992 resultados para potentiometric titration
Resumo:
ABSTRACT Intrinsic equilibrium constants of 17 representative Brazilian Oxisols were estimated from potentiometric titration measuring the adsorption of H+ and OH− on amphoteric surfaces in suspensions of varying ionic strength. Equilibrium constants were fitted to two surface complexation models: diffuse layer and constant capacitance. The former was fitted by calculating total site concentration from curve fitting estimates and pH-extrapolation of the intrinsic equilibrium constants to the PZNPC (hand calculation), considering one and two reactive sites, and by the FITEQL software. The latter was fitted only by FITEQL, with one reactive site. Soil chemical and physical properties were correlated to the intrinsic equilibrium constants. Both surface complexation models satisfactorily fit our experimental data, but for results at low ionic strength, optimization did not converge in FITEQL. Data were incorporated in Visual MINTEQ and they provide a modeling system that can predict protonation-dissociation reactions in the soil surface under changing environmental conditions.
Resumo:
A recently developed calculation method to determine stoichiometric dissociation constants of weak acids from potentiometric titration data is described. The titration data from three different weak acids in aqueous salt solutions at 25 °C were used as examples of the use of the method. The salt alone determined the ionic strength of the solutions considered in this study, and salt molalities up to 0,5 mol kg -1 were used.
Resumo:
The simple single-ion activity coefficient equation originating from the Debye-Hückel theory was used to determine the thermodynamic and stoichiometric dissociation constants of weak acids from data concerning galvanic cells. Electromotive force data from galvanic cells without liquid junctions, which was obtained from literature, was studied in conjuction with the potentiometric titration data relating to aqueous solutions at 298.15 K. The dissociation constants of weak acids could be determined by the presented techniques and almost all the experimental data studied could be interpreted within the range of experimental error. Potentiometric titration has been used here and the calculation methods were developed to obtain the thermodynamic and stoichiometric dissociation constants of some weak acids in aqueous solutions at 298.15 K. The ionic strength of titrated solutions were adjusted using an inert electrolyte, namely, sodium or potassium chloride. Salt content alonedetermines the ionic strength. The ionic strength of the solutions studied varied from 0.059 mol kg-1 to 0.37 mol kg-1, and in some cases up to 1.0 mol kg-1. The following substances were investigated using potentiometric titration: aceticacid, propionic acid, L-aspartic acid, L-glutamic acid and bis(2,2-dimethyl-3-oxopropanol) amine.
Resumo:
A direct potentiometric titration method was applied to commercial and soil humic acids in order to determine their carboxyl and phenol group concentrations and apparent and intrinsic pK. In that context, acid-base properties of humic acids are interpreted by selective blocking of carboxylic and phenolic groups by esterification and acetylation. Differences in underivatized and derivatized HA's acid-base properties are ascribed to carboxyl and phenol groups influence on total humic acidity. Potentiometric data were treated with the modified Henderson-Hasselbalch equation. Infra red results, the acidic group contents and the average values of apparent and intrinsic pK for underivatized and derivatized HAs confirmed the selectivity of esterification derivatization method. After blocking of the functional groups, the values of acidic group contents decreased, while the value of apparent pK increased after derivatization. Phenol groups cannot be specifically identified by the acetylation method, due to low selectivity of the acetylation method.
Resumo:
A potentiometric titration method for the determination of minoxidil based on its redox reaction with K2Cr2O7 is described. The best results were observed using 1.00 x 10-3 mol L-1 K2Cr2O7 and 1.00 x 10-2 mol L-1 minoxidil solutions, and the minoxidil as titrant in 2.00 mol L-1 H2SO4 medium. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.4 to 98.7 % were observed depending on the sample. Comparison with the chromatographic procedure reveled agreement within 90% confidence level.
Resumo:
A potentiometric Nickel sensor was prepared using 2-hydroxy-1-naphthylidene-N-cyanoacetohydrazone as electro-active material and epoxy resin as a binding material. A membrane composed of 40% Schiff's base and 60% epoxy resin exhibited the best performance. The membrane showed excellent response in the concentration range of 0.15 ppm to 0.1 mol L- 1 Ni+2 ions with non-Nernstian slope of 22.0 mV/decade, had a rapid response time (less than 10 s), and can be used for three months without any considerable loss of potential. The sensor was useful within the pH range of 1.3 to 9.6, and was able to discriminate between Ni2+ and a large number of alkaline earth and transition metal ions. The practical utility of the sensor has been demonstrated by using it successfully as an indicator electrode in the potentiometric titration of Ni2+ with EDTA and oxalic acid.
Resumo:
A potentiometric titration method for the determination of minoxidil based on its redox reaction with K2Cr2O7 is described. The best results were observed using 1.00 x 10-3 mol L-1 K2Cr2O7 and 1.00 x 10-2 mol L-1 minoxidil solutions, and the minoxidil as titrant in 2.00 mol L-1 H2SO4 medium. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.4 to 98.7 % were observed depending on the sample. Comparison with the chromatographic procedure reveled agreement within 90% confidence level.
Resumo:
The combination of two low-cost classical procedures based on titrimetric techniques is presented for the determination of pyridoxine hydrochloride in pharmaceuticals samples. Initially some experiments were carried out aiming to determine both pKa1 and pKa2 values, being those compared to values of literature and theoretical procedures. Commercial samples containing pyridoxine hydrochloride were electrochemically analysed by exploiting their acid-base and precipitation reactions. Potentiometric titrations accomplished the reaction between the ionizable hydrogens present in pyridoxine hydrochloride, being NaOH used as titrant; while the conductimetric method was based on the chemical precipitation between the chloride of pyridoxine hydrochloride molecule and Ag+ ions from de silver nitrate, changing the conductivity of the solution. Both methods were applied to the same commercial samples leading to concordant results when compared by statistical tests (95 and 98% confidence levels). Recoveries ranging from 99.0 to 108.1% were observed, showing no significant interference on the results.
Resumo:
In many fields such as earth science biology, environment and electronics, the knowledge about elemental distributions and chemical speciation is important. The determination of metal levels especially the toxic ones both in the environment and in biological materials are increasingly demanded by the society.Ion selective sensors have become one of the most effective ad powerful means for analytical scientists for the trace level monitoring of metal ions. The wide range of applications ,low material requirements and simplicity of analytical procedure have not only brought ion-selective electrodes in to the lime light of analytical chemistry,but have promoted their use as tools for physiologists,medical researchers,biologists,geologists,environmental protection specialists etc.Potentiometric ion-selective sensors have been developed for the determination of lanthanide ions such as La3+,Nd3+,Pr3+,Sm3+, and Gd3+.The sensors fabricated include both PVC membrane sensor and chemically modified carbon paste sensor. A set of 10 sensors have been developed. The response parameters of all the sensors have been studied and the sensors were applied as an indicator electrode in the potentiometric titration and for the determination of metal ions in real samples.
Resumo:
Free fatty acids are a measure of evaluating fats and oils, submitted to abusive conditions, besides being a quality characteristic of edible vegetable oils. The official method of determination (AOCS Ca 5a-40, 2004) is based on titration, using phenolphthalein as an indicator. For crude and degummed oils, the titration end point is difficult to be observed due to the high level of pigments, resulting in dark solutions. In this case and others, such as self-life studies, in which sample quantities are limited, potentiometric titration may be a very good alternative.
Resumo:
In this work the influence of four different ligands present in the xylem sap of Quercus ilex (histidine, citric, oxalic and aspartic acids) on Ni(II) adsorption by xylem was investigated. Grinded xylem was trapped in acrylic columns and solutions of Ni(II), in the absence and presence of the four ligands prepared in KNO(3) 0-1 mol L(-1) at pH 5.5, were percolated through the column. Aliquots of solutions were recovered in the column end for Ni determination by graphite furnace atomic absorption spectrometry (GFAAS). The experimental. data to describe Ni sorption by xylem in both the presence and absence of ligands was better explained by the Freundlich isotherm model. The decreasing affinity order of ligands for Ni was: oxalic acid > citric acid > histidine > aspartic acid. On the other hand, the Ni(II) adsorption by xylem increased following the inverse sequence of ligands. Potentiometric titrations of acidic groups were carried out to elucidate the sorption site groups available in Q. ilex xylem. The potentiometric titration has shown three sorption sites: pK(a) 2.6 (57.7% of the sorption sites), related to monobasic aliphatic carboxylic acids or nitrogen aromatic bases, pK(a) 8.1 (9.6%) and pK(a) 9.9 (32.7%), related to phenolic groups. (C) 2008 Elsevier GmbH. All rights reserved.
Resumo:
A high cost-effective treatment of sulphochromic waste is proposed employing a raw coconut coir as biosorbent for Cr(VI) removal. The ideal pH and sorption kinetic, sorption capacities, and sorption sites were the studied biosorbent parameters. After testing five different isotherm models with standard solutions, Redlich-Peterson and Toth best fitted the experimental data, obtaining a theoretical Cr(VI) sorption capacity (SC) of 6.3 mg g(-1). Acid-base potentiometric titration indicated around of 73% of sorption sites were from phenolic compounds, probably lignin. Differences between sorption sites in the coconut coir before and after Cr adsorption identified from Fourier transform infrared spectra suggested a modification of sorption sites after sulphochromic waste treatment, indicating that the sorption mechanism involves organic matter oxidation and chromium uptake. For sulphocromic waste treatment, the SC was improved to 26.8 +/- 0.2 mg g(-1), and no adsorbed Cr(VI) was reduced, remaining only Cr(III) in the final solution. The adsorbed material was calcinated to obtain Cr2O3, with a reduction of more than 60% of the original mass. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
Acid base properties of mixed species of the microalgae Spirulina were studied by potentiometric titration in medium of 0.01 and 0.10 mols L-1 NaNO3 at 25.0±0.10 C using modified Gran functions or nonlinear regression techniques for data fitting. The discrete site distribution model was used, permitting the characterization of five classes of ionizable sites in both ionic media. This fact suggests that the chemical heterogeneity of the ionizable sites on the cell surface plays a major role on the acid-base properties of the suspension in comparison to electrostatic effects due to charge-charge interactions. The total of ionizable sites were 1.75±0.10 and 1.86±0.20 mmolsg-1 in ionic media of 0.01 and 0.10 mols L-1 NaNO3, respectively. A major contribution of carboxylic groups was observed with an average 34 and 22% of ionizable sites being titrated with conditional pcKa of 4.0 and 5.4, respectively. The remaining 44% of ionizable sites were divided in three classes with averaged conditional pcKa of 6.9, 8.7 and 10.12, which may be assigned respectively to imidazolic, aminic, and phenolic functionalities.
Resumo:
The data analyzed in this work were generated following the methodology developed by Molina et al.(J. Electroanal. Chem., 1979) for the calibration of a potentiometric system of measurement of hydrogen-ion concentrations resulting from neutralizations, at 25 ºC, of acidic or alkaline solutions at constant ionic strength (0.1 mol.l-1) held with NaClO4. The observed data present a serious deviation in relation to the mathematical model derived from the Nernst equation, for pH values ranging from 3 to 11, where pH=-log[H+]. We show that the minimization of the sum of the absolute values of the residuals gives estimates that are not influenced by outlying values.