913 resultados para port waters
Resumo:
Some Ecological Factors Affecting the Input and Population Levels of Total and Faecal Coliforms and Salmonella in Twelve Mile Creek, Lake Ontario and Sewage Waters Near St. Catharines, Ontario. Supervisor: Dr. M. Helder. The present study was undertaken to investigate the role of some ecological factors on sewage-Dorne bacteria in waters near St. Catharines, Ontario. Total and faecal coliform levels and the presence of Salmonella were monitored for a period of a year along with determination of temperature, pH, dissolved oxygen, total dissolved solids, nitrate N, total phosphate P and ammonium N. Bacteriological tests for coliform analysis were done according to APHA Standard Methods by the membrane filtration technique. The grab sampling technique was employed for all sampling. Four sample sites were chosen in the Port Dalhousie beach area to determine what bacteriological or physical relationship the sites had to each other. The sample sites chosen were the sewage inflow to and the effluent from the St. Catharines (Port Dalhousie) Pollution Control Plant, Twelve Mile Creek below the sewage outfall and Lake Ontario at the Lakeside Park beach. The sewage outfall was located in Twelve Mile Creek, approximately 80 meters from the creek junction with the beach and piers on Lake Ontario. Twelve Mile Creek normally carried a large volume of water from the WeIland Canal which was diverted through the DeCew Generating Station located on the Niagara Escarpment. An additional sample site, which was thought to be free of industrial wastes, was chosen at Twenty Mile Creek, also in the Niagara Region of Ontarioo 3 There were marked variations in bacterial numbers at each site and between each site, but trends to lower_numbers were noted from the sewage inflow to Lake Ontario. Better correlations were noted between total and faecal coliform population levels and total phosphate P and ammonium N in Twenty Mile Creek. Other correlations were observed for other sample stations, however, these results also appeared to be random in nature. Salmonella isolations occurred more frequently during the winter and spring months when water temperatures were minimal at all sample stations except the sewage inflow. The frequency of Salmonella isolations appeared to be related to increased levels of total and faecal coli forms in the sewage effluent. However, no clear relationships were established in the other sample stations. Due to the presence of Salmonella and high levels of total and faecal coliform indicator organisms, the sanitary quality of Lake Ontario and Twelve Mile Creek at the sample sites seemed to be impaired over the major portion of the study period.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
European fishery off Mauritania (one of the most productive and most intensively exploited regions in the world) targeted to small pelagic fish accounts for 30% of the total catches in the area. The Instituto Español de Oceanografía (IEO), through its Centro Oceanográfico de Canarias, follows up the activity of these vessels that land at Spanish port (Las Palmas de Gran Canaria, Spain), under the European Project Data Collection (Regulation (EC) 1543/2000). One of the target groups in this fishery is Trachurus spp, commercially named “JAX”. During 2008 and 2009, several samples of this group from these landings were analysed, and Caranx rhonchus was the second species of importance. The mixture of these species in the landings of this UE fleet should be determined to improve the data provided to the international Working Groups responsible for assessment of those resources.
Resumo:
Background, aim, and scope Contaminated sediments are a worldwide problem, and mobilization of contaminants is one of the most critical issues in environmental risk assessment insofar as dredging projects are concerned. The investigation of how toxic compounds are mobilized during dredging operations in the channel of the Port of Santos, Brazil, was conducted in an attempt to assess changes in the bioavailability and toxicity of these contaminants.Materials and methods Bulk sediment samples and their interstitial waters and elutriates were subjected to chemical evaluation and ecotoxicological assessment. Samples were collected from the channel before dredging, from the dredge's hopper, and from the disposal site and its surroundings.Results The results indicate that the bulk sediments from the dredging site are contaminated moderately with As, Pb, and Zn and severely with Hg, and that polycyclic aromatic hydrocarbon (PAH) concentrations are relatively high. Our results also show a 50% increase in PAH concentrations in suspended solids in the water collected from the hopper dredge. This finding is of great concern, since it refers to the dredge overflow water which is pumped back into the ecosystem. Acute toxicity tests on bulk sediment using the amphipod Tiburonella viscana showed no toxicity, while chronic tests with the sea urchin Lytechinus variegatus showed toxicity in the interstitial waters and elutriates. Results are compared with widely used sediment quality guidelines and with a sediment quality assessment scheme based on various lines of evidence.Conclusions The data presented here indicate that the sediments collected in this port show a certain degree of contamination, especially those from the inner part of the channel. The classification established in this study indicated that sediments from the dredged channel are impacted detrimentally and that sea disposal may disperse contaminants. According to this classification, the sediments are inappropriate for disposal at sea. It should be emphasized that the poor quality of fine sediments discharged from the hopper dredge in the overflow process can recontaminate the environment.Recommendations and perspectives These findings will help to underpin improved planning of management strategies for dredging operations and sediment disposal in Brazil and other countries.
Resumo:
Acid drainage influence on the water and sediment quality was investigated in a coal mining area (southern Brazil). Mine drainage showed pH between 3.2 and 4.6 and elevated concentrations of sulfate, As and metals, of which, Fe, Mn and Zn exceeded the limits for the emission of effluents stated in the Brazilian legislation. Arsenic also exceeded the limit, but only slightly. Groundwater monitoring wells from active mines and tailings piles showed pH interval and chemical concentrations similar to those of mine drainage. However, the river and ground water samples of municipal public water supplies revealed a pH range from 7.2 to 7.5 and low chemical concentrations, although Cd concentration slightly exceeded the limit adopted by Brazilian legislation for groundwater. In general, surface waters showed large pH range (6 to 10.8), and changes caused by acid drainage in the chemical composition of these waters were not very significant. Locally, acid drainage seemed to have dissolved carbonate rocks present in the local stratigraphic sequence, attenuating the dispersion of metals and As. Stream sediments presented anomalies of these elements, which were strongly dependent on the proximity of tailings piles and abandoned mines. We found that precipitation processes in sediments and the dilution of dissolved phases were responsible for the attenuation of the concentrations of the metals and As in the acid drainage and river water mixing zone. In general, a larger influence of mining activities on the chemical composition of the surface waters and sediments was observed when enrichment factors in relation to regional background levels were used.
Resumo:
A capillary zone electrophoresis (CE) method was developed for the determination of the biocide 2,2-dibromo-3-nitrilo-propionamide (DBNPA) in water used in cooling systems. The biocide is indirectly determined by CE measurement of the concentration of bromide ions produced by the reaction between the DBNPA and bisulfite. The relationship between the bromide peak areas and the DBNPA concentrations showed a good linearity and a coefficient of determination (R(2)) of 0.9997 in the evaluated concentration range of 0-75 μmol L(-1). The detection and quantification limits for DBNPA were 0.23 and 0.75 μmol L(-1), respectively. The proposed CE method was successfully applied for the analysis of samples of tap water and cooling water spiked with DBNPA. The intra-day and inter-day (intermediary) precisions were lower than 2.8 and 6.2%, respectively. The DBNPA concentrations measured by the CE method were compared to the values obtained by a spectrophotometric method and were found to agree well.
Resumo:
A solid-phase in-line extraction system for water samples containing low levels of emerging contaminants is described. The system was specially developed for large volume samples (up to 4 L) using commercial solid-phase extraction (SPE) cartridges. Four sets containing PTFE-made connectors, brass adapters and ball valves were used to fit SPE cartridges and sample bottles to a 4-port manifold attached to a 20 L carboy. A lab-made vacuum device was connected to the manifold cap. The apparatus is robust and less expensive than the typical available system. Its also provides less experimental handling, avoiding cross contamination and sample losses.
Resumo:
This paper describes a sequential injection chromatography procedure for determination of picloram in waters exploring the low backpressure of a 2.5 cm long monolithic C18 column. Separation of the analyte from the matrix was achieved in less than 60 s using a mobile phase composed by 20:80 (v v-1) acetonitrile:5.0 mmol L-1 H3PO4 and flow rate of 30 μL s-1. Detection was made at 223 nm with a 40 mm optical path length cell. The limits of detection and quantification were 33 and 137 μg L-1, respectively. The proposed method is sensitive enough to monitor the maximum concentration level for picloram in drinking water (500 μg L-1). The sampling frequency is 60 analyses per hour, consuming only 300 μL of acetonitrile per analysis. The proposed methodology was applied to spiked river water samples and no statistically significant differences were observed in comparison to a conventional HPLC-UV method.
Resumo:
Horizontal and vertical distribution patterns and abundance of larval phosichthyids were investigated from oblique and depth-stratified towns off Southeastern brazilian waters, from São Tomé cape (41ºW.; 22ºS.) to São Sebastião island (45ºW.; 24ºS.). The sampling was performed during two cruises (January/2002 -summer; August/2002 -winter). Overall 538 larvae of Phosichthyidae were collected during summer and 158 in the winter. Three species, Pollichthys mauli, Vinciguerria nimbaria and Ichthyioccoccus sp. occurred in the area, but Ichthyioccoccus sp. was extremely rare represented by only one specimen, caught in the oceanic region during the summer. Geographically, larval were concentrated in the oceanic region, and vertically distributed mainly between the surface and 80 m depth in the summer and winter. Larvae were more abundant during the night, performing a diel vertical migration in the water column. The results suggest that the meandering and eddies of Brazil Current play important role on the transport and distribution patterns of larval phosichthyids over the oceanic and neritic area in the Southeastern Brazil.
Resumo:
A new cheilostome bryozoan genus Marcusadorea (type species Marcusadorea jamaicensis n. sp. from the north coast of Jamaica) is described and illustrated along with a second species, Coleopora corderoi Marcus, 1949 from Southeast Brazil. A third species, Holoporella tubulosa Canu & Bassler, 1928, described from the Caribbean, but also present in Brazil, is included in this genus and redescribed. At least one Indo-West-Pacific species, ""Cosciniopsis"" efatensis Tilbrook, 2006, is a congener.
Resumo:
A green and highly sensitive analytical procedure was developed for the determination of free chlorine in natural waters, based on the reaction with N,N-diethyl-p-phenylenediamine (DPD). The flow system was designed with solenoid micro-pumps in order to improve mixing conditions by pulsed flows and to minimize reagent consumption as well as waste generation. A 100-cm optical path flow cell based on a liquid core waveguide was employed to increase sensitivity. A linear response was observed within the range 10.0 to 100.0 mu g L(-1), with the detection limit, coefficient of variation and sampling rate estimated as 6.8 mu g (99.7% confidence level), 0.9% (n = 20) and 60 determinations per hour, respectively. The consumption of the most toxic reagent (DPD) was reduced 20,000-fold and 30-fold in comparison to the batch method and flow injection with continuous reagent addition, respectively. The results for natural and tap water samples agreed with those obtained by the reference batch spectrophotometric procedure at the 95% confidence level. (C) 2010 Elsevier By. All rights reserved.
Resumo:
An improved procedure is proposed for determination of the pesticide carbaryl in natural waters based on double cloud point extraction. The clean up step was carried out only with Triton X-114 in alkaline medium in order to avoid the use of toxic organic solvents as well as to minimise waste generation. Cloud point preconcentration of the product of the reaction of the analyte with p-aminophenol and cetyltrimethylammonium bromide was explored to increase sensitivity and improve the detection limit. Linear response was achieved within 10 and 500 mu g L-1 and the apparent molar absorptivity was estimated as 4.6 x 105 L mol-1 cm-1. The detection limit was estimated as 7 mu g L-1 at the 99.7% confidence level and the coefficient of variation was 3.4% (n = 8). Recoveries within 91 and 99% were estimated for carbaryl spiked water samples. The results obtained for natural water samples were in agreement with those achieved by the batch of spectrophotometric procedure at the 95% confidence level. The proposed procedure is then a simple, fast, inexpensive and greener alternative for carbaryl determination.
Resumo:
A flow system designed with solenoid micro-pumps is proposed for the determination of paraquat in natural waters. The procedure involves the reaction of paraquat with dehydroascorbic acid followed by spectrophotometric measurements. The proposed procedure minimizes the main drawbacks related to the standard chromatographic procedure and to flow analysis and manual methods with spectrophotometric detection based on the reaction with sodium dithionite, i.e. high solvent consumption and waste generation and low sampling rate for chromatography and high instability of the reagent in the spectrophotometric procedures. A home-made 10-cm optical-path flow cell was employed for improving sensitivity and detection limit. Linear response was observed for paraquat concentrations in the range 0.10-5.0 mg L-1. The detection limit (99.7% confidence level), sampling rate and coefficient of variation (n = 10) were estimated as 22 mu g L-1, 63 measurements per hour and 1.0%, respectively. Results of determination of paraquat in natural water samples were in agreement with those achieved by the chromatographic reference procedure at the 95% confidence level. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
A multi-pumping flow system exploiting prior assay is proposed for sequential turbidimetric determination of sulphate and chloride in natural waters. Both methods are implemented in the same manifold that provides facilities for: in-line sample clean-up with a Bio-Rex 70 mini-column with fluidized beads: addition of low amounts of sulphate or chloride ions to the reaction medium for improving supersaturation; analyte precipitation with Ba(2+) or Ag(+); real-time decision on the need for next assay. The sample is initially run for chloride determination, and the analytical signal is compared with a preset value. If higher, the sample is run again, now for sulphate determination. The strategy may lead to all increased sample throughput. The proposed system is computer-controlled and presents enhanced figures of merit. About 10 samples are run per hour (about 60 measurements) and results are reproducible and Unaffected by the presence of potential interfering ions at concentration levels usually found in natural waters. Accuracy was assessed against ion chromatography. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
A rapid method for classification of mineral waters is proposed. The discrimination power was evaluated by a novel combination of chemometric data analysis and qualitative multi-elemental fingerprints of mineral water samples acquired from different regions of the Brazilian territory. The classification of mineral waters was assessed using only the wavelength emission intensities obtained by inductively coupled plasma optical emission spectrometry (ICP OES), monitoring different lines of Al, B, Ba, Ca, Cl, Cu, Co, Cr, Fe, K, Mg, Mn, Na, Ni, P, Pb, S, Sb, Si, Sr, Ti, V, and Zn, and Be, Dy, Gd, In, La, Sc and Y as internal standards. Data acquisition was done under robust (RC) and non-robust (NRC) conditions. Also, the combination of signal intensities of two or more emission lines for each element were evaluated instead of the individual lines. The performance of two classification-k-nearest neighbor (kNN) and soft independent modeling of class analogy (SIMCA)-and preprocessing algorithms, autoscaling and Pareto scaling, were evaluated for the ability to differentiate between the various samples in each approach tested (combination of robust or non-robust conditions with use of individual lines or sum of the intensities of emission lines). It was shown that qualitative ICP OES fingerprinting in combination with multivariate analysis is a promising analytical tool that has potential to become a recognized procedure for rapid authenticity and adulteration testing of mineral water samples or other material whose physicochemical properties (or origin) are directly related to mineral content.