dot-to-dot and is affected by a magnetic field of a few tens of millitesla applied in Voigt or Faraday configuration. This is attributed to the local strain distribution at the Mn location which predominantly determines the dynamics of the Mn spin under weak magnetic field. The spectral distribution of the spin-flip-scattered photons from quantum dots presenting a weak optical pumping efficiency reveals a significant spin relaxation for the exciton split in the exchange field of the Mn spin.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pumping systems are widely used in many applications, including municipal water/wastewater services, domestic, commercial and agricultural services, and industrial processes. They are a very significant energy user and consume nearly 20% of the world’s electrical energy demand. Therefore, improving the energy efficiency of pumping systems can provide great benefits in terms of energy, environment, and cost reduction. In this entry, an overview of pump classification with pros and cons of each type of pump is presented. The procedures used to design pumping systems are also outlined. This is then followed by a discussion on the opportunities for improving the energy efficiency of pumping systems during every stage of design, selection, operation, and maintenance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this study is to improve the stability of pumping source of optical parametric amplifier. Analysis by simulation leads to the conclusion that the stability of the second harmonic can be improved by using properly the intensity of fundamental light and corresponding length of the crystal. By the method of the noncollinear two-pass second harmonic or the tandem second harmonic, the efficient crystal length is extended to a proper value, and the stability of the second harmonic output has been improved two times more than that for the fundamental light, and the conversion-efficiency is about 70% in experiment. When the variation of the fundamental light is about 10%, the variation of the second harmonic intensity has been controlled within 5%. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Neste trabalho, ajustou-se um modelo matemático para quantificar o efeito do rendimento do motor elétrico sobre os custos de um sistema de bombeamento para irrigação na estrutura tarifária de energia elétrica convencional e horo-sazonal verde, bem como calcular o tempo de recuperação do capital investido no equipamento de maior rendimento. em seguida, o mesmo foi aplicado a um sistema de irrigação tipo pivô central em duas opções de rendimento do motor elétrico: 92,6% (linha padrão) e 94,3% (linha alto rendimento), sendo que o custo de aquisição do primeiro correspondeu a 70% do segundo. A potência do motor elétrico era de 100 cv. Os resultados mostraram que o modelo permitiu avaliar se um motor de alto rendimento era viável economicamente em relação ao motor-padrão em cada estrutura tarifária. Nas duas estruturas tarifárias, o motor de alto rendimento não foi viável. Na tarifa horo-sazonal verde, somente seria viável se seu rendimento fosse 4,46% superior ao do motor-padrão. Na tarifa convencional, somente seria viável se o ganho de rendimento superasse 2,71%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Advances in metastability exchange optical pumping (MEOP) of 3He at high laser powers, with its various applications, but also at high gas pressures p3 and high magnetic field strengths B, have provided strong motivation for revisiting the understanding and for investigating the limitations of this powerful technique. For this purpose, we present systematic experimental and theoretical studies of efficiency and of relaxation mechanisms in B≤30 mT and p3=0.63−2.45 mbar. 3He nuclear polarisation is measured by light absorption in longitudinal configuration where weak light beams at 1083 nm parallel to magnetic field and cell axis with opposite circular polarisations are used to probe the distribution of populations in the metastable state. This method is systematically tested to evaluate potential systematic biases and is shown to be reliable for the study of OP dynamics despite the redistribution of populations by OP light. Nuclear polarisation loss associated to the emission of polarised light by the plasma discharge used for MEOP is found to decrease above 10 mT, as expected, due to hyperfine decoupling in highly excited states. However, this does not lead to improved MEOP efficiency at high laser power. We find clear evidence of additional laser-induced relaxation instead. The strong OP-enhanced polarisation losses, currently limiting MEOP performances, are quantitatively investigated using an angular momentum budget approach and a recently developed comprehensive model that describes the combined effects of OP, ME and relaxation, validated by comparison to experimental results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this review is to report changes in irrigated cotton water use from research projects and on-farm practice-change programs in Australia, in relation to both plant-based and irrigation engineering disciplines. At least 80% of the Australian cotton-growing area is irrigated using gravity surface-irrigation systems. This review found that, over 23 years, cotton crops utilise 6-7ML/ha of irrigation water, depending on the amount of seasonal rain received. The seasonal evapotranspiration of surface-irrigated crops averaged 729mm over this period. Over the past decade, water-use productivity by Australian cotton growers has improved by 40%. This has been achieved by both yield increases and more efficient water-management systems. The whole-farm irrigation efficiency index improved from 57% to 70%, and the crop water use index is >3kg/mm.ha, high by international standards. Yield increases over the last decade can be attributed to plant-breeding advances, the adoption of genetically modified varieties, and improved crop management. Also, there has been increased use of irrigation scheduling tools and furrow-irrigation system optimisation evaluations. This has reduced in-field deep-drainage losses. The largest loss component of the farm water balance on cotton farms is evaporation from on-farm water storages. Some farmers are changing to alternative systems such as centre pivots and lateral-move machines, and increasing numbers of these alternatives are expected. These systems can achieve considerable labour and water savings, but have significantly higher energy costs associated with water pumping and machine operation. The optimisation of interactions between water, soils, labour, carbon emissions and energy efficiency requires more research and on-farm evaluations. Standardisation of water-use efficiency measures and improved water measurement techniques for surface irrigation are important research outcomes to enable valid irrigation benchmarks to be established and compared. Water-use performance is highly variable between cotton farmers and farming fields and across regions. Therefore, site-specific measurement is important. The range in the presented datasets indicates potential for further improvement in water-use efficiency and productivity on Australian cotton farms.